Manualios.com

Marshalltown Company DUOFLEX HC125A Operation & User’s Manual

  • DUOFLEX HC125A Air Compressor
  • maj/fDSoRYFPM
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 32

Marshalltown Company DUOFLEX HC125A Manual Online:

4.9, 2358 votes
Marshalltown Company DUOFLEX HC125A User Manual
Marshalltown Company DUOFLEX HC125A User Guide
Marshalltown Company DUOFLEX HC125A Online Manual

Text of Marshalltown Company DUOFLEX HC125A User Guide:

  • Marshalltown Company DUOFLEX HC125A, 11200-2523 1. Turn the pressure switch to the OFF position (see A). 2. Open the petcock (see B). Turn in the counterclockwise direction. 3. Plug in the power cord. 4. Turn the pressure switch to the ON position (see C). The compressor will start. Allow the compressor to run for 30 minutes, to break in the internal parts. NOTE: After about 30 minutes, If the unit does not operate properly, SHUT DOWN IMMEDIATELY, and contact Product Service. 5. After about 30 minutes, turn the pressure switch to the OFF position. 6. Close the petcock (see

  • Marshalltown Company DUOFLEX HC125A, 200-252326 PARTS DRAWING / DESSIN DES PIÈCES / ESQUEMA DE LA PIEZAS Tighten compression nuts finger tight, then one complete turn on aluminum tubes and two complete turns on plastic tubes. Serrez le doigt d'écrous de compression fortement, alors on complet mettent en marche les tubes en aluminium et deux complets met en marche les tubes en plastique. Apriete el dedo de las tuercas de la compresión firmemente, entonces uno completo gira los tubos de aluminio y dos completos gira los tubos plásticos. Torque to 15-20 lbs-in Serrez de 15 à 20 lbs-in Torsión hasta 1,7 -

  • Marshalltown Company DUOFLEX HC125A, 17200-2523 Effectuez l’entretien suivant aux intervalles indiqués ci–dessous. Inspectez et nettoyez le filtre à air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Chaque jour Faites fonctionner les -soupapes de décharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Chaque jour Vidangez le réservoir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Chaque jour Perform the following maintenance at the intervals indicated below. In

  • Marshalltown Company DUOFLEX HC125A, 13200-2523 1. Placer le manocontacteur en position ARRÊT ( A). 2. Fermez le robinet de purge du réservoir (D). Tourner vers la droite. 3. Branchez le cordon d'alimentation. La pompe et le moteur électrique produisent des températures élevées. Pour éviter les brûlures et autres blessures, NE touchez PAS le compresseur quand il est en marche. Laissez-le refroidir avant de le manipuler ou d'effectuer son entretien. Ne laissez jamais les enfants s'approcher du compresseur. 4. Tourner le manocontacteur en position MARCHE (C). Pour passer d’une pressi

  • Marshalltown Company DUOFLEX HC125A, 200-252310 Ce produit doit être mis à la terre. En cas de court-circuit électrique, la mise à la terre réduit les risques de décharges électriques en fournissant un fil par lequel le courant électrique peut s'échapper. Ce produit est équipé d'un câble d'alimentation muni d'un fil de terre et d'une fiche de terre appropriée. Cette fiche doit être branchée sur une prise de courant qui à été mise à la terre et installée conformément à toutes les normes et décrets locaux. L'installation incorrecte de la fiche de terre risque de provoquer des décharges électriques. En cas de remplacement nécessaire du c

  • Marshalltown Company DUOFLEX HC125A, 200-252328 PARTS DRAWING / DESSIN DES PIÈCES / ESQUEMA DE LA PIEZAS Torque to 120-140 lbs-in Serrez de 120 à 140 lbs-in Torsión hasta 13,6 - 15,8 Nzm Torque to 110-130 lbs-in Serrez de 110 à 130 lbs-in Torsión hasta 12,4 - 14,7 Nzm Torque to 50-65 lbs-in Serrez de 50 à 65 lbs-in Torsión hasta 5,7 - 7,3 Nzm Torque to 145-155 lbs-in Serrez de 145 à 155 lbs-in Torsión hasta 16,4 - 17,5 Nzm

  • Marshalltown Company DUOFLEX HC125A, 5200-2523 ADVERTENCIA 1. Elimine la humedad del tanque todos los días. Un tanque limpio y seco ayudará a evitar la corrosión. 2. Tire del anillo de la válvula de alivio de la presión todos los días para asegurarse de que la válvula esté funcionando adecuadamente y para eliminar cualquier obstrucción en la válvula. 3. A fin de lograr una ventilación adecuada para el enfriamiento, el compresor debe mantenerse a un mínimo de 31 cm (12 pulgadas) de la pared más cercana, en una zona

  • Marshalltown Company DUOFLEX HC125A, 29200-2523 Item Part No Qty Art N o / P Qté Art Núm / P Cant Description Description Descripción 1 019-0186 1 Filter........................................Filtre.....................................Filtro 2 019-0192 1 Filter/intake muffler. ................Silencieux de Filter/intake....Silenciador de Filter/intake 3 061-0186 4 Screw 1/4-20 x 2-1/2” .............Vis........................................Tornillo 4 042-0104 1 Head .......................................Tête......................................Cabezal 5 054-0226 1 Head o-ring.............................Joint torique .........................Anillo t�

  • Marshalltown Company DUOFLEX HC125A, 15200-2523 To avoid personal injury, always shut off and unplug the compressor and relieve all air pressure from the system before performing any service on the air compressor. Regular maintenance will ensure trouble free operation. Your electric powered air compressor represents high quality engineering and construction; however, even high quality machinery requires periodic maintenance. The items listed below should be inspected on a regular basis. Condensation will accumulate in the tank. To prevent corrosion of the tank from the inside, this moisture must be drained at the end of every workday. Be sure

  • 200-25232 SAFETY GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . .3 OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Basic Air Compressor Components . . . . . . . . . . . . .6 COMPRESSOR CONTROLS . . . . . . . . . . . . . . . . . . . . . .7 ELECTRICAL POWER REQUIREMENTS . . . . . . . . . . . .9 Electrical Wiring . . . . . . . . . .

  • Marshalltown Company DUOFLEX HC125A, 7200-2523 ON/OFF Switch (see J) This switch turns on the compressor. It is operated manually, but when in the ON position, it allows the compressor to start up or shut down automatically, without warning, upon air demand. ALWAYS turn this switch to OFF when the compressor is not being used and before unplugging the compressor. Air Tool Pressure Regulator (see B). The air pressure regulator enables you to adjust line pressure to the tool you are using. Never exceed the maximum working pressure of the tool. Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure. Hopper Gun Pr

  • Marshalltown Company DUOFLEX HC125A, 19200-2523 Note: Troubleshooting problems may have similar causes and solutions. Contact authorized service center.Tank pressure exceeded normal operating pressure Contact authorized service center.Pressure switch stuck Motor will start automatically when tank pressure drops below kick-in pressure of pressure tank. Tank pressure exceeds preset pressure switch limit Let motor cool off and overload switch will automatically reset. This may take several minutes. Motor overload protection has tripped �

  • Marshalltown Company DUOFLEX HC125A, WARNING: Read this manual carefully before operating or servicing this air compressor to familiarize yourself with proper safety, operation and maintenance procedures. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY, PROPERTY DAMAGE, AND/OR VOIDING OF YOUR WARRANTY. MARSHALLTOWN WILL NOT BE LIABLE FOR ANY DAMAGE DUE TO FAILURE TO FOLLOW THESE INSTRUCTIONS. Following the instructions in this manual will provide a longer and safer service life for your air compressor. AVERTISSEMENT: Lisez attentivement ce manuel avant de faire fo

  • 200-252318 Note: Troubleshooting problems may have similar causes and solutions. Close petcockTank petcock is open Check fittings with soapy water. Tighten or reseal leaking fittings. DO NOT OVERTIGHTEN. Fittings Leak Clean or replace air filter element.Restricted air intake Decrease amount of air used.Prolonged excessive use of air Check air requirement of accessory. If i

  • 200-252312 1. Turn the pressure switch to the OFF position (see A). 2. Close the tank petcock (see D). Turn in the clockwise direction. 3. Plug in the power cord. High temperatures are generated by the electric motor and the pump. To prevent burns or other injuries, DO NOT touch the compressor while it is running. Allow it to cool before handling or servicing. Keep children

  • Marshalltown Company DUOFLEX HC125A, 23200-2523 Nota: Los problemas de detección de fallos pueden tener causas y soluciones similares. Comuníquese con un centro de servicio autorizado. Deje que el motor se enfríe, y el conmutador de sobrecargas se restablecerá automáticamente. Esto puede tardar varios minutos. La presión del tanque excedió la presión normal de operación SOLUCIONCAUSA POSIBLE El conmutador activado por presión se atoró El motor arrancará automáticamente cuando la presión del tanque disminuya hasta un valor menor de la presión de activación del conmutador activado por presión. La presión del tanque excede el l�

  • Marshalltown Company DUOFLEX HC125A, 200-252314 1. Coloque el conmutador activado por presión en la posición APAGADO (vea A). 2. Cierre la llave de descompresión del tanque (vea D). Hágalo girar hacia la derecha. 3. Enchufe el cordón eléctrico. El motor eléctrico y la bomba producen altas temperaturas. Para evitar quemaduras y otras lesiones, NO toque el compresor durante su funcionamiento. Permita que se enfríe antes de manipular o realizar el servicio. Mantenga a los niños alejados del compresor en todo momento. 4. Coloque el conmutador activado por presión en la posición ENCENDIDO (vea C). Al efectuar un ajuste desde una presión más alta a una más baja, gire la perilla a la izquierda hasta que sobr

  • 27200-2523 Item Part No Qty Art N o / P Qté Art Núm / P Cant Description Description Descripción 1 N/A 3 Screw, plastite 4-20 x 1” .....................Vis ...................................................Tornillo 2 142-0152 1 Shroud, right .......................................Enveloppe .......................................Guardera 3 N/A 1 Screw, plastite 4-20 x 2

  • Marshalltown Company DUOFLEX HC125A, 9200-2523 ELECTRICAL POWER REQUIREMENTS SPÉCIFICATIONS DE L'ALIMENTATION ÉLECTRIQUE Refer to the air compressor’s serial label for the unit’s voltage and amperage requirements. Use a dedicated circuit For best performance and reliable starting, the air compressor must be plugged into a dedicated circuit, as close as possible to the fusebox or circuit breaker. The compressor will use the full capacity of a typical 15 amp household circuit. If any other electrical devices are drawing from the compressor’s circuit, the compressor may fail to start. Low voltage or an overloaded circuit can result in sluggish starting that causes the motor overload

  • Marshalltown Company DUOFLEX HC125A, 200-252322 Nota: Los problemas de detección de fallos pueden tener causas y soluciones similares. Cierre el grifo de desagüe Disminuya la cantidad de aire usada. El grifo de desagüe del tanque está abierto SOLUCIONCAUSA POSIBLE Revise las conexiones con agua jabonosa. Apriete o vuelva a sellar las conexiones que tengan fugas. NO LAS APRIETE EN EXCESO. Las conexiones tienen fugas Limpie o reemplace el elemento del filtro de aire.Toma restringida de aire Uso excesivo y prolongado de aire Presión baja o insuficiente cantidad de aire. o bien el compresor no se detiene PROBLEMA Arranque y detenc

  • Marshalltown Company DUOFLEX HC125A, 200-25234 1. Vidangez tous les jours l'humidité accumulée dans le réservoir. Pour éviter la corrosion, le réservoir doit être propre et sec. 2. Tirez tous les jours sur l'anneau de la soupape de décharge pour vous assurer qu'elle fonctionne correctement et éliminer toutes les obstructions possibles de la soupape. 3. Pour assurer une ventilation correcte pour le refroidissement, le compresseur doit être placé à une distance minimum de 31 cm (12 pouces) du mur le plus proche, dans une zone bien aérée. 4. Pour éviter to

Related Products and Documents (Air Compressor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Clay Paky A.LEDA B-EYE K10 EASY Instruction manual clay-paky/a-leda-b-eye-k10-easy-SM1.pdf 20 Jan 2024 28 8.23 Mb
2 Acer TravelMate 8200 Manuel d'utilisation acer/travelmate-8200-35E.pdf 14 Jul 2022 100
3 Craftsman 917.275620 Owner's manual craftsman/917-275620-WSJ.pdf 29 Aug 2023 56 3.94 Mb
4 Panasonic HDC-TM41PC Owner's manual panasonic/hdc-tm41pc-8U2.pdf 21 Nov 2023 264 23.06 Mb
5 Nokia 770 - 770 Internet Tablet Guía del usuario nokia/770-770-internet-tablet-MLL.pdf 06 Feb 2023 54
6 BSS Audio Soundweb 9012 Installation manual bss-audio/soundweb-9012-ILX.pdf 09 Aug 2022 3 0.14 Mb

Similar Resources:

  • VIAIR

    00093

    (4 pages)
    IMPORTANT:It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product.SAVE THIS MANUAL FOR FUTURE REFERENCEUSER MANUAL90P PORTABLE COMPRESSORPOWER SPORT SERIESPART NO. 00093 …
  • Ariel

    JGW Series

    (141 pages)
    ARIELHeavy DutyBalanced OpposedCompressorsTECHNICAL MANUALFor Models:JGW, JGR and JGJARIEL CORPORATION35 BLACKJACK ROAD, MOUNT VERNON, OHIO 43050TELEPHONE: 740-397-0311 FAX: 740-397-3856VISIT OUR WEB SITE: www.arielcorp.comEMAIL: [email protected]: 1/01 …
  • Woodstar

    cp 16

    (48 pages)
    10-2010Art.-Nr. 390 6104 001cp 16DKompressor OriginalbetriebsanleitungGBCompressorTranslation from original manualFRCompresseur Traduction à partir de la notice originaleITCompressore Traduzione dal libretto d’istruzione originaleNLCompressor Vertaling van originele handleidingESCompresor Traducción de la instrucción de originalPTCompressor Tradução d …
  • Craftsman

    919.167370

    (43 pages)
    Owner’s ManualPermanently LubricatedTank MountedAIR COMPRESSOR• Safety Guidelines• Assembly• Operation• Maintenance• Service and Adjustments• Troubleshooting• Repair PartsModel No.919.167370CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating.Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.Visit our Cra …
  • Warm Audio

    WA76

    (2 pages)
    Thanks for purchasing a WA76 discrete compressor! This manual providesgeneral information and operating instructions. Enjoy your new sound!First off we invite you to experiment with your WA76 by selecting different Ratio settings, and by trying the “All-Buttons in” mode (pressing in all four Ratiobuttons simultaneously). The “All-Buttons in” mode a …
  • Craftsman

    919.167802

    (60 pages)
    i CRRFTSMRNqOil LubricatedTwo StageStationaryAIR COMPRESSORModel No.919.167802• Safety Guidelines• Assembly• Operation• Maintenance• Service and Adjustments• Troubleshooting• Repair PartsCAUTION: Read the Safety Guidelines andAll Instructions Carefully Before Operating.Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.Visit our Craftsman …

Comments, Questions and Opinions: