Manualios.com

Sylvania Air Conditioner Owner's Manual

Sylvania Air Conditioner Manual Online:

4.45, 2856 votes
Sylvania Air Conditioner User Manual
Sylvania Air Conditioner User Guide
Sylvania Air Conditioner Online Manual

Text of Sylvania Air Conditioner User Guide:

  • Sylvania Air Conditioner, PORTABLE AIR CONDITIONER Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. Before operating this product, please read the instructions carefully and save this manual for future use.

  • Sylvania Air Conditioner, CONTENTS The rating data indicated on the energy label is based on the testing condition of installing the un-extended air exhaust duct without adaptor A & B (The duct and the adaptor A & B are listed in the accessories chart of the Instruction Manual). NOTE 1 SAFETY PRECAUTIONS Safety rules .......................................................................................................................................2 Operating condition ...........................................................................................................................2 Electrical information ...................................

  • Sylvania Air Conditioner, To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Always transport your air conditioner in a vertical position and stand on a stable, level surface during use. Turn off the product when not in use. Always contact a q

  • Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against s

  • Sylvania Air Conditioner, IDENTIFICATION OF PARTS NAMES OF PARTS Fig.2 Front Operation Panel Horizontal Louver Blade (swing automatically) Caster Carrying Handle (both sideV) 1 2 3 4 1 2 3 4 1 2 3 4 5 Model A Model B Operation Panel Horizontal Louver Blade (manually) Remote signal receptor Caster Carrying Handle (both sideV) 1 2 3 4 5 Fig.1 Fig.3 Rear 9 6 7 8 10 11 6 7 8 9 10 11 Upper Air Filter (Behind the grille) Air Outlet Power cord outlet Air intake Drain Outlet Air intake Lower Air Filter (Behind the grille) Bottom tray drain outlet 12 12 13 13 4

  • Sylvania Air Conditioner, AIR CONDITIONER FEATURES Before you begin, thoroughly familiarize yourself with the control panel and remote controller and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control panel alone or with the remote controller. ELECTRONIC CONTROL OPERATING INSTRUCTIONS Fig.4 NOTE: This manual does not include Remote Controller Operations, see the <<Remote Controller Instruction>> packed with the unit for details. OPERATION PANEL OF THE AIR CONDITIONER 6 2 3 4 5 7 8 1 Selects the appropriate operating m

  • OPERATING INSTRUCTIONS Press the ION button, the ion generator is energized and will help to remove pollen and impurities from the ai U, and trap them in the filter. Press it again to stop the function. 8 ION button(optional) Operating Instructions - Press the "MODE" button until the "COOL" indicator light comes on. - Press the ADJU

  • Sylvania Air Conditioner, OPERATING INSTRUCTIONS Other features In the case of a power outage or interruption, the unit will automatically re-star WDIWHUWKH power is restored. Power Outage After the unit has stopped, it cannot restart operation in the first 3 minutes. This is to protect the unit. Operation will automaticDlOy start after 3 minutes. Wait 3 minutes before resuming operation The louver can be adjusted manually or automatically according to the different models. Adjust the air flow direction manually (Fig.5): The louver can be set

  • Sylvania Air Conditioner, INSTALLA TION INSTR UCTIONS Horizontal window Window Slider Kit Minimum:67.5cm(2.22ft). Maxmum:123cm(4.04ft). Window Slider Kit Minimum:67.5cm(2.22ft). Maxmum:123cm(4.04ft). Horizontal window Fig.8 Fig.9 Fig.7 Location The air conditioner should be placed on a firm foundation to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit. The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet

  • Sylvania Air Conditioner, INSTALLATION INSTRUCTIONS Installation in a double-hung sash windows 1. Cut the foam seal(adhesive type) to the proper length and attach it to the window sLOl. Fig.10 2. Attach the window slider kit to the window sLOO. Adjust the length of the window slider kit according to the width of window, shortHQ the adjustable window kit if the width of window is less than 27 inches. Open the window sash and place the window slider kit on the window sLOO. Fig.11 3. Cut the foam seal(adhe

  • Sylvania Air Conditioner, INSTALLATION INSTRUCTIONS 10 Installation in sliding sash windows 1. Cut the foam seal(adhesive type) to the proper length and attach it to the window frame. See Fig.14. 2. Attach the window slider kit to the window sill. Adjust the length of the window slider kit according to the length of window, shortHQ the adjustable window kit if the length of window is less than 27 inches. Open the window sash and place the window slider kit on the window sLOO. See Fig.15. 3. Cut the foam seal(adhesive type) to the proper length and attach it on the top of the

  • Sylvania Air Conditioner, INSTALLATION INSTRUCTION S Exhaust hose installation: The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. COOL mode FAN or DEHUMIDIFY mode Install Remove The duct can be compressed or extended moderately according to the installation requirement, but it is desirable to Refer to page 4. Adapter A is available for purchase. JC Global/Sylvania is not responsible for any construction costs. keep the duct length to a minimum. 1. Install the window Exhaust adaptor B onto the e

  • Sylvania Air Conditioner, INSTALLATION INSTRUCTIONS Water drainage: - During dehumidifying modes, remove the drain plug from the back of the unit, install the drain connector(5/8 universal female mender) with 3 4 hose(locally purchased). For the models without drain connector, just attach the drain hose to the hole. Place the open end of the hose directly over the drain area in your basement floor. Please refer to Fig.23 & 24. - When the water level of the bottom tray reaches a predetermined level, Ca

  • CARE AND MAINTENANCE CARE AND MAINTENANCE 1) Be sure to unplug the unit before cleaning or servicing. 2) Do not use gasoline, thinner or other chemicals to clean the unit. 3) Do not wash the unit directly under a tap or using a hose. It may cause electrical danger. 4) If the power cord is damaged, it should be repaired by WKH

  • Sylvania Air Conditioner, TROUBLESHOOTING TIPS TROUBLE SHOOTING 1. Unit does not Start when Pressing on/off Button TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES Reset the temperature. Make sure all the windows and doors are closed. Remove the heat sources if possible. Connect the duct and make sure it can function properly. Decrease the set temperature. Clean the air filter. - Room temperature is lower than the set temperature.(Cooling mode) - The windows or doors in the room are not closed. - There are heat sources inside the room. - Exhaust air duct is not connected or blocked. - Temper

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Oster TSSTTRUS Instruction manual oster/tssttrus-7B7.pdf 11 Dec 2023 9
2 Skope BC070-CB Operation & user’s manual skope/bc070-cb-G8A.pdf 11 Nov 2023 18
3 Audio Research VT130 Owner's manual audio-research/vt130-84M.pdf 16 Aug 2022 9
4 REVELL MiG 21 PF Assembly manual revell/mig-21-pf-31D.pdf 03 Dec 2023 12 1.83 Mb
5 Teac SL-D910 Service manual teac/sl-d910-546.pdf 27 Jan 2024 36
6 Chargery Power S1500 Instruction manual chargery-power/s1500-3KX.pdf 26 Oct 2023 8

Similar Resources:

  • Fedders

    23-23-0275N-009 s

    (32 pages)
    Including Service and WarrantyIncluidos mantenimiento y la garantfaAvec service et garantieRoom Air Conditioners for Through-The-Wall InstallationAcondicionadores de aire para instalaci6n atravesando la paredClimatiseur d'air individuel pour installation murale dans une gaine …
  • Lennox

    LGH150H

    (48 pages)
    ©2020WARNINGImproper installation, adjustment, alteration, service or maintenance can cause property damage,personal injury or loss of life. Installation and service must be performed by a licensed professionalHVAC installer or equivalent, service agency, or thegas supplierCAUTIONAs with any mechanical equipment, contact withsharp sheet metal edges ca …
  • Zibro

    R 24 C

    (16 pages)
    214263850627486MANUEL D'UTILISATIONGEBRAUCHSANWEISUNGBRUGSANVISNINGINSTRUCCIONES DE USOOPERATING MANUALISTRUZIONI D’USOBRUKSANVISNINGGEBRUIKSAANWIJZING32654>u1R 24 C …
  • Panasonic

    CS-MKE24NKU

    (2 pages)
    Split System Submittal DataIndoor: CS-MKE24NKU Multi System Indoor Units - Wall MountedApproval:Date:Construction:Unit#:Drawing#:Job Name:Location:Engineer:Submitted to:Submitted by:Reference:General DataPower (V/P/Hz) 208 - 230/1/60Circuit Ampacity (A) 15Fuse Size, Max.(A) 20Running Amps (A) 0.15Power Input (W) 45Indoor Unit Cool/HeatFan type Cross FlowDi …
  • Toshiba

    MMY-MAP0806FT8P-E

    (92 pages)
    AIR CONDITIONER (MULTI TYPE)Installation ManualOutdoor UnitModel name:MMY-MAP0806FT8P-EMMY-MAP1006FT8P-EMMY-MAP1206FT8P-EMMY-MAP1406FT8P-EMMY-MAP1606FT8P-EMMY-MAP1806FT8P-EMMY-MAP2006FT8P-EMMY-MAP0806FT8JP-EMMY-MAP1006FT8JP-EMMY-MAP1206FT8JP-EMMY-MAP1406FT8JP-EMMY-MAP1606FT8JP-EMMY-MAP1806FT8JP-EMMY-MAP2006FT8JP-EFor commercial useEnglish11177010011117701001 …
  • Carrier

    CPLPCONV006A00

    (8 pages)
    Small Packaged ProductsStandard Altitude Only 0–2000 ftAccessory LP Conversion KitInstallation Instructions60,000–130,000 Btu/hrPart Number: CPLPCONV006A00 2 to 5 TonsNOTE: Read the entire instruction manual before starting theinstallation.This symbol → indicates a change since the last issue.SAFETY CONSIDERATIONSInstalling and servicing air conditioni …

Comments, Questions and Opinions: