  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual cc Transducer Coefficient Description Datum Type www.PressureSystems.com 3 - 64 24-28 Temperature 6, Pressures 1-5 voltages FLOAT 29-2D reserved for future use (temperature 7) FLOAT 2E Temperature 1 Temperature Output voltage at 0 psi FLOAT 2F Temperature 2 Temperature Output voltage at 0 psi FLOAT 30 Temperature 3 Temperature Output voltage at 0 psi FLOAT 31 Temperature 4 Temperature Output voltage at 0 psi FLOAT 32 Temperature 5 Temperature Output voltage at 0 psi FLOAT 33 Temperature 6 Temperature Output voltage at 0 psi FLOAT 34 (reserved) Temperature 7 Temperature Output voltage at 0

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 4 - 14 Figure 4.5 9021 and 9022 Voltage Input Connections 4.5.1 Setup The calibration and verification function will require the application of precise voltage sources to the pressure voltage input pins of the 9021 and 9022 transducer interface connectors. Application of this voltage may be made through any one of the twelve 9021 and 9022 interface connectors although more complete verifications of performance will require applying these voltages to all twelve input connectors. Figure 4.5

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 3 - 67 The coefficients of internal DH200 transducers used in the Model 9016 are selected with array indexes aa=01 through 10 (hex). Coefficients of external 9400 transducers used by Models 9021 and 9022 (digitally compensated) are selected with array indexes aa=01 through 0C (hex). All valid coefficient indexes (for each of these arrays) are listed in the following table: cc Transducer Coefficient Description Datum Type 00 Re-zero Cal Adjustment (offset) term (Note 1) FLOAT 01 Span Cal Adjustment (gain) term (Note 2) FLOAT 02 Dynamic EU Conversion coefficient

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com - vii - Table of Contents (Cont.) 3.1.2 Commands ............................................... 3-2 3.1.2.1 General Command Format ............................. 3-2 3.1.2.2 Command Field ..................................... 3-3 3.1.2.3 Position Field ....................................... 3-3 3.1.2.4 Datum Fields ....................................... 3-4 3.1.2.5 Format Field ........................................ 3-4 3.1.3 Responses ................................................ 3-4 3.1.3.1 Interpreting Off

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 4 - 12 Ready the module for multi-point calibration by executing the Configure & Start (‘00’) sub-command of ‘C’. This establishes all the channels to be affected, and determines the total number of calibration points that will be supplied (3 in this example) in later steps. It also starts module averaging for calibration (64 samples in this example). The linear fit (1) is required. C 00 FFFF 3 1 64 (9016) or C 00 0FFF 3 1 64 (9021/9022) Apply 1st calibration pressure to the module’s CAL or RUN inputs. The zero (0.0) point is assumed in this case. After applying zero

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 6 - 1 Chapter 6 Troubleshooting Guide 6.1 Ethernet Module Troubleshooting 6.1.1 Checking Module Power-Up Sequence (1) Proper power to the module should first be verified. If possible, verify that the output of the module power supply is set within the range of 18-36 VDC. This should be nominally set for 24 VDC. Ensure the power supply setting is high enough to compensate for cable voltage drops if long interface cable lengths are used. (2) Turn module power switch ON and verify the following top panel LED status following

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 1 - 3 1.2 Description of Instruments NetScanner ™ System family of Intelligent Pressure Scanner modules are flexible pressure measuring devices intended for use in test and production environments. Models are available with 12 (Model 9021/9022), or 16 (Model 9016) channels, each with individual pneumatic or all- media transducers per channel. The most distinctive features are highlighted below: ! Pre-calibrated Transducer — a memory chip containing full calibration data is embedded within each inter

  • Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com - v - ATTN: PSI REPAIR DEPARTMENT (7-digit RMA number) Pressure Systems, Inc. 34 Research Drive Hampton, Virginia 23666 PSI will return warranty items prepaid via UPS GROUND. If the customer desires another method of return shipment, PSI will prepay and add the ship

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 5 - 13 (5) Attach the wiring harness to the solenoid and connector P6 of the PC-280 CPU board. (6) Reassemble the module. (7) Test your scanner to ensure proper operation. 5.1.6 Replacement of O-Rings Pressure Systems’ calibration valves include static and dynamic O-ring seals. When used properly, the rated durability of the dynamic O-rings is in excess of 1,000,000 shifts of the calibration valv

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 5 - 7 5.1.3.2 PC-242 Amplifier/Multiplexer Board (9021 ONLY) The following procedures should be used for replacement of the PC-242 Amplifier/Multiplexer Board. The PC-242 is attached directly to the top plate of the 9021. Use the tools and follow the general warnings already described at the start of Section 5.1. (1) Disassemble the module as described in Section 5.1.2. Carefully remove the wiring harness from connector P1 of the PC-242 board. (2) Remove the screws fastening the PC-242 board to the top panel and remove the board assembly. For the

  • Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com D - 1 Appendix D Mounting Dimensions 9016 Mounting Dimensions ................................................... D-2 9021 Mounting Dimensions ................................................... D-3 9022 Mounting Dimensions .................................

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com C - 1 Appendix C Cable Diagrams Description Applicable Models Page Ethernet Interface Cable - unterminated host Ethernet Interface Cable 9016, 9021, and 9022 9016, 9021, and 9022 C-2 C-3 9400 Series/9021 (D-Shell) Cable 9021 C-4 9400 Series/9022 (Circular Connector) Cable 9022 C-5 9021 to Series 27 Interface Cable 9021 C-6 9022 to Series 27 Interface Cable 9022 C-7 Calibration Cable 9022 C-8 3 rd Party Sensor Interface Cable 9022 C-9

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com - x - List of Figures Figure 1.1 NetScanner System Pneumatic Intelligent Pressure Scanners ........ 1-2 Figure 2.1 9016, 9021, 9022 Power Pin Assignments ...................... 2-2 Figure 2.3 Ethernet Host Port Connector Pins ............................ 2-3 Figure 2.3 Ethernet Network Topology .................................. 2-5 Figure 2.4 9021 Transducer Wiring ................................... 2-10 Figure 2.4a 9022 Transducer Wiring ..............................

  • Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com - i - ©This User’s Manual is a copyright product of Pressure Systems, Inc. , 2007. Permission is hereby granted to make copies and distribute verbatim copies of this manual, provided the copyright notice and this permission notice are preserved on all copies.

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 3 - 11 3.1.4.4 Delivery of Acquired Data To Host Several commands apply to host delivery of acquired data, either on demand or autonomously. The Read High Precision Data (‘r’) command may be used to obtain high precision data (selected channels in various formats). The modules also provide several high speed, high resolution output commands. The Read High-Speed Data (‘b’) command is used to read “pure binary” engineering unit pressure (all channels in the lowest overhead format). Use the ‘r’ and

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 3 - 62 READ INTERNAL COEFFICIENTS (Command ‘u’) Purpose: Returns one (or more contiguous) requested internal coefficient(s) in a specified internal coefficient array, and in the specified response data format. Command “ufaacc[-cc]” ‘u’ is the command letter. ‘f’ is the format field. ‘aa’ is the array index field. ‘cc[-cc]’ is coefficient index [or contiguous range]. Response

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 3 - 32 NOTE: When using hardware trigger inputs to synchronize data stream outputs, the frequency of the trigger source should be no more than 200Hz even if the requested output is 100Hz or less. NOTE: Avoid confusing this Configure/Control Autonomous Host Streams command ‘c’ (lower case c) with the Configure/Control Multi-Point Calibration command ‘C’ (upper case C). Like ‘C’, but unlike most other module commands, all sub-commands of this command require a space between the command id (‘c’) and the first parameter (ii). Des

  • Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com B - 1 Appendix B NetScanner ™ System Response Error Codes: CODE MEANING 00 (Unused) 01 Undefined Command Received 02 Unused (by TCP/IP) 03 Input Buffer Overrun 04 Invalid ASCII Character Received 05 Data Field Error 06 Unused (by TCP/IP) 07 Specified Limits Invalid 08 NetScanner ™ Sy

  • Pressure Systems 9022, Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual www.PressureSystems.com 3 - 78 CHANGE MODULE’S IP ADDRESS RESOLUTION METHOD & RE-BOOT (UDP/IP Command ‘psirarp’) Purpose: To change (toggle) the current IP address resolution state (ipaarpst) of a specified module, and then unconditionally “re-boot” it. Command “psirarp ethadr” where ethadr is the Ethernet address of the specified module in the following special hex-digit format ‘xx-xx-xx-xx-xx-xx’ Response none (module re-boots) Description: When a module receives thi

Related Products and Documents (Scanner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Axis Q6035 PTZ Operation & user’s manual axis/q6035-ptz-A57.pdf 01 Jan 2023 62 2.62 Mb
2 NordicTrack NTEL11990 Operation & user’s manual nordictrack/ntel11990-VD9.pdf 14 Apr 2023 24
3 Traynor Custom Valve 20 Owner's manual traynor/custom-valve-20-3JN.pdf 31 Jan 2023 14 1.56 Mb
4 Blitz Audio BZC-1802MP Owner's manual blitz-audio/bzc-1802mp-LF7.pdf 06 Oct 2023 15 0.46 Mb
5 AVIRA SMALL BUSINESS SUITE Manual  avira/small-business-suite-O9C.pdf 20 Apr 2023 16 0.55 Mb
6 Honeywell RPW314 Instruction leaflet honeywell/rpw314-692.pdf 04 Jan 2023 1 0.25 Mb

Similar Resources:

  • Conrad

    Magicscan MS802

    (4 pages)
    Bestimmungsgemäße VerwendungDas Produkt ist zum Anschluss an einen USB-Port vorgesehen und dient dort als kleiner Hand-scanner z.B. für Visitenkarten. Zum Betrieb ist ein USB-Port erforderlich, der einen Strom von 500 mA liefern kann.Dieses Produkt erfüllt die gesetzlichen, nationalen und europäischen Anforderungen. Alle ent-haltenen Firmennamen und Pro …
  • Canon

    CanoScan 9900F

    (19 pages)
    1Quick Start GuideQuick Start GuideSetup and ScanningTry the Additional FeaturesCheck the Package ContentsInstall the SoftwareWindowsMacintoshUnlock the Scanning UnitConnect the ScannerTry Scanningp.2p.3p.4p.5p.6p.7Using the Scanner Buttonsp.10Scanning Film p.11Be sure to install the software programs before connecting the scanner to the computer!USB Interfa …
  • CSSN

    ScanShell 800N

    (1 pages)
    (1) © 2005 All rights reserved to CSSN card scanning solutions ScanShell 800N A mobile A6, sheet-fed, Twain-compatible color scanning device. The scanshell 800N connects directly to any standard USB port, no external power is required. It is the ideal scanning solution for photos, business cards, bank checks, ID cards, driving licenses, and lottery tic …
  • Canon

    CanoScan FB 1200S

    (112 pages)
    Canon Film Adapter UnitSoftwareFilmGet FAUUser’s GuideQuick StartFor those who prefer to jump rightinto scanningSteps 1-3For those who prefer a methodicalapproachOther FunctionsFor those who are detail orientedFor Windows & Macintosh …
  • Epson

    1250 - Perfection Photo Flatbed Scanner

    (4 pages)
    EPSON Perfection 1250/1250 PHOTO7/01 EPSON Perfection 1250/1250 PHOTO - 1Scanner PartsThe EPSON Perfection 1250 PHOTO includes a transparency unit, a 35 mm film holder, and a 35 mm slide holder:Scanner SpecificationsBasic SpecificationsScanner type Flatbed, colorPhotoelectric Color CCD line sensordeviceEffective pixels 10,200 × 14,040 pixels at 1200 dpi, 10 …
  • Radio Shack

    PRO-404

    (21 pages)
    User’s Guide 20-404/PRO-404Thank you for purchasing your Handheld Radio Scanner from RadioShack. Please read this user’s guide before installing, setting up, and using your new scannerHandheld Radio Scannerwww.radioshack.comPackage ContentsScanner AntennaBelt Clip User’s GuideQuick Start GuideAlkaline Battery Holder Rechargeable Battery Holder …

Comments, Questions and Opinions: