ElectrIQ AIRFLEX 15 Operation & User’s Manual
|
ElectrIQ AIRFLEX 15, Page 1 of 17 AIRFLEX 15 AIRFLEX 15AIRFLEX 15 AIRFLEX 15 PORTABLE AIR PORTABLE AIR PORTABLE AIR PORTABLE AIR CONDITIONER CONDITIONERCONDITIONER CONDITIONER WITH HEAT WITH HEATWITH HEAT WITH HEAT PUMP PUMPPUMP PUMP USER MANUAL Thank you for choosing ElectrIQ. Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electrIQ.co.uk for our entire range of Intelligent Electricals
ElectrIQ AIRFLEX 15, Page 2 of 17 CONTENTS 1. .. .SAFETY INSTRUCTIONS ………………………………….. 3 2. .. .FEATURES AND PARTS LIST ………………………….... 4 3. .. .INSTALLATION …………………………………. …………. 5 4. .. .CONTROL PANEL AND SETTINGS …………………….. 7 5. .. .OPERATION MODE ,,,,,,,,,,,,,,,,,,,,,,,,……………………….. 9 5. .. .WATER-DRAINAGE …………………………………………. 14 6. .. .M
Page 3 of 17 SAFETY INSTRUCTIONS Important! • Carefully read the instructions before operating the unit. • This Air Conditioner has an IP24 rating. It is designed mainly indoor use only but will stand outdoor use being protected against light rain and splashing. • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. • Instal
ElectrIQ AIRFLEX 15, Page 4 of 17 FEATURES AND PARTS LIST 1. Features Part of ElectrIQ ® range of Intelligent Air Conditioning products Cooling, Heating and Dehumidifying (70l/day) for all around the year use Powerful and Flexible for both Domestic and commercial use Unique optional comfort kit with wired remote control that will enable operation with the unit outside the room that needs air conditioning making it ideal for use in server rooms, offices, military tents or barracks, marquees Improves comfort and
ElectrIQ AIRFLEX 15, Page 5 of 17 INSTALLATION Warning: :: :Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface. Unpacking Open the box and remove all the packing out of way Grip the unit by the carry handles located on either sides of the unit and carefully lift until it slides out of the foam base Remove the air outlet and take out the exhaust hose as in the picture. Install the exhaust hose on the unit before operating the unit CONT
ElectrIQ AIRFLEX 15, Page 6 of 17 Assemble hose fish tail adaptor: Prepare both parts of hose adaptor and clip them together. Do not push too hard as this may cause damage. Extend one head of the hose and screw the adaptor to it. Note: to screw it into place should take no less than three rotations Installation of window kit Partially open the window and then fix the window kit to the window horizontally or vertically. Keep at least 50 cm from any objects and the air inlets grills on the side of the unit. Clip the other end of the hose with the fishtail adapter to the air outlet of the window slid
ElectrIQ AIRFLEX 15, Page 7 of 17 CONTROL PANEL AND SETTINGS This portable air conditioner boasts four functions: cooling, heating, dehumidifying. The fan has three speeds: high, medium and low Temperature range settings are: 18--30 0 C The unit will also display operating function, temperature, fault diagnostic and protective functions on the LED screen. Control instruction : :: : Control panel: :: : When plugged in the unit is automatically in standby status (1) POWER button Press this button to turn the unit on and enter cooling mode. Press again and the unit w
ElectrIQ AIRFLEX 15, Page 8 of 17 resume operation, please remove the rubber cap of the drain hose and empty the tank. The E4 warning will disappear after draining, and the unit can be restarted by pressing the POWER key. (6) SPEED Fan button HIGH→MEDIUM→LOW and AUTO If "AUTO" is selected during cooling function the fan speed will automatically be adjusted to HIGH, MEDIUM or LOW according to the difference between settings and ambient temperature. e.g. if ambient temperature is 9°C higher than set temperature, the fan will run on High. If the temperature reduces to a less than 4 °
Page 9 of 17 3. Multi protective function 3.1 Anti-freezing protecting control: When the ambient temperature is low while in Cooling Mode, the compressor and water pump will stop working if the copper coil temperature is too low. When the copper coil temperature increases, the protection will be stopped automatically. 3.2、Water-full protection: When the w
ElectrIQ AIRFLEX 15, Page 10 of 17 COOLING On very warm days we recommend programming the unit to start early, before direct sun hits the room to cool and set it to a comfortable 20-22 °C . ElectrIQ Airflex 15 is a self-evaporating air conditioner, so under normal use there will be no need to empty the internal tank. However if there is a high amount of humidity in the air or the unit is not vented correctly water will be collected in the internal tank. Also if the unit operates in cooling mode for a longer period and especially at a time of year with high er air humidity, the internal condens ation tan
ElectrIQ AIRFLEX 15, Page 11 of 17 Place the unit in the shade if possible and in a cool, protected place in order to increase efficiency and to avoid overheating. At an ambient temperature of over 32°C, the unit will stop cooling protecting the compressor. If this become recurrent we recommend you use the INDOOR COOLING OPERATION. We recommend that drainage hose for condensation water must be connected. Set the function to „COOLING“. The selectable temperature range is between 17°C and 30°C. Fresh cold air with high oxygen content cooled by the unit is led into the room via the air hose. The hose can be vented v ia a tilted window, a door or wall aperture. Make
ElectrIQ AIRFLEX 15, Page 12 of 17 HEATING WHEN AC IS PLACED OUTDOOR Connect the Hot air hose as displayed in the illustration after exchanging the grills. The air hose will expel the cold air from the room outside while the front grills produce hot air. The unit is placed outside the room to be heated. Outdoor operation is ideal for the autumn period in which outside temperatures do no fall below 10°C. (If the outside temperature should however fall below 10°C continuously, we recommend indoor operati
ElectrIQ AIRFLEX 15, Page 13 of 17 WATER-DRAINAGE This model is an advanced self-evaporative air conditioner, which reduces the need to empty the water tank in cooling mode. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Please do not use continuous drainage if you intend to use the self-evaporating facility for improved cooling effect. Do not use air exhaust hose vented out if you want to maximise the dehumidifier mode water extraction. 1
ElectrIQ AIRFLEX 15, Page 14 of 17 Maintenance Cleaning Please shut off the unit and unplug from the mains before cleaning or performing any maintenance Clean the surface Clean the plastic housing with a duster or a soft wet cloth. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage. Air filter cleaning a) Clean the air filters every 2 weeks. If the air filter is blocked with dust, the unit’s performance will be significantly affected. b) Pull out lightly the top and bottom filters as pictured below c) Wash the air filters by immersing them in warm (about 40°C) water with
ElectrIQ AIRFLEX 15, Page 15 of 17 End of Season Maintenance: :: : 1. Pull out the plug from the drainage hole and empty the internal tank. You can also drain the water by leaning the unit. 2. Then switch the unit to low fan mode in cooling mode at set > than ambient temperature (this way unit will work in fan mode only) 3. Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep the inside of the unit dry and prevents mold developing 4. Turn off the unit and pull out the plug. 5. Separate the air-exhausted pipe and store it safely. 6. Cover
ElectrIQ AIRFLEX 15, Page 16 of 17 APPENDIX Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when
Page 17 of 17 ElectrIQ UK SUPPORT www.ElectrIQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. If the unit still fails to operate call: 0871 620 1057 or complete the online form 1. Has the unit been standing upright for at least 2 hours? 2. Is the unit plugged into the mains?
DOWNLOAD |
ElectrIQ SILENT10 Air Conditioner Operation & user’s manual
SILENT10 |
ElectrIQ P15HP Air Conditioner Operation & user’s manual
P15HP |
ElectrIQ SILENT 12 Air Conditioner Operation & user’s manual
SILENT 12 |
ElectrIQ eiQ-CRFC18K Air Conditioner Instruction and installation manual
eiQ-CRFC18K |
ElectrIQ AIRFLEX15 Air Conditioner Operation & user’s manual
AIRFLEX15 |
ElectrIQ Platinum Series Air Conditioner Operation & user’s manual
Platinum Series |
ElectrIQ eiQ-FC18K Air Conditioner User and installation manual
eiQ-FC18K |
ElectrIQ eiQ-3MS9K9K9K Air Conditioner User and installation manual
eiQ-3MS9K9K9K |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | bora | PT11UMEN-000 | Operating and installation instructions | bora/pt11umen-000-93Y.pdf | 26 Dec 2023 | 24 | |
2 | Linksys | Network Router | How to use manual | linksys/network-router-5X6.pdf | 03 Oct 2023 | 42 | |
3 | Panasonic | BL-C10A - Network Camera - Pan | Operating instructions manual | panasonic/bl-c10a-network-camera-pan-2H7.pdf | 29 Aug 2023 | 104 | |
4 | Kohler | WP2700 | Owner's manual | kohler/wp2700-6K7.pdf | 21 May 2023 | 48 | |
5 | IOGear | GCS1212TAA | Installation manual | iogear/gcs1212taa-B9I.pdf | 10 Oct 2022 | 16 | |
6 | Korg | pa 900 | Manual | korg/pa-900-LBI.pdf | 18 Mar 2023 | 112 |
Truma
TR Page 88 Gebrauchsanweisung Seite 2Einbauanweisung Seite 11Im Fahrzeug mitzuführen! Operating instructions Page 15 Installation instructions Page 23To be kept in the vehicle! Mode d‘emploi Page 27Instructions de montage Page 35 À garder dans le véhicule ! Istruzioni per l‘uso Pagina 39Istruzioni di montaggio Pagina 47Da tenere nel …
Saphir vario(88 pages) |
Panasonic
Wall Mounted Air Conditioner - Low Ambient System: KS30NKUA Indoor/Outdoor: CS-KS30NKU/CU-KS30NKUAPower V/PH/Hz 230/208/1/60Circuit AmpacityFuse Size, Max.CompressorNo. usedR.L. Amps - L.R.Outdoor UnitFan type Dia. (in.) - No. SpeedsType DriveNo. PolesNo. MotorsCFMF.L. AmpsCoil TypeFin Type - Pipe TypeRows - F.P.I.Face AreaTube SizeIndoor UnitFan type …
KS30NKUA(2 pages) |
Mitsubishi Electric
Air-Conditioners For Building Application Inverter Y-SeriesOUTDOOR UNITPUHY-P-YKB-A1 (-BS) For use with R410AINSTALLATION MANUALFor safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.INSTALLATIONSHANDBUCHZum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründ …
CITY MULTI PUHY-P-YKB-A1(53 pages) |
Addison
P/N AD111101NA 10/13 Rev. CWARNINGFOR YOUR SAFETYIf you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6. Leave the building. 7. Immediately call your local gas supplier after leaving the building. Follow …
UHAT 150(74 pages) |
Sanyo
Pub. OI-85464189508000 ©SANYO 2002INSTRUCTION MANUALSplit System Air ConditionerSave These Instructions!Printed on Recycled PaperKS2462RCOOL/DRY ModelIn order to protect the environment, this air conditioner uses the new refrigerant R410A.
…
KS2462R(24 pages) |
Daikin
EnglishSplit System air conditionersINSTALLATION MANUALInstallation manualSplit System air conditionersR200F7W1R250F7W1RY200F7W1RY250F7W1RP200B7W1RP250B7W1RYP200B7W1RYP250B7W1
…
RP200B7W1(12 pages) |
VIORE LCD TV LC40VF60LCD TV PDF Manual LC40VF60, 23 |
Lenmar Adapter LAC50Adapter PDF Owner's manual LAC50, 3 |
COMPRO TV X500 - START UP GUIDECOMPRO TV X500 - START UP GUIDE Manual X500 - START UP GUIDE, 32 |
Hotpoint Dryer CTD00#XYLW17 CTD00: Hotpoint Dryer Owner Documentation CTD00, 16 |
Landmann Grill BLACK DOG 42 XTLandmann BLACK DOG 42 XT Guide (Assembly and operating instructions manual), @MQR67M BLACK DOG 42 XT, 22 |
Geo Pager N8TN8T Operation & user’s manual - 87NXH3 N8T, 9 |
Kenmore Washer 110.2972 series110.2972 series Quick start manual - L1Y84C 110.2972 series, 6 |
Caple Ventilation Hood Ceramica CR700WManual: Caple Ceramica CR700W (11HUBR, Upd.Sunday 20-08-2023) Ceramica CR700W, 16 |
WELLTECH Telephone IP VIDEO PHONEIP VIDEO PHONE Operation & user’s manual - TPA69J IP VIDEO PHONE, 34 |
Buffalo Adapter HD-PNFU3Adapter PDF Operation & user’s manual HD-PNFU3, 7 |
IBM Server eserver pSeries 7311 D10Server #2K56V9 eserver pSeries 7311 D10, 228 |
meitav-tec Thermostat MTS/SUPER/CO2 seriesGuide: meitav-tec MTS/SUPER/CO2 series (DGR52D, Upd.18.01.2024) MTS/SUPER/CO2 series, 40 |