LG PREMTB10U, 34 OPERATION INSTRUCTION ENGLISH Function Setting - Set back temperature It is the function to set default temperature setting points for set back operation. It used when controller doesn’t have last unoccupied schedule. Press button to complete and active the setting process. 3 Press button to exit. ❈ After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. 4 Use button to select Set back temperature setting. Press button repeatedly t
LG PREMTB10U, Programming - Sleep Reservation Sleep reservation is the function of air-conditioner to run and stop after certain period of time at sleep mode before sleep. When connected to a ventilation product and set the sleep reservation, when it goes to the sleep mode, after the set time has elapsed. Press button to enter the Programming mode. Ex) Setting Sleep Reservation time as ’3’. 1 Repeat pressing button to enter the SLEEP reservation setting mode. ( segment flashing) 2 Press
LG PREMTB10U, 16 OPERATION INSTRUCTION ENGLISH Standard Operation - Auto Operation Mode Press button to turn on the indoor. 1 Press button to select Auto operation mode. 2 Press the button to select Cooling set point, and Cooling set point can be controlled by pressing the button . 3 Press the button to select Heating set point, and Heating set point can be controlled by pressing the button . 4 Cooling operation state Heating operation state • Auto heating drive only operates on cooling and heating models. • Auto heating doesn’t operate on cooling only models. • 87~99 °F (30.5~37.5 °C) When setting the desired cooling temper
10 PART DESCRIPTION ENGLISH Function Icon Description Function setting Grill state : up / : stop / : down Child lock setting step :Child lock set / : Child lock cancel Minimum difference value setting step between cooling / heating set points Current time setting step Schedule override timer setting step Default Set back cooling / heating temperature
LG PREMTB10U, OPERATION INSTRUCTION 43 ENGLISH Select desired fan speed by pressing the button. 22 Enter fan speed setting mode by pressing the button. Fan speed icon in window will blink. 21 If you setup with the method identical with above by selecting the day that you’d like to setup, it operates weekly reservation. 24 If finishing weekly reservation setup, please press the button. Weekly reservation setup for the day that you set is finished. 23 Weekly schedule Side bar : the indication
LG PREMTB10U, PART DESCRIPTION 9 ENGLISH Function Icon Description Schedule Reservation Simple reservation in operation Sleep reservation in operation weekly reservation in operation Holiday reservation in operation Schedule Reservation & Time Day of week SUN: Sunday / MON: Monday / TUE: Tuesday WED: Wednesday / THU: Thursday / FRI: Friday SAT: Saturday The number of weekly reservation event Time - AM/PM Time – value of hour / minute min.: minute / hr. : hour Turn on/off by schedule reservation Display weekly reservation occupied / unoccupied state Weekly reservation schedule data copy / paste Function setting Louver angle setting step 1,2,3,4,A
LG PREMTB10U, OPERATION INSTRUCTION 17 ENGLISH Standard Operation - Timed Override Timed override operation changes occupied / unoccupied schedule for override time temporarily. - It revert to last occupied schedule in unoccupied override. - It revert to last unoccupied schedule in occupied override. - You can set ‘Override time’ by ‘Function setting – Override set time’ Press button for 3 seconds, you can operate timed override. 1 Operate Timed override Cancel Timed override Press button for 3 seconds in Timed override mode, you can cancel Timed override. - it revert to last weekly reservation schedule. • It revert to default operation setting if The
LG PREMTB10U, INSTALLATION INSTRUCTION 71 ENGLISH Installer Setting - Dry Contact Mode Setting Dry contact function is the function that is possible to use only when dry contact equipment is separately purchased/setup. Function Code Dry Contact setting value Select Dry contact setting by pressing button. (00 : Manual, 01 : Automatic) 3 Press button to save. 4 If pressing button long for 3 seconds, it enters into Thermostat installer setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. 1 If pressing button repeatedly,
LG PREMTB10U, 74 INSTALLATION INSTRUCTION ENGLISH Move to Low Outdoor Ambient Heating Operation setting by pressing button. 4 Press button to setup Low Outdoor Ambient Heating Operation. 5 Press button to save. 8 Press button to exit or system will automatically exit after 25 seconds without any input. 9 Move FAN Speed Setting during Emergency Heater Operation by pressing button. 6 Press button to setup FAN Speed during Emergency Heater Operation. 7 0 : not use 1 : use - compressor off(0℉/ -18℃) / compressor on(5℉ / -15℃) 2 : use - compressor off(5℉ / -15℃) / compressor on(10℉ / -12
64 INSTALLATION INSTRUCTION ENGLISH Installer Setting - Setting Address of Central Control It's the function to use for connecting central control. Please refer to central controller manual for the details Function Code Group No Indoor No. Set Group No. by pressing button.(0~F) 3 Move to Indoor No. setting option by pressing button. 4 Set Indoor No. by pressin
LG PREMTB10U, 24 OPERATION INSTRUCTION ENGLISH Sub Function - Electric Heater It is a function to strengthen the heating ability by turning on the electric heater during the heat- ing operation. It can only be set during heating operation. Repeatedly pressing button until icon flash. 1 Turn on/off electric heater by pressing button (the icon will be displayed in case of setting option and disappear in reverse case .) 2 Press button to exit. ❈ After setup, it automatically gets out of setup mode if there is no button input for
LG PREMTB10U, 2 TIPS FOR SAVING ENERGY ENGLISH TIPS FOR SAVING ENERGY Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below: • Do not cool excessively indoors. This may be harmful for your health and may consume more electricity. • Block sunlight with blinds or curtains while you are operating the air conditioner. • Keep doors or windows closed tightly while you are operating the air conditioner. • Adjust the direction of the air flow
LG PREMTB10U, OPERATION INSTRUCTION 36 ENGLISH Programming - Simple Reservation You can set the reservation conveniently in the units of 1 hour from 1 hour to 7 hours. * When simple timer setup, product automatically runs or stops after the time that is set. Press button on the Thermostat. (the ‘SIMPLE’ segment will blink) 1 Press button to adjust reservation time. 2 Press button to finish setting. 3 Press button to exit. ❈ After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. - If reservation is setup, ’sleep’ indication
OPERATION INSTRUCTION 49 ENGLISH Ventilation Product - lnterlocked Air conditioner and Ventilator 1 Control using Thermostat where air conditioner indoor unit and the ventilation product is in- stalled at the same time. - When the power is turned on, your Thermostat recognizes the product (takes about 30 sec- onds) and then works normally. 2 Press 'Ventilation' butt
LG PREMTB10U, INSTALLATION METHOD 57 ENGLISH 5 Please use an extension cable if the distance between the Thermostat and the indoor unit is longer than 32ft (10m). C In case of loosened screws or insufficient contact between the terminal and the wire, thermo- stat may not function properly. C When the power is off on the Thermostat, check the connection between the Thermostat and Terminal Block . C Use an appropriate screwdriver for tightening the terminal screws. A screwdriver with a small head will strip the head and make proper tightening impossible. C Over-tightening the terminal screws may break wires and terminal block structure. CAUTION When ins
LG PREMTB10U, OPERATION INSTRUCTION 21 ENGLISH Sub Function - Plasma Purification Only products with Plasma Purification function can use this. Repeat pressing button until icon flash. The method to setup cleaning air 1 Operate or cancel Plasma Purification function by pressing button. 2 After setting, press button to exit. 3 ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. • Cleaning air function is additional function and it might not be available on all products. • Cleani
LG PREMTB10U, 58 INSTALLATION METHOD ENGLISH Thermostat installation Since the room temperature sensor is in the Thermostat, the Thermostat box should be installed in a place away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature. Install the Thermostat about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature. Do not install the Thermostat where it can be affected by: - Drafts, or dead spots behind doors and in corners. - Hot or cold air from ducts. - Radiant heat from sun or appliances. - Concealed pipes and chimneys. - Uncontrolled areas suc
LG PREMTB10U, 6 PART DESCRIPTION ENGLISH Accessory Name and Function of Thermostat PART DESCRIPTION 1 Operation indication screen 2 Set temperature button 3 Fan Speed button 4 Set back button 5 Operation mode selection button 6 Wireless Thermostat receiver - Some product don’t receive the wireless signals. 7 Sub function button 8 Ventilation button 9 Reservation button 10 Air flow button 11 Cooling desired temperature 12 Function setting button 13 Up, Down, Left, Right button 14 On/Off button 15 Heating desired temperature 16 Setting/Cancel but
60 INSTALLATION INSTRUCTION ENGLISH Installer Setting - How to enter installer setting mode • Some categories of the menu may not be displayed according to the function of the prod- uct, or the menu name may be different. Function Code Value If pressing button long for 3 seconds, it enters into Thermostat installer setup mode. - If pressing once shortly, it enters into
DOWNLOAD |
Schluter Systems DH E RS D Thermostat Operation & user’s manual
DH E RS D |
Lennox icomfort Wi-Fi Thermostat Homeowner's manual
icomfort Wi-Fi |
Honeywell T87F Thermostat Installation instructions
T87F |
LG DFSWLWT0A Thermostat Instruction manual
DFSWLWT0A |
Dri-Eaz Dragon X2 Thermostat Owner's manual
Dragon X2 |
Lennox Elite series Thermostat Homeowner's manual
Elite series |
Agilent Technologies 1100 Series Thermostat Quick start manual
1100 Series |
Pro1 IAQ T755S Thermostat Installation manual
T755S |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Asus | P2E-M | Operation & user’s manual | asus/p2e-m-333.pdf | 09 Feb 2024 | 64 | 1.37 Mb |
2 | LG | 42LM6410 | Operation & user’s manual | lg/42lm6410-428.pdf | 07 Oct 2022 | 177 | |
3 | Quantum Composers | 9212, 9214 | Specification | quantum-composers/9212-9214-AI7.pdf | 19 Oct 2023 | 3 | 0.77 Mb |
4 | KitchenAid | KSRS25RSMS03 | Parts list | kitchenaid/ksrs25rsms03-86J.pdf | 16 Sep 2023 | 21 | |
5 | SIIG | Hi-Speed ExpressCard CF R/W | Quick installation manual | siig/hi-speed-expresscard-cf-r-w-688.pdf | 24 Oct 2023 | 8 | 0.13 Mb |
6 | SATO | MB400 | Parts list | sato/mb400-4I3.pdf | 26 Feb 2024 | 12 | 0.88 Mb |
CAME
PSRT01www.came.comUNI6954 4.8 x 9.5L N-1010203040°C807060500①②④⑤③❶❷❸❹ItalianoITITEnglishENENFrançaisFRFRРусскийRURUFA00625M4AFA00625M4A - ver. 1 - 01/2017
…
PSRT01(2 pages) |
Pro 1 IAQ
This manual covers the following models:• T705OPERATING MANUALCaution: Equipment damage hazard Do not operate the cooling system if the outdoor temperature is below 50˚ F(10˚ C) to prevent possible compressor damage.Thermostat Quick ReferenceThermostat OperationProgrammingContact Us and Warranty Registration2346Congratulations on purchasing a new thermos …
T705(6 pages) |
Plugwise
Quick start NL | EN | DE | FR6000-0084 3LisaModel 158-01 [email protected] B.V. Wastraat 56, 2171 TR Sassenheimplugwise.com/supportplugwise.com/lisayoutube.com/plugwisePlugwise HomeNLVoorzorg en veiligheid Maak geen gebruik van het product als deze is beschadigd of niet goed funconeert. Breng het apparaat nooit in contact met water …
Lisa(2 pages) |
TOTALINE
Part Number P374-2300CONTENTSPageGENERAL ............................................2CONFIGURATION ....................................3-12Thermostat Display ....................................3Heat or Cool Indicator .................................4Thermostat Front Panel Buttons .........................4Thermostat Programming Buttons ................... …
SIGNATURE CPV230(20 pages) |
Lennox
Page 1INSTALLATIONINSTRUCTIONSML193UHE507863-0210/2021Supersedes 06/2020THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in man-uals, be alert to the potential for personal injury or death. CAUTIONAs with any mechanical equipment, contact with sha …
ML193UH030XE36B(54 pages) |
Minib
SAVETHESEINSTRUCTIONSGENERAL INFORMATION \ INSTALLATIONThe TH-0023 digital thermostat provides precisecontrol for variety of 2 and 4 pipes fan coil system,unit ventilators, dampers and other apparatus used incommercial or residential applications.This series features large LCD display, showingtemperature reading/setpoint, and variety ofconfiguration to meet …
TH-0023(2 pages) |
ecoteck Indoor Fireplace AmalfiPDF Guide (@EN7RPV), ecoteck Amalfi Indoor Fireplace (13.11.2023) Amalfi, 6 |
NETGEAR Modem JWNR2000v1Modem #99MQSW JWNR2000v1, 144 |
Goodmans Stereo System MICRO1103Stereo System Instruction manual (Goodmans MICRO1103) MICRO1103, 10 |
Power Fist Tools 8505547Power Fist Tools 8505547 Operation & user’s manual 8505547, 24 |
Art Amplifier HeadAmp4#XK8S42 HeadAmp4: Art Amplifier Owner Documentation HeadAmp4, 14 |
Singer Sewing Machine 246-13246-13 Parts list - G52B8J 246-13, 41 |
MILL Heater Oil Premium SeriesMILL Heater Oil Premium Series Assembly and instruction manual Oil Premium Series, 36 |
Toa Intercom System N-8000 SERIESToa N-8000 SERIES Guide (Operating instructions manual), @VI8R2P N-8000 SERIES, 652 |
Elephant Chain Hoists YA-80Elephant YA-80 Guide (Doc Type: Chain Hoists Operation manual) YA-80, 19 |
FATEK Control Unit CBEHFATEK Control Unit Manual (File: fatek-cbeh-manual-71, Fri 12.2023) CBEH, 71 |
SKF Lubrication systems TLAC 50/BSKF Lubrication systems TLAC 50/B User manual manual TLAC 50/B, 9 |
Oster Food Processor FPSTFP4263-DFL#IJ1Z67 FPSTFP4263-DFL: Oster Food Processor Owner Documentation FPSTFP4263-DFL, 46 |