Manualios.com

Porter-Cable JOB BOSS CFFC350B Instruction Manual

Porter-Cable JOB BOSS CFFC350B Manual Online:

3.25, 673 votes
Porter-Cable JOB BOSS CFFC350B User Manual
Porter-Cable JOB BOSS CFFC350B User Guide
Porter-Cable JOB BOSS CFFC350B Online Manual

Text of Porter-Cable JOB BOSS CFFC350B User Guide:

  • Porter-Cable JOB BOSS CFFC350B, Oilfree Portable Air Compressor Instruction manual IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. Part No. A01787-0312-0 ESPAÑOL: PÁGINA 25 FRANÇAIS: PAGE 49 To learn more about Porter-Cable visit our website at: http://www.porter-cable.com Copyright © 2001 Porter-Cable Corporation The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference. Model No. Type Serial No. MODELS CFFR350B CFFC350B

  • Porter-Cable JOB BOSS CFFC350B, 2- ENG A01787 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in pr operty damage. This manual contains information that is important for you

  • Porter-Cable JOB BOSS CFFC350B, 3- ENG A01787 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire How To Prevent It What Could Happen It is normal for electrical contacts within the motor and pressure switch to spark. If electrical sparks from compressor come into contact with flammable vapors, they may ignite, causing fire or explosion. Restricting any of the compressor ventilation openi

  • Porter-Cable JOB BOSS CFFC350B, 4- ENG A01787 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. How To Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles, and small objects at high speed, resulting in property damage or personal injury. Always wear ANSI Z87.1 approved safety glasses with side shields when using the compressor. Never point any nozzle or sprayer toward any part of the body or at other people or animals. Always turn the compressor

  • 5- ENG A01787 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Grounding: Failure to pro

  • Porter-Cable JOB BOSS CFFC350B, 6- ENG A01787 WARNING: Risk of Burns Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool. WARNING: Risk from Moving Parts Never operate the compressor with guards or covers which are damaged or removed. Moving parts such as the pulley, flywheel, and belt can cause serious injury if they come into contact with you or your clothing. WA

  • Porter-Cable JOB BOSS CFFC350B, 7- ENG A01787 Review and understand all instructions and warnings in this manual. Become familiar with the operation and controls of the air compressor. Keep operating area clear of all persons, pets, and obstacles. Keep children away from the air compressor at all times. Do not operate the product when fatigued or under the influence of alcohol or drugs. Stay alert at all times. Never defeat the safety features of this product. Equip area of operation with a fire extinguisher. Do not operate machine with missing, broken, or unauthorized parts. WARNING: Risk of Unsafe Operation Unsafe operation of your air compr

  • Porter-Cable JOB BOSS CFFC350B, 8- ENG A01787 GLOSSARY Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety. Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accesso

  • Porter-Cable JOB BOSS CFFC350B, 9- ENG A01787 INSTALLATION HOW TO SET UP YOUR UNIT GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. 1. The cord set and plug with this unit contains a gro

  • Porter-Cable JOB BOSS CFFC350B, 10- ENG A01787 Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed. If an extension cord must be used, be sure it is: • a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the prod

  • 11- ENG A01787 Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch (A): Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use. Pressure Switch (B): The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pres

  • Porter-Cable JOB BOSS CFFC350B, 12- ENG A01787 Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled. Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet. Drain Valve(I): The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Air

  • Before Starting Break-in instructions Serious damage may result if the following break-in instructions are not closely followed. This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the On/Auto/Off lever is in the "OFF" position. NOTE: If quick connect is installed, pull coupl

  • Porter-Cable JOB BOSS CFFC350B, How to Use Remote Console: When needed the remote console allows remote air regulation and control closer to the work area. Reduce air pressure in tank to 60 psi maximum before removing or connecting portable control panel and when connecting hose to tank quick-connect coupler. 1. Turn knobs counter clockwise to loosen knobs securing control panel. 2. Slide console up and away from frame, disconnect air hose from quick connect (a), and remove console. 3. Connect air hose (sold separately) to quick connect plug (b) and quick connect (a). The console can then be brought closer

  • Porter-Cable JOB BOSS CFFC350B, 15- ENG A01787 How to transport unit The unit has a handle (a) for carrying and a handle (b) for pulling. 1. Grasp carrying handle (a) to lift unit. 2. Slide handle (b) out until it locks into place. 3. Pull unit as shown, do not push unit. NOTE: When transporting do not lift the unit to the point where it would tip over backwards. IMPORTANT: Only use pulling handle to pull unit, use the carrying handle to lift and carry unit. a a b b

  • 16- ENG A01787 MAINTENANCE Customer Responsibilities Daily or after each use Before each use ● ● Yearly ● 1 1- more frequent in dusty or humid conditions Check Safety Valve Drain Tank Air Filter NOTE: See "Operation" section for the location of controls. To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance

  • Porter-Cable JOB BOSS CFFC350B, 17- ENG A01787 Air Compressor Pump Intake and Exhaust Valves Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves. Air Filter Inspection and Replacement Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compressor to cool prior to servicing. Keep the air filter clean at all times. Do not operate the air compressor with the air filter removed. A dirty air filter will not allow the compressor pump to operate at full ca

  • 18- ENG A01787 To Replace or Clean Check Valve 1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. 2. Unplug outfit. NOTE: If needed the top panel may be removed to make parts accessible. 3. Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outlet tube away from check valve. 4. Using an adjustable wrench

  • Porter-Cable JOB BOSS CFFC350B, 19- ENG A01787 STORAGE Before you store the air compressor, make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the On/Auto/Off lever to "OFF". 3. Turn the regulator counterclockwise and set the outlet pressure to zero. 4. Remove the air tool or accessory. 5. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 6. Drain water from air tank by opening drain valve

  • Porter-Cable JOB BOSS CFFC350B, 20- ENG A01787 TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION Pressure switch does not shut off motor when compressor reaches "cut-out" pressure. Pressure switch "cut-out" too high. Move On/Auto/Off lever to the "OFF" position, if the outfit does not shut off contact a Trained Service Technician. Contact a Trained Service Technician. Excessive tank pressure - safety valve pops off. Tube

  • Porter-Cable JOB BOSS CFFC350B, 21- ENG A01787 PROBLEM CAUSE CORRECTION It is normal for "some" pressure drop to occur. If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Section. NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used). Possible defect in safety valve. Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Defective check valve. Remove and clean, or replace. Knocking Noise. Compressor is not supplying enough air to operate accessories.

  • Porter-Cable JOB BOSS CFFC350B, 22- ENG A01787 Regulator will not shut off air outlet. Damaged regulator. Replace. PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit breaker tripped. 1. Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. 2. Check for proper fuse. You should use a time delay fuse. 3. Check for low voltage conditions and/or proper extension cord. 4. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit. Motor overload protect

  • Porter-Cable JOB BOSS CFFC350B, 24- ENG A01787 LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM. 2 YEARS - Limited warranty on oil-lubricated air compressor pumps. 1 YEAR - Limited warranty on all other air compressor components. 2 YEARS - Limited warranty on electric generator alternators. 1 YEAR - Limited warranty on other genera

Related Products and Documents (Air Compressor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LEGO 10695 Assembly instruction manual lego/10695-867.pdf 03 Apr 2024 55
2 Sonnet FUSION F3 Operation & user’s manual sonnet/fusion-f3-R1G.pdf 15 Oct 2022 8 0.88 Mb
3 Eddylight DSY-LED252-IP65-RGB Operation & user’s manual eddylight/dsy-led252-ip65-rgb-532.pdf 19 Nov 2022 8
4 Crown IQ-RPT 3 Specifications crown/iq-rpt-3-55P.pdf 21 Oct 2022 1 0.06 Mb
5 Intel 430TX Operation & user’s manual intel/430tx-S1K.pdf 16 May 2023 65
6 Si-tex CVS-106L Operation manual si-tex/cvs-106l-756.pdf 30 Mar 2024 26

Similar Resources:

  • EINHELL

    TH-AC 190/6 OF

    (80 pages)
    TH-AC 190/6 OFArt.-Nr.: 40.204.95 I.-Nr.: 110127D Originalbetriebsanleitung KompressorGB Original operating instructions CompressorF Mode d’emploi d’origine CompresseurI Istruzioni per l’uso originaliCompressoreS Original-bruksanvisningKompressorNL Originele handleidingCompressorFIN Alkuperäiskäyttöohje KompressoriSLO Originalna navodi …
  • Airpress

    LMO 50-270 Silent

    (24 pages)
    Oil Free Air CompressorEN FR DE PL RU NL uInstruction man al for owner’s use (Translation of the original instructions) Traduction des instructions originales) DManuel utilisateur (E Betriebsanleitung (Übersetzung der Originalanleitung) Gebruiksaanwijzing (Vertaling van de originele instructies)Instrukcje obsługi (Tłumaczenie oryginalnej instrukcji)Pу …
  • Scheppach

    Air Force 4

    (72 pages)
     www.scheppach.com /  [email protected] /  +(49)-08223-4002-99 /  +(49)-08223-4002-581 Air Force 4Art.Nr.5906103924AusgabeNr.5906103851Rev.Nr.16/04/2015Art.Nr.5906137901Ausgabe Nr.5906137850Rev.Nr.05/03/2020Nachdrucke, auch auszugsweise, bedürfen der Genehmigung. Technische Änderungen vorbehalten. Abbildungen beispielhaft!DEDruckluftkompres …
  • Metabo

    Compressor SR 4900 L

    (48 pages)
    115 172 3108/ 4605 - 1.0Betriebsanleitung. . . . . . . . . . . . . . . . . . . . 3Operating Instructions . . . . . . . . . . . . . . . . 7Instructions d'utilisation . . . . . . . . . . . . . . 11Handleiding . . . . . . . . . . . . . . . . . . . . . . . 15Betjeningsvejledning . . . . . . . . . . . . . . . . 19Bruksanvisning . . . . . . . . . . . . …
  • Campbell Hausfeld

    DC060500

    (22 pages)
    6 Gallon Quiet Compressor Operating Instructions and Parts Manual Model: DC060500 © 2016 Campbell Hausfeld A Marmon/Berkshire Hathaway Company IN641701AV 8/16 …
  • Beta

    1555/QS

    (84 pages)
    1555/QS ISTRUZIONI PER L’USOIINSTRUCTIONS FOR USEENMODE D’EMPLOIFGEBRAUCHSANWEISUNGDINSTRUCCIONESEGEBRUIKSAANWIJZINGNLHASZNÁLATI ÚTMUTATÓHUINSTRUÇÕES DE USOPBETJENINGSVEJLEDNINGDK/NOINSTRUKCJA OBSŁUGIPL …

Comments, Questions and Opinions: