Manualios.com

E.F. Johnson Company 5100 ES Operating Manual

E.F. Johnson Company 5100 ES Manual Online:

4.55, 1313 votes
E.F. Johnson Company 5100 ES User Manual
E.F. Johnson Company 5100 ES User Guide
E.F. Johnson Company 5100 ES Online Manual

Text of E.F. Johnson Company 5100 ES User Guide:

  • E.F. Johnson Company 5100 ES, 3-6 ES Series Models II/III Portable Radio Operating Manual General Operation Proceed as follows to select channels using this mode: 1 Enable the direct Channel Select mode by pressing the Channel Select option with or selecting the “Chan Selct” menu parameter. The alias and sequential number of the current channel are alternately displayed. 2 Select the desired channel using the Up/Down buttons or directly enter it using the 0-9 keys (if available). If using the 0-9 keys, the radio attempts to d

  • ES Series Models II/III Portable Radio Operating Manual 1-5 Features 1.5 Multi-Net Features • Up to 864 channels or talkgroups programmable • Up to 32 RF sites per system • Up to 16 systems (home repeaters) • Roaming with auto or manual registration • Call indicator (future release) • Telephone, Unit (Unique ID), and Directed Group calls • Receive priority 1 and

  • E.F. Johnson Company 5100 ES, ES Series Models II/III Portable Radio Operating Manual 5-13 Conventional Mode Features The priority channel sampling feature ensures that when priority scanning, messages on the priority channel are not missed while listening to a message on some other channel. The radio can be programmed as just described so that the priority channel is a fixed channel programmed in the current scan list, the currently selected channel, or not used. Note Priority channel sampling is not available when receiving analog encrypted (DES) calls, nor when receiving unit calls. In addition, the priority channel is not scanned if the active channel is an analo

  • E.F. Johnson Company 5100 ES, 2-12 ES Series Models II/III Portable Radio Operating Manual Controls and Display Keyloader/Menu Exit Mode Exit Menu Mode, Keyloader Detached High pitched beep followed by a medium pitched beep Keypress Low Battery The battery strength is getting low. Charge or replace the battery immediately Two medium pitched beeps Action Message / Status ACK Message / Status Acknowledgement has been Received Six medium pitched beeps Action Multi-Net Talk Permit Tone Multi-Net Directed Talkgroup Talk Permit Tone Medium pitc

  • ES Series Models II/III Portable Radio Operating Manual 7-9 Multi-Net Features The group scan feature monitors the currently registered site for calls with the home channel number and group IDs of the home channel of the current scan list. When a call is detected, scanning stops and the message is received. Shortly after the message is complete, scanning r

  • ES Series Models II/III Portable Radio Operating Manual 12-3 Data Features 1 Using the Control Panel, access the Network Connection screen (Figure 12.1). Figure 12.1 Network Connection Screen 2 Click Create a new connection link.The New Connection Wizard screen appears (Figure 12.2). 3 Click Next. The Network Connection Type screen appears (Figure 12.3).

  • E.F. Johnson Company 5100 ES, ES Series Models II/III Portable Radio Operating Manual 6-17 SMARTNET / SmartZone / P25 Trunked Features 2 Talk and listen as usual. When dynamic regrouping is canceled by the dispatcher, a short tone sounds. If a standard channel is not selected after this occurs, transmission is not allowed if the talkgroup is assigned as a dynamic regrouping talkgroup only. If it is assigned as a normal talkgroup, normal transmissions are allowed. 6.12 SmartZone and P25 Trunked Unique Features P25 Trunked and SmartZone modes can provide access to single or multi-site systems. The P25 Trunked mode can provide access to a single trunked site or roaming between several trunked sites. 6.12.1 Signal St

  • E.F. Johnson Company 5100 ES, ES Series Models II/III Portable Radio Operating Manual 3-3 General Operation When the volume control buttons are used, the number of steps (ticks) required to change the volume from the minimum level to maximum level is programmable for 2-50. For example, if “20” is programmed, there are 20 adjustment steps from minimum to maximum volume. Only one volume control button can be programmed if desired and wrap-around then occurs after the maximum or minimum level is selected. The radio can also be programmed so that volume control is also be disabled by the Keyp

  • E.F. Johnson Company 5100 ES, ES Series Models II/III Portable Radio Operating Manual 5-1 S ECTION Section 5Conventional Mode Features An overview of the conventional operating mode is located in Section 3.9.1. The following information describes the features unique to analog and digital (Project 25) conventional operation. Refer to the preceding “Radio Wide Features” (Section 4) for information on features common to all operating modes. 5.1 Monitoring Before Transmitting With conventional operation, you may need to manually monitor the channel before transmitting

  • E.F. Johnson Company 5100 ES, 5-26 ES Series Models II/III Portable Radio Operating Manual Conventional Mode Features • Unlimited - Telephone numbers can be selected from a list and also dialed directly using the keypad. Both limited and DTMF keypad models can place telephone calls by recalling the telephone number from a pre programmed list as just described. However, only DTMF keypad models can directly dial telephone numbers using the keypad. 5.14.9.1 Access / De-Access Codes P25 conventional telephone calls use an access code to access the system when placing a telephone call, and a de-access code to terminate the call when it is

  • E.F. Johnson Company 5100 ES, 4-6 ES Series Models II/III Portable Radio Operating Manual Radio-wide Features 4.5 Function Recall A function recall button or menu item can be programmed so that if the user presses this button or activates its menu item, the radio enters Function Recall mode, and the display flashes “Fnc Recall”. Pressing any button displays the function assigned to that button for a specified period. If that same button is pressed again during the specified period, the radio performs the function assigned to that button and then exits Function Recall mode. F

  • E.F. Johnson Company 5100 ES, ES Series Models II/III Portable Radio Operating Manual 5-5 Conventional Mode Features 5.4.3 Digital Call Guard Squelch Digitally Coded Squelch (DCS) uses digital data instead of subaudible tones to control the squelch. When the push-to-talk switch is released, a turn-off code is transmitted which eliminates the squelch tail similar to the reverse burst. 5.4.4 Call Guard Disable A programmed option lets the radio disregard any CTCSS/DCS or NAC/Talkgroup information on the current channel. This feature is best described as a monitor mode with no white noise. In analog it is functionally the same as turning the squelch mode to “normal.” In digital mode it

  • E.F. Johnson Company 5100 ES, ES Series Models II/III Portable Radio Operating Manual i Table of Contents ES Series Models II/III Portable Radio Operating Manual October 2011 Safety Requirements ix 1 Features 1-1 General Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Conventional Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 SMARTNET / SmartZone Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • E.F. Johnson Company 5100 ES, 4-16 ES Series Models II/III Portable Radio Operating Manual Radio-wide Features - Number of satellites that the receiver is currently receiving 4 You can cycle through the data items using the “Up” and “Down” buttons. If data is not available for an item, the display shows “No Data”. Note The GPS viewing mode remains active for 60 seconds after the last user input. 5 To exit GPS viewing, press the assigned GPS button or press the “Clear” button (F1). 4.13.2 Sending GPS Data The radio can send GPS data in conventi

  • E.F. Johnson Company 5100 ES, 6-20 ES Series Models II/III Portable Radio Operating Manual SMARTNET / SmartZone / P25 Trunked Features With the Zone Fail Site Lock feature enabled, the radio continues to roam normally when the system zone controller is active. However, if the zone controller fails, this is detected and the Zone Fail Site Lock mode is entered. The only site the radio is then allowed to operate on is its home site. If its home site is not available, “Out-of-Range” is displayed. A zone controller failure is detected by determining that every site in the dynamic site list is in Site Trunking. Currently, this condition must be detected for at lea

  • E.F. Johnson Company 5100 ES, ES Series Models II/III Portable Radio Operating Manual 7-7 Multi-Net Features 7.6 Emergency If programmed, the Emergency option button or menu parameter can be used to select and/or place a high priority call. Any option button can be programmed as an emergency button although the orange button on the top panel is normally used. When the emergency button is pressed with a Multi-Net channel selected, the emergency mode is indicated by “EMERGNCY” in the display. The transceiver then selects the emergency zone/channel as described in the next section. Operation is then controlled by Manual/Aut

  • E.F. Johnson Company 5100 ES, 7-22 ES Series Models II/III Portable Radio Operating Manual Multi-Net Features Acceptable - The RSSI of a site must exceed this level for it to be considered as a candidate for a new site by the site search procedure. Good - Not currently used. Very Good - Not currently used. 7.13.5 Manual Site Search When a Site Search option button or menu parameter is programmed, the following functions can be selected. Highlight the desired function using the Up/Down buttons and then select it by pressing the F2 button. Site Display - Briefly p

  • E.F. Johnson Company 5100 ES, ES Series Models II/III Portable Radio Operating Manual 2-5 Controls and Display Antenna Connector - This is the connection point for the antenna. Make sure the antenna is tight before using the radio. Emergency Button- This button or some other option button can be programmed as an Emergency button to alert a dispatcher of an emergency condition. Refer to Sections 5.9 and 6.8 for more information. If not programmed as an Emergency button, this button can also be programmed for other functions. The user can set an external line by

  • E.F. Johnson Company 5100 ES, ES Series Models II/III Portable Radio Operating Manual 5-7 Conventional Mode Features 5.5 Penalty Timer A penalty timer may be programmed on conventional systems to prevent transmissions for the programmed time after the time-out timer disables the transmitter (see Section 4.6). The penalty timer can be programmed for the same times as the time-out timer, and timing starts when the PTT switch is released. If the PTT switch is pressed while the timer is running the timer stops, and continues when the

Related Products and Documents (Portable Radio):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Karcher CV 66/2 Instruction manual karcher/cv-66-2-2HB.pdf 24 Jun 2023 148
2 Sirius Satellite Radio Dock & Play PowerConnect Operation & user’s manual sirius-satellite-radio/dock-play-powerconnect-1AR.pdf 29 Jul 2023 78
3 BMW 325xi Owner's manual bmw/325xi-9V7.pdf 21 Oct 2023 166 3.31 Mb
4 SOLE LCB Owner's manual sole/lcb-FH7.pdf 14 Dec 2022 26 1.9 Mb
5 MotoSAT Nomad 2 Owner's manual motosat/nomad-2-5J3.pdf 17 Jan 2024 29
6 Dukane 104 Instruction manual dukane/104-3OD.pdf 24 Oct 2023 2 0.29 Mb

Similar Resources:

  • Kenwood

    TK-5210

    (2 pages)
    TK-5210/5310VHF/UHF FM & Project 25 Digital Portable Radios• Transceiver Password1• Date & 12/24 Hour Time Clock1• Windows®Programming & Tuning3• Windows®Firmware Uploading3• Self-Programming & Tuning1• Cloning1• Easy Option Port•Weather-Sealed Accessory Connector• MIL-STD-810 C/D/E/F• IP54/55 Water & Dust Protection …
  • Audiovox

    FR-214

    (12 pages)
    Released 9-11-98.Rev. A - Change Power station to charging stand pg. 3. 9-16-98Rev. B - Change battery type from ni-cad to rechargeable pg. 3,4 9-16-98Rev. C - Change Warranty and Customer Service telephone number 4-25-00Model FR-214Model FR-214Model FR-214Model FR-214Model FR-214OwnerOwnerOwnerOwnerOwner’s Man’s Man’s Man’s Man’s Manualualualual …
  • Ericsson

    M-PA

    (16 pages)
    TABLE OF CONTENTSREAR COVER ASSEMBLY .......................... LBI-38383FRONT COVER ASSEMBLY (LATER)LESS CONTROL BOARD .......................... LBI-38834CONTROL BOARD (LATER) ........................ LBI-38828UHF SERVICE SECTION .......................... LBI-38386Maintenance ManualLBI-38379CM-PA403-512 MHzPORTABLE FM RADIOERICSSONZ …
  • Icom

    iC-F3033S

    (32 pages)
    INSTRUCTION MANUALThis device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference.iF3033SiF3031SVHF TRANSCEIVERSiF3036SiF4033SiF4031SUHF TRANSCEIVERSiF4036SThe photo shows the VHF transceiver …
  • Vertex Standard

    VX-820 series

    (42 pages)
    1ContentsSpecifications ...................................................................................................................................................... 2Exploded View & Miscellaneous Parts .......................................................................................................... 3Block Diagram ...................... …
  • BT

    Twin Radio

    (37 pages)
    BT Freelance XD ~ 3rd Edition ~ 2nd August ’02 ~ 4832UserGuideBT Freelance XD 100 / 100 TwinDigital Cordless TelephoneThis product is not DECTGAP compatible. It cannotbe registered to any otherDECT GAP telephone and it is not possible to registeradditional handsets.This equipment is not designed for making emergency telephone callswhen the power fails. Alt …

Comments, Questions and Opinions: