  • EcoQuest Breeze AT, 2 Advanced Technology Electronic Air Quality System CAUTION! - Disconnect power cord before servicing. 100, 110 volt models - use 1.0 Amp slow blow fuse. 220, 240 volt models - use 0.5 Amp slow blow fuse PE Location for Protective Earth Line. Did you forget to register your Breeze AT ? By registering, you’ll activate your warranty, and your privacy is guaranteed. Just fill out your warranty card and drop it in the mail. 310 T. Elmer Cox Drive Greeneville, TN 37743 423.638.7246 www.EcoQuest.com Copyright © 2003 Eco

  • EcoQuest Breeze AT, 3 APPLICATIONS Eliminates • Smoke • Odors • Tobacco Smoke Plus it works as an appliance to Sanitize an area to reduce: • Mold • Mildew • Bacteria NOTABLE FEATURES: • Remote Control • Variable Speed Fan • Sanitization Function • Adjustable Purification Control • Balanced Ion Production SPECIFICATIONS: Electrical: • 100 volt 50/60 hz, 110 volt 60 hz, 220 volt 50 hz, or 240 volt 50hz ac line operation depending on model • 30 watts power consumption • 24 to 30 KV, 20-30 Khz ion generation pulsator • Fixed 6 KV

  • EcoQuest Breeze AT, 4 PRINCIPLES OF OPERATION Nature cleanses the air with the lightning and rain. Lightning produces ozone, as well as positive and negative ions which cleanse the air naturally. Rain helps bring the ozone and ions closer to the earth's surface. They are then attracted to atmospheric contaminants that are either removed from the air and attached to grounded objects or are oxidized. Breeze AT reproduces the natural conditions found in the outdoors. It is not designed to create an artificial environment. The re-establishment of a natural environment takes place out in the air, rather than inside the unit. The Breeze AT cleanses the air using these natural processes. The Breeze AT also in

  • 5 Power / Ionizer Indicator Light Infrared Window and Remote Operation Indicator Purification Level / Sanitizer Indicator Lights Access Panel / Washable Filter Manual Controls Breeze AT Unit Features Breeze AT Remote Control Features • Variable Speed Fan • Adjustable Purifier control • Remote Control or Manual Operation • Portable • Computer style cord

  • EcoQuest Breeze AT, 6 Breeze AT Manual Controls Removing the Rear Lint Screen WARNING: DO NOT OPERATE the Breeze AT without the Rear Access / Filter Door installed correctly. POWER ON/OFF Fan UP Sanitizer Purifier UP Purifier DOWN Fan DOWN Purifier ON/OFF CAUTION: UNPLUG UNIT BEFORE SERVICING. NOTE: 110V MODEL DOES NOT USE LINT SCREEN CLIP - SKIP TO STEP 3 FOR MODELS WITHOUT CLIP. 1. Loosen 2 screws securing clip at top center of lint screen. 2. Slide clip up. 3. Gently pull top of lint screen out of unit. 4. Once the top is out of the unit, pick straight up on th

  • EcoQuest Breeze AT, 7 ECOTECH PURIFIER PLATE INSTALLATION The Breeze AT utilizes one Ecotech purifier plate. Installation is as follows: 1. Unplug the Breeze AT . 2. Remove the rear filter door (see previous page). 3. Fully insert the purifier plate between the guides until it stops. 4. Replace the filter door. WARNING: DO NOT OPERATE the Breeze AT without the Rear Access / Filter Door installed correctly. PLACING THE UNIT Place the unit as high as possible to insure complete purification. (On top of a bookshelf, high cabinet, etc.) Suggested locations, listed in the order of preference: 1. Nearest the source of the worst pollution. 2. Near a cold-air return to thoroughl

  • EcoQuest Breeze AT, 8 SETTING AND ADJUSTING CONTROLS WITH THE REMOTE TURNING YOUR BREEZE ON & OFF The Breeze AT will come on by pressing the POWER button on the remote. To turn on the Purifier feature, press the Purifier On/Off button once. To turn the Purifier feature off, press the Purifier On/Off again. 1. REMOTE FAN CONTROL The remote will set the fan by pressing the FAN UP or FAN DOWN button. To turn the fan off, press the POWER button (turns unit off as well). Increased air circulation improves the cleansing properties of the Breeze AT , so the fan control should be set as high possible without creat

  • EcoQuest Breeze AT, 9 square feet (square meters) approx. % output indicator lights lit 0 - 500 ( 0 - 46) 0- 20% 1 500 - 1000 (46 - 93) 20% - 40% 2 1000 - 1500 (93 - 139) 40% - 60% 3 1500 - 2000 (139 - 186) 60% - 80% 4 2000 - 2500 (186 - 232) 80% - 100% 5 Proper Purifier Level Settings for Indicated Square Footage NOTES ABOUT ADJUSTING THE PURIFICATION LEVELS The lights on the front of the Breeze AT indicate the approximate level of purifier output. You should adjust the level according to personal preference, but not exceeding the level recommended above for the square foota

  • MAINTENANCE Periodic maintenance is required to insure that the Breeze AT operates properly. A severely polluted environment can foul a purifier plate in as little as two weeks, normal plate cleaning should take place monthly. Shown here are basic procedures that should be carried out to keep your unit running at top performance. CAUTION: Unplug the Breeze AT befor

  • EcoQuest Breeze AT, TROUBLESHOOTING Indicators of Operation The Ionizer/Fan lamp should be illuminated whenever the unit is on. Depending on the current Purifier setting, between 1 and 5 of the small blue purifier lights should be illuminated. The SANITIZER light should be RED when the sanitizing feature is on. A small lamp or bulb is located at the base of the frequency type ionizer antenna. Turn the unit on and check that the lamp is illuminated. This verifies that the frequency type ionizer and needlepoint ionizer are functio

  • EcoQuest Breeze AT, 12 • Symptom: A strong odor of ozone is present within the environment. Problem: Too much ozone accumulation within the environment, as a result of improper purifier control setting, and / or lack of air movement. • Symptom: Visual haze of smoke and / or particulate remain within the environment. Problem: Lack of ionization and / or air movement. 6. Unit does not operate - • Is the unit plugged in? • Are you sure the outlet is active? • Is the main power switch turned on? • Is the rear lint screen installed properly to depress the safety switch downward? • Does the fuse need to be replaced

Related Products and Documents (Air Cleaner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Tannoy CVS 4 MICRO Installation manual tannoy/cvs-4-micro-6G8.pdf 26 Jul 2023 7 1.07 Mb
2 Hoshizaki Serenity Series KMS-1401MLJ Instruction manual hoshizaki/serenity-series-kms-1401mlj-5ZQ.pdf 12 May 2023 40 5.18 Mb
3 HP Vectra XA6 Operation & user’s manual hp/vectra-xa6-69B.pdf 03 Aug 2022 91
4 Tricity Bendix SE 211 Operating & installation instructions manual tricity-bendix/se-211-V8A.pdf 16 Feb 2023 20 1.34 Mb
5 Indesit FE10KC Owner's manual indesit/fe10kc-CK1.pdf 01 Sep 2023 8
6 HP PROLIANT BL45P Quickspecs hp/proliant-bl45p-OYY.pdf 19 Jan 2023 31

Similar Resources:

  • Lasko

    Pure Gold HF25620

    (8 pages)
    USE AND CARE GUIDEPure GoldHEPA-Type Slim Profi le Air Purifi erModel: HF25620HF25620ESNew 4/14 16SERVICIO AL CLIENTE:Número directo gratuito (800) 233-0268. Correo electrónico: [email protected] equipo de Servicio al Cliente está disponible para ayudarle con preguntas sobre el pro-ducto y los servicios, así como en referencia a los …
  • Honeywell

    2450Cm Series

    (2 pages)
    H2W2PC1M WDR 1080P People Counting Camera Quick Installation Guide Thank you for purchasing a Honeywell Performance Series IP camera. Follow the instructions in this guide to install and log in to your camera. For instructions on configuring the camera, refer to the user guide on the CD that came with your camera. If you require additional assistance, ca …
  • Carrier

    EACB0020

    (14 pages)
    Installation InstructionsNOTE: Read the entire instruction manual before starting theinstallationTABLE OF CONTENTSPAGESAFETY CONSIDERATIONS .............................. 1INTRODUCTION ..................................................... IDESCRIPTION AND USAGE .................................... 1INSTALLATION ............................................... …
  • Sharp

    IG-NX2E

    (76 pages)
    “Plasmacluster” and “Device of a cluster of grapes” are registered trademarks of Sharp Corporation in Japan, Philippines and elsewhere.* 1 The number on this technical mark indicates more than 50,000 ions supplied into air of 1 cm3, which is measured near the center of space (0.5 m height from floor) when the air volume is “MED” by placing the p …
  • Bionaire

    BAP600

    (8 pages)
    TROUBLESHOOTING 3 YEAR LIMITED WARRANTYSunbeam Products, Inc. doing business as Jarden Consumer Solutions or if in Canada, Sunbeam Corporation (Canada) Limited doing business as Jarden Consumer Solutions (collectively “JCS”) warrants that for a period of three years from the date of purchase, this product will be free from defects in material and workman …
  • Quatro

    AF400m

    (2 pages)
    Engineers Of Clean Air 30 Hymus Blvd., Pte-Claire, Quebec, Canada H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 [email protected] AF400m HEPA Air Purifier Instruction Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------ INTRODUCTION …

Comments, Questions and Opinions: