Manualios.com

NCR 7870 Operation & User’s Manual

NCR 7870 Manual Online:

4.1, 2528 votes
NCR 7870 User Manual
NCR 7870 User Guide
NCR 7870 Online Manual

Text of NCR 7870 User Guide:

  • NCR 7870, Chapter 7: Programming 7-69 EAN/JAN/UPC Multi-Symbol Scanning Parameters The optional Multi-Symbol programming feature permits you to scan bar code labels containing two or three EAN-13, JAN-13, or UPC-A symbols. Label Construction A multi-symbol label must consist of any combination of two or three EAN-13, JAN-13, or UPC-A symbols, each with different flag digits. Flag digits are the first two digits of the symbol on EAN-13/JAN-13 symbols. Flag digits for UPC-A symbols always have a zero (0) for the first digit with the number system charac

  • NCR 7870, Chapter 7: Programming 7-27 Program Example Following is an example of a completed Bar Codes 2 programming worksheet. In this example, Code 39 is enabled with the following options. • Code 39 – enabled • Minimum Characters Allowed – 5 • Full ASCII – disabled • Check Digit Present – enabled • Transmit Check Digit – enabled • Allow One- or Two-Character Tags – disabled Your Program Bar Codes - 2 1 4 A Code 39 1 Minimum Characters Allowed B 5 Full ASCII C 0 Check Digit Present D 1 Transmit Check Digit E 1 Allow Single F 0 Character Tags R0068

  • NCR 7870, Chapter 8: Troubleshooting 8-3 Scale Troubleshooting Chart Note: This information does not apply to the NCR 7870-4000 which uses a Bizerba scale. For information on troubleshooting or servicing an NCR 7870-4000 scale unit, refer to the Bizerba documentation or contact the Bizerba representative. Problem Possible Cause Corrective Action Error code 5 - - - - displays Scale drift 1. Verify nothing is on scale. 2. Lift Top Plate and verify no objects are under it. 3. Push Reset/Scale Zero button. 4. Po

  • NCR 7870, 7-8 Chapter 7: Programming Programming Mode Function This tag puts the NCR 7870 in the Base Programming State. It must be the first tag scanned after applying power to the NCR 7870, or after scanning the Default tag. Indication • Short beep as soon as tag is read – Good Read tone • Long and short beep – in Base Programming State • Status indicator – off Save and Reset Function This tag causes the NCR 7870 to save and start using the programming data. It is used in the Base Programming State. Indication • Short beep as soon as tag is read – Good Read tone • Status indicator flashes red twice • Four quick beeps from low to high frequency

  • NCR 7870, Chapter 5: Calibration 5-15 Procedure 4: Shift Test This test consists of measuring a weight in the center and four positions on the Top Plate. 2 34 5 1 11033 Instructions 1. Place a 15.00 lb (or 5.000 kg) weight in Position 1 and record measured weight. 2. Move sequentially to Positions 2, 3, 4, and 5. Record measured weight for each position. 3. Move weight back to Position 1 and record measured value. 4. All measurements should fall within • 15.00 lb ± 0.01 lb (for 30.00 lb scales) • 5.000 kg ± 0.005 kg (for 9.995 and 13.995 kg sca

  • Chapter 7: Programming 7-23 this parameter. The default is None and scanning a valid Hex tag ends the input for this parameter option. Extend UPC-A to EAN-13 The Extend UPC-A to EAN-13 parameter determines whether to pad the tag data, changing 12-digit UPC tags to 13-Character EAN tags. The program does this by putting a zero (0) at the front of the tag data. Scan th

  • NCR 7870, A-14 Appendix A: Programming Worksheets Your Program 02 RS-232 Parameters - 1 B Parity D Handshake A Baud Rate Stop Bits And Character Length C 2 0 RS-232 PARAMETERS - 1 A B C D Baud Rate 0 300 1 600 2 1200 3 2400 4 4800 5 9600 6 19200 Parity 0 Odd 1 Even 4 None Stop Bits And Character Length 0 1 Stop Bit 7-Bit Character 1 1 Stop Bit 8-Bit Character 2 2 Stop Bits 7-Bit Character 3 2 Stop Bits 8-Bit Character Handshake 0 RTS Low CTS Ignored 1 RTS High CTS Ignored 2 Raise RTS Wait for CTS Raise RTS Ignore CTS RTS Low Wait for CTS 3 4 5 RTS High Wait for CTS 11809 Note: On a 7870-2000, 4000, or 4500, Parity must be Odd or Even. If None is s

  • NCR 7870, Chapter 4: Installation 4-9 Checkout Reading Operation To check the tag reading operation of the NCR 7870, attempt to read a good tag on an item. The Status indicator turns red when the NCR 7870 is ready to scan a label. A good read is indicated when the Status indicator turns green and a tone sounds (if enabled). Programming Your NCR 7870 comes from the factory with the programming parameters set to default values. The Communications Protocol is set to the specifications on your order. However,

  • NCR 7870, 3-26 Chapter 3: Site Preparation Interface Cables – Data Checker Host Terminals Minimum Hole Diameter: 1.90 cm (0.75 in.) Host Terminal Interface Cable Corporate ID Part Number Length 2200 MDL/ Datachecker Single-Cable 1416-C144-0040 497-0301889 4 m (13.1 ft.) T2001 MDL/ Datachecker Single-Cable 1416-C062-0040 497-0301152 4 m (13.1 ft.) Interface Cables – Epson Host Terminals Minimum Hole Diameter: 1.90 cm (0.75 in.) Host Terminal Interface Cable Corporate ID Part Number Length Epson PC RS-232 Single-Cable 1416-C357-0040 497-0408212 4 m (13.1 ft.) Interface Cables – Gi

  • 7-10 Chapter 7: Programming 11722 BASE PROGRAMMING STATE Code 39 Bar Codes - 2 Full ASCII Minimum Characters Allowed Check Digit Present 10 Disable Enable Transmit Check Digit 01 Disable Enable 01 Disable Enable 1 0 Disable Enable 2-F 4 1 Allow Single Character Tags 0 1 Disable Enable b) Enter Specific Parameters To enter only one particular parameter in a Specific Programming Mode, scan t

  • NCR 7870, 3-16 Chapter 3: Site Preparation Service Clearance The 7870 is designed to allow servicing without removal from the checkstand. This includes component removal and replacement, scale calibration, and installation of the Weights and Measures seal. To take advantage of this design feature, an area for service clearance must be provided. Note: Access to the Power Supply may require removal of the 7870 from the checkstand. A = 20.3 cm (8.0 in.) minimum if checkstand structure is not removable for servicing. 2.5 cm (1.0 in.) minimum if checkstand structure is removable for servicing. B = 33.0 cm (13.0 in.) minimum if checkstand structure is not removable for servici

  • 8-2 Chapter 8: Troubleshooting Scanner Troubleshooting Chart Problem Status Indicator Tone Possible Cause Corrective Action Scanner does not operate Red Off Green Off Off No power Check outlet for proper power Scanner does not operate Red Flashing Green Flashing Off Sleep mode Pass anything in front of Motion Detector Scanner does not operate Red Flashing Off Communication

  • NCR 7870, Chapter 4: Installation Getting Started This chapter describes the installation process for the NCR 7870. Before installation, prepare the site in accordance to the requirements in Chapter 2 – Site Preparation. The first step is to perform an inspection to verify that the unit and checkstand are ready. Reporting a Damaged Unit Upon receiving an NCR 7870, inspect the shipping for damage. If the carton is damaged, open it in the presence of the shipping carrier before signing the bill of lading. If the scanner/scale has been damaged due to shipping, notify t

  • NCR 7870, 7-52 Chapter 7: Programming Program Example Following is an example of a completed RS-232 Communications Options programming worksheet. This example shows the following programming selections. • Message delay – 10 ms • Format – Scanner only • Normal or Eavesdrop – Normal Mode • Scale Weight Transmission - Beep Your Program 12164 24 RS-232 Communications Options Message Delay A Scanner or Scanner/Scale Format B Normal or Eavesdrop Mode C Beep/No Beep Scale Weight Transmission D

  • NCR 7870, Index —A— Abort Tag, 7-6 Accessing Calibration Switch, 5-4–5-6 ASCII Code Chart, 7-77 Auto-Zero, 2-11 —B— Bar Codes Quality, 6-6 Recognition, 2-1 Bar Codes - 1 Parameters, 7-22–7-24 Bar Codes - 2 Parameters, 7-25–7-27 Bar Codes - 3 Parameters, 7-28–7-30 Bar Codes - 4 Parameters, 7-31–7-32 Bi-Optic Scanning, 2-2 —C— C E Mark Applicability, xii Cables, 3-21–3-26 AC Power, 3-22 DC Power, 3-21 Hole Diameters, 3-21 Interface, Casio, 3-25 Interface, Data Checker, 3-26 Interface, Epson, 3-26 Interface, Gilbarco, 3-26 Interface, IBM, 3-27 Interface, IC

  • 7-68 Chapter 7: Programming Special Programming Some of the NCR 7870 features require programming that is somewhat different than the normal programming. Delay Weight Data to IBM Host Terminal A timing condition is possible when the NCR 7870 Scanner/Scale communicates with an IBM host terminal. The condition occurs when the IBM Host is requesting weight data, but the scale is not settled. To

  • NCR 7870, Chapter 2: Features, Functions, and Kits 2-11 Scale Features and Functions The scale is used in the 2000, 4000, and 4500 models. It can be manufactured by NCR or by a vendor for a specialized market such as the price-computing scale in the 4500 model to meet European standards. Scale Functions and Features Load Cell The NCR 7870 uses a single load cell rather than four, which is more typical, to increase reliability. The scale has a settling time of 0.9 seconds for items weighing less than 2.3 kg (5 lbs.) It is sealed to avoid damage from spills around the unit. There are three basic types of load cells: • For weighing in p

  • 2-8 Chapter 2: Features, Functions, and Kits Scan Zone The scan lines are dispersed in a forward and backward direction from both windows. This allows the scanner to read a) on four sides, b) from left-to-right or right-to-left, and c) inverted labels. If the scan zone is thought of as a cube resting on the horizontal scan window, the scanner is able to rea

  • NCR 7870, Chapter 2: Features, Functions, and Kits 2-5 No Display If the 7870 is ordered with no display, the scale information is usually displayed on the host terminal display. Please note, the host terminal must be approved to perform a live/gross scale weight. This arrangement is not available in all host terminals and some Weight and Measures authorities do not permit this arrangement. Interface Types The NCR 7870 communicates with the host terminal through various types of interfaces. The 7870 Scanner always uses one interface cable. However, some host terminals require dual cables for and NCR 7870 Scanner/Sca

  • NCR 7870, 7-32 Chapter 7: Programming Program Example Following is an example of a completed Bar Codes 4 programming worksheet. In this example the Code 128 bar codes are programmed for the following. • Code 128 – enabled • Minimum Data Characters Allowed – 3 • UCC 128 – disabled Your Program A B 1 7 Code 128 Minimum Data Characters Allowed UCC 128 C 13 0 11808 Bar Codes - 4

  • NCR 7870, Index-4 RS-232 Parameters -1, 7-41 RS-232 Prefix Byte Parameters, 7-45–7-46 RS-232 Terminator Byte Parameters, 7- 47–7-48 —S— Save and Reset Tag, 7-8 Scale Functions and Features, 2-11 Auto-Zero, 2-11 Load Cell, 2-11 Reset / Scale Zero, 2-11 Market Certifications, 2-7 Regulatory, xii Troubleshooting, 8-3 Weighting Procedure, 6-9 Scale Calibration, 5-1, 5-2 Scale Parameters, 7-53–7-54 Scan Windows, 6-2 Maintenance, 6-11 Side Scan Window Kit for, 2-12 Slot Scan Window Kit for, 2-12 Scanner Active Scan Zone, 6-5 Bar Code Quality, 6-6 Bioptic, 2-2 Description, 2-5 Multiple Reads, 6-5 Power Requirements, 2-8 Sca

  • NCR 7870, Chapter 5: Calibration 5-11 Verifying Calibration This section describes how to verify that the 7870 has been properly calibrated. No error codes should appear during calibration. The codes are shown in the table below. If a code is displayed, the calibration is invalid and a corrective action must be undertaken before attempting recalibration. Error Code Problem Suspect Component 1 - - - - Calibration error A/D output below 000h at digital to analog converter Scale Board Load Cell 2 - - - - Calibration error A/D output below

Related Products and Documents (Scanner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 VTech LS5146 Important s Quick start manual vtech/ls5146-important-s-VBA.pdf 26 Jun 2023 2 1.45 Mb
2 Saris 801 Owner's manual saris/801-8KU.pdf 06 Jul 2022 2 0.34 Mb
3 Sylvania SB374W Owner's manual sylvania/sb374w-2ES.pdf 14 Jun 2023 11
4 SMC Sierra Monitor FieldServer FS-8700-22 Driver manual smc-sierra-monitor/fieldserver-fs-8700-22-AO4.pdf 05 Jan 2023 12
5 Philips AZ1008 Service manual philips/az1008-SY2.pdf 14 Apr 2023 24
6 Samsung SyncMaster 794MB, 794MB+, 798MB, 796MB, 796MB+ Manual del usuario samsung/syncmaster-794mb-794mb-798mb-796mb-796mb-ZI8.pdf 24 Jul 2022 117 4.03 Mb

Similar Resources:

  • Canon

    imageCLASS MF6500 Series

    (173 pages)
    ENGBasic GuidePlease read this guide before operating this equipment.After you finish reading this guide, store it in a safe place for future reference.Before Using the MachineDocument HandlingPrint MediaSending Faxes (MF6550 Only)Receiving Faxes (MF6550 Only)CopyingPrintingScanningPC Faxing (MF6550 Only)TroubleshootingMachine SettingsAppendixMaintenanceSeri …
  • BEA

    LZR-H100

    (16 pages)
    75.5984.01 LZR-H100 20181221 Page 1 of 175.5984.01 LZR-H100 20181221 Page 1 of 1LZR®-H100ENLASER SCANNER FOR BARRIERS & GATESwith max. detection range of 32’ × 32’ User’s Guide Visit website for available languages of this document. …
  • Chiphandel

    F1

    (2 pages)
    Chiplesegerät F1 Gebrauchsanleitung Der F1 Reader zeichnet sich durch besonders einfache Handhabung aus. Die eingescannten Transpondernummern werden automatisch im geräteinternen Speicher abgelegt. Durch Verbindung des Gerätes über das Mini-USB-Kabel mit dem PC können die Nummern ganz ohne Zusatzsoftware ausgelesen werden, da das Gerät als USB-Speich …
  • Konica Minolta

    bizhub C654

    (158 pages)
    This guide describes basic machine procedures and setting methods used to configure each function. It introduces important functions that make it easier to use this machine.This guide also contains notes and precautions that should be followed in order to use this machine.Quick Start Guide …
  • Ambir

    TravelScan PS600

    (1 pages)
    TravelScan Pro 600Use the portable sheet-fed TravelScan Pro 600 to easily scan and digitally capturedocuments, photos, or ID cards. Weighing only 12.2oz., this small footprint simplexscanner is USB powered, eliminating the need for an AC adapter. The TravelScan Pro 600 captures high-resolution color images at 600dpi and scans a full page in just 15 second …
  • Canon

    CANOSCAN D660U

    (6 pages)
    Carefully remove all itemsfrom the box. Gently turn the scanner on its sideand unlock the scanner ( ). Caution! Be sure to unlock the scanner before plugging in the USBinterface cable. Operating the scannerwhile in the locked position maydamage the equipment.Note: Before you begin, make sureyou’ve turned on the computer andhave quit all applications.Locate …

Comments, Questions and Opinions: