  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 14 Setting the outlet water temperature When the required outlet water temperature is say 60°C, heat up the boiler to a temperature for instance 5°C higher than the required temperature of 60°C (measured on the thermometer on the boiler outlet pipe). Then turn the control knob to 65°C and check whether the chain is stretched and the regulating hatch completely shut. This position of the chain and regulating hatch is fine-adjusted by turning the control knob.Then let the regulation process work. When the water temperature drops, the regulating hatch will start opening by the tension applied by the regulator on the cha

  • INSTALLATION, OPERATION AND MAINTENANCE MANUAL 17 Boiler repairs The boiler may be repaired by an authorised service technician or organisation only. The user or owner may do only normal maintenance and simple replacements of some parts – e.g. sealing cords. Please note When repairing the boiler, original parts must always be used. Warranty and warranty conditions

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 5 Introduction 1. The boiler and all associated equipment must be installed and used in accordance with the installation design, all applicable legal regulations and technical standards and with the manufacturer’s instructions. The boiler may be used only for the purpose for which it is intended. 2. The boiler may be installed only in an environment which it is designed for.If the boiler is delivered to the client by the same person who installs it,

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 20 Boiler room disposition layout Fig. 22 illustrates minimum distances which must be kept in order to ensure safe operation of the boiler room and allow manipulations with the boiler, such as cleaning and stoking. The distance between the front of the boiler and the wall should be at least the boiler length L plus 500mm. Minimum distances between the boiler side and rear should be 800mm, with the distance of the rear also determined by the way the boiler is connected to the chimney. fig. 22 ■ Do not touch hot water connections or the flue outlet when the boiler is operatin

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 15 Important information ■ The boiler may only be operated by an adult familiar with these Operating Instructions. ■ Shut the boiler down every time there are any (even temporary) flammable or explosive fumes present on the premises from which combustion air is supplied to the boiler (e.g. From paint when painting, laying and spraying molten substances, from gas leakage, etc.). ■ It is forbidden to light the boiler with explosive substances. ■ It is forbidden to overheat the boiler. ■ At the end of the heating season the boiler, flue and flue adapter, must be thoroughly cleaned. Lubricate all hinges, t

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 8 Supply of secondary combustion air is controlled by an air rosette (Fig. 08), situated in the boiler’s stoking door, which has a direct effect on the level of emission. Hot water temperature can be checked on a thermometer (Fig. 09), which is situated in the front boiler cover above the stoking door. fig. 08 fig. 09 Air rosette Thermometer Temperature safety valve The Angus Max boilers can be equipped with a safety heat exchanger with thermal safety valve as an optional which ensures dissipation of excessive heat without additional device and supply of external energy in such a way that the maximum permis

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 6 Head losses fig. 04 Operating instructions Angus Max Series Boiler – General features ■ Angus Max series solid fuel fired boiler is designed for heating both residential and industrial buildings. ■ Besides professional installation, precondition for correct functioning of the boiler is the required chimney thrust and correct operation. ■ Angus Max series solid fuel fired boiler is designed for heating systems which are suitable for forced circulation systems only. ■ Angus Max series boilers are available in seven output series (determined by the number of segments 4, 5, 6, 7, 8, 9, 10) from 38 to 95

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 2 Boiler dimensions Boiler packaging dimensions Notice: Please obey to the meanings of the symbols on packaging for health care fig. 02 fig. 03 Series Angus Max-04 Angus Max-05 Angus Max-06 Angus Max-07 Angus Max-08 Angus Max-09 Angus Max-10 L (mm) 673 773 873 973 1073 1173 1273 Series Angus Max-04 Angus Max-05 Angus Max-06 Angus Max-07 Angus Max-08 Angus Max-09 Angus Max-10 L (mm) 730 830 930 1030 1130 1230 1330

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 12 fig. 15 fig. 16 1. Boiler 2. Safety Group (automatic air vent, pressure reducing valve and pressure gauge) 3. DHW Cylinder 4. CH Pump 5. Heating System 6. Four Way Mixing Valve 7. NRV 8. Expansion Vessel 9. Accumulator Tank 10. Three Way Valve 11. Valve

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 22 Spare parts list fig. 25 ITEM DESCRIPTION DRAWING NO PART NUMBER Angus Max-04 Angus Max-05 Angus Max-06 Angus Max-07 Angus Max-08 Angus Max-09 Angus Max-10 1 Front Section SX 001500111 SX-MD.060 SX-MD.060 SX-MD.060 SX-MD.060 SX-MD.060 SX-MD.060 SX-MD.060 2 Middle Section SX 001500112 SX-MD.050 SX-MD.050 SX-MD.050 SX-MD.050 SX-MD.050 SX-MD.050 SX-MD.050 3 Back Section SX 001500113 SX-MD.070 SX-MD.070 SX-MD.070 SX-MD.070 SX-MD.070 SX-MD.070 SX-MD.070 4 Cleaning Door SX 001500114

  • INSTALLATION, OPERATION AND MAINTENANCE MANUAL 18 Installation Instructions Boiler installation – general information Angus Max boilers must be put into service by an authorized services. A network of authorised service organisations which meet these conditions is available for all boiler installations, putting them into service and for warranty repairs. The boiler is designed to su

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 25 The figures below are only guide figures. The draft depends on the diameter, height, roughness of the chimney wall, and the temperature difference between combustion products and the outside atmosphere. We recommend the use of a chimney liner. Have precise calculations carried out by a heating engineer or flue installer. Coefficient = 0,041 (for wood) Coefficient = 0,027 (for carbon) F = Section Resulting (cm2) a = Coefficient Q N = Boiler Heat Output (kCal/h) H = Height of Chimney (meters)

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 19 Boiler location Angus Max boilers can be located both on non – habitable premises (e.g. in boiler room, cellar, corridor) and in habitable rooms. The room in which the boiler is located must have a permanent supply of air necessary for the combustion process. The air must be free of halogen hydrocarbons and corrosive vapours, and must not be excessively humid and dusty. The room must be protected against frost, with ambient temperature within the range +5°C to +35°C and relative humidity not exceeding 80%. To comply with fire regulations, the boiler must be inst

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 3 Technical parameters Boiler Type Angus Max-04 Angus Max-05 Angus Max-06 Angus Max-07 Angus Max-08 Angus Max-09 Angus Max-10 Number of Elements Pcs.45678910 Nominal Heat Output (Black Coal – Walnut) kW 35.0-38.0 44.0-48.0 54.0-58.0 63.0-67.5 73.6-77.0 83.5-86.0 91.0-95.0 Nominal Heat Output (Hardwood – Split Logs) kW 29.0-33.0 36.0-40.5 43.0-47.0 50.8-54.5 56.0-61.0 64.0-68.0 72.4-75.0 Heating Water Maximum Temperature ˚C 90 Heating Return Water Minimum Temperature ˚C 50 Safety Valve Temperature Limit ˚C 95 Burning Time For Nominal Output (B Coa

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 11 fig. 13 fig. 14 1. Boiler 2. Laddomat 21-60 operated by Flue Thermostat – 50-300°C 3. NAD or NADO Accumulator Tank 4. Immersion Heater 5. Three Way Mixing Valve 6. Circulating pump 7. Room Thermostat 8. Heating System Outlet 9. Open Expansion Tank 10. DHW Mixing Valve 11. Solar Coil 12. Solar 13. Solar Circulation Pump Systems for Pressurised Tank In a pressurized system consideration should be given for an appropriately sized expansion vessel on the central heating circuit before the return to the boiler and a safety group on the primary flow. It is essential to ensure that the ex

  • INSTALLATION, OPERATION AND MAINTENANCE MANUAL 7 Control and safety devices Angus Max boilers are equipped with three main control elements: A chimney flap (Fig. 05), by means of which the chimney thrust can be controlled, i.e. the discharge of combustion fumes into the chimney. The flap is situated in the flue neck of the boiler, and is controlled manually. fig. 05 Anothe

  • INSTALLATION, OPERATION AND MAINTENANCE MANUAL 23 Accumulator tank capacity NOTE: The heat can be supplied for example by an accumulator tank. The following applies as a reference for the minimum storage boiler content: V sp : Accumulator tank capacity in L Q N : Nominal heat output in kW T b : Burning period in h Q H : Heating load of the premises in kW Q min : Minimu

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 24 Flue pipe Installation Fig. 27 shows the proper flue gas connection with additional air equipment. Observe the following during the installation of the flue gas connection: ■ Install a flue pipe connection with an inspection aperture for cleaning. ■ Fasten the flue gas connector piece to the boiler. ■ Feed the connector into the flue gas system on a short, ascending path. Avoid deflections, especially those with an angle of 90°. ■ Fasten an

  • Eco Angus Max Multi Fuel, INSTALLATION, OPERATION AND MAINTENANCE MANUAL 16 Please note Ashes should be stored (by using proper glove) in a non-combustible container properly and transported outdoors. Other waste must not be stored in this container. fig. 17 fig. 18 fig. 19 fig. 20

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Chamberlain 257858 Owner's manual chamberlain/257858-SMM.pdf 05 Nov 2022 80 8.92 Mb
2 American DJ ActivePod User instructions american-dj/activepod-F8F.pdf 02 Mar 2023 4 0.95 Mb
3 HP LaserJet 1160 Specification sheet hp/laserjet-1160-Y59.pdf 14 Dec 2023 2 0.14 Mb
4 Ponpe BX615 Operation & user’s manual ponpe/bx615-7DZ.pdf 21 May 2023 28
5 Sony KV-AR212 Operating instructions manual sony/kv-ar212-825.pdf 18 Aug 2023 29
6 Cameo NANOROLL 200 Operation & user’s manual cameo/nanoroll-200-78A.pdf 04 Jan 2024 56

Similar Resources:

  • Baxi

    100/2 HE Plus

    (48 pages)
    Please leave these instructions with the userBaxi 100/2 HE PlusWall Mounted Powered Flue Condensing BoilerGas Fired Central Heating UnitInstallation & Servicing Instructions …
  • Bosch

    Worcester Greenstar Utility 32/50

    (48 pages)
    UKInstallation, Commissioning and Servicing instruction manualFloor Standing oil-fired condensing appliance conventional flue & room sealed flueGreenstar Utility ErP+ 32/50 & 50/706720821751-00.1WoFor fully pumped open vent or sealed central heating systems and domestic hot water cylindersThese appliances are for use with Kerosene (Class C2) only.6 7 …
  • Thermo Dynamics

    TDX-90

    (24 pages)
    InstallationOperationMaintenanceManualTDX SeriesThermo-Dynamics Boiler CompanyROUTE 61 • P.O. BOX 325 • SCHUYLKILL HAVEN, PA 17972(570) 385-0731 FAX (570) 385-5304www.thermodynamicsboiler.com …
  • A.O. Smith

    AWH-35

    (48 pages)
    Instruction ManualPRINTED 0114 318653-000PLACE THESE INSTRUCTIONS ADJACENT TO HEAT PUMP AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.COMMERCIAL ELECTRIC AIR-TO-WATER HEAT PUMP WATER HEATERMODELS AWH-35 to AWH-170SERIES 100INSTALLATION - OPERATION - SERVICE MAINTENANCE - LIMITED WARRANTY820 SW 41st StreetRenton, WA 98057Read and understand this instruct …
  • Baxi

    DUO-TEC COMPACT+

    (128 pages)
    itCALDAIA MURALE A GAS A CONDENSAZIONEManuale per l’uso destinato all’utente e all’installatoreen CONDENSING GAS WALL-HUNG BOILERSde KONDENSATIONS-WANDGASHEIZKESSELGebrauchsanleitung für den Benutzer und Installateurcs � …
  • Slant/Fin

    VICTORY VSPH SERIES

    (17 pages)
    Compact, oil firedpackagedcast-iron boilersINPUT:.83 GPH to 3.0 GPHNo.2 OilSave®~ iii~® ••Before purchasing this appliance,read important energy cost and efficiency informationavailable from your contractor. …

Comments, Questions and Opinions: