  • MPI Technologies FCX,  ,167$//$7,21 The hole in the right rear of the unit is a large flat oval. Mount a Listed 2 x 4 inch, "HandiBox" type junction box over the oval hole in such manner that part of the hole is left open. When installing the junc- tion box, center the box vertically over the oval hole by using the center knockout in the box. Install a ½ inch trade size cable connector or insulating bushing in the knockout. Secure the box with screws as required. The open part of the oval hole can be either above or below the junction box depending upon the choi- ce o

  • MPI Technologies FCX,  923(5$7,1*)$8/76 During the course of seemingly normal operation, there may be operating faults experienced in the system. Some of the more common faults that may be encountered are: %851(5)$8/76+87'2:1 - The burner may shut down for any of several reasons, at which point the burner safety device light (red) on the control pa- nel will be ON and the there will be a green fault in- dicator light lit on the oil burner. This may be caused by a loss of fuel oil (tank empty?), a fouled oil spray nozzle in the burner, or perhaps a fouled or faulty flame sensor. To attempt a r

  • MPI Technologies FCX,  ,167$//$7,21 Various typical water circuits (cont) &RQQHFWLRQWRDGRXEOHKHDWLQJFLUFXLW &RQQHFWLRQWRDGRXEOHKHDWLQJFLUFXLWZLWKDGRPHVWLFKRWZDWHUSURGXFWLRQV\VWHP   )8(/2,/6833/<&211(&7,216 Flexible fuel oil supply and return lines are supplied with the unit, and connected to the oil burner. Lines are terminated with 3/8-inch reverse flare fittings for connection of the supply and return lines from the fuel oil tank. When connecting the lines, a 10-micron Ger

  •  ,1752'8&7,21   %2,/(523(5$7,21 Combustion air is drawn into the oil burner by the burner fan through the air intake hose connected to the coaxial flue/combustion air intake separator tube assembly. Heated air from combustion of the oil burner cools as it passes through the boiler heat exchanger, then the condenser. Cooled flue pro- ducts exit the unit throug

  •  67$5783$1'23(5$7,21   $'-867,1*7+(2,/%851(5 While the oil burner is adjusted at the factory, it is re- commended that the operating characteristics of the burner be determined at start-up and readjusted if necessary. Run the unit long enough at the burner maximum firing rate to make sure the burner has reached

  • MPI Technologies FCX,  ,167$//$7,21 7\SLFDOLQVWDOODWLRQH[DPSOHVFRQW Options: - 1 45 deg concentric elbow - 1 90 deg concentric elbow - Concentric extensions - 1 concentric vertical terminal - 1 sleeve tile roof flange - 1 roof plate Options: - 1 90 deg concentric elbow - 3 Concentric extensions - 3 45 deg concentric elbows - 1 concentric vertical terminal - 1 sleeve tile roof flange - 1 roof plate PD[/ /IWPIWP ≤IWP

  • MPI Technologies FCX,  ,,,67$5783$1'23(5$7,21   35(67$57),1$/6<67(0&+(&. Before starting normal operation of the boiler and heating system, perform the following final installa- tion procedures: • Leak-check the flue/combustion air system to minimize the likelihood of leakage. • Leak-check the entire water system, repairing any leaks that may be found. • Fill the entire water system with water, treated as desired for the application, including anti- freeze solution if a

  • MPI Technologies FCX,  ,167$//$7,21   )/8(&211(&7,216$1'5287,1* Connection of the coaxial flue/combustion air piping system is in the back of the unit to the separator tube assembly. The combustion products are ven- ted from the boiler and condenser through the cen- ter of the coaxial tube, while the combustion air is supplied through the outside ring of the coaxial tube. Since Model FCX is a condensing boiler, flue pro- ducts exiting the unit are relatively low temperature, from 140 - 185 deg. F (60 - 85 deg C), and saturated with humidity. Consequently, an airtight, corrosion resistant flue system must be provided. Various standard option flue

  • MPI Technologies FCX,  ,167$//$7,21 7\SLFDOLQVWDOODWLRQH[DPSOHVFRQW Options: - 1 90 deg concentric elbow - Concentric extensions - 1 concentric vertical terminal - 1 sleeve tile roof flange - 1 roof plate Options: - 1 90 deg concentric elbow - 3 Concentric extensions - 2 45 deg concentric elbows - 1 concentric vertical terminal - 1 sleeve tile roof flange - 1 roof plate PD[/ /IWP ≤IWP / / PD[/ /�

  •  7$%/(2)&217(176 ,  ,1752'8&7,21 

  • MPI Technologies FCX,  ,167$//$7,21 7\SLFDOLQVWDOODWLRQH[DPSOHVFRQW Options: - 1 45 deg concentric elbow - 2 90 deg concentric elbow - 1 concentric extension - 1 straight horizontal flue kit   &21'(16$7('5$,1&211(&7,21 Connection of the condensate drain piping system is to the back of the unit beneath the flue/combus- tion air separator tube assembly. The condensate drain tube provided in the unit is 1 - 19/32 inches (40 mm) O.D. to which the drain trap assemb

  • MPI Technologies FCX,  ,167$//$7,21   (/(&75,&$/&211(&7,216 :$51,1*(/(&75,&$/6+2&.+$=$5' ',6&211(&77+(32:(56833/<%()25($77(037,1*(/(&75,&$/ ,167$//$7,212)7+(81,7 Electrical power and control connections are made to pigtail leads that exit through a hole in the right rear of the unit (facing the front of the unit). The power connections must be made in a Listed junction box that is not provided with the unit. All wi- ring should

  • MPI Technologies FCX,  ,,,167$//$7,21   23(1,1*7+(81,7 To open Model FCX to access for installation, and/ or service, follow these steps : - Remove the control panel escutcheon molding (2) by grasping it on both sides and pulling it outward towards you and up. The escutcheon will come free of the attachment clips leaving the con- trol panel exposed. - Remove the top cover of the unit (A) by lifting the cover at the front and rear to free the attachment clips, and then simply lift the cover straight

  • MPI Technologies FCX,  ,167$//$7,21 6OHHYH7LOHZLWK$GDSWDEOH&RXSOLQJ 3RO\SURS\OHQH39&&RQFHQWULF(OERZ - joint fitting - )DVWHQLQJFROODURSWLRQ Collars are essential to bear the weight of the verti- cal extensions so that the boiler does not bear the weight. 3RO\SURS\OHQH5RRI3ODWH 5HIHUHQFH 6ORSH &RYHULQJ W\SH &RORU N40.12165 25 - 45 deg Tile Tile N40.12166 35 - 55 deg Tile Tile N40.12167 35 - 55 deg Slate - Shingle Black 5HIHUHQFH &RORU ,' 2' N40.28395 45 deg 3.15 inch (80mm) 4.92 inch (125mm) N40.28396 90 deg 3.15 inch (80mm) 4.92 in

  • MPI Technologies FCX,  ,,1752'8&7,21   352'8&7'(6&5,37,21 Model FCX oil fired boiler utilizes a sealed combus- tion system that operates at a temperature at which the flue products will condense. The flue products temperature is so low that the unit is suitable for use with PVC / Polypropylene flue pipes, which are offe- red as standard options for installation. Model FCX is approved for installation with zero clearance to combustible materials by Intertek Testing Services to the

  • MPI Technologies FCX,  0$,17(1$1&(   &+$1*,1*$7+(50267$7257+(7+(5020(7(5 Replacement of the thermostats or the thermometer requires removal of the bulb from its location and the control from the control box. • The bulb for the Boiler Temperature Thermo- meter is located on the first circuit heating out- put tube. Remove the bulb from the tube, remove the thermometer mounting screws in the control box and remove the thermometer. Replace the thermometer with another, routing the bulb capilla

  • MPI Technologies FCX,  ,1752'8&7,21 '(6,*1$7,212)&20321(176 2 3 10 1 4 5 6 7 8 9 11 12 13 14 15 8 17 18 19 20 21 22 2 3 1 14 1718 192021 22 23 24 16 25 26  &RQWURO3DQHO  &RQWURO3DQHO&RYHU  6DIHW\3UHVVXUH5HOLHI9DOYH  &RQGHQVHU  0DQXDO0L[LQJ9DOYH  &RPEXVWLRQ3URGXFW3UHVVXUH7HVW3RLQW  &RQGHQVHU,QVSHFWLRQ3RUW  &RQGHQVDWH'UDLQ  'UDLQ&a

  • MPI Technologies FCX,  ,90$,17(1$1&( It is recommend that the boiler and flue/combustion air system be inspected and maintained annually by a qualified technician. ',6&211(&7$//(/(&75,&$/&,5&8,76%()25(6(59,&,1*7+(81,7 &/26($1<,62/$7,219$/9(67+$70$<%(,17+(:$7(56<67(0 6+872))7+()8(/2,/6833/<,)6(59,&,1*7+(%851(5 To gain access to the inside of the unit, first remove the control panel cover escutcheon by

  • MPI Technologies FCX,  ,167$//$7,21 7\SLFDOLQVWDOODWLRQH[DPSOHV The flue/combustion air system piping may be either horizontal or vertical or a combination of both, ob- serving the following: • The maximum unrestricted horizontal or verti- cal flue length shall not be more than 16.4 ft (5 m). • For each 90-degree elbow used in the flue sys- tem, subtract 3.3 ft (1m) from the total allowa- ble length. • For each 45-degree elbow used in the flue sys- tem, subtract 1.65 ft (0.5m) from the total allo- wable length. • Horizontal runs of t

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LEGO 6868 Avengers Super Heroes Operation & user’s manual lego/6868-avengers-super-heroes-5WG.pdf 20 Mar 2023 84
2 Sears Kenmore Side by Side Refrigerator Use & care manual sears/kenmore-side-by-side-refrigerator-9YO.pdf 30 Jan 2023 104 14 Mb
3 Frigidaire PLHT189SS Factory parts catalog frigidaire/plht189ss-GR6.pdf 18 Jan 2024 13
4 GE JGAS02EK Use and care manual ge/jgas02ek-R1Z.pdf 31 Jan 2024 20
5 Powermate PE0401853 Operation & user’s manual powermate/pe0401853-KUL.pdf 20 Mar 2023 12
6 Akura APL21621W HDID Operation & user’s manual akura/apl21621w-hdid-P4Z.pdf 11 Aug 2022 23 2.26 Mb

Similar Resources:

  • Biasi

    Advance Plus 25C ERP

    (88 pages)
    Wall hung, fanflue, roomsealed, high efficiency gas boilerUser manual andInstallation instructionsAdvance Plus ERPModels G.C. Appl. No.Advance Plus 25C ERP 47-583-35Advance Plus 30C ERP 47-583-36Advance Plus 35C ERP 47-583-37 …
  • Lennox

    OWB86-4D

    (28 pages)
    RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCEThese instructions must be axed on or adjacent to the boiler. PN 240013016, Rev. B [12/31/2020]INSTALLATION INSTRUCTIONSPRODUCT LITERATURELennox Industries Inc.Dallas, TexasTested For 50 psi.ASMEWorking PressureWARNINGImproper installation, adjustment, alteration, service, or maintenance could result in dea …
  • gledhill

    BMA 120 SP

    (46 pages)
    DESIGN, INSTALLATION AND SERVICING INSTRUCTIONSTEL: 0800 14 55 55 7www.gledhill-boilermate.co.ukAN SEALED CENTRAL HEATINGAND MAINS PRESSURE HOT WATER SUPPLYSYSTEM INCORPORATINGA THERMAL STOREALL MODELS COMPLY WITH THEWATER HEATER MANUFACTURERSSPECIFICATION FOR INTEGRATED THERMAL STORESBOILERMATE A CLASS SPGas Council Approved Reference Numbers89-317-14 / BM …
  • Lochinvar

    KNIGHT KBN-RP-08

    (4 pages)
    KnightHeating BoilersKB 80 thru 285KBN-RP-08 Replacement Parts ListPARTS & SERVICE DEPARTMENTNashville, Tennessee615-889-8900 / Fax: 615-547-1000www.Lochinvar.com …
  • Dunkirk

    XEB-2

    (36 pages)
    INSTALLATION MANUALDUNKIRK BOILERS85 Middle Rd.Dunkirk, NY 14048www.dunkirk.comAn ISO 9001-2000 Certied Company P/N 14683001, Rev. 2.1 [02/08]XEB SErIES GAS-FIrEd HOT WATEr INdUcEd drAFT BOILErS …
  • Radiant

    RK 18

    (8 pages)
    User instruction CE 0694 RK 18_25_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification by RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH User Manual for model RK 18 …

Comments, Questions and Opinions: