Manualios.com

LG G3L-PUEA Operation & User’s Manual

  • G3L-PUEA Computer Hardware
  • mabxF7NH7g//.
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 98

LG G3L-PUEA Manual Online:

4.45, 1774 votes
LG G3L-PUEA User Manual
LG G3L-PUEA User Guide
LG G3L-PUEA Online Manual

Text of LG G3L-PUEA User Guide:

  • LG G3L-PUEA, CHAPTER 6 COMMUNICATION FUNCTION 6-27 (A) Simple system For the system that total communication station is under 10 stations and total size of sending data is less than 512 bytes, it is recommended to calculate high speed link speed by the simple formula as like Formula 1: Formula 1 St = P_ScanA + C_Scan + P_ScanB (St = high speed link max. transmission time P_ScanA = plc A max. program scan time P_ScanB = plc B max. program scan time C_Scan = max. communication scan time ) In Formula 1, C_Scan can be calculated easily by the following formula. Formula 2 C_Scan =

  • CHAPTER 6 COMMUNICATION FUNCTION  • Sending/receiving parameter setting by SmartI/O (Station 1, 2 & 3) slave Select this bar of slot no.0 and generate the high speed link modification window for sending/receiving area selection. Select the receiving area as the area receiving from slave(GPL-D22A) area to master(GM4) and the sen

  • CHAPTER 6 COMMUNICATION FUNCTION  6.2 Example Program 6.2.1 Pnet master slave communication in GMWIN Example 1 Communication module (Station 0) G4L-PUEA is installed in GM4 base slot 0, communication module G7L-PBEA in GM7. This is the program for sending/receiving the data from station 0(master) to station 1(slave). (Refer to I/O co

  • LG G3L-PUEA, CHAPTER 9 TROUBLE SHOOTING  9-1 CHAPTER 9 TROUBLE SHOOTING Here describes a variety of error occurring during system operation, the causes, the detection methods and actions. 9.1 Basic procedure of Trouble shooting In order to increase the reliability of system, it is important to use the reliable device and at the same time, the important thing is how fast to take the actions by any ways in case of error occurrence. The most important thing to operate the system promptly, is to detect the trouble occurrence cause and take the actions immedi

  • LG G3L-PUEA, CHAPTER 3 GENERAL SPECIFICATION 3-1 CHAPTER 3 GENERAL SPECIFICATION 3.1 General Specification The General Specification for the communication module of GLOFA series and MASTER-K series is as follows: No. Items Specification Reference 1 Use Temperature 0 ~ 55 °C 2 Storage Temp. −25°C ~ +70 °C 3 Use humidity 5 ~ 95%RH, no dew 4 Storage humidity 5 ~ 95%RH, no dew In case of Intermittent vibration - Frequency Acceleration Amplitude Times 10 ≤ f < 57Hz − 0.075mm 57 ≤ f ≤ 150Hz 9.8m/s 2 {1G} − In case of Continuous vibration Frequency Acceleration Amplitude 10 ≤ f < 57Hz − 0.035mm 5 Vibration-resistant 57

  • CHAPTER 1 OVERVIEW 1-2 1.1 Notices in using When you install this device, cares should be taken to the following items for the reliability and safety of system. Items Classification Description Condition • When installing this device, the use temperature should be 0 ~ 55℃ for the part elements. • Direct exposure to the direct ray of light is no

  • LG G3L-PUEA, CHAPTER 7 DIAGNOSIS FUNCTION 7-1 CHAPTER 7 DIAGNOSIS FUNCTION 7.1 LED Master station : indicates ‘run’ by 5 LED. G3/4L-PUEA/PUEB G6L-PUEA/PUEB Classification State Meaning On Normal communication Blink Parameter error RUN Off Communication stop On Normal module Blink Abnormal Hardware/Software READY Off Abnormal Hardware On Communication line error ERROR Off No error in communication line On Token secured STATUS Off Yield token to other master On/Off PLC body and interface abnormal LINK-IF Blink PLC body and interface normal Table 7.1 Master LED status indicati

  • LG G3L-PUEA, CHAPTER 8 INSTALLATION AND STARTUP 8-6 8.3 Maintenance & Checking 8.3.1 Daily Checking The following table shows the check details to be carried out daily. Checking items Description Judgment criteria Action Cable connection state Cable loosening No loosening Tighten the cable Screw loosening No loosening Tighten the terminal screw Terminal connection state Approach between compressing terminal Proper interval Correction RUN ‘ON’ check ON (OFF is abnormal) READY ‘ON�

  • LG G3L-PUEA, CHAPTER 6 COMMUNICATION FUNCTION  • GM7 Station 1 sending/receiving parameter setting • Master module ‘high speed link 1’ setting completion screen Receiving area is the area receiving from slave(GM7) area to master(GM4) and, designate the sending area as the area to send from master(GM4) to slave(GM7). When setting I/O size in SyCon, set the same size as high speed link setting.

  • LG G3L-PUEA, CHAPTER 6 COMMUNICATION FUNCTION  • Slave Configuration Settings Slave Configuration selection The basic I/O score is designated in Smart I/O GSD file. • Device Assignment Settings Device Assignment COM port selection OK - COM port selection : After selecting Connect COM1 or Connect COM2, if the small window appears on the left COM1,COM2, select the window and then press OK.

  • LG G3L-PUEA, CHAPTER 6 COMMUNICATION FUNCTION  Point 1) The I/O contact size of sending area and receiving area should be set as the same as that of KGLWIN program and SyCon. When selecting Smart I/O module in SyCon, the sending/receiving area size of each module shall be set automatically.(available to verify in Slave Setting window.) 2) G4L-PUEA 1EA and GPL-TR2A(16points), GPL-D22A(16points), GPL-RY2A (16points) are created in order and when setting the sending area as %MW0, receiving area as %MW100, * Sending area : %MW0 * Receiving area : %QW0.2.0 * Sending area size : 4 bytes(total output contact number) * Receiving area size :

  • LG G3L-PUEA, CHAPTER 9 TROUBLE SHOOTING  9-7 9.1.6 High speed link operation error Hi g h s p eed link o p eration error Did you check ‘ON’ for Link Enable setting ? No End No No No No No Yes Yes Yes Yes Yes Yes Is the station no. setting method of each registration item correct ? Modify the station no. setting. Does the network type/slot no./self station no. match with the relevant slot among link settings ? Modify the link setting suitable for the network type/station no./slot no. of the relevant slot. Check ‘ON’ of relevant link enable from link enable settings. Is there any problem in netw

  • LG G3L-PUEA, CHAPTER 6 COMMUNICATION FUNCTION 6-54 • Communication opening verification Online Start Communication Start Debug Mode Point 1) The size of sending area and receiving area is total I/O contact number created in KGLWIN. When setting K80S Slave in SyCon, the I/O contact number in Slave Setting should be the same as high speed link setting size of KGLWIN program. 2) G4L-PUEA 1EA and GM7-PBEA 1EA are created in order and when setting the sending area of master as P004, receiving area as P002, * Sending area : P004 * Recei

  • CHAPTER 6 COMMUNICATION FUNCTION 6-12 B) Setting function The items of high speed link from Figure 6.18 means max. number of communication module installation according to PLC CPU type. For example, GLOFA-GM1/GM2/GM3 CPU is available to install max. 4 communication modules that enables to set in high speed link 1~4. For GLOFA-GM4 CPU, it is available to install

  • LG G3L-PUEA, CHAPTER 6 COMMUNICATION FUNCTION  • Device Assignment Settings Device Assignment COM port selection OK - COM port selection : After selecting Connect COM1 or Connect COM2, if the window appears on the left COM1,COM2, select the window and then select OK. • Download Online Download In case of Error, check the Configuration cable and connector. COM port window

  • LG G3L-PUEA, CHAPTER 9 TROUBLE SHOOTING  9-2 9.1.1 Hardware Error Is the impressed power normal ?  Is the installation environment suitable for the spec. ?  No Yes Yes Yes Yes Yes No No No No Hardware error It’s hardware error of communication module. Contact A/S center. Does the same error occur ?   Rerun the power.  Is communication module installed correctly ?   Operation  Is it acting normally ? Perform the troubleshooting for the relevant error. Supplement the installation environment. Install the communication module correctly.  Check the power/voltage.

  • LG G3L-PUEA, CHAPTER 6 COMMUNICATION FUNCTION 6-11 6.1.4 High speed link parameter settings in GMWIN High speed link parameter selects the link parameter from the GMWIN project screen and sets the relevant items. The setting procedure and the function per item are as follows : 1) High speed link parameter setting in GMWIN If you select ‘high speed link parameter’ from the basic screen of the project in Figure 6.17, you are led to the basic screen of high speed link parameter of Figure 6.18 and able to select the relevant items. Figure 6.17 GMWIN Project Basic Screen 2) High speed link parameter

  • LG G3L-PUEA, CHAPTER 9 TROUBLE SHOOTING  9-5 9.1.4 CPU and Interface Error during Operation CPU error type is interface error of communication module ? Yes No Yes Yes Yes No No No No Yes Interface error duringoperation End Is CPU error type an interface error of I/O module or special module ? It’s a hardware error of communication module. Contact A/S center. Is the installation environment suitable for the spec. ? Is the communication module installed in the mai

  • LG G3L-PUEA, CHAPTER 6 COMMUNICATION FUNCTION  2) High speed link parameter setting in GM7(Station 1) • Slave module GMWIN program (GM7) • Slave module ‘link information’ setting Slave module(GM7) high speed link network type setting. Parameter setting in registration list after selectin g FIELDBUS slave.

Related Products and Documents (Computer Hardware):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Milwaukee V28 0724-20 Operator's manual milwaukee/v28-0724-20-QLK.pdf 23 Dec 2022 21
2 Sentry US WAP-ABG2458 Operation & user’s manual sentry-us/wap-abg2458-B3N.pdf 20 Jul 2023 56
3 Adastra RM series Operation & user’s manual adastra/rm-series-42B.pdf 22 Jul 2022 8
4 Aroma ARC-733G Instruction manual aroma/arc-733g-N59.pdf 12 Dec 2022 12 0.14 Mb
5 Canon TS-E 24mm 1:3.5 L Parts catalog canon/ts-e-24mm-1-3-5-l-541.pdf 13 Jan 2023 8 0.13 Mb
6 ACTiSYS IR220VACF Specifications actisys/ir220vacf-BSV.pdf 22 Jul 2023 1 0.07 Mb

Similar Resources:

  • SeaLevel

    ACB-II/EX

    (28 pages)
    1 © Sealevel Systems, Inc. 4061 Manual | SL9164 11/2021 ACB-II / EX User Manual | 4061 …
  • Eurotech

    Zypad WL15 Series

    (2 pages)
    Zypad WL15xx - Quick Start Page 1 Page 2 Page 3 Features Zypad WL15xx Kit Your kit includes the following components: • Zypad WL15xx • Wrist strap with armband • Stylus • Lithium-Ion battery pack • AC adapter and regional power cord • USB host cable (for terminal) • Y-USB client cable (for USB & power) For full product det …
  • American Dynamics

    ADQUAD27

    (2 pages)
    www.americandynamics.netThe ADQUAD27 and ADQUAD77 SeriesStandard Digital Quads provide live displayoptions during quad recording, comprehensivealarm capabilities, and the operationalfunctions that users want most. These quadsoffer the performance, flexibility and controldemanded by today’s security professionals. View up to four live cameras simultaneously …
  • StarTech.com

    PEX2PECP2

    (8 pages)
    Manual Revision: 07/11/2012For the most up-to-date information, please visit: www.startech.comDE: Bedienungsanleitung - de.startech.comFR: Guide de l'utilisateur - fr.startech.comES: Guía del usuario - es.startech.comIT: Guida per l'uso - it.startech.comNL: Gebruiksaanwijzing - nl.startech.comPT: Guia do usuário - pt.startech.comPEX2PECP22 Port P …
  • HP

    629135-B21

    (12 pages)
    The HP Ethernet 1Gb 4-port 331FLR Adapter for select HP ProLiant Gen8 rack servers features the next generation of Ethernetintegration, offering a single-chip solution in a FlexibleLOM form factor, which offers the option for future upgrades to 10GbEnetworking speeds. It delivers full line-rate performance across all ports with low power consumption.The HP 3 …
  • Endace

    DAG 3.8S

    (48 pages)
                            …

Comments, Questions and Opinions: