  • CMX15 Boiler
  • maSMHE5EALZRw
  • Installation Instructions And User Manual
  • PDF / Adobe Acrobat Reader
  • 21

Gabarron CMX15 Manual Online:

4.5, 1895 votes
Gabarron CMX15 User Manual
Gabarron CMX15 User Guide
Gabarron CMX15 Online Manual

Text of Gabarron CMX15 User Guide:

  • Gabarron CMX15, DIGITAL MODULATING BOILERS FOR HEATING AND SANITARY HOT WATER CMX15 CM15 CMX18 CM18 INSTRUCCIONES DE INSTALACIÓN Y USO INSTALLATION INSTRUCTIONS AND USER GUIDE Lea estas instrucciones atentamente antes de instalar o utilizar el aparato por primera vez. Please read these instructions before installing or using this appliance for the first time. INDEX

  • Gabarron CMX15, 2 Gabarrón CM&CMX 1 IMPORTANT……………………………………………………………………………….. 18 2 INSTALLATION…………………………………………………………………………….. 19 3 COMMISIONING…………………………………………………………………………. 19 3.1 HEATING…………………………………………………………………….. 19 3.2 SANITARY HOT WATER……………………………………………….. 20 4 LIMITATION OF THE MAXIMUM OUTPUT………………………………….. 20 5 DESCRIPTION OF THE CONTROL PANEL………………………………

  • Gabarron CMX15, 3 1 IMPORTANT • The boiler’s guarantee does not cover any damaged caused by the non-observance of any of these instructions. • This manual must be conserved and given to any new user. • This appliance is not destined for use by anyone (including children) with reduced physical, sensorial or mental capacities or those who do not know how to use the appliance, unless they are supervised or instructed by a person responsible for their safety. • Check that the voltage on the indicator plate of the boiler coincides with the voltage of the mains circuit to which it is go

  • 4 Gabarrón CM&CMX P UPS 25-40 (kPa) 40 4 3 2 1 0 0 20 40 60 (l/min) 0 0 0.5 1 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q(m /h) 3 H(m) 20 0 Working curves of the accelerator pump. 2 INSTALLATION Ensure that the mains voltage available coincides with that shown on the rating label. The electrical installation must comply with the current regulations. The cross-section

  • Gabarron CMX15, 5 Start the heating by pushing the button the heating display will light up. Select a set point higher than the temperature indicated on the heating display and check the consumption once the operating indicator of the central heating resistances lights up. The S.H.W. has priority; if the S.H.W. is connected and consuming, this point cannot be verified. Purge the installation again if necessary. Reinstate any possible losses in pressure by opening the filling valve until the pressure gauge reads between 1 and 1.5 bar. If the boiler includes the option of radiant floor heating (requested on placing the order), the central heat

  • Gabarron CMX15, 6 Gabarrón CM&CMX Move the switches with a small screwdriver and make them coincide with the corresponding combination on the tables for each boiler model. Replace the front panel following the steps in reverse and connect the boiler to the mains. IMPORTANT: Check immediately before activating the modulation system with a hook-on meter that the consumption corresponds to the output selected. On the CMX models, turn off the S.H.W. pressing the button to verify the heating consumption. Location of electronic card. Location of the switches. ATTENTION! The switches are upside down.

  • Gabarron CMX15, 7 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON POSITION OF THE SWITCHES MAXIMUM OUTPUT LIMITED TO : MAX. CURRENT PHASE :R MAX. CURRENT PHASE : S MAX. CURRENT PHASE :T 15kW 21.7A 21.7A 21.7A 13kW 13.0A 21.7A 21.7A 12kW 21.7A 21.7A 8.7A 11kW 13.0A 13.0A 21.7A 10kW 21.7A 8.7A 13.0A 9kW 13.0

  • Gabarron CMX15, 8 Gabarrón CM&CMX MODELS CMX18 & CMX15 MODELS CM18 & CM15 Increase heating water temperature S.H.W. temperature and other messages Heating temp. and other messages Increase S.H.W. temperature Blockage indicator S.H.W. On / Off button On / Off button Block / Unblock Reduce S.H.W. temperature Heating On / Off button Heating resistances operating indicator calefacción bl

  • Gabarron CMX15, 9 6 USING THE BOILER 6.1 TURNING ON AND OFF When the boiler is connected to the mains it will perform a general self-check and, if any defect is detected, it will be indicated on the heating or S.H.W. displays. Push the button to start the boiler up. The same button will turn the boiler off when pushed again. If the heating display only shows a small red dot, the heating function is switched off. To start the heating, push the button. The same occurs with the Sanitary Hot

  • Gabarron CMX15, 10 Gabarrón CM&CMX The heating setting can be varied between 8 and 85°C. The symbol H appears after the 85 value or before the 8 value. If we select this value, the heating will function in anti-freeze mode: if the temperature falls below 7°C, the boiler will connect automatically. 6.3.1 AMBIENT THERMOSTAT The optimum operation of the heating installation is achieved when an ambient thermostat or ambient chrono thermostat is connected to the boiler. Connect the normally open contact of the ambient thermostat to the terminals of the electronic card of the boiler in substitution of the bridge. 6.3.2 MODULATION

  • Gabarron CMX15, 11 6.3.4 HEATER SAFETY FLOW FAILURE If the error E3 appears on the display, the boiler has detected a flow failure in the heating circuit. The possible causes of this error are: - A blocked pump. - All the thermostat valves are closed and there is no circuit that permits the water return. - The circuit pressure is insufficient. - The heating circuit is blocked. After solving the cause of the error, the boiler must be turned off and re-started to eliminate the display message. HEATER OVERHEATING If the error E4 appears on the display, the boiler has detected overheating in the heating circuit. Once t

  • 12 Gabarrón CM&CMX 6.4 SANITARY HOT WATER (S.H.W.) The CMX15 and CMX18 boilers have a mixed function of modulated heating and the preparation of sanitary hot water. The S.H.W. function has priority over the heating and so the outputs are never added together. A 50-litre header tank lagged with CFC free insulation accumulates the sanitary hot

  • Gabarron CMX15, 13 7 MAINTENANCE Gabarrón electric boilers do not need any special maintenance, only the following should be checked: -Check the pressure indicated by the pressure gauge frequently, ensuring that it is between 1 and 1.5 bar when cold. - Never start the boiler when it is empty. - Never start the boiler when the S.H.W. tank is empty; to fill it for the first time open a hot water tap and wait until water comes out of it. -Precaution against freezing. In dwellings that are frequently unoccupied or at risk of freezing, an anti-freeze of the appropriate quality can be added to the water of the heating installation – the concentration must not exceed 30% in volume.

  • 14 Gabarrón CM&CMX 9 TECHNICAL DATA CMX15 CMX18 CM15 CM18 Frequency Hz 50 50 50 50 Connection 3x400V+N~     Output limited to 18kW; Maximum intensity A - 26.0 - 26.0 Output limited to 15kW; Maximum intensity A 21.7 26.0 21.7 26.0 Output limited to 13kW; Maximum

  • 16 Gabarrón CM&CMX 10 ENVIRONMENTAL INFORMATION Gabarrón boilers are manufactured within a certified environmental management system. From the design stage, all the production phases are performed taking into account the most rigorous environmental requirements. For example, the selection of materials involves guaranteeing their biodegradability, re-use and recyclin

  • Gabarron CMX15, 20 Gabarrón CM&CMX www.elnur.es Fabricado por: Manufactured by: ELNUR s.a. Pol. Ind. “El Nogal” Villa Esther, 11 28110, ALGETE - Madrid Departamento de atención al cliente: Customer Service Department: +34 902 19 57 14 Como parte de la política de mejora continua, Elnur s.a. se reserva el derecho a realizar modificaciones técnicas sin previo aviso. As a part of the policy of continuous product improvement, Elnur s.a

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lexmark X792 Quick reference lexmark/x792-FG2.pdf 04 Dec 2023 3
2 Ko Propo KR-409S Instruction manual ko-propo/kr-409s-27L.pdf 01 Feb 2024 1
3 Inoksan WD900SL23-5S Owner's manual inoksan/wd900sl23-5s-LD4.pdf 16 Oct 2023 8
4 Hatteland JH I2TOI MMC Operation & user’s manual hatteland/jh-i2toi-mmc-WM5.pdf 16 Nov 2022 36 2.98 Mb
5 Zaxcom Nomad Operation & user’s manual zaxcom/nomad-531.pdf 28 Dec 2023 3
6 Panasonic TX-P42X60B Operating instructions manual panasonic/tx-p42x60b-Y32.pdf 08 Jun 2023 32

Similar Resources:

  • Beretta

    EXCLUSIVE BOILER GREEN 30 B.S.I.

    (116 pages)
    EXCLUSIVEBOILER GREEN30 B.S.I.EN INSTALLER AND USER MANUALES MANUAL DE INSTALACIÓN Y USOPT MANUAL PARA INSTALAÇÃO E USOHUTELEPÍTŐI ÉS FELHASZNÁLÓI KÉZIKTELEPÍTŐI ÉS FELHASZNÁLÓI KÉZIKTELEPÍTŐI ÉS FELHASZNÁLÓI KÉZIKTELEPÍTŐI ÉS FELHASZNÁLÓI KÉZIKTELEPÍTŐI ÉS FELHASZNÁLÓI KÉZIKÖNYÖNYÖNYÖNYÖNYVVVVVROMANUMANUMANUMANUMANUAL D …
  • Ferroli

    PEGASUS D 30 K 100 LN

    (76 pages)
    PEGASUS D 30 K 100 LNIT - ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONEES - INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTOTR - KULLANMA, KURULUM VE BAKøM TALIMATLARøEN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCEFR - INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIENRU - ɊɍɄɈȼɈȾɋɌȼɈ ɉɈ ɗɄɋɉ …
  • Hydrolevel Company

    Safgard 400 Series

    (4 pages)
    WARNING – To prevent electrical shock orequipment damage, power must be off duringinstallation or servicing of the control. To pre-vent serious burns, the boiler should be thor-oughly cooled before installing or servicing con-trol. Only qualified personnel may install or ser-vice the control in accordance with local codesand ordinances. Read instructions c …
  • Baxi

    Luna 3 Comfort

    (288 pages)
    caldaia murale a gas ad alto rendimento manuale per l’uso destinato all’utente ed all’installatoreITHigh efficiency wall-mounted gas-fired boilersInstaller’s and User’s InstructionsGBCaldera mural de gas de alto rendimiento Manual para el usuario y el instaladorESВысокопроизводительный настенный газовый ко� …
  • Smith

    70-195

    (40 pages)
    This manual is intended only for use by a qualified heating installer/technician. Read and follow this manual, all supplements and relatedinstructional information provided with the boiler. Install, start and service the boiler only in the sequence and methods given in these in-structions. Failure to do so can result in severe personal injury, death or subst …
  • Froling

    FHG Turbo 3000

    (25 pages)
    Operating Instructions FHG Turbo 3000 Read and follow the operating instructions and safety information. Edition: 02/2005 Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen Tel. +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 [email protected] www.froeling.com …

Comments, Questions and Opinions: