Manualios.com

E.C.A. Confeo Premix User Operating Instructions Manual

  • Confeo Premix Boiler
  • maX2kWLFBVS8U
  • User Operating Instructions Manual
  • PDF / Adobe Acrobat Reader
  • 7

E.C.A. Confeo Premix Manual Online:

4.9, 639 votes
E.C.A. Confeo Premix User Manual
E.C.A. Confeo Premix User Guide
E.C.A. Confeo Premix Online Manual

Text of E.C.A. Confeo Premix User Guide:

  • E.C.A. Confeo Premix, High-efficiency Condensing Boilers (60/100 mm Flue Outlet) Confeo Premix CP 24 HM GC Appliance No. 47-144-03 24 kW Central Heating Output 26 kW Domestic Hot Water Output Confeo Premix CP 30 HM GC Appliance No. 47-144-04 30 kW Central Heating Output 31 kW Domestic Hot Water Output USER OPERATING INSTRUCTIONS Veruk23308

  • E.C.A. Confeo Premix, PREFACE Confeo Premix high-efficiency condensing boilers have been designed to provide efficient, safe and comfortable central heating (CH) and domestic hot water (DHW). This section of the manual contains user’s operating instructions. Please read the instructions carefully before operating the boiler to maximise efficiency and benefit from the boilers specification . GUARANTEE & SERVICE  ECA Heating UK guarantee this boiler for a period of up to 2 years from date of installation against manufacturing and material defect subject to the following terms & conditions. �

  • E.C.A. Confeo Premix, BOILER CONTROLS Control Panel ON/OFF Switch Display Panel: Blue Backlit LCD Display and 4 Yellow Status LED's Central Heating (CH) Temperature Control Knob Domestic Hot Water (DHW) Temperature Control Knob Pressure Push-button Reset Push-button / Burner LED Control Panel Cover 2 4 5 7 3 1 Fig 1 6

  • E.C.A. Confeo Premix, Operating The Boiler Start Up / Shut Off The Boiler Turn the ON/OFF switch to ‘ ON ’ position. LCD display will turn ON and, Power-on sequence will be monitored for several seconds. After the power-on sequence is completed successfully, LCD display shows actual Central Heating (CH) flow temperature. Fig 2 Status LEDs CH / DHW when OFF indicate “stand-by” mode, no demand for DHW or CH. CH (Cen

  • E.C.A. Confeo Premix, DHW (Domestic Hot Water) Mode It is possible to have domestic hot water when: a) The appliance is in standby-by mode or, Fig 8 b) CH mode is active. DHW has priority over CH mode. Ensure control knob is not in DHW cancellation zone. Turn ON a hot tap to start DHW mode Turn OFF the hot tap to stop DHW mode. The boiler goes back to the previous mode. Fig 9 Domestic hot water temperature can be adjusted between 35 o C and

  • System Pressure Fig 12 System pressure should be within the range of 0.8 bar – 1.5 bar when boiler is cold (for outside this range, see below). This pressure will increase as the system becomes hot up to a maximum pressure of 3 bar. To check system pressure, on / off switch must be set to ON position. Depr

  • E.C.A. Confeo Premix, User Self Help Fault Guide This guide is intended for user's self help only. For technical in depth fault finding please see installation & service instructions. Your Confeo Premix boiler has a built in self checking function and fault diagnosis display. These fault codes will help to interpret the nature of fault. Some faults conditions will be reset by pressing the Reset Push-button / Burner LED (fig 1) which will be RED if a fault condition occurs or by an automatic reset if fault is corrected. Fault finding actions should only be under taken where user is competent to undertake. Table 1 Fault Display Reme

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Philips HR7761 Operation & user’s manual philips/hr7761-28K.pdf 03 Oct 2023 8
2 Riccar 2910 Instruction manual riccar/2910-445.pdf 08 Aug 2023 43 2.68 Mb
3 Cobra PR3175WX Owner's manual cobra/pr3175wx-4ED.pdf 13 Nov 2022 16 0.69 Mb
4 Panasonic FV-08-11VFL5 Service manual panasonic/fv-08-11vfl5-LG8.pdf 01 Aug 2022 7
5 Toshiba TXZ Family Reference manual toshiba/txz-family-44Q.pdf 18 Feb 2023 14
6 Kenwood KTC-9090DAB Instruction manual kenwood/ktc-9090dab-1JS.pdf 10 Aug 2023 15

Similar Resources:

  • IDEAL

    Vogue S15

    (72 pages)
    simply advancedinstallationand servicingSYSTEM boilErs15, s18, s26, s32When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal. For the very latest copy of literature for s …
  • LAMBORGHINI

    FAST 30 C - SCHEMA

    (28 pages)
    WALL-HUNG, GAS-FIRED,SEALED BOILER,FOR CENTRAL HEATINGOPERATING, INSTALLATIONAND MAINTENANCEINSTRUCTIONScod. 3540T54/0 - 04/2009 (Rev. 00)7Externa 30 O …
  • Glow-worm

    Flexicom 12hx

    (52 pages)
    Installation and ServicingCondensing Boilers/Flexicom hx12 hx G.C.No. 41-315-2815 hx G.C.No. 41-315-2918 hx G.C.No. 41-315-4224 hx G.C.No. 41-315-6130 hx G.C.No. 41-315-6735 hx G.C.No. 41-315-68 …
  • Malvern

    tentwenty

    (2 pages)
    USER INSTRUCTIONStentwenty & twentytwentysixCONDENSING BOILERSINFORMATION CONCERNING YOUR BOILERYou are the owner of a Malvern High Efficiency Condensing Boiler and due to theway it works it will appear to produce a lot of steam from the terminal; this is harmlessvapour and quite normal. The boiler requires a drain to be permanently connected,your insta …
  • Lamborghini Caloreclima

    NINFA 32 MC

    (28 pages)
    *cod. 3540G380 — 02/2007 (Rev. 00)NINFA 32 MCISTRUZIONI PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCEINSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIENINSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTOINSTRUÇÕES DE INSTALAÇÃO, UTILIZAÇÃO E MANUTENÇÃO …
  • Electric Heating Company

    SlimJim

    (16 pages)
    Electric Flow Boiler INSTALLATION & TECHNICAL MANUALIf you require any further assistance:Telephone: 01698 820533Fax: 01698 825697E-mail: [email protected] visit our website www.electric-heatingcompany.co.uk …

Comments, Questions and Opinions: