Toshiba 1500 Plus Operation Manual

Toshiba 1500 Plus Manual Online:

4.3, 2658 votes
Toshiba 1500 Plus User Manual
Toshiba 1500 Plus User Guide
Toshiba 1500 Plus Online Manual

Text of Toshiba 1500 Plus User Guide:

  • Toshiba 1500 Plus, TOSHIBA CONTENTS SECTION PAGE Disclaimer ..................................................................................................i Contents .................................................................................................. ii-iii Introduction...............................................................................................iv General Safety Instructions ..................................................................... v Important Safety Instructions............................................................... vi-vii 1.0 Product Description ................................................................................1-

  • Toshiba 1500 Plus, TOSHIBA Fuse rating Model Amp rating Fuse model no. 600 VA 15.0A Bussmann MDL-8 800 VA 15.0A Bussmann MDL-8 1000 VA 15.0A Bussmann MDL-8 8.0 Preventive and Scheduled Maintenance/Parts Replacement 8.3 Fuse Rating Chart The following chart shows the recommended fuses for all UPS sizes. 8 - 2

  • Toshiba 1500 Plus, TOSHIBA 8.0 Preventive and Scheduled Maintenance/Parts Replacement 8.1 Preventive Maintenance Toshiba's 1500 and 1500 Plus Series of uninterruptible power systems have been designed to provide years of trouble-free operation requiring a minimum of preventive maintenance. The best preventive measure that the UPS user can take is to keep the area around the unit, particularly the air inlet vents, clean and free of moisture and dust accumulations. If the atmosphere of the installation site is very dusty, use a vacuum cleaner to periodically remove dust accumulations from the system. Schedule authorized service centers to perform internal parts

  • Toshiba 1500 Plus, TOSHIBA 4 - 1 4.1 Standard Series Specifications 4.0 Specifications MODEL NUMBER UE1E1E008-5M UE1E1E010-5M CAPACITY 800 VA (0.56 kW) 1000 VA (0.7 kW) Input Input voltage Single phase, 220 Vac, +10% to -30% (*) Input frequency 45 to 65 Hz Input capacity 800 VA 1000 VA Input power factor Approximate unity (0.95 to 1.0) Battery Battery rated voltage 60 Vdc Battery backup time when fully charged 8 min. at full load (**) 7 min. at full load (**) with 0.7 power factor at 77° F (25° C) 20 min. at half load (**) 18 min. at half load (**) Recharge time Maximum 24 hrs to 100% (90% recharge after 8 hrs) (***) Type of batteries

  • Toshiba 1500 Plus, TOSHIBA CONTENTS (Cont'd) SECTION PAGE 5.0 Operating the UPS (cont'd) .....................................................................5-1 5.3 Operation Monitoring ......................................................................5-3 5.3.1 Visual Indicator Functions......................................................5-3 5.3.2 Audible Alarm Functions ........................................................5-3 5.3.3 Visual and Audible Indicator Function Chart ..........................5-3 5.4 Front Panel Layout .

  • Toshiba 1500 Plus, TOSHIBA 6.0 UPS Control Interface 6.2 RS-232C Serial Communication Interface The available data from the UPS, via RS-232C communication, is shown below: Output voltage Output current Operating conditions Battery voltage Input frequency Output frequency Utility power OK Low battery voltage detected UPS operating status UPS in BYPASS mode (described as ‘yes’ or ‘no’) UPS in NORMAL mode Input and output frequency synchronized UPS ‘fault’ occurred DC bus overcurrent DC bus overvoltage DC bus undervoltage 'Fault’ details Input overcurrent (described as ‘occurred’ Overheat or ‘not occurred’) Overload being tim

  • Toshiba 1500 Plus, TOSHIBA 5 - 5 5.0 Operating the UPS (Cont'd) 5.6 Battery Recharging The graph below shows the typical voltage requirements for recharging the UPS unit's batteries. Model Vmax. Vmin. Charge 600 VA 68.2 48.0 0.4 (A) 800 VA 68.2 48.0 0.4 (A) 1000 VA 68.2 48.0 0.4 (A) Rated battery voltages Period 1 Period 2 Period 3 Time Current Voltage Vmax. Vmin. Battery charge voltage Fully charged Discharge shut-off point Charging current 0.4 amp (A) 0 0 The recharge process usually consists of three periods. During the first period, the current is maintained at approximately 0.4 amperes. In the secon

  • Toshiba 1500 Plus, TOSHIBA 2.0 Inspection/Storage/Disposal 2.1 Inspection of the new UPS equipment Upon receipt of the UPS, a careful inspection for shipping damage should be made. After Uncrating: 1) Check the unit for loose, broken, bent or otherwise damaged parts. If damage has occurred during shipment, keep all original crating and packing materials for return to shipping agent. Warranty will not apply to units which are damaged during shipment. 2) Check to see that the rated capacity and the model number specified on the nameplate conform to the order specifica

  • Toshiba 1500 Plus, TOSHIBA 5.0 Operating the UPS 5.1 Operation Modes 5.1.3 Circuit-bypass mode Power flow in circuit-bypass mode. If the UPS unit is severely overloaded or develops an internal fault, the power flow is automatically switched from the unit's main circuit to the bypass circuit mode. Power flow through the bypass is shown in the above illustrations. This change- over occurs automatically in approximately 4 milliseconds. The switching period is not long enough to cause interruptions to occur in most UPS equipment loads. The energy flow must be transferred manually from the UPS's bypass circuit back to the inverter circuit a

  • TOSHIBA The instructions contained in this manual are not intended to cover all of the details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matt

  • Toshiba 1500 Plus, TOSHIBA 5.0 Operating the UPS 5.3 Operation Monitoring 5.3.1 Visual Indicator Functions The following LED (light emitting diode) indicators are located on the front panel (see Section 9.2 "Panel Layout"). Refer to these lamps for visual information about the operating condition of the UPS (see Section 5.3.3 "Visual and Audible Indicator Function Chart"). 1) AC Input: This green LED lights when normal ac input power is being supplied to the UPS unit. 2) On Line: This green LED lights when the inverter output voltage is normal. 3) Fault: This red LED lights when an abnormal operating cond

  • Toshiba 1500 Plus, TOSHIBA 3 - 1 3.0 Precautions 3.1 Installation Precautions (General) 1) Install the unit in a well ventilated location; allow at least 10 cm (4 inches) on all sides for air ventilation and for maintenance. 2) Install the unit in a stable, level, and upright position which is free of vibration. 3) Install the unit where the ambient temperature is within the correct operating range (see Specifications Section 4.0). 4) Do not install the UPS in areas that are subject to high humidity. 5) Do not allow direct sunlight to shine on the unit. 6) D

  • Toshiba 1500 Plus, TOSHIBA IMPORTANT SAFETY INSTRUCTIONS Installation and servicing of batteries should be performed by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from the batteries. Proper maintenance to the battery system of this unit must be done by a qualified service technician, this is essential to the safety and reliability of your UPS system. Refer to service manual. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working with batteries: 1) Verify that the UPS is off and that the power cord is disconnected from the power source. 2)

  • TOSHIBA Model Capacity Manufacturer Type Quantity 600 VA Yuasa NPH5-12FR 5 800 VA 1000 VA Yuasa NPH5-12FR 5 viii © Copyright 1994 INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ Cette notice contient des instructions importantes concernant la sécurité. Une battery peut présenter un risque de choc électrique, de brûlure par transfert d' énergie. Pour le r

  • TOSHIBA Fault Display status Probable cause Corrective action DC Inverter fault overcurrent DC Chopper fault overvoltage Contact your Toshiba service representative. Input Chopper fault overcurrent UPS system Trouble with the control error PWB 7 - 2 7.0 Troubleshooting Procedures 7.2 Fatal Fault Mode Fatal faults may or may not cause the UPS to shutdown. Use "System Reset&q

  • Toshiba 1500 Plus, TOSHIBA 5 - 6 5.0 Operating the UPS 5.7 Battery Backup Time The UPS unit's batteries provide about 5-12 minutes of back-up time depending on the capacity of the UPS. These times are valid when a unit is operating under full load. When the units are operating at half load, the batteries can power the load equipment about 3 times longer. The exact length of these times will depend on the UPS model used, condition of the batteries, amount of load, temperature and other variables. See battery backup time in the standard specifications Sections 4.1 through 4.2. 5.8 Battery Low Voltage Toleranc

  • TOSHIBA 6 - 1 6.0 UPS Control Interface 6.1 DB25 Connector Pinout RS-232C serial communication and Dry Contacts are both standard features available through a DB25 female connector located on the back panel of the UPS (see Section 9.1). The RS-232C serial communication interface allows control of the UPS from a personal computer running special Toshiba software. The computer is connec

  • Toshiba 1500 Plus, TOSHIBA SAVE THESE INSTRUCTIONS- This manual contains important instructions that should be followed during the installation and maintenance of the UPS and it's batteries. Use for models UE1E1E006-5M, UE1E1E008-5M, UE1E1E010-5M. - The maximum ambient temperature in which this UPS unit should be operated or stored is 104 °F (40 °C). - The nominal battery voltage range is indicated in Section 5.6. - Servicing of the batteries should only be performed by a qualified Toshiba Representative who is knowledgeable of b

  • Toshiba 1500 Plus, TOSHIBA UNINTERRUPTIBLE POWER SYSTEM SINGLE PHASE - .6/.8/1.0 kVA 220V August, 1998 Part # 48449-000 MANUFACTURED IN THE U.S.A. OPERATION MANUAL 1500 1500 1500 1500 1500 and 1500 PLUS SERIES

More Instructions:

DOWNLOAD

Related Products and Documents (Power Supply):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Audiovox APS-55TWT Installation instructions manual audiovox/aps-55twt-XY3.pdf 31 May 2023 16 0.19 Mb
2 Blaupunkt CANBERRA 7 647 523 310 Operating and installation instructions blaupunkt/canberra-7-647-523-310-EA2.pdf 09 Dec 2023 45 3.76 Mb
3 WiebeTech TC-PCIE-2XR Operation & user’s manual wiebetech/tc-pcie-2xr-931.pdf 20 Jul 2023 11 1.47 Mb
4 Fisher-Price K7117 Operation & user’s manual fisher-price/k7117-M19.pdf 03 Aug 2022 5 0.63 Mb
5 Samsung TL9 Quick start manual samsung/tl9-J7S.pdf 26 Apr 2023 19 5.33 Mb
6 Cabletron Systems 9A100 Operation & user’s manual cabletron-systems/9a100-6VF.pdf 26 Oct 2023 114 0.74 Mb

Similar Resources:

  • Coolmax

    CA-300

    (4 pages)
    Model: CA-300 1. Function Description This power supply is designed for personal computer. There are six DC outputs: +5V, -5V, +12V, -12V, +3.3V+5VSB , and it provides power to all computer systems and peripherals with maximum protection. Here are some of the key features: S-ATA ready All kinds of protection circuits (OVP/OPP/SCP) Fully …
  • Puls

    QS40.241

    (2 pages)
    Headquarters: PULS GmbH, Elektrastr. 6, 81925 Munich, Germany, www.pulspower.com Germany +49 89 9278 0 China +86 512 62881820 France +33 478 668 941 North America +1 630 587 9780 Austria +43 2764 3213 Singapore +65 6684 2310 Switzerland +41 56 450 18 10 United Kingdom +44 1525 841001 The information in this document is believed to be accurate and …
  • Zetex

    ZXLD1615/1601

    (5 pages)
    1www.zetex.comKnow–howCompany proprietary – Sales network use onlyNew product information from Zetex July 2004ZXLD1615/1601 boost converter forLCD-OLED bias and DC-DC supplyFeatures Benefits• Internal 30V NMOS switch• True analog output voltage control• High efficiency: 80% typical• 2.5V to 5.5V supply range• Low quiescent current• TSOP23-5 …
  • Tripp Lite

    APS Series

    (52 pages)
    1Owner’s ManualAPS-Series DC-to-AC Inverter/ChargersModels: APS2012, APS2424, APS3636VR, APSINT2012, APSINT2424, APSINT3636VRIntroduction 2 Safety 2Feature Identification 3Operation 4Configuration 5Battery Selection 8Mounting 9Battery Connection 10AC Input/Output Connection 11Service/Maintenance 11Troubleshooting 12Warranty/Product Registration 13Es …
  • CarNetix

    PSU-PC19 DC

    (28 pages)
    CarNetix PSU-PC19 V2.0 Installation Manual CarNetix PSU-PC19 DC-DC Power Supply Installation and Operation of the PSU-PC19 with the Xenarc SC8 Version 1.0 (applies to Version 2.0+ hardware) February 1, 2006 - 1 - …
  • Horizont

    Hotshock A300

    (11 pages)
    Instruction manualOriginalbetriebsanweisungNotice d‘utilisationhotshock A300Type 10613 ORIGINALBETRIEBSANLEITUNG Elektrozaungerät INSTRUCTION MANUAL Electric Fencer NOTICE D‘UTILISATION Électricateur de clôture MANUAL DE INSTRUÇÕES Cerca Eléctrica ISTRUZIONI PER L’USO Apparecchio per recinti elettrici INSTRUKCJA EKSPLOATACJI Urzą …

Comments, Questions and Opinions: