  • Aarow Nouveau 7, MULTIFUEL GRATE GRATE The grates in the Nouveau Multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb". All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "H" sitting on the high sections of the comb, and the ends marked "L" sitting on the low sections. ASSEMBLING THE GRATE To assemble the grate, fit bars to low sections of the comb first, inserting end marked "H" into rear channel with groove on underside of bar located on upstand tab, and then lowering end marked "L" onto the low sec

  • Aarow Nouveau 7, DOOR ADJUSTMENT The catch can be adjusted by sharply tapping the catch on the inside of the door. Nouveau 7 Multifuel Stoves are fitted with bolt on hinges. These should not normally require adjustment. However if the seal of the alignment seal of the doors does require adjustment the procedure is as follows: •It is recommended to work on one door at a time, slacken, 2 No. bolts move the door up or down. •Tighten the bolts whilst holding the door in the correct position. (See Fig. 6) Fig. 6 FITTING THE FEET The Nouveau 7 multifuel sto

  • Aarow Nouveau 7, 22 Nouveau 7 Multifuel Stoves INSTALLATION PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES TYPICAL METAL INSULATED CHIMNEY SYSTEM TO BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1-4 A is minimum clearance for non-insulated flue = 1.5 x D to a non-combustible surface/material or 3 x D to combustible surface/material

  • Aarow Nouveau 7, Nouveau 7 Multifuel Stoves 19 INSTALLATION FITTING THE FLUE OUTLET AND HOT PLATE The flue outlet spigot is found inside the appliance. The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet). Smear a very thin layer of fire cement on the faces of the flue outlet and the blanking plate. Fit the outlet to the appliance in the desired position . Lock into place by rotating anti-clockwise and tighten by tapping with a block of wood and mallet from the inside of the applian

  • Aarow Nouveau 7, 16 Nouveau 7 Multifuel Stoves INSTALLATION GENERAL PRECAUTIONS Note - All installations must conform to the appropriate building regulations. The Building Regulations for England and Wales 2000 ref Approved Document J 2002 edition (issued by the DTLR). The Building Standards (Scotland) (Consolidation) Regulations. Detailed recommendations for installation of appliances, chimneys and flues are outlined in the current issue of the following British Standards:- BS6461, BS8303 and BS4543. Any Manufacturer's Instructions must not be taken as overriding statutory requirements. During i

  • Aarow Nouveau 7, 24 Nouveau 7 Multifuel Stoves INSTALLATION Primary flow and return pipes should be 28mm diameter. The cylinder should be installed at a higher level than the appliance, and as close to it as possible (the higher the cylinder the faster the circulation). The flow and return pipes should not be longer than 20ft each. Pipe runs should rise continually from the boiler to the cylinder. A radiator of approximately 25 sq.ft. should be connected into the primary circuit, if installed in the bathroom it provides a means of drying towels in the summer. Safety Vent Circuit This circuit consists of a cold feed pipe, expansion pipe, and expansion tank. The possibility that water may boil can

  • Nouveau 7 Multifuel Stoves 25 INSTALLATION CHECKLIST Hearths, Fireplaces, Flues and chimneys This checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the requirements of The Building Regulations 2000 Approved Document J 2002. 1. Building address, where work has been carried out..............................

  • Aarow Nouveau 7, Due to the gradual introduction of European Chimney Standards chimneys will be specified according to their performance designation as defined in BS EN 1443 that covers the General Requirements for chimneys. The minimum performance designation required for use with solid fuel burning stoves is T450 N2 S D3. The flue and chimney installation must be carefully checked by a competent person before fitting the stove to ensure it is suitable and will work safely. If the chimney is old (i.e. built of brick or stone without a liner) or being opened up for reuse additional checks and smoke testing as described in Appendix E of the Approved Document J 2002 Edition sho

  • Aarow Nouveau 7, INTRODUCTION Page Safety Notices 5 The Principle of the Fire 5 Check List 6 Technical Data 7 OPERATING INSTRUCTIONS Firebox Linings and Throat Plate Removal 8 Airwash System 8-9 Interlock 9 Multi-Purpose Operating Tool 9 Door Trim 9 Fire Door Glass 9-10 Door Adjustment 10 Fuels 11 Lighting The Fire 11 Over-Firing 13 Cleaning & Annual Maintenance 13/14 Accessories 15 INSTALLATION Page General Precautions 16 Handling 16 Hearth 16 Combustible Materials 16 Firebox Liner Panels 17 Throat Plate Inspection 17 Assembling the Multifuel Grate 18 Flues & Chimneys 19-22 Add In Boilers/Water C

  • Aarow Nouveau 7, Inside the appliance you should find the following: 6 Nouveau 7 Multifuel Stoves CHECK LIST Part Description & Visual Aid (not to scale) Nouveau 7 Multifuel 1. Grate Bars 5 2. Fuel Retainers 2 3. Throat Plate 1 4. Flue Spigot 1(5”) 5. Hot Plate 1(5”) 6. Ashpan 1 7. Operating Tool 1 8. Rear Liners 2 9. Side Liners 2 10. Cast Fire Door Handle 2 11. Feet & Fixings 4 12. Instructions 1

  • Guarantee Once again we would like to thank you for buying a Nouveau fire. When you buy an Aarrow Fire, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance for as long as you want. The Nouveau 7 Multifuel Stove comes with a Lifetime Guarantee against splitting or cracking of the main body. Th

  • Aarow Nouveau 7, ASH REMOVAL The ash pan should be emptied at least twice a day or when the level of ash reaches the top of the ash pan. On no account should the ash be allowed to build up to touch the grate as this will greatly shorten its life. DE - ASHING It is necessary to maintain an ash layer on the upper surface of the grate bars, in order to protect them so de-ashing should cease as soon as the first red embers drop into the ash pan. Further de-ashing will cause heat build-up under the grate, which will considerably shorten its life. This oper

  • Aarow Nouveau 7, Nouveau 7 Multifuel Stoves 5 INTRODUCTION SAFETY A fireguard conforming to BS 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to BS 3248 should be fitted. Do not use aerosol sprays or any other flame near the appliance under fire. Do not fit an extractor fan in the same room as the appliance. Fire cement is caustic, hand and eye protection should always be worn, prolonged contact with the skin should be avoided. Arada Ltd will not be responsible for any conse- quential or incidental loss or injury h

  • Aarow Nouveau 7, Nouveau 7 Multifuel Stoves 23 INSTALLATION ADD IN BOILERS Nouveau 7 multifuel stoves offer the option of a cantilever boiler or a slab boiler, which occupies the position of the rear firebox liner panels. Fitting: •Remove the fuel retainers, rear firebox liner panels and throat plate. •Knock out the blanking discs in the back plate corresponding to the terminals on the boiler. •Introduce the boiler to the appliance through the main fire door and locate the terminal pipes through the back plate holes and seal around boiler terminals with fire cement. •Engage locking nuts to the thread of the terminals and tighten to secure the boiler in pos

  • ENSURE THAT YOU HAVE READ & UNDERSTOOD THESE INSTRUCTIONS BEFORE LIGHTING THE FIRE. ALWAYS WEAR SUITABLE PROTECTIVE FIRE GLOVES WHEN REFUELLING YOUR STOVE. SOLID FUEL BURNING •Set the grate to ‘coal’ position. •Ensure that the ash pan is in position and the fire doors are closed. •Set the air wash to one quarter open position. •Set the primary inlet to

  • Aarow Nouveau 7, INTERLOCK SYSTEM Nouveau fires are fitted with an "interlock" system. A situation where the fire door is closed and the ash door is open may lead to serious over firing which could damage the appliance. Correct use of the doors and interlock system will ensure that this does not happen. Operation is as follows: A pivoted lug prevents closure of the fire door, unless the ash door has been shut first. When the fire door is shut the ash door knob can be turned anti-clockwise by up to 95 degrees creating a variable gap between the top of the ash door and the bod

  • Aarow Nouveau 7, Nouveau 7 Multifuel Stoves 27 PARTS LIST 8. Liner Set AFS1016 AFS1060 AFS1061 AFS1009 AFS1010 AFS1035 AFS1077 9. Side Liner 10. Back Liner Set 11. Glass Replacement Kit Complete with Gasket 12. Glass Clips 13. Hinge kit Comprises 2 Hinges & 4 Fixings Per Set. 14. Airwash Part Description Visual Aid (not to scale) Nouveau 7 Part No. *Pictures shown above may not represent actual parts and are as a guide only

  • Aarow Nouveau 7, FIREBOX LININGS & THROAT PLATE The Nouveau 7 Multifuel stoves firebox has reflective liners to the sides and rear) and a specially shaped throat plate which sits on the liners. If these are not in place please refer to page 17 to install these. MULTIFUEL GRATE The Aarrow Multifuel grate comprises of a series of reciprocating cast iron bars seated on a pivoted "comb". These should come fitted in your stove, if not please refer to page 18 for fitting and operation and also operating instructions on fuels for correct settings of the grate. AIR INLET CONTROLS Nouveau mult

  • Aarow Nouveau 7, Nouveau 7 Multifuel Stoves 7 TECHNICAL DATA Room Min/Max Room Heater Only Output (kW) 1.5 - 7 TECHNICAL DATA Nouveau 7 Multifuel Room Heater with Domestic Hot Water with add in boiler type 1 2 Max Output to Room (kW) Max Output to Water (kW) 4.4 3 2.6 4 Height (mm) 620 Width (mm) 476 Depth (mm) 365 Height to Centre of Rear Flue 508 Depth from Back to Centre of Flue 108 Flue Diameter 127 (5”) Weight Packed (Kg) 73 Kg

  • Nouveau 7 Multifuel Stoves 15 ACCESSORIES ACCESSORIES PAINT Matching aerosol paint to tone in any connecting flues, pipes or surrounding metalwork. ADD IN BOILERS For further information on add in boilers see page 23. INTERCHANGEABLE CANOPIES •To fit the interchangeable canopy (Fig. 7): Remove the front clamps. •Tilt the canopy as shown in stage 1. •Engage the rear clips and pull fully fo

  • Aarow Nouveau 7, ANNUAL MAINTENANCE It is important that your fire is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following. Remove the firebricks lining and throat plate, inspect all gaskets on doors, glass etc., and re-order any items that may need replacing, from your Aarrow dealer. With a wire brush clean inside the appliance paying particular attention to the small inlet holes of the air wash on the inside, above the fire door and to the door. Sweep the chimney and confirm that it is sound. Examine all

  • Aarow Nouveau 7, Nouveau 7 Multifuel Stoves 17 INSTALLATION FIREBOX LINER PANELS The Nouveau 7 Multifuel stoves use firebox liner panels to the base, sides and back. The Nouveau 7 Multifuel stoves have reflective liners to the sides and back. The throat plate sits on top of the side and rear panels. These should come fitted to your fire, if however they are not proceed as follows to fit them. •Remove the front fuel bars or multifuel grate. •Set the small liner into the back of the fire. •Insert side liner panels. •Fit the throat plate with the single bend and two cut outs to the front facing up. The projecting lugs sit on top of the side liners. The long centre tab on the ba

Related Products and Documents (Cooktop):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 AVer AVerVision F70W Operation & user’s manual aver/avervision-f70w-PH8.pdf 31 Oct 2022 61
2 Sears 917.252641 Owner's manual sears/917-252641-315.pdf 20 Aug 2023 22 2.67 Mb
3 Heat Surge Mini Glo Product manual heat-surge/mini-glo-65S.pdf 30 Oct 2023 12
4 Yamaha NS-6490 Owner's manual yamaha/ns-6490-J12.pdf 30 Jan 2024 3 0.14 Mb
5 Makita AF505 Instruction manual makita/af505-Z2A.pdf 18 Jul 2022 68
6 Vertex Standard VXR-7000 Service manual vertex-standard/vxr-7000-6FM.pdf 16 Mar 2023 134

Similar Resources:

  • Faber

    GALILEO BK GLASS NG A830

    (24 pages)
    INSTALLATION MANUALINSTALLATIONSANLEITUNGMANUEL D’INSTALLATIONINSTALLATIE-INSTRUCTIESMANUAL DE INSTALACIÓNLIVRO DE INSTRUÇÕES PARA INSTALAÇÃOLIBRETTO DI INSTALLAZIONEINSTALLATIONSHANDBOKINSTALLASJONSVEILEDNINGASENNUSOHJEETINSTALLATIONSVEJLEDNINGPAIGALDUSJUHENDÜZEMBE HELYEZÉSI ÚTMUTATÓMANUAL DE INSTALAREINSTRUKCJA INSTALACJINAVODILO ZA NAMESTITEVUD …
  • Smeg

    A4-5

    (38 pages)
    Table of Contents 1. PRECAUTIONS FOR SAFETY AND USE ___________________________ 44 2. INSTALLING THE APPLIANCE ___________________________________ 46 3. ADAPTATION TO DIFFERENT TYPES OF GAS______________________ 50 4. FINAL OPERATIONS ___________________________________________ 52 5. DESCRIPTION OF CONTROLS___________________________________ 53 6. US …
  • Frigidaire

    FGFLMC55GCB

    (32 pages)
    idaire.comControls ....... 7Controls ............... 8Control Pad Features ..................... 9Setting Oven Controls ............ 10-21Bake-n-Warm TM Double Oven 22-24Self Cleaning ........................... 25-27Adjusting Oven Temperature ....... 27Care & Cleaning ..................... 28-30Before You CallSolutions to Common Problems ............... …
  • GE

    Profile JSP47WFWW

    (2 pages)
    TMTMJSP47BF/CF/WF – GE Profile™30" Slide-In Electric RangeDimensions (in inches)Note: Cabinets installed adjacent to slide-in electric ranges must have an adhesion spec of at least 194°F temperature rating.Note: All 30" Slide-In Ranges conform to U.L. requirements for 0" spacing from range toadjacent walls below countertop. To reduce poss …
  • Zanussi

    ZCM930X

    (32 pages)
    INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance. GB MIXED FUEL COOKER ZCM930X …
  • Whirlpool

    RF366PXY

    (32 pages)
    UseAhdCare A Note To You 2 Parts And Features Using Your Range Using The Setf- Cleaning Cycle 21 24 Or Service Warranty 29 32 1-800-253-1301 Call us with questions or comma u-its. SELF-CLEANING ELECTRIC RANGE MODEL RF366PXY …

Comments, Questions and Opinions: