Manualios.com

Electro-Air 10C26S-010 Owner's Manual

Electro-Air 10C26S-010 Manual Online:

3.95, 1001 votes
Electro-Air 10C26S-010 User Manual
Electro-Air 10C26S-010 User Guide
Electro-Air 10C26S-010 Online Manual

Text of Electro-Air 10C26S-010 User Guide:

  • Electro-Air 10C26S-010, Part No. 37-6068B Replaces 37-6068A 0021 SST Super Slim Twin Model Number 10C26S-010 14C26S-010 16C28S-010 20C26S-010 OWNERS MANUAL • Installation • Operation • Basic SST Service Guide • Technical Repair Guide • Repair Parts Electronic Air Cleaner Printed In U.S.A. UL Listed CSA Certified by White-Rodgers Please read and familiarize yourself with the contents of this manual before installing, operating or performing maintenance on the unit. WHITE-RODGERS SUPER SLIM TWIN ELECTRONIC AIR CLEANER OPERATING LIGHT OFF ON

  • Electro-Air 10C26S-010, 2 RULES FOR SAFE INSTALLATION AND OPERATION Please read instructions before installing and using the Electronic Air Cleaner. This will help you obtain the full benefit from the Electronic Air Cleaner you have selected. WARNING ! ELECTROCUTION HAZARD Shut off power at fuse panel before servicing. Failure to do so could result in serious personal injury or death. WARNING ! Do not attempt installation of this unit unless you are familiar with the necessary tools, equipment, utility connections and potential hazards. Installation should be perfor

  • 3 HOW THE AIR CLEANER WORKS Dirt particles flowing through the ducts (Figure 1) first enters the pre-filters (A) where large particles (hair, lint, etc.) are trapped. Smaller particles (smoke, dust, pollen, etc.) pass through these pre-filters and enter the ionizing section (B). Here each tiny particle receives a positive electrical charge. These charged particles then enter

  • Electro-Air 10C26S-010, 4 PREINSTALLATION tions. Turn cells upside down (with the same end facing the cabinet opening). This will locate the ionizing wires at the right, and both contact buttons and cell handles will be facing the power door. Air flow direction must agree with arrow embossed on end of collecting cells. After installing the cell sections, install pre-filters in cabi- net tracks on the right. This will again place the pre-filters on the air entering side (on the same side as ionizing wires). LOCATING THE AIR FILTER Your air filter must be mounted in the return air

  • Electro-Air 10C26S-010, 5 TYPICAL MOUNTING POSITIONS BASEMENT FURNACE (LOWBOY) (Figure 6) Cleaner is mounted hori- zontally in return plenum, just above furnace. COUNTERFLOW FURNACE (Figure 7) Cleaner is mounted horizon- tally in return duct or plenum, just above furnace. HIGHBOY FURNACE (Figure 8) Side installation. Cleaner is mounted vertically, where return air enters side inlet of furnace. OFFSET INSTALLATION (Figure 10) Typical use of duct offset to match air filter opening. If duct connection to furnace allows less than nine inches for mounting th

  • Electro-Air 10C26S-010, 6 INSTALLATION REMOVE OLD FILTER AND DISCARD (Figure 12) NOTE: This filter may be mounted in the furnace compart- ment. CLEAN BLOWER COMPARTMENT It is suggested that the furnace blower compartment, blower and blower housing be cleaned to ensure clean air circulation. INSTALLATION The following is a typical installation of the air cleaner on a “Highboy” furnace (Figure 8). 1. Place the air filter cleaner on the floor. Stand it upright with the power door facing you (Figure 4). If a horizon- tal installation is being planned, lay the cleaner on its side, this will help you to visualize the relative location of all p

  • Electro-Air 10C26S-010, 7 WIRING INSTRUCTIONS 7. With the cabinet installed, the air cleaner can now be wired to electrical input source. WARNING ! Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to in- stallation. Failure to do so could result in serious personal injury or death. 8. Since this air cleaner unit has an air flow monitor installed, it does not require electrical wiring through the furnace controls. This unit requires a 120 VAC 60 Hz input circuit. A 20 amp circuit is more than ad- equate. 9. Remove junction box cover and install the required bushing into the 3/4 in. Knock out. With the supply voltage turned off, rout

  • Electro-Air 10C26S-010, 8 OPERATION 1. With the 120 VAC power turned on at the circuit breaker for the furnace, push the air cleaner ON-OFF switch to the “ON” position (Figure 20). 2. With the furnace blower running, the air cleaner will be operating. An arcing or “snapping” sound may be heard. This will occur occasionally, however the unit is operating properly. 3. With the furnace blower running, the Operating Light should be ON. If the Operating Light is not ON this signifies that the cells need washing, or that trouble exists in the unit. If, after washing the cells, the Operating L

  • 9 REPLACING AN IONIZING WIRE If an ionizing wire should break, it can be replaced as follows: 1. Remove all pieces of broken wire. Make sure sup- ports at each end are in good condition and not bent out of shape. 2. Hook the new wire onto the support at one end. 3. Hold your finger against the support at the other end (Figure 21) and hold the ionizing wire between thumb and forefinger as shown

  • Electro-Air 10C26S-010, 10 SERVICE INDICATION SERVICE CHECKS ON/OFF switch “ON” Unit functioning Normally Blower ON Operating Light ON ON/OFF switch “ON” 1. Power is not being supplied to air cleaner. Blower ON A. Check fuse or circuit breaker. Operating Light OFF B. Ensure power pack is properly installed and latched. 2. Collecting cell shorted - Turn power Off - Remove power pack - Remove collecting cells - Replace power pack - Restore power (ensure blower is operating). A. If Operating Light comes ON check cells for bent plates, loose ionizing wire(s) or cracked insulator(s). B. If Operating Light remains OFF, malfunction is in the power pack. (See power sup

  • Electro-Air 10C26S-010, 11 TECHNICAL REPAIR GUIDE All voltage measurements indicated can be made with a high voltage D.C. probe and a general purpose volt ohm meter. For example: Simpson 260 or equivalent. For test purposes, the air flow switch may be “wired out” of the system. This will eliminate the need for air flow across the sensing thermistor to energize the power supply (see Fig 23). NOTE: All tests to be performed with the Ozone Reduc- tion Jumper intact. NOTE: When servicing the power pack components, all wiring must be routed to factory specifications. WARNING ! Do not attempt repair of this unit unless you are familiar with the necessary tools, equipment, util- ity

  • Electro-Air 10C26S-010, 12 POWER SUPPLY CHECKOUT PROCEDURE 1. Turn power switch to the “OFF” position and remove the power pack from cabinet. 2. Locate air flow switch and remove power pack cover. Disconnect the three-pin plastic connector. 3. Jumper the two female pins (white wire to white- brown wire) as shown in Fig. 23. Jumper Lead Female Pins Male Pin Plastic Connector Method of jumping lead wires of connector plug from air flow switch. Figure 23 4. Place power pack on a well insulated workbench. Connect meter negative (-) lead to the sheet metal chassis and the high voltage probe to high voltage contact on back cover of power pack. Connect AC power to power pack using an extension cord and

  • Electro-Air 10C26S-010, 13 OZONE REDUCTION All electronic air cleaners typically produce a small amount of ozone that is within established limits. Some customers may notice an odor especially at high altitudes or low air flow rates. This power supply has a “hairpin” shaped jumper wire labeled W1 (see Fig 24) that can be cut and separated in case of such complaints. This will cause the power supply to limit the maximum operating power to a lower level. LINE WHT/BRN BLK W1 E3 E2 Ozone Reduction Jumper Cut and separate Ozone Reduction Jumper Figure 24

  • 15 ITEM NO. DESCRIPTION PART NUMBER 10C26S-010 14C26S-010 16C28S-010 20C26S-010 1 Cabinet N/A N/A N/A N/A 2 Pre-Filter • F825-0431 • F825-0432 • F825-0337 • F825-0338 3 Collecting Cell • F811-0398 • F811-0397 • F811-0321 • F811-0319 4 Junction Box Cover F838-0072 F838-0072 F838-0072 F838-0072 5 * Screw #6 x 3/8 ------ ------ ------ ------ 6 Connector, Female F

  • Electro-Air 10C26S-010, White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road, St. Louis, MO 63123-5398 314-577-1300 • FAX 314-577-1517 www.white-rodgers.com Controlling America’s Indoor Comfort NOTICE TO CONSUMERS White-Rodgers Electronic Air Cleaner Dear Consumer; White-Rodgers would like to thank you for purchasing a White-Rodgers Electronic Air Cleaner or product containing a White-Rodgers Electronic Air Cleaner. Although White- Rodgers does not extend a warranty directly to consumers, White-Rodgers does extend a warranty to Wholesalers and Original Equipment Manufacturers who use White-Rodgers Products. To obtain more information about how your

Related Products and Documents (Air Cleaner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Frigidaire FGHS2634KQ - Gallery 26 cu. Ft. Refrigerator Service data sheet frigidaire/fghs2634kq-gallery-26-cu-ft-refrigerator-G83.pdf 11 Jun 2023 23 1.45 Mb
2 Canon EOS REBEL XS Instruction manual canon/eos-rebel-xs-GHH.pdf 01 Nov 2022 95 11.56 Mb
3 Coby MP822-4G Quick setup manual coby/mp822-4g-Y72.pdf 20 Jul 2023 60 1.34 Mb
4 Uniflame CBT702WB Owner's manual blue-rhino/cbt702wb-V97.pdf 26 Jul 2023 16 4.16 Mb
5 Curtis RCD302 Specification sheet curtis/rcd302-3NV.pdf 06 Jul 2023 1 0.12 Mb
6 Hobart WS-C208 Installation & instructions for use hobart/ws-c208-B4U.pdf 11 Nov 2022 12

Similar Resources:

  • Sterling

    HEPAPro AS800

    (4 pages)
    HEPA Air Scrubber (HEPAPro AS800)The HEPAPro AS800 is a compact, portable HEPA Air Scrubber for abatement, resto-ration, and construction projects. It is commercial, yet lightweight machine that is easy to carry, transport and store. The unit has a 22” x 24” footprint, stands only 14” tall and weighs less than 35 lbs. HEPAPro AS800 oers variable a …
  • Aerus

    QuietPure Whisper

    (4 pages)
    65-00617_VA-00915READ AND SAVE THESE INSTRUCTIONSSmall Room Smart Air Purifier FCC DECLARATION OF CONFORMITYName: Aerus Health Direct, LLCModel: A1027AManufacturer: Aerus Health Direct, LLCThis device complies with Part 18 of the FCC Rules.RESPONSIBLE PARTY Aerus Health Direct, LLC 300 East Valley Drive Bristol, VA 24201Ph: 888-764-0693Signature: _______ …
  • Teka

    ZING

    (22 pages)
    Operating instructions (Translation of the original operating instructions) ZING TEKA Absaug- und Entsorgungstechnologie GmbH, Industriestraße 13, D-46342 Velen, Tel.: +49 2863-9282-0, E-Mail: info@teka.eu, www.teka.eu 1 …
  • AAF

    AstroPure 550C

    (4 pages)
    THE WOR L D LEADER IN CLE A N AIR S O LUTION SAstroPure™ 550CAIR PURIFIER•••• H14 True HEPA FilterEffectively removes up to 99.995% ofultra fine particlesWi-Fi Smart ControlControl your unit anywhere and anytimethrough our AAF Connect mobile appUV-C LightUltraviolet light feature to provide additional protection against airborne infectionPM & …
  • Philips

    AC4002

    (2 pages)
    Philipsbedroom air purifier•bedroom•30 m²AC4002A healthier sleep, alwaysPurifier with dedicated Sleep modeGet your better night's sleep with the Philips air purifier. Its dedicated Sleep mode with dimmed indicators quietly cleans the air of bacteria and allergens. The healthy air protect alert and lock assure you of healthy air always.Healthy Air …
  • Fellowes

    AeraMax Pro AM II

    (56 pages)
    AeraMax® Pro AM II1789 Norwood Avenue, Itasca, Illinois 60143 • 1-800-955-0959 • www.fellowes.comBrands© 2019 Fellowes, Inc. | Part #411645Declaration of ConformityFellowes Manufacturing CompanyYorkshire Way, West Moor Park, Doncaster, South Yorkshire, DN3 3FB, England Declares that the product AeraMax® AMII Pro conforms to the following requi …

Comments, Questions and Opinions: