Manualios.com

Eco Air ECO10P Installation And Operation Manual

  • ECO10P Air Conditioner
  • mairrJHUWQwp6
  • Installation And Operation Manual
  • PDF / Adobe Acrobat Reader
  • 19

Eco Air ECO10P Manual Online:

4.25, 2996 votes
Eco Air ECO10P User Manual
Eco Air ECO10P User Guide
Eco Air ECO10P Online Manual

Text of Eco Air ECO10P User Guide:

  • Eco Air ECO10P, Installation and Operation Manual Room Air Conditioners Portable Heat Pump Range ECO10P Register your air conditioner Model information can be found on the CE label. Please register your product online at www.ecoair.org. For your future convenience, record the model information below. ____________________________________ MODEL NUMBER ____________________________________ SERIAL NUMBER ____________________________________ PURCHASE DATE

  • Congratulations! You have purchased the very latest in room air conditioner technology. Your new EcoAir high efficiency room air conditioner will give you many years of dependable service. Many features have been built into your EcoAir air conditioner to assure quiet operation, the best circulation of cool, dry air, functional controls, and the most economical operation.

  • Eco Air ECO10P, BS Plug Wiring Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code: BLUE - NEUTRAL BROWN – LIVE GREEN AND YELLOW - EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: 1. The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK. 2. The BROWN wire is the LIVE and must be connected to

  • Eco Air ECO10P, SPECIFICATION Model no. ECO10P Cooling capacity 10528 BTU/hr 3084 watts Heating capacity 10000 BTU/hr 2930 watts Power/Ampere consumption for cooling 1050 W/ 4.7A Power/Ampere consumption for heating 940 W/ 5.0A Air volume (max. speed) 300m 3 /h Humidity removal capacity 24L/day Power supply 220-240V~. 50Hz Compressor rotary Noise Level 53 dB Refrigerant R410A (370g) Fan speed 2 Timer 1~12 hours Working temperature Cooling: 18 ~ 32 o C Heating: 7 ~ 25 o C Exhaust pipe Ø 120x1500mm Net Weight 25.5 kgs Gross Weight 28.0 kgs Net Dimension 305x752x383 mm (WxHxD) Gross Dimensio

  • BEFORE USE BEFORE USEBEFORE USE BEFORE USE GENERAL SAFETY GENERAL SAFETYGENERAL SAFETY GENERAL SAFETY • ONLY USE IN THE UPRIGHT POSITION ON A FLAT LEVEL SURFACE AND AT LEAST 50cm FROM ANY OBJECTS (Fig 1&4). • DO NOT PLACE OBJECTS ON THE UNIT OR RESTRICT AIR INLET/OUTLET (FIG. 2). • CLOSELY SUPERVISE ANY CHILDREN AND PETS WHEN UNIT IS

  • Eco Air ECO10P, F FF FOR MAXIMUM EFFICENCY OR MAXIMUM EFFICENCYOR MAXIMUM EFFICENCY OR MAXIMUM EFFICENCY • Do not exceed the recommended room size. • Take into account the number of people or equipment used in the room as these produce heat and will reduce the cooling effectiveness. • Avoid opening doors frequently. • Keep curtains or blinds closed during the warmest part of the day. • Keep filters clean. • Once room has reached the desired conditions, reduce temperature and ventilation

  • PRODUCT DESCRIPTION PRODUCT DESCRIPTIONPRODUCT DESCRIPTION PRODUCT DESCRIPTION Front Back FIG.5 FIG.6 1. Control panel 2. Air vent (air outlet) 3. Caster 4. Air inlet 5. Carrying handle 6. Air inlet 7. Air filter 8. Cord hanger 9. Compartment for cord storage 10. Air filter 11. Air inlet 12. Water bung 13. Air outlet Accessor

  • Eco Air ECO10P, INSTALLATION Installation of the exhaust pipe The unit is a portable air conditioner that may be moved from room to room. 1. Using the foam strips. FIG.8 • Offer foam strips to the window gap and cut to size if necessary. • Feed exhaust hose through the foam strip and insert strip into window gaps as shown and slide window across so that foam is held securely. This technique may also be used for sash windows. Note: Take care to maintain protection against intruders. 2. Using the adaptor. FIG.9 FIG.10 • Cut a 130mm diameter hole in the wall or window. • Feed exhaust hose through the

  • Eco Air ECO10P, MOUNTING MOUNTING MOUNTING MOUNTING OF OF OF OF THE EXHAUST PIPE THE EXHAUST PIPETHE EXHAUST PIPE THE EXHAUST PIPE • Use only the hose provided and clip exhaust hose to the back of the air conditioner. • Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down. Fig 11 & 12 show correct position. • The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible. - 7 - FIG.11 FIG.12 FIG.13

  • Eco Air ECO10P, INSTALLATION OF CARBON FILTER FIG.15 1. Remove the filter frame from the unit. 2. Remove the filter fixer from the filter frame. 3. Remove the active carbon filter from its plastic bag. 4. Attach the active carbon filter to the filter frame. 5. Attach the filter fixer to the filter frame (the active carbon filter should be hold between the filter frames and filter fixer firmly). 6. Insert the filter set (filter frame + active carbon filter + filter fixer) into the back of the unit. - 8 -

  • Eco Air ECO10P, OPERATION OF CONTROL PANEL Control panel FIG.16 1. Mode (function) option button 2. Timer button 3. 'Temperature up' button 4. 'Temperature down' button 5. Speed (ventilation)button 6. ON/OFF (power) button 7. Automatic mode operation indicator 8. Cooling mode operation indicator 9. Fan mode operation indicator 10. Heating mode operation indicator ( only available for the mode with heating function, please refer to the actual unit you purchased) 11. Timer operation in

  • Eco Air ECO10P, Setting mode/function Press MODE button to select required working mode: automatic, cooling or fan. The indicator of your selected mode comes on. Setting temperature 1. Press 'Temperature up' or 'Temperature down' button to regulate the temperature you desired. 2. The display window will show the temperature you set as you press 'Temperature up' or 'Temperature down' button. Otherwise, it will always show the ambient temperature. 3. The pre-setting temperature of this machine is: 24 o C for cooling Setting ventilation speed 1. Press SPEED button to choose the ventilation speed you need, high or low. The indicator of

  • Eco Air ECO10P, Regulating air flow direction FIG.18 Turn the roller on the air vent to control the air flow direction left or right. FIG.19 The up & down air flow direction can be adjusted by moving the air vent directly. NOTICE ! 1. To prolong the compressor's life, after switching off the unit, please wait for a minimum of 3 minutes before switching on again. 2. The cooling system will switch off if the ambient temperature is lower than the set temperature. The ventilation, however, keeps working on the set level. If the ambient temperature rises above the selected level, the cooling will return to work. 3. The heating will switch

  • Eco Air ECO10P, DRAINAGE During the process of cooling, some water will be extracted from the air into the unit. Most of the water will be evaporated by the coil for maximum efficiency. However in very warm temperature or humid condition, excessive condensation may occur and will require water drainage when tank is full. If the tank is full, both of the compressor and motor will stop. The “water full” sign will light on, also the machine will beep as reminder. To make the cooling work again, please empty the water by one of the following ways: 1. Turn off the air conditioner and avoid moving it when full. 2. Position a container (a water tray for example) underne

  • Eco Air ECO10P, • The drain tube may be extended by adding an extension tube and using a suitable connector. FIG.22 Please note 1. The drain must be at or below the outlet level. 2. ‘Water Full’ indicator will not function in this mode of drainage. 3. If you want to extend the water tube, you can connect it with another tube (OD: 18mm) 4. When the room humidity is over 85%, it is necessary to use “continuous drainage” with the extended drain tube. Special caution for heating function! While u

  • Eco Air ECO10P, MAINTENANCE Always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner, clean regularly. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions. These all could possibly hurt the cabinet. Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water (no h

  • Eco Air ECO10P, FAULT CHECK LIST The air conditioner does not run  Is the air conditioner plugged in?  Is there a power failure?  Is the comp / ‘full water’ indicator flashing?  Is the room temperature below the set temperature? The machine seems to do little  Is there direct sunshine? (Please put down the curtain.)  Are too many windows or doors open?  Are there too many people in the room?  Is there something in the room producing lots of heat? The machine seems to do nothing.  Is the filter dusty, contamin

  • Eco Air ECO10P, EASY TO ORDER FORM FOR ACCESSORIES (Please complete in BLOCK CAPITALS in black ink) Full Name: Previous Invoice No.: (If available) Model No. Delivery Address: Telephone No.: Email Address: Signature DESCRIPTION PRODUCT CODE QTY UNIT PRICE TOTAL Filters Left Filter for Condenser 10P-114 £12.99 Rear Filter for Condenser 10P-115 £10.99 Filter for Evaporator & Fixer 10P-116&117 £14.99 Active Carbon Filter 10P-806 £12.99 Remote Control 10P-204 £19.99 Exhaust Accessories Exhaust Hose (1.5m) 10P-138 £24.99 Tube for continuous d

  • ONE (1) YEAR LIMITED WARRANTY SAVE THIS WARRANTY INFORMATION EcoAir guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded. This unit must be operated under conditions as recommended, at voltages

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lenovo ThinkCentre M57 Operation & user’s manual lenovo/thinkcentre-m57-681.pdf 09 Jan 2023 56
2 Action Star PK-2PA0-A-EL Operation & user’s manual action-star/pk-2pa0-a-el-GZ3.pdf 22 Dec 2023 7
3 Porter-Cable 3700L Instruction manual porter-cable/3700l-XG5.pdf 23 Mar 2023 23
4 Socket Mobile Power Pack Quick start manual socket/mobile-power-pack-8ET.pdf 08 Jun 2023 2 0.1 Mb
5 Yamaha RCX series Operation & user’s manual yamaha/rcx-series-6UX.pdf 12 Sep 2022 50 1.06 Mb
6 Logitech Harmony for Xbox 360 Operation & user’s manual logitech/harmony-for-xbox-360-TWS.pdf 03 Oct 2023 14

Similar Resources:

  • Panasonic

    CZ-01ESW11P

    (9 pages)
    OPERATION MANUALPACKAGED AIR CONDITIONERSCHEDULE TIMERMOdel No.CZ-01ESW11PENGLISHESPAÑOLITALIANONEDERLANDSDEUTSCHFRANÇAISBefore operating this set, please read these instructions completely …
  • Frigicoll

    MCA3U-12HRFNX-QRD0W

    (48 pages)
    IMPORTANT NOTE:Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.Please check the applicable models, technical data, F-GAS(if any) and manufacturer information from the “Owner's Manual - Product Fiche ” in the packaging of the outdoor unit. (European Union pro …
  • mundoclima

    WZ 25

    (33 pages)
    WZ 25Double Duct Air ConditionerCondizionatore monoblocco a doppio condottoINSTALLATION AND USER MANUALMANUALE D'USO E INSTALLAZIONEBEFORE INSTALLING AND USING THIS AIR CONDITIONER PLEASE READ ALLINSTRUCCIONS CAREFULLPRIMA DI INSTALLARE ED UTILIZZARE QUESTO CONDIZIONATORE LEGGETEATTENTAMENTE QUESTO MANUALE …
  • Delta Electronics

    HEC1500PB

    (21 pages)
    Specification and Manual Customer : Description : Air Conditioner for Equipment (Through Wall Mounting) Customer Part No. : Rev.: Delta Model No. : HEC1500PB Rev : Sample Date Code: Sample Issue Date : DELTA ELECTRONICS, INC. 252, SHANG YING ROAD, KUEI SAN T …
  • Bard

    Q-TEC Q A4D Series

    (97 pages)
    Literature Assembly 911-0838 Contains the following: 2100-034 (G) User Guide 2100-479 Leak Test Evacuation Charging 2100-752(C) Q24-42A4 Installation Instructions 2110-1568 (G) Replacement Parts Manual 7960-923 Dehum Supplemental Manual QA 7960-420 Warranty …
  • Carrier

    48TC

    (20 pages)
    48TCSingle Package RooftopGas Heating/Electric Cooling UnitS i z e s 0 4 --- 0 7 w i t h P u r o n r (R---410A) RefrigerantInstallation InstructionsNOTE: Read the entire instruction manual before startingthe installationTABLE OF CONTENTSSAFETY CONSIDERATIONS 1....................INSTALLATION 3...............................Step 1 -- Plan for Unit Location 3. …

Comments, Questions and Opinions: