  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 3 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 WARNING Securely fasten the enclosure to the mounting location, using 3/8-inch diameter steel mounting bolts and washers, or washer head bolts. WARNING Do not disconnect equipment while energized. Insure proper grounding to protective earthing. WARNING The front cover is not hinged to the rear enclosure. When the cover bolts are removed, the co

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 12 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Attach the Front Cover After all adjustments have been completed, inspect and clean the machined flange joint surfaces of both the cover and box. Surfaces must be smooth, free of nicks, scratches dirt or any foreign particle build-up that would prevent a proper seal. Surfaces must seat fully against each other to provide a proper explosion-proof joint. Clean surfaces by wiping with a clean lint-free cloth. Apply a light coat of Killark “LUBG” lubricant to flange

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 11 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Table 3. Recommended Cabling Cable Use Size LAN Cat5 or Cat5e UTP cable with an RJ45 connector Power Two-conductor, No. 22 AWG is typical Inputs Two-conductor, No. 22 AWG is typical Output contacts Two or three-conductor, No. 18 AWG is typical Speaker Two or three-conductor, No. 18 AWG is typical Status Indication Power The Power LED located on the VoIP PCBA illuminates when power is applied to the telephone. Heartbeat The Heartbeat LED located on the VoIP PCBA will flash once

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 19 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Specifications Power ............................... Power-over-Ethernet, 802.3af compliant (via RJ45) Power Mode A, Class 0, or External power supply: 48 V dc, 200 mA A separate, isolated supply must be provided for each telephone. Network ........................................................................... 10/100 BaseT Ethernet RJ45, Cat5 or Cat5e UTP Static IP provisioning or DHCP

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 20 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Environmental Operating temperature .......................................................................... −4º F to +140º F (−20º C to +60º C) Humidity ...................................................................................................................... 95% non-condensing Mechanical Enclosure .............................................................................. Cast aluminum with aluminized lacquer paint Hands

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 4 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Mounting NOTE: The mounting surface must be able to support the weight of the telephone, which is 28 lbs. The enclosure must be securely fastened with 3/8-inch diameter steel mounting bolts located on all four mounting feet. Stainless steel hardware is recommended in outdoor applications. Refer to Figure 2. The suggested mounting height is 48 inches to the bottom o

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 14 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 A CD containing all help files and the configuration file tool is available from GAI-Tronics on request. Figure 12. Alternative Configuration Methods There are three methods for configuring GAI-Tronics Handset VoIP telephones:  Web pages  Configuration file  Command Line interface (CLI) Web pages (held within the telephone) can be accessed over the network using a browser such as Internet Explorer™, to view and change settings within a single unit. Configuration files

  • GAI-Tronics 352-701, (Rev. 10/06) Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document. If (a) Seller’s goods prove to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above, Buyer may return such good

  • Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 10 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Table 1. Auxiliary Inputs – P12 Pin Label Function 1 IN4 Input 4 2 COM Common 3 IN3 Input 3 4 COM Common 5 IN2 Input 2 6 COM Common 7 IN1 Input 1 8 COM Common Outputs Two outputs have been

  • Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 6 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 For the Model 352-703 Division 1 VoIP Telephone with the headset option, the cradle and handset are replaced with a removable headset and headset activation bracket. Figure 5. Model 352-703 Division 1 VoIP Tele

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 7 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Internal All standard components are mounted to the rear of the front cover. See Figure 6 for the parts layout. Figure 6. Model 352-70x Division 1 VoIP Telephone - Internal View

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 15 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Operation Model 352-701 Handset Operation 1. Lift the handset to place a call. 2. The handset receiver volume control located on the front cover keypad, can be adjusted to the desired level by pressing the volume control push button. 3. Dial the desired number. 4. After completion of the call, place the handset on-hook. Figu

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 13 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Programming Refer to Pub. 42004-396, VoIP Telephone Configuration Guide for detailed programming and configuration instructions. Quick Start Guide For easier set up, configure the software prior to installing the telephone in a hazardous environment. The general sequence for set up and use is as follows: Stage of Process Comments 1. Initial network configuration Essential: The telephone must be set up for the netw

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 2 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Tips for VoIP Subscribers If you have or are thinking of subscribing to an interconnected VoIP service, you should:  Provide your accurate physical address to your interconnected VoIP service provider to ensure that emergency services can quickly be dispatched to your location.  Be familiar with your VoIP service provider’s procedures for updating your address, and prompt

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 18 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Troubleshooting Table 4. Troubleshooting Chart Problem Possible Solution Low volume in handset or headset Increase the volume setting using the Volume Adjust button on the front panel. N OTE: There is no external speaker adjustment. High volume in handset or headset Decrease the volume setting using the Volume Adjust button on the front panel. N OTE: There is no external speaker adjustment. Front panel push buttons are not operational Verify the push buttons are

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 9 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Figure 8. Input Cable Connections at P12 Figure 9. Output Cable Connections at P10 Figure 10. Power Power-Over-Ethernet (POE) Connect power to the system as indicated in your POE equipment manual. (Power Mode A, Class 0) Local Power When POE is not available, this telephone can operate from a local 48 V dc power source. A removable terminal block, P5, has been provi

  • Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 16 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Model 352-703 Headset Operation 1. To connect the headset, plug it into the flexible plug on the front of the telephone by removing the sealing cap from the receptacle, aligning the connector pins, a

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 8 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 Wiring WARNING The front cover is not hinged to the rear enclosure. When the cover bolts are removed, the cover must be adequately supported. 1. While supporting the front cover, remove the ten cover bolts on the enclosure flange. Pull the front cover far enough away to expose the internal connections. Place the front cover aside. 2. Plug the incoming Cat5 data line to the network

  • GAI-Tronics 352-701, Pub. 42004-456B Model 352-701 and 352-703 Division 1 VoIP Telephones Page 17 of 20 e:\standard ioms - current release\42004 instr. manuals\42004-456b.doc 01/14 5. Flip the headset activation bracket to its vertical preset position to hang up. If applicable, place the headset on the bracket after the completion of the call. Otherwise, disconnect the flexible receptacle and plug by unscrewing the two ends, and pulling them apart. When disconnected, reattach the sealing cap to the end of the receptacle. Figure 15. Maintenance Service If your telephone requires depot service, contact your Reg

Related Products and Documents (IP Phone):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Rocstor ROCSERVE 4RTe Installation and configuration manual rocstor/rocserve-4rte-QPK.pdf 22 Jul 2023 126 9.67 Mb
2 Hoover WH10600 Owner's manual hoover/wh10600-2KY.pdf 08 Dec 2022 27 3.09 Mb
3 Epson 785EPX - Stylus Photo Color Inkjet Printer Specification sheet epson/785epx-stylus-photo-color-inkjet-printer-94V.pdf 09 Feb 2024 1 0.09 Mb
4 Sharp XE-A40S Service manual sharp/xe-a40s-K1F.pdf 27 Aug 2022 28 2.69 Mb
5 Zanussi T533 Instruction book zanussi/t533-3AA.pdf 18 Aug 2023 8 0.21 Mb
6 ZyXEL Communications P-2812HNUL-F1 Quick start manual zyxel-communications/p-2812hnul-f1-2CS.pdf 14 Aug 2023 12 0.26 Mb

Similar Resources:

  • Cisco

    6851

    (2 pages)
    Cisco 6851 Multiplatform IP Phone Quick Start Guide 1 | Page Place a Call Enter a number and pick up the handset. Your Phone Answer a Call Press the flashing red line button to answer the non-shared line. If the line is shared, you must select “answer” softkey. Put a Call on Hold 1. Press Hold . 2. To resume a call from hold, press Hold again. …
  • Aastra

    VentureIP 480i

    (1 pages)
    www.aastratelecom.comAastra Announces Software Release 1.4.1 for our SIP IP Phones Aastra Telecom is pleased to announce the availability of a new software update for our Enterprise IP portfolio of SIP telephones, including Models 480i, 9133i, 9112i, and 480i CT.Release 1.4.1 delivers new features and enhancements including:Local redundancy support enabling …
  • Cisco

    SPA232D

    (16 pages)
    Quick Start GuideCisco SPA232D Mobility Enhanced ATAPackage Contents• Analog Telephone Adapter• Ethernet Cable• Phone Cable • Power Adapter • Quick Start Guide• Product CD-ROM …
  • Cisco

    MCS 7800 Series

    (228 pages)
    Cisco IP Phone 7800 Series Administration Guide for Cisco UnifiedCommunications ManagerFirst Published: 2015-05-05Last Modified: 2019-02-04Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 408 527-0883 …
  • Aastra

    Aastra 600 c/d series

    (32 pages)
    Aastra Business Communication SystemsAastra 600c/dSafety InformationSupported phones:Aastra 610dAastra 620dAastra 630dAastra 650cAastra 612dAastra 622dAastra 632deud-1144_xx / 1.4 - © 05.2011 …
  • Polycom

    SoundPoint MAXCS 7.5

    (6 pages)
    MAXCS 7.5 Polycom SoundPoint User Guide Page 1 MAXCS 7.5 Polycom® SoundPoint Phone User Guide This guide shows how to use the following Polycom® SoundPoint model phones with MAXCS Release 7.5 client applications. • IP321 • IP331 • IP550* • IP650* • IP670* *These models support advanced features via the MAXCS Polycom Advanced Features …

Comments, Questions and Opinions: