  • 2—3 Figure 2b Rear View of Model 3.1 With Optional Maintenance Bypass Assembly Figure 2c. Rear View of Model 4.5 With Optional Maintenance Bypass Assembly W CAUTION: High voltage present. Risk of electric shock. Do not remove cover. No user serviceable parts inside. Refer to qualified service personnel. ATTENTION: Présence de tension dangeruse. Risque de choc electrique. Ne

  • MGE UPS Systems Esprit, 5—8 Run Time Chart for Various Loads (in minutes) Model 25% Load 50% Load 75% Load 100% Load 1.4 193 96 55 35 3.1 65 32 18 13 4.5 49 22 12 8 6 65 32 18 13 9 49 22 12 8 13.5 49 22 12 8 Extended Battery Run Time Chart for Units at 100% Load (all times typical) Model 1.4 Qty. of batteries 1 2 3 4 5 6 Time min. (7.2 Ahr) 35 96 144 193 252 300 Hours 1.6 2.4 3.2 4.2 5 Model 3.1 Qty. of batteries 1 2 3 4 5 6 Time min. (7.2 Ahr) 13 33 58 92 115 142 Hours 1.5 1.9 2.4 Model 4.5 Qty. of batteries 1 2 3 4 5 6 Time min. (7.2 Ahr) 8 17 33 52 76 90 Hours 1.3 1.5 Model 6 Qty. of batteries 2 4 6 8 10 12 Time min. (7.2 Ahr) 13 33 58 92 115 142 H

  • MGE UPS Systems Esprit, For service call: 1-800-438-7373 MGE UPS SYSTEMS 1660 Scenic Avenue Costa Mesa, CA 92626 (714) 557-1636 www.mgeups.com Revision History Esprit User's Manual 86-153301-02 Copyright © 2000 MGE UPS Systems All rights reserved. Printed in USA Revision A00 New Release 03/00 Revision B00 ECN - 000975 03/01 Í ı ı Í www.mgeups.com battery module

  • 5—7 Sizing Guide Single UPS Power Cluster Esprit 1.4 ◗ 1-server protection ◗ 1-server protection ◗ 1.4 kVA ◗ 1.4 kVA ◗ 5U (in rack) ◗ 10U (in rack) ◗ Upgradeable to 2.8 kVA (with no redundancy) Esprit 3.1 ◗ 3-server protection ◗ 3-server protection ◗ 3.0 kVA ◗ 3.0 kVA ◗ 5U (in rack) ◗ 10U (in rack) ◗ Upgradeable to 6 kVA (with no redundancy) Esprit 4.5 ◗ 5

  • MGE UPS Systems Esprit, Rack Mounting Rack kits are available for optional rack mounting. Instructions for their use are included in the rack kit. See Figure 3b. Figure 3a. Stacked UPS and Figure 3b. UPS Modules Rack Mounted Battery Modules with Rack Kit (three 4.5s shown free-standing) (three 4.5s shown in rack) 3E. Optional Accessories The following accessories are available for use with your equipment. Refer to each accessories' manual for full installation, operation and maintenance instructions. ◗ Additional batteries (no additional manual nec

  • MGE UPS Systems Esprit, 7—1 7. Service & Maintenance 7A. Maintenance Clean the UPS with a dry cloth after turning off all power to the UPS and switching off the power switch. The UPS performs monthly automatic battery tests. However, it is recommended that a 6 month test be performed on the UPS for battery condition. Perform all tests off peak hours with applica- tions shut down. 1. Turn off power to the UPS via the branch circuit breaker to the UPS. It is not recommended to disconnect the plug from the UPS to the utility power due to disconnection of the safety ground. 2. Allow the UPS to run on battery power for 1 minute. Monitor the UPS for any fault LEDs and if none are observed, retu

  • MGE UPS Systems Esprit, 3—1 3. Installation 3A. Storing the UPS and Recharging the Battery Always store the equipment in its original packaging. The battery is of the sealed lead-acid type. Battery recharge requires that the battery module be plugged into an energized NEMA 5-15 receptacle for 6-8 hours. The battery may be charged in the box by pulling the charger cord out of the box through the knockout hole in the back of the box. Battery storage or prolonged shutdown should never exceed 6 months or 68°F (20°C), for a battery initia

  • MGE UPS Systems Esprit, 4—4 Off Flashing On 5. Utility Utility power is not Utility power is present but Utility power is present, stable Power connected to the UPS. is either unstable or the line and within acceptable voltage Present voltage is too high or too limits. In this state, the UPS (green) low to allow operation in will be operating on utility utility power mode. In this power mode. state, the UPS will normally be operating on battery power. 6. Inverter The UPS is not The UPS is operating

  • MGE UPS Systems Esprit, 6—2 It is possible to cycle backward through the configuration options by pressing and holding the top button. A given option setting can be forced to its factory default state by pressing and holding the bottom button. The middle (Power ON) button is not used in configuration mode. To leave configuration mode, simultaneously depress and hold in both the top and bottom buttons until the buzzer sounds and the AC PRESENT indicator stops flashing. Any changes made to the Esprit configuration will now be permanently saved. 6C. Configuration Options The table below lists the options that can be changed by the user in configuration mode, an

  • MGE UPS Systems Esprit, ^ 8—5 Supressores de Surto Eclipse Ellipse 300-1200 VA ESV+ UPS ESV+ Rack UPS 780-2200 VA 780-2200 VA EX UPS EX Rack UPS 700-3000 VA 700-3000 VA Para outras soluções de força, ligue para a MGE (714) 557-1636 ou (800) 523-0142  US MGE GREEN SWEEP Call MGE to return your UPS for free recycling to a US EPA-certified recycling center and help protect our environment. Other Fine MGE Products

  • MGE UPS Systems Esprit, 6—6 Option 15 – Power-On Inverter Test (POIT) When this option is set to the factory default ON setting, the Esprit will perform a short battery/inverter test shortly after it is turned on. This test is only performed only if the UPS is able to power up the load from utility power first. If the POIT is enabled, the UPS will power up the load from utility power, then briefly switch to battery power approximately 5-7 seconds after it is powered up. The UPS runs on battery for only 3-5 seconds, so no significant

  • MGE UPS Systems Esprit, 7—2 7B. Recycling Your UPS In USA or Canada, call 1-714-557-1636, M - F, 6:00 A.M. to 5:00 P.M. PST. Ask for a return goods authorization for free UPS or battery recycling. MGE does not cover return freight charges for recycling and will not accept items without a return goods authorization number. Í ı ı Í www.mgeups.com battery module

  • i Important Safety Instructions. Save These Instructions. This manual contains important safety instructions for the Esprit Models 1.4, 3.1, 4.5, 6, 9, and 13.5, that should be followed during installation and maintenance of the UPS and Batteries. Caution: Risk of electric shock, even with the unit disconnected from the AC power source. Hazardous voltages still may be present th

  • 1—1 Introduction Thank you for your purchase of the Esprit "UPS" from MGE. The Esprit "UPS" will provide many years of, trouble-free power protection for critical high availability servers and other devices. Please read this manual fully, to familiarize your- self with the safety instructions and Esprit fea- tures. MGE UPS Systems MGE, one of the largest UPS man

  • MGE UPS Systems Esprit, 3—5 3I. Connecting the UPS to the Utility Plug the AC line cord of the UPS module into an AC 2-pole, 3-wire grounded receptacle for models 1.4, 3.1 and 4.5; a 3-pole, 4-wire grounded receptacle for models 6 and 9; or a 4 pole, and hardwired 5 wire grounded service for model 13.5. There should be no other loads on this branch circuit. To do so may result in a circuit overload. Refer to National Electrical Code (NEC) specifications for requirements in your area or ask your electrician. Table 3a. UPS Wiring Information Figure 3f. AC Line Cord of the Battery Module(s) Model

  • MGE UPS Systems Esprit, 4—5 the user acknowledges the presence of the then-active system alarms. After an acknowledge sequence, any new alarms that occur will be brought to the user's attention by re-activating the alert beeper. 2. Long Top button press: Clears all active alarms and attempts to re-start the UPS on utility power. If the UPS is already operating on utility power, or operating on inverter because utility power is not present or not usable, then the alarms will be cleared but the restart-on-utility request will be ignored. If the cond

  • MGE UPS Systems Esprit, 4—2 4B. Initial Startup Tests and Diagnostics Your UPS will perform internal diagnostics as well as check utility power. After depressing the green "On" button and starting your UPS for the first time, you will hear an audible "beep" confirming the button has been depressed, and your UPS will perform the following diagnostic tests: 1. All front-panel LEDs will light, allowing visual confirmation that LEDs function properly. 2. UPS will confirm the integrity of factory calibration settings. FAULT indicator illuminates " " if internal settings

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Estun E21S Operation manual estun/e21s-E56.pdf 23 Aug 2022 20
2 Roberts Chronoplus 2 Manual  roberts/chronoplus-2-F16.pdf 10 Oct 2022 24 1.3 Mb
3 Munters EM36 Manual for use and maintenance munters/em36-P4G.pdf 17 Mar 2024 16
4 Winmate R17IH3S-MLA1-89 Operation & user’s manual winmate/r17ih3s-mla1-89-TSC.pdf 14 Mar 2024 90
5 Majestic fireplaces WMC36 WMC42 Operating manual cfm/wmc36-wmc42-EU4.pdf 31 Aug 2023 24 1.06 Mb
6 JBL PROCOUSTICS MS-2 Owner's manual jbl/procoustics-ms-2-W71.pdf 10 Jun 2023 8

Similar Resources:

  • HP

    UPS Network Module

    (88 pages)
    HP UPS Network Module User Guide Abstract This document includes installation, configuration, and operation information for the HP UPS Network Module. This document is for the person who installs and maintains power products. HP assumes you are qualified in the servicing of high-voltage equipment and trained in recognizing hazards in products with hazardou …
  • Xtreme

    M90-80 Series

    (75 pages)
    M90-80 & 140 Modular Online Three-Phase UPS15-140kVA ModelsUser & Installaon Manualwww.xpcc.com | © 2019 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 9/23/19) …
  • KOLFF

    Line Interactive 1000

    (2 pages)
    System DescriptionBack Panel --Front Panel --Trouble ShootingSpecificationFault LEDPower ON/OFF SwitchAC Mode-- Green LightingBackup Mode-- Green FlashingAC Mode-- Load Level LEDsBackup Mode-- Battery Capacity LEDsNEMAIECCommunicationPortCircuit BreakerModem/Phone LineSurge ProtectionCooling FanAC OutputAC InputCommunicationPortCircuit BreakerModem/Pho …
  • Eaton

    EX 1000

    (8 pages)
    Pow-R-Command  1000 — LCD DisplayQuick Start Guide Instruction Leaflet IL01412010E Effective June 2006 Introduction This is the Quick Start Guide for the PRC1000 LCD programming display. A worksheet of information that will be needed to complete this startup is found on Page 6 of this guide. Make sure you have all the listed information available b …
  • Pocasa

    H1KS

    (23 pages)
    1 H series online UPS LED 1-3KS/L UUUssseeerrr’’’sss mmmaaannnuuuaaalll PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn …
  • Tripp Lite

    OMNI1500LCD

    (6 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: OMNI1500LCDOmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port Highlights1500VA / 1.5kVA 2U rack/tower 120V line interactive UPS with LCD displayCorrects brownouts and overvoltages from 75V to 147VLCD scree …

Comments, Questions and Opinions: