Manualios.com

Powercom 1000VA Operation & User’s Manual

Powercom 1000VA Manual Online:

3.65, 2957 votes
Powercom 1000VA User Manual
Powercom 1000VA User Guide
Powercom 1000VA Online Manual

Text of Powercom 1000VA User Guide:

  • Important safety instructions Thank you for selecting this uninterruptible power system (UPS). It provides you with better protection for connected equipment. Please read this manual! This manual provides safety, installation and operating instructions that will help you derive the fullest performance and service life that the UPS has to offer. Please save this manual

  • Powercom 1000VA, Table of contents 1 Introduction… … … … … … … … … … … … … 1 2 Safety… … … … … … … … … … … … … … … ..2 3 Presentation… … … … … … … … … … … … 3 4 Front Panel… … … … … … … … … … … … ..3 5 Rear Panel … … … … … … … … … … … … … 4 6 Installation… … … … … … … … … … … … … 5 7 Operation… … … … … … … … … … … … … .7 8 Alarms… … … … … … … … … … … … … … ..8 9 Software Options… … … … … … … … … … 9 10 Computer Interface Port………………10 11 Battery repl

  • Powercom 1000VA, 1. INTRODUCTION The product is line interactive UPS with the newest technology and powerful function. The LINE INTERACTIVE UPS is with AVR function allows input voltage range from 75% to 125%, including on line voltage boost-up & buck down. An ideal protection equipment for critical connected loads. It is based on microprocessor controls, with utility power connected, the charging is ongoing, no need to switch ON the UPS and at back-up mode, UPS can be automatically turned OFF if none of the connected loads is operating to save the bat

  • Powercom 1000VA, 2. Safety CAUTION ! • To reduce the risk of electric shock, disconnect the UPS from the mains supply before installing a computer interface signal cable. Reconnect the power cord only after signaling interconnections have been made. • The internal energy source(the battery) cannot be de-energized by the user. The output may be energized when the unit is not connected to a mains supply. • The right way to de-energize the UPS properly in an emergency is to move the I/O switch to the OFF position and disconnect the power cord from the mains supply. • The socket-outlet sha

  • Powercom 1000VA, 3. Presentation FRONT PANEL 3.1 "REPLACE BATTERY" indicator (RED LED) The LED illuminates when the UPS's battery is no longer useful and must be replaced. 3.2 "BUCK AVR (VOLTAGE REDUCTION)" indicator (YELLOW LED) The LED illuminates when the UPS is correcting a high utility voltage condition. The loads receive normal power. 3.3 "BACK UP" indicator (YELLOW LED) The LED illuminates when the UPS is supplying battery power to the loads. 3.4 "BOOST AVR (VOLTAGE BOOST)" indicator (YELLOW LED) The LED illuminates when the UPS is correcting a low utility voltage condition. The loads receive no

  • Powercom 1000VA, REAR PANEL 3.10 MAIN SWITCH 3.11 REMOTE PORT (COMPUTER INTERFACE) Provide both RS-232 and relay signal to support NOVELL, UNIX, DOS, WINDOWS and other operating systems. 3.12 TEL./MODEM SURGE PROTECTION Surge protection for telephone and modem line to have the complete safety connection for INTERNET service. 3.13 SITE WIRING FAULT INDICATORS (RED LED) It comes on when the UPS is connected to an improperly wired AC power outlet. Note: This device is available on 110 Vac model only. 3.14 SURGE PROTECTION OUTLET The full time surge protection outlet provides protection from surges such as those created by lighting or connected equipme

  • Powercom 1000VA, 4. Installation 4.0 Inspection Inspect the UPS upon receipt. The packaging is recyclable; save it for reuse or dispose of it properly. 4.1 Placement Install the UPS in a protected area with adequate air flow and free of excessive dust. Do not operate the UPS where the temperature and humidity is outside the specified limits. 4.2 Connect Computer Interface (optional) UPSMON series software (or other power management software) and an interface kits can be used with this UPS. Use only kits supplied or approved by the manufacturer. If used, connect the interface cable to the 9 pin computer interface port on the back panel of the UPS. Note: Computer interface conne

  • Note: This connection is optional. It is not necessary to use this UPS. Caution: The telephone line current limiting feature could be rendered inoperable if improperly installed. Make sure that the telephone line from the wall is plugged into the connector marked “IN”, and the device to be protected (telephone, modem, etc.) is plugged into the connector marked “OUT”. Caution: This s

  • Powercom 1000VA, 5. Operation 5.1 Switch on With the UPS plugged in, turn on MAIN SWITCH (on rear panel) and press ON/OFF/TEST/SILENCE button (on front panel) less than 2 seconds to switch the UPS on. The UPS will perform self-testing each time when it is switched on. Note: When switched off the UPS maintains the battery charge and will respond to commands received through the computer interface port. 5.2 Switch off By pressing and holding ON/OFF/TEST/SILENCE button until the "LINE NORMAL" or "BACK UP" LE

  • Powercom 1000VA, 6. Alarm 6.1 "BACK UP" (slow alarm) When in BACK UP mode, the YELLOW LED illuminates and the UPS sounds an audible alarm. The alarm stops when the UPS returns to LINE NORMAL operation. Press the ON/OFF/TEST/SILENCE button during on-battery alarms to stop the beeping. 6.2 "LOW BATTERY" (rapid alarm) In BACK UP mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shuts down from battery exhaustion or returns to LINE NORMAL operation. 6.3 "OVERLOAD" (continuous alarm) When the UPS is overloaded (the connected loads exceed the maximum rated capacity) the UPS em

  • Powercom 1000VA, 7. Software options 7.1 Power Monitoring Software The UPSMON series software (or other power monitoring software) is applied standard RS-232 interface to perform monitoring functions, and then provides an orderly shutdown of a computer in the event of power failure. Moreover, UPSMON displays all the diagnostic symptoms on monitor, such as Voltage, Frequency, Battery level and so on.. The software is available for DOS, Windows 3.1x, Windows 95, Windows NT V3.5 or later, Novell Netware and others. Call your dealer for more information on computer OS compatible solutions. 7.2 Interface Kits A series of interface kits is available for operation systems that provide

  • Powercom 1000VA, 8. Computer Interface Port The computer interface port has the following characteristics: 11 D-SUB 9 Pin Female Connector for white cable Contacts Normally Open Pin Number Signal High Min. 1 Second 5 2 4 7 6 1 8 9 3 Low Battery Mains Failure Common UPS Shut Down or RS232 RD Pin 3 RS232 TX Pin 2 RS232 RTS Pin 7 RS232 DTR Pin 4 No Connection D-SUB 9 Pin Female Connector for purpure cable Contacts Normally Open Pin Number Signal High Min. 1 Second 5 2 4 7 6 9 8 3 1 Low Battery Mains Failure Common UPS Shut Down or RS232 RD Pin 3 RS232 TX Pin 2 RS232 RTS P

  • Powercom 1000VA, 9. Battery Replacement Your battery should run any where from 3-5 years before eve needing to be replaced. Please follow the instructions below for easy battery replacement. Note: When replace battery, disconnect the utility power then open the case and take notice of the battery's polarity while install the new battery to avoid short. 1) Unplug unit from AC power source and disconnect all connected equipment. 2) Disconnect AC power cord from unit.. 3) Turn unit upside down and using a phillips screw driver, unscrew the 4 screws holding the top of the unit to the bottom. Put screws in a safe place for reconnection. 4) Holding the top together firmly

  • Powercom 1000VA, 10. Troubleshooting PROBLEM POSSIBLE CAUSE ACTION TO TAKE On/off/test/silence button not pushed or push too short Press the on/off/test/silence button more than 1 second Battery voltage less than 10V Recharge the ups at least 4 hours PCB failure Replace the PCB, call for service UPS not on LED not light Load less than 20W at battery mode Normal condition Power cord lose Replug the power cord AC FUSE burn out Replace the AC fuse Line voltage too high, too low or black out Normal condition UPS always at battery mode PCB failure Replace PCB, call for service battery not fully charged Recharge the UPS at least 4 hours Back up time too short PCB failure Replac

  • 12. Specifications MODEL KIN 800AP KIN 1000AP KIN 1200AP KIN 1500AP KIN 2200AP Capacity 800VA 1000VA 1200VA 1500VA 2200VA Voltage +/-25% at line input INPUT Frequency 50 or 60Hz +/-10% (auto sensing) Voltage (on battery) Simulated sine wave at 100V/110/115V/120V/220V/230V/240V +/-5% Frequency (on battery) 50 or 60Hz +/-0.5% Voltage Regulation AVR AVR automatically incre

More Instructions:

DOWNLOAD

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LEGO 76025 SUPER HEROES Assembly manual lego/76025-super-heroes-988.pdf 18 Mar 2023 80
2 Bryant 398AAZ Manual  bryant/398aaz-T5F.pdf 26 Jan 2024 4 0.59 Mb
3 Intek H-520 PLUS Owner's manual intek/h-520-plus-MRC.pdf 01 Feb 2023 40
4 Biostar GF8100 M2G PLUS - BIOS Manual  biostar/gf8100-m2g-plus-bios-JJ6.pdf 12 Mar 2023 38 0.21 Mb
5 Blackberry BOLD 9000 - SMARTPHONE FOR JAPAN - SAFETY AND Getting started manual blackberry/bold-9000-smartphone-for-japan-safety-and-4R2.pdf 22 Oct 2022 46 3.64 Mb
6 AIPTEK SecuCam AV100 Operation & user’s manual aiptek/secucam-av100-ACV.pdf 16 Sep 2023 25 4.69 Mb

Similar Resources:

  • Omega

    1000

    (6 pages)
    OmegaProducts, Inc.Harrisburg,PA 17111-4523, U.S.A.Phone: (717) 561-1105Fax: (717) 561-1298E-mail: [email protected] AND COMMERCIAL USEINSTRUCTION MANUAL FOR THE OMEGA JUICER 1000 AND 500Omega. . .A Legendary Name In Fresh JuiceE x t r a c t i o n . …
  • PC Energy

    PCE600-UNI

    (2 pages)
    DE Allgemeine und Sicherheitshinweise: Bitte lesen Sie diese Anleitung vor Inbetriebnahme. Das Gerät sollte nur von qualifizierten Fachpersonal gemäß geltender Vorschriften installiert werden. Der Hersteller haftet nicht für Schäden verursacht durch unsachgemäße Installation und Bedienung, selbständige Durchführung von Reparaturen oder Ände …
  • Tripp Lite

    SmartPro 450 RT

    (8 pages)
    1Copyright ©2000 Tripp Lite. All rights reserved. SmartPro® is a registered trademark of Tripp Lite.1111 W. 35th StreetChicago, IL 60609 USACustomer Support: (773) 869-1234www.tripplite.comInstallation: p. 3 - 4Basic Operation: p. 5 - 7Storage & Service: p. 8Specifications: p. 8Safety: p. 2Owner's ManualSmartPro® 450 RTIntelligent Network UPS Sy …
  • Siemens

    SITOP UPS1600

    (264 pages)
    SITOP UPS1600 / BAT1600 / UPS1100 SITOP power supplies SITOP UPS1600 / BAT1600 / UPS1100 Equipment Manual SITOP UPS1600 10 A 6EP4134-3AB00-0AY0 6EP4134-3AB00-1AY0 6EP4134-3AB00-2AY0 SITOP UPS1600 20 A 6EP4136-3AB00-0AY0 6EP4136-3AB00-1AY0 6EP4136-3AB00-2AY0 SITOP UPS1600 40 A 6EP4137-3AB00-0AY0 6EP4137-3AB00-1AY0 6EP4137-3AB00-2AY0 SI …
  • mini-box

    Open-UPS

    (11 pages)
    OPENUPS 6-30V Intelligent Uninterruptible Power Supply Installation Guide Version 1.0f P/N OPENUPS-06 Before you start… Please take a moment and read this manual before you install the OPENUPS. Often times, rushing into installing the unit can result in serious damage to your OPENUPS board, computer. Always double check the polarity of your wi …
  • Maruson

    Power Pro 650VA

    (2 pages)
    USER MANUAL Let’s Connect @marusontechnology Power Pro Series 650VA / 850VA / 1200VA / 1650VA / 2200VA IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety instructions that must be followed to avoid fire, property damage, personal injury, or death. The warnings, precautions, and instructions mentioned in this manual cannot cover all …

Comments, Questions and Opinions: