Manualios.com

Python Responder LC Model 991 Installation Manual

Python Responder LC Model 991 Manual Online:

3.3, 2432 votes
Python Responder LC Model 991 User Manual
Python Responder LC Model 991 User Guide
Python Responder LC Model 991 Online Manual

Text of Python Responder LC Model 991 User Guide:

  • Python Responder LC Model 991, 31 © 2008 Directed Electronics. All rights reserved. D2D Jumper settings The security system has the ability to work with a compatible module through the D2D lines. There are two settings: one for using an internal docking module, (p/n XK 400N) or an external docking XK module. Jumpers Jumpers Jumper settings when using an onboard D-2-D module Jumper settings when using an external D-2-D module Setting the light flash polarity Light flash (+) / (-) polarity The internal fuse is used to determine the light flash output. In

  • Python Responder LC Model 991, 43 © 2008 Directed Electronics. All rights reserved.  Menu 3 - Remote start Menu Item Feature Opt. 1 Opt. 2 Opt. 3 Opt.4 Opt. 5+ 1 Transmission Mode Manual Automatic 2 Engine Checking Mode Virtual Tach Voltage Off Tachom- eter 3 Cranking Time 0.6 sec. 0.8 sec. 1.0 sec. 1.2 sec. 1.4 (5)/1.6(6)/ 1.8 (7) 2.0(8)4.0(9) 4 Remote Start Runtime 12 min. 24 min. 60 min. 5 Activation Pulse Count 1 2 6 Turbo Mode No Turbo Mode On-1 min. On-3 min. On-5 min. 7 Timer Mode Runtime 12 min. 3 min. 6 min. 9 min. 8 Flex Relay Function Ignition

  • Python Responder LC Model 991, 6 © 2008 Directed Electronics. All rights reserved. After the remote start module has been installed, test the remote start module in accordance with the Safety Check outlined in this installation guide. If the vehicle starts when performing the Neutral Safety Shutdown Circuit test, the remote start unit has not been properly installed. The remote start module must be removed or properly reinstalled so that the vehicle does not start in gear. All installations must be performed by an authorized Directed Electronics dealer. OPERATION OF THE REMOTE START MODULE IF THE VEHICLE STARTS IN GEAR IS CONTRAR

  • Python Responder LC Model 991, 40 © 2008 Directed Electronics. All rights reserved. Note: Some features have more than two possible settings. Pressing or toggles through the two-chirp and higher settings. Once a feature is programmed: Other features can be programmed within the same menus Another menu can be selecteds The learn routine can be exited if programming is completes To access another feature in the same menu: Press and release the Valet/Program switch the number of times necessary 1. to advance from the feature you just programmed to the next one you

  • Python Responder LC Model 991, 14 © 2008 Directed Electronics. All rights reserved. Wire connection guides  Primary harness (H1) H1/1 RED/WHITE (-) 200mA TRUNK RELEASE OUTPUT When the system receives the code controlling trunk release output for longer than 1.5 seconds, the red/white wire supplies an output as long as the transmis- sion continues. This is typically used to operate a trunk/hatch release or other relay-driven function. Warning! Never use this wire to drive anything but a relay or a low-current input! The transistorized out- put can only supply 200mA of current. Connecting directly to a solenoid, motor, or other high-c

  • Python Responder LC Model 991, Bitwriters with a date code of 6a or older require an IC upgrade (p/n 998M). Some bitwriters with a date code of 6B do not require the IC upgrade, refer to tech tip # 1112 for more infor- mation. Bitwriter 2 compatible. Bitwriter®, Code Hopping™, Doubleguard®, ESP™, FailSafe®, Ghost Switch™, Learn Routine™, Nite-Lite®, Nuisance Prevention® Circuitry, Reveng- er®, Silent Mode™, Soft Chirp®, Stinger®, Valet®, Vehicle Recovery System®, VRS®, and Warn Away® are all Trademarks or Registered Trademarks of Di- rected Electronics. The Bitwriter ® (p/n 998U) requires

  • Python Responder LC Model 991, 48 © 2008 Directed Electronics. All rights reserved. tional dome light supervision feature must be installed as described in the Wire Connection Guide. Ignition controlled dome light Off (2). 2-6 FAD w/trunk release On (1): FAD w/trunk release OFF (2). In the default setting the factory alarm disarm output disarms the factory alarm system any time the button controlling the trunk release output is pressed. 2-7 Factory Alarm Disarm/With Unlock (1), Before Unlock (2), Remote Start Only (3): In the default setting the factory alarm disarm output

  • Python Responder LC Model 991, 61 © 2008 Directed Electronics. All rights reserved. The vehicle starts, but immediately dies.s Does the vehicle have an immobilizer? The vehicle’s immobilizer cuts the 1. fuel and/or spark during unauthorized starting attempts. Is the remote start programmed for virtual tach or voltage sense? If so, the 2. crank time may not be set high enough. Voltage sense does not work on some vehicles. Check diagnostics. Sometimes a shutdown becomes active during crank-3. ing or just after cranking. The vehicle starts, but the starter keeps running.s Is the system programmed for engine checking off or virtual tach voltage 1. sense? When

  • 47 © 2008 Directed Electronics. All rights reserved.  Menu 2 - Convenience 2-1 One time bypass Off (1): One time bypass ON. When programmed On (2) the unit does not passively arm/lock for one cycle when turning the ignition On and Off within 3 seconds. When going through this procedure the siren chirps once indicating that One Time Bypass has been activated. 2-2 Nuisance

  • Python Responder LC Model 991, 20 © 2008 Directed Electronics. All rights reserved. Warning! Never use this wire to drive anything but a relay or a low-current input! This transistorized out- put can only supply 200 mA. Connecting directly to a solenoid, motor, or other high-current device will cause the module to fail. H2/5 WHITE/BLACK (-) 200mA AUX 3 OUTPUT This wire provides 200 mA programmable output whenever the transmitter button(s) controlling Aux 3 is pressed. This output can be programmed to provide the following types of outputs Validity: Output that sends a sign

  • Python Responder LC Model 991, 51 © 2008 Directed Electronics. All rights reserved. “times out” when the remote start activates in timer mode. The system may be shut down using a shutdown at any time. Using the Bitwriter®, the run time can be programmed for any duration from 1-16 minutes. 3-8 Flex Relay Function: Ignition 2 (1) In the factory setting, the flex relay func- tions the same as the pink ignition 1 wire, in accessory (2) setting the flex relay functions the same as the Orange accessory 1 wire, in starter (3) setting the flex relay functions the same as the purple starter 1 wire. 3-9 Diesel Timer—Wait-To-Start Input (1) - 15 (2), 30 (3), or 45 (4) seconds. Default is th

  • Python Responder LC Model 991, Contents Warning! safety first ..........................................................................................5 What is included ...............................................................................................7 Installation points to remember ............................................................................7 Virtual Tach ..............................................................................................7 The control center .....................................................................................8 Valet® program switch ..............................................................................8 Status LED .........

  • Python Responder LC Model 991, 41 © 2008 Directed Electronics. All rights reserved. Feature menus The default settings are indicated in bold type.  Menu 1 - Security Menu Item Feature Opt. 1 Opt. 2 Opt. 3 Opt.4 Opt. 5+ 1 System Arming Mode Active Passive Arm w/o lock Passive Arm w/ lock Auto re-arm w/o lock Auto re-arm w/ lock 2 Panic Mode On Ign Off only Off 3 Confirmation Chirps On w/Warn chirps On On w/Warn chirps Off Off w/ Warn chirps On Off w/ warn chirps Off 4 Siren duration 30 sec. 60 sec. 5 Ign-controlled locks No Ign

  • Python Responder LC Model 991, 57 © 2008 Directed Electronics. All rights reserved. 7 flashes Timer mode/Turbo mode/Manual mode error * 8 flashes Neutral safety shutdown 9 flashes Low battery (voltage mode) 10 flashes Alarm triggered ** 11 flashes Wait-to-start input timed out * Timer mode error: Ignition is on or shutdown input is active when activating timer mode. Turbo mode error: Turbo mode is programmed off, engine is not on or shutdown input is active. Manual mode error: MTS mode not enabled. ** Alarm was triggered during remote start sequence. Remote starting diagnostics When the remote start function is activated and the 2-way remote emits an err

  • Python Responder LC Model 991, 8 © 2008 Directed Electronics. All rights reserved. D2D The system has the ability to interface with an XK module through the D2D port. The advantage to using a D2D interface is that there is less wiring involved in the installation. Check the XK module installation guide to determine which wires are not needed, and which options are available.  The control center The control center position should be discussed with the vehicle’s owner prior to installation. The LED and Valet switch is housed on the control center, so you may want to check that the customer is satisfied with the location. LED

  • 16 © 2008 Directed Electronics. All rights reserved. H1/6 VIOLET (+) DOOR TRIGGER INPUT This wire is used in vehicles that have a positive (+) switched dome light circuit. Connect the violet wire to a wire that shows (+)12V when any door is opened, and ground when the door is closed. H1/7 BLUE TRUNK PIN / INSTANT TRIGGER INPUT This input responds to a negative input with an insta

  • 52 © 2008 Directed Electronics. All rights reserved. module are added to the unit, it may be necessary to use the two-chirp setting to program this feature OFF. 3-14 Tach Mode Starter Release: Normal (1) Increase (2) Decrease (3): Use the two-chirp setting to increase time by 15% of the original tach programmed time. Use the three chirp setting to decrease by 15% of the

  • 56 © 2008 Directed Electronics. All rights reserved. Table of zones When using the Diagnostic functions, use the Table of Zones to see which input has triggered the system. It is also helpful in deciding which input to use when connecting optional sensors and switches. ZONE NO. TRIGGER TYPE INPUT DESCRIPTION 1 Trunk Input BLUE (H1/7) 2 Shock Sensor Onboard

  • Python Responder LC Model 991, 29 © 2008 Directed Electronics. All rights reserved. Alarm trigger inputs shorter than 0.8 seconds trigger the WarnAway response, while inputs longer than 0.8 seconds triggers the Full Alarm sequence. Note: You need to add a 4-pin plug to interface with any hardwired switches Tachometer settings  Virtual tach To program Virtual Tach: After the install is complete, remote start the car. 1. If the car does not start on the first attempt, let the remote start attempt 2. again. Once the car starts, let it run until the parking lights come on.3. When the parking

  • Python Responder LC Model 991, 25 © 2008 Directed Electronics. All rights reserved. 5 BLUE/WHITE (-) 200 mA 2ND STATUS/REAR DEFOGGER This wire supplies a 200mA output as soon as the module begins the remote start process. The Blue/White wire can also be used to activate the defogger trigger (latched/pulsed) 10-seconds after the remote start engages. (See the Feature Descriptions, Menu#3, feature #11 for details about programming this output).  Remote start auxiliary output, 5-pin These signals are provided to drive additional optional relays. 1

  • Python Responder LC Model 991, 38 © 2008 Directed Electronics. All rights reserved. For more information about the remote control functions, see the Owners Guide. Button Level Direct Access x 1 x 2 x 3 x 4 ARM/LOCK (Panic) SILENT ARM SENSOR BYPASS SILENT ALARM SENSORS SILENT ALARM ALL ZONES DISARM/UN- LOCK (Panic) SILENT DISARM VALET ON/OFF CAR FINDER STARTER ON/OFF RESET RUNTIME TIMER MODE ON/OFF SMART START ON/OFF DEFOGGER ON A U X TRUNK RELEASE (Red/ White) AUX 1 AUX 2 AUX 3 Advance Level Change Car (3s) Enter programming (8s) CABIN TEMPERATURE RE

  • Python Responder LC Model 991, 35 © 2008 Directed Electronics. All rights reserved. After entering the setup mode on the remotes, use the following learn routine to add remote controls to the system. If the siren generates one long chirp when attempting to program the unit, the learn routine is locked and must be unlocked using the Bitwriter® before pro- ceeding. The Valet/Program switch, plugged into the blue port, is used for programming. There is a basic sequence to remember whenever programming this unit: Door, Key, Choose, Transmit and Release. 1. Open a door. (The GREEN wire, H1/8, or the VIOLET, H1/6 must be connected. 2. Insert the key. Turn the ignition to the ON position. The

  • Python Responder LC Model 991, 19 © 2008 Directed Electronics. All rights reserved. Relay for Negative (-) Disarm Wire Relay for Positive (+) Disarm Wire H2/2 LIGHT GREEN/WHITE (-) 200mA FACTORY ALARM ARM OUTPUT This wire sends a negative pulse every time the remote start shuts down or when the doors are locked with the remote. This can be used to pulse the arm wire of the vehicle’s factory anti-theft device. Use a relay to send a (-) or (+) pulse to the arm wire. H2/3 WHITE/VIOLET (-) 200mA AUX 1 OUTPUT This wire provides 200 mA programmable output whenever the tr

More Instructions:

DOWNLOAD

Related Products and Documents (Car Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Brinkmann PROFESSIONAL STAINLESS STEEL Charcoal Grill Owner's manual brinkmann/professional-stainless-steel-charcoal-grill-Z68.pdf 03 Aug 2022 36 2.46 Mb
2 Dell Dimension 3100C Owner's manual dell/dimension-3100c-P38.pdf 22 Mar 2024 134 2.18 Mb
3 Belkin F1UP0002 Operation & user’s manual belkin/f1up0002-6YM.pdf 21 Oct 2022 839 15.3 Mb
4 Acer model Operation & user’s manual acer/model-41K.pdf 16 Feb 2023 17 0.22 Mb
5 Yamaha RX-V667 Owner's manual yamaha/rx-v667-Q13.pdf 28 Feb 2024 144 57.21 Mb
6 Legacy LA498 Operation & user’s manual legacy/la498-Q9I.pdf 23 Jun 2023 7

Similar Resources:

  • Black Widow Security

    BW 3650

    (12 pages)
    1INSTALLATION MANUAL6 RELAY SYSTEM5-BUTTON SERIESVEHICLE SECURITY SYSTEM Before you begin the installation•Read the INSTRUCTIONS!• Always use a multi-meter when verifyingvehicle wiring.•Before mounting the product,verify withthe customer the desired location for the valetswitch and LED.•Protect the vehicle by using fendercovers.•Always look before …
  • Silencer

    30SL

    (12 pages)
    INSTALLATION MANUALThis unit is designed for professional installation only and must be installed by an authorized Silencer dealer. For Warranty information: Please visit our website at www.magnadyne.com …
  • iDataLink

    ADS-AL(DL)-SUB2-EN

    (28 pages)
    The brand names and logos found in this guide are property of their respective owners. Automotive Data Solutions Inc. © 2017U.S. PATENT NO. 8,856,780TERMS OF USE: Automotive Data Solutions Inc. (“ADS”) products are strictly intended for installation by Certifi ed Technicians who are employed by a registered business specialized in the installation of a …
  • Honda

    08E60-SCV-100

    (2 pages)
    © 2005 American Honda Motor Co., Inc. - All Rights Reserved. AII 31066 (0510) 1 of 2INSTALLATIONINSTRUCTIONSAccessory Application Publications No.Issue DateOCT 200508E60-SCV-1000-912003-2006 ELEMENTKEYLESS ENTRYP/N 08E60-SCV-100PARTS LISTReceiver unitINSTALLATIONCustomer Information: The information in thisinstallation instruction is intended for use only b …
  • Audiovox

    XRO9100

    (24 pages)
    128-82611 of 24Page 1Model XRO9100Owner’s ManualIMPORTANT ! In order to provide you with the highest level of security to yourvehicle, this system is equipped with selectable manual override circuitry. It ispossible that you will need to override you security system if the transmitterbecomes lost, or inoperative due to battery failure. Reading the sect …
  • Alert

    car security system

    (12 pages)
        …

Comments, Questions and Opinions: