Manualios.com

Sunpentown WA-1511S Manual 

Sunpentown WA-1511S Manual Online:

3.65, 2284 votes
Sunpentown WA-1511S User Manual
Sunpentown WA-1511S User Guide
Sunpentown WA-1511S Online Manual

Text of Sunpentown WA-1511S User Guide:

  • Sunpentown WA-1511S, 5 AIR CONDITIONER FEATURES (CONTINUED) NOTE: The following instruction represent the Unit Controls, the same instructions can be used for the Remote Control. TO TURN UNIT ON: DO THIS: Press the On/Off button. TO CHANGE TEMPERATURE SETTING: TO ADJUST FAN SPEEDS: NOTE: Press or hold either Up (▲) or Down (▼) button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 62°F (17°C) and 86°F (30°C). If you want the display to read the actual room temperature, see “To Operate on Fan Only” section.

  • Sunpentown WA-1511S, 1 CONTENTS SAFETY PRECAUTIONS ………………………………...….2 IMPORTANT SAFETY INSTRUCTIONS ……………………3 NORMAL SOUNDS …………………………………………....4 AIR CONDITIONER FEATURES ………………………….…4 INSTALLATION INSTRUCTIONS ………………………….…9 WINDOW MOUNTING ………………………………………11 THROUGH-THE-WALL INSTALLATION ….………………14 MASONRY CONSTRUCTION ………………………………16 CARE AND CLEANING …………………………………...16 TROUBLESHOOTING TIPS …�

  • Sunpentown WA-1511S, 3 NOTE : For some models, the power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section “Operation of Current Device” for details. In the event that the power supply cord is damaged, it cannot be repaired – it must be replaced with a cord from the Product Manufacturer. WARNING – For Your Safety  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.  Avoid fire hazard or electric shock. Do n

  • Sunpentown WA-1511S, 9 INSTALLATION INSTRUCTIONS PARTS LIST AND TOOLS NEEDED TOOLS  A large flat blade screwdriver  Phillips screwdriver  Socket wrenches  Adjustable wrench or pliers  Tape measure  Pencil  Level

  • Sunpentown WA-1511S, 14 NOTE: Consult local building codes prior to installation, or a qualified carpenter.  SELECT WALL LOCATION This unit has a slide-out chassis, so that it can be installed through an outside wall as specified below. Maximum wall thickness:  WA-1511S and WA-1811S = 10”  WA-2211S and WA-2511S = 12” IMPORTANT: Side louvers must never be blocked. NOTE: All parts needed for Through-the-Wall Installation are provided, for the exception of: wood frame, shims, and 10 wood screws (#10-1” long minimum). Select a wall surface that: 1. Does not support any major structural loads, such as the frame construction at the end of windows and

  • Sunpentown WA-1511S, 19 REMOTE CONTROL Location of the remote controller  Use the remote control within a distance of 5 meters (5.5 yards) from the appliance, pointing toward the receiver. Reception is confirmed by a beep. CAUTIONS  The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit.  Prevent any liquid from f alling into the remote controller. Do not expose the remote controller to direct sunlight or heat.  If the

  • Sunpentown WA-1511S, 23 Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired free of charge. This guarantee is subject to the following terms: • Sunpentown must be notified of the fault. • Proof of purchase must be presented to Sunpentown’s nominated representative. • The warranty will be void if the product if modified, misused or repaired by an unauthorized person. • The warranty after repair will not be extended beyond the original one-year period.

  • Sunpentown WA-1511S, 21 USING THE REMOTE Auto Operation Ensure the unit is plugged in and power is available. 1. Press the ON/OFF button to start the air conditioner. 2. Press the MODE button to select AUTO. 3. Press the TEMP UP/DOWN button to set desired temperature. The temperature can be set within the range of 17~30°C/ 62~86°F in 1°C/1°F increments. NOTE  In Auto mode, the unit will choose the operating mode (Cooling or Fan) by sensing the difference between actual ambient temperature and set temperature on the remote  In Auto mode, fan speed canno

  • 2 To prevent injury or property damage, the following instructions must be followed. Failure to follow instructions and incorrect operation may cause harm or damage. Warning marks and classification: WARNING Indicates possibility of death or serious injury. CAUTION Indicates possibility of injury or property damage. WARNING  Ensure plug is firmly con

  • Sunpentown WA-1511S, 18 MODEL WA-1511S WA-1811S WA-2211S WA-2511S Energy Star YES Cooling (BTU) 15,000 18,500 22,000 25,000 Dehumidify (pints/hr) 2.72 3.27 4.18 4.90 EER (BTU/H.W.) 10.7 9.4 Power Input 115V~, 60Hz 230/208V~, 60Hz Amps 12.1 7.7/8.3 10.5/11.3 12/12.8 Watts 1400 1730/1700 2340/2298 2660/2627 Power Cord Length 6 ft NEMA Plug Type #14/LCDI AWG14x3/LCDI #14/LCDI AWG14x3/LCDI Unit Dimension (W x D x H) 23.63 x 25.5 x 17.19 inches 26.5 x 25.5 x 18.63 inches Packing Dimension 26 x 29.94 x 19.69 inches 29.5 x 31.25 x 20.17 inches Net/Gross Weight 99 / 111 lbs 115 / 128 lbs 118 / 132 lbs 122 / 137 lbs Window Width (Min / Max) 26.5 / 40.5 in. 31

  • Sunpentown WA-1511S, 20 REMOTE FUNCTIONS ON/OFF button Operation starts when this button is pressed and stops when the button is pressed again. TEMP UP button Push this button to increase the temperature setting in 1°C/1°F increments to 30°C/86°F. ONE TOUCH button Press this button and system will automatically shift to COOL mode with auto fan speed. The setting temperature is 26°C/80°F. Any timer setting will be cancelled. MODE button Press this button to select the desired operation mod

  • Sunpentown WA-1511S, 4 High Pitched Chatter High efficiency compressors may have a high-pitched chatter during the cooling cycle. Gurgle / Hiss “Gurgling” or “hissing” noise may be heard due to refrigerant passing through evaporator during normal operation. Sound of Rushing Air At the front of the unit, you may hear the sound of rushing air being moved by the fan. Pinging or Switching Droplets of water hitting condenser during normal operation may cause “pinging

  • Sunpentown WA-1511S, 12 10. Your unit may come with internal packaging. These packaging materials must be removed before re-inserting the air conditioner back into cabinet. Fig. 5.  TOP ANGLE RAIL AND SIDE BRACKET INSTALLATION 1. Place cabinet on a flat and sturdy surface. 2. Locate the foam gasket and top angle rail. 3. Attach foam gasket to top angle rail above holes as shown. 4. Install top angle and side retainers to cabinet as shown.  ASSEMBLE WINDOW FILLER PANELS 1. Slide the “I” section of window filler panel into the side retainer. (Fig. 7). Repeat for the other side. 2. Insert top and bottom legs of window filler panel frame into

  • 6 AIR CONDITIONER FEATURES (CONTINUED) TO SELECT THE OPERATING MODE: ENERGY SAVER FEATURE: NOTE:  Press the Mode button to select operating mode. With each press of the button, the mode will go through the following sequence: Auto, Cool, Dry and Fan. The indicator light next to each corresponding mode will illuminate AUTO mode:  When the a

  • 16 1. Cut or build a wall opening in the masonry wall similar to the frame construction (refer to Step 2 of Thru-the- wall Installation for a wall thickness greater than 8-1/2 ). 2. Secure the cabinet in place using masonry nails or masonry anchor screws. Another way to do this is to build an in-between frame of 2x4’s as shown in Step 2 (Prepare Wall). It

  • Sunpentown WA-1511S, 15 4. Build a wooden frame with the INSIDE dimensions of your model listed above. (Best to measure twice). Frame depth should be the same as wall thickness. Fill in extra space from the opening to the studs with wood spacers. 5. Nail the spacers to the studs, they should be flushed with the drywall. NOTE: If wall thickness is 8.5” or more, add aluminum flashing over bottom of frame opening to assure water would not enter area between inner and outer wall.  PREPARE AND INSTALL CABINET

  • Sunpentown WA-1511S, 11  REMOVE CHASIS 1. Pull down the front panel and remove filter. (Fig. 1) 2. Lift front panel upwards and place to one side. 3. Locate the four faceplate screws and remove. These screws will be re-installed later. (Fig. 2) 4. Gently pry the faceplate loose. (Fig. 3) 5. Some models may have a connector plug as shown – disconnect the plug. (Fig. 3A) 6. Pull faceplate away from cabinet and place to one side. (Fig. 4) 7. Remove shipping screws from top of unit and from the side of cabinet, by the base (if installed). 8. Hold the cabinet and pull gently on the base handle to carefully rem

  • Sunpentown WA-1511S, 17 Before calling for service, review this list, it may save you time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance. PROBLEM SOLUTION Air conditioner does not start  Wall plug disconnected. Push plug firmly into wall outlet.  House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.  Plug Current Device tripped, press the RESET button.  Control is OFF, turn control ON and set to desired setting. Air fr

  • Sunpentown WA-1511S, 13  INSTALL SUPPORT BRACKETS 1. Hold each support bracket flush against the outside of window stool. Tighten each bracket to the bottom of cabinet. Mark brackets at top level of window stool and remove. 2. Assemble the sill angle brackets to support brackets at the marked positions. Hand tighten, do not over tighten, to allow for any changes later. 3. Install the support brackets (with sill angle brackets attached) to the bottom of cabinet. 4. Tighten all 6 bolts securely  EXTEND WIN

  • Sunpentown WA-1511S, 10 PRELIMINARY INSTRUCTIONS – STORM WINDOW REQUIREMENTS  Before installing, check the dimensions of your window to make sure the unit will fit. Refer to Table 1.  Sides and rear of unit needs to be clear of obstacles to allow airflow through condenser.  The rear of the unit must be outdoors, not inside a building or garage.  Save carton and installation instructions for future reference. The carton is the best way to store unit during winter, or when not in use.  Please read ALL instructions before ins

  • 8 ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedures, here are some additional features:  The Cool circuit has an automatic 3-minute time delay when unit is turned off and on quickly. This protects the compressor from overheating and possible tripping of the circuit breaker. The fan will continue to run during this time.  The L

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lucent Technologies M770 Operation & user’s manual lucent-technologies/m770-A3O.pdf 22 Nov 2022 72
2 Hobie Adventure Island Owner's manual hobie/adventure-island-ZVL.pdf 14 Mar 2024 8 0.44 Mb
3 Sony VPCL135FX Safety information manual sony/vpcl135fx-KP1.pdf 08 Sep 2023 16
4 Carrier CDT-105E3 Owner's manual carrier/cdt-105e3-I7K.pdf 06 Nov 2022 7
5 Melitta MEVA10DB Use & care manual salton/meva10db-KVZ.pdf 01 Dec 2023 18 0.07 Mb
6 D-Link DFE-530TX Operation & user’s manual d-link/dfe-530tx-3N3.pdf 26 Sep 2022 30

Similar Resources:

  • Carrier

    42LUVH055N

    (41 pages)
    Air Conditioner Service Manual DC Inverter Hi-Wall Model Description Refrigerant Power supply 42/38LUVH055N 21K HP R410A 1Ph,220-240V,50Hz 42/38LUVH065N 24K HP R410A 1Ph,220-240V,50Hz 42/38LUVH075N 2 …
  • Ballu

    KFR-28GW/BP Series

    (70 pages)
    CONTENTSKFR - 5701GW/Y2BPEKFR - 2601GW/BPE*2 KFR - 28 GW/BPE*2SERVICEMANUALSPLIT TYPE INVERTER AIR CONDITIONER1.PART NAMES AND FUNCTIONS...........2.SPECIFICATION...................................3.OUTLINES AND DIMENSIONS..............4.WIRING DIAGRAM ...............................5.REFRIGERANT SYSTEM DIAGRAM ......6 …
  • Panasonic

    CS-MKS24NKU

    (2 pages)
    Split System Submittal DataIndoor: CS-MKS24NKU Multi System Indoor Units - Wall MountedApproval:Date:Construction:Unit#:Drawing#:Job Name:Location:Engineer:Submitted to:Submitted by:Reference:General DataPower (V/P/Hz) 208 - 230/1/60Circuit Ampacity (A) 15Fuse Size, Max.(A) 20Running Amps (A) 0.20Power Input (W) 45Indoor Unit Fan type Cross FlowDia & …
  • Saunier Duval

    SDH 17-035 NW

    (136 pages)
    WALL-MOUNTED UNITSSDH 17-025 NWSDH 17-035 NWSDH 17-050 NWSDH 17-065 NWBedienungsanleitungUser ManualManual de UsuarioManuale di IstruzioneInstrukcja obsługiManual de InstruçõesPTPLITESENAT …
  • Audi

    A8 1994

    (91 pages)
    Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability with respect to the correctness of information in this document. Copyright by AUDI AG.Body repairsAudi A8 1994 ➤Edition 10.1998ServiceService Department. Technical I …
  • Bryant

    581A

    (56 pages)
    Cancels: II 581A-210-1 II 581A-210-210/1/05installation, start-up andservice instructionsSINGLE PACKAGE ROOFTOPELEC TRIC COOLING/GAS HEATING UNITS581ADuraPac Plus SeriesSizes 210-30018 to 25 TonsCONTENTSPageSAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . 1INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …

Comments, Questions and Opinions: