Manualios.com

Cadet 40 - 120 User's Information Manual

Cadet 40 - 120 Manual Online:

4.05, 527 votes
Cadet 40 - 120 User Manual
Cadet 40 - 120 User Guide
Cadet 40 - 120 Online Manual

Text of Cadet 40 - 120 User Guide:

  • Cadet 40 - 120, CAD-USER Rev A User’s Information Manual Models: 40 - 120 If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance MUST NOT be installed in any location where gasoline or flammable vapors are likely to be present. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a near by phone. Follow the gas supplier’s instructi

  • Cadet 40 - 120, 2 Hazard definitions The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product.  DANGER  WARNING  CAUTION CAUTION NOTICE DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation which, if not avoided, may res

  • Cadet 40 - 120, User’s Information Manual Please read before proceeding The Cadet Heating Boiler Installation and Service Manual is for use only by a qualified heating installer/service technician. Refer only to this User’s Information Manual for your reference. Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury (exposure to hazardous materials) or loss of life. Installation and service must be performed by a qualified installer, service agency or

  • User’s Information Manual 1 Prevent combustion air contamination 4 If the boiler combustion air inlet is located in a laundry room or pool facility, for example, these areas will always contain hazardous contaminants. To prevent the potential of severe personal injury or death, check for areas and products listed in Table 1A before installing the boiler or air inle

  • Cadet 40 - 120, User’s Information Manual 2 Maintenance schedule 5 Service technician (see the Cadet Installation & Service Manual) General: • Reported problems • Inspect interior; clean and vacuum if necessary • Clean condensate trap • Check for leaks (water, gas, flue, condensate) • Verify flue and air lines in good condition and sealed tight • Check system water pressure/system piping/expansion tank • Check control settings • Check ignition and flame sense electrodes (sand off any deposits; clean and reposition) • Wiring and connections

  • Cadet 40 - 120, 2 Maintenance schedule 6 Maintenance procedures Boiler must be serviced and maintained  WARNING The boiler must be inspected and started annually at the beginning of the heating season by a qualified service technician. In addition, the maintenance and care of the boiler designated on page 5 of this manual and explained on pages 6 through 8 must be performed to assure maximum boiler efficiency and reliability. Failure to service and maintain the boiler and system could result in equipment failure, causing

  • Cadet 40 - 120, 2 Maintenance schedule (continued) 7 Clean/Inspect Trap Assembly Remove the clean out cap on the bottom of the trap. Let the condensate and any debris drain out.  WARNING Figure 2-1 Condensate Trap Condensate disposal 1. This boiler is a high efficiency appliance that produces condensate. 2. The bottom of the boiler has a 3/4 inch pipe for connection of a 3/4 inch PVC pipe (FIG. 2-2). 3. Slope condensate tubing down and away from the boiler into a drain or condensate neutralizing filter. Condensate from the Cadet boiler will be slightly acidic (typically with a pH from 3 to 5). Install a neutralizing filter if required by local codes. A Neutralize

  • 2 Maintenance schedule 8  WARNING Have leaks fixed at once by a qualified service technician. Failure to comply could result in severe personal injury, death, or substantial property damage. 2. Read the boiler pressure/temperature gauge to make sure the system is pressurized. Lift the relief valve top lever slightly, allowing water to relieve through the valve and discharge

  • Cadet 40 - 120, 10 4 Operating information Cadet heating boiler control module MODULATION INCREMENTS (20% INCREMENTS) OF FIRING CONTROL DOWN BUTTON “RESET” LOCKOUT OR “SET” FOR CHANGING SETTINGS ENTER BUTTON RESET BUTTON SERVICE MODE FREEZE PROTECTION DOMESTIC HOT WATER PUMP DOMESTIC HOT WATER DEMAND SPACE HEAT DEMAND BOILER PUMP DISPLAY SCREEN UP BUTTON Figure 4-1 Control Panel Indicators Use the control panel (FIG. 4-1) to set temperatures, operating conditions, and monitor boiler operation. User’s Information Manual

  • Cadet 40 - 120, Installation & Service Manual 4 Operating information (continued) User programming sequence Aer Timeout Base State Screen Show Status and Temperatures (Default is Outlet Temperature) ON/OFF Press UP for 5 seconds to either Turn On or Off Unit Press ENTER for 5 seconds to Enter User Parameters Set Degrees in °C or °F by Pressing UP or DOWN Set Space Heat Mode Setpoint by Pressing UP or DOWN (Based on System Sensor if Installed, Otherwise Outlet Sensor) Press ENTER Save New User Parameters to Control Press ENTER After Timeout Set DHW Mode Setpoint by Pressing UP or DOWN (Based on Tank/DHW Sensor if Insta

  • 12 Viewable and changeable control parameters Temperature Units (°C/°F) The control can be configured to display temperature in either °C or °F. This parameter can be changed by accessing parameter u01. Set SH Temperature The Space Heat Demand Temperature can be adjusted UP or DOWN by accessing parameter u02. Temperature range is 32°F to parameter P90. Set tank DHW

  • Cadet 40 - 120, 13 User’s Information Manual 4 Operating information (continued) E00 Invalid Lockout E01 Memory Lockout E02 Fan Speed Fault E04 Flow Switch Fault E05 Flame Out of Sequence E06 Auto Reset Hi Limit E07 Air Pressure Switch E08 Heat Exchanger Limit E09 Auxiliary Limit E11 No Flame Running E12 No Flame Ignition E13 Flue Temperature Limit E15 Manual Reset Hi Limit E18 Outlet Sensor Differential E19 Flue Sensor Open/Short E21 Outlet Sensor Open/Short E22 Inlet Sensor Open E23 Inlet Sensor Short b01 Setpoint Met b02 Anticycling b03 Outlet Tempera

More Instructions:

DOWNLOAD

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Alpha LW A Series Operating manual alpha/lw-a-series-13U.pdf 28 Jun 2022 32
2 GE GTDP180ED4WW Installation instructions manual ge/gtdp180ed4ww-CE8.pdf 12 Mar 2023 8
3 Samsung P1043 Owner's instructions manual samsung/p1043-LP6.pdf 22 Dec 2022 12 0.27 Mb
4 Chauvet COLORpalette Operation & user’s manual chauvet/colorpalette-XUN.pdf 09 Sep 2022 20
5 Ariston ACO 35 MFFI Operation & user’s manual ariston/aco-35-mffi-41U.pdf 23 Jul 2023 12 0.78 Mb
6 Venmar C180 Installation instructions manual venmar/c180-J8L.pdf 27 Sep 2022 48

Similar Resources:

  • Hoval

    TopGas Cascade 60

    (51 pages)
    Technical Information and Assembly ManualOutput range 60 to 720 kW4215256-00 - 11/16 Subject to modificationTopGas Cascade Condensing Gas Boilers …
  • Weil-McLain

    LGB LGB-23

    (12 pages)
    Part Number 550-141-916/0304ContentsI. Installation ..................... 2II. Gas piping ...................... 4III. Wiring ............................ 5Sequence of operation ....... 5Wiring procedure ............... 8IV.Operating instructions . 9V. Verification testing ..... 10VI.Parts list ....................... 11These terms are used throughout thisma …
  • Westinghouse

    WBR 080

    (94 pages)
    WHL-016 REV. 12.18.14 Gas Fired Boiler Residential and Commercial Models INSTALLATION START-UP MAINTENANCE PARTS WBR Models* 055 / 080 / 110 / 155 / 199 / 285 / 399 Model Names with “LP” denote propane gas, “N” denote natural gas, and “PU” denote included pump Heat Exchanger Bears the ASME “H …
  • IBC

    DC Series

    (24 pages)
    USER’S INFORMATION MANUALwww.ibcboiler.comDC Series Combi BoilersHC Series Boilers(Natural Gas or Propane)WARNING: If the information in this manual is not followed exactly, a re or explosion may result causing property damage, personal injury, or loss of life.Do not store or use gasoline or other ammable vapours and liquids or other combustible mate …
  • IDEAL

    mini HE C32

    (4 pages)
    users guidemini HEWhen replacing any part of this appliance, use only s pare parts that you can beassured conform to safety and performance specification that we require. Do not usereconditioned or copy parts that have not been clearly authorised by Ideal BoilersYour Ideal users g uideFor installation and servicing guide seereverse of bookC24,C28,C32 …
  • Powermatic

    PON Series

    (23 pages)
    PON Series Cast Iron BoilersInstallation Operation & Maintenance ManualInstallation,Operation & Maintenance Manual,pCast Iron SectionsCast Iron SectionsTriple Pass DesignTriple Pass Design163 kW 355 kW163 kW - 355 kWN0-ON010-/ 20.02 /EV.0RE …