Manualios.com

Data Connect V.3600UI Operation & User’s Manual

Data Connect V.3600UI Manual Online:

4.8, 2390 votes
Data Connect V.3600UI User Manual
Data Connect V.3600UI User Guide
Data Connect V.3600UI Online Manual

Text of Data Connect V.3600UI User Guide:

  • Data Connect V.3600UI, CHAPTER 5 : INSTRUCTION SETS 5.4 V.25bis Auto call Unit V.25bis auto call unit is used for auto calling in asynchronous and synchronous data formats. 1. V.25bis Commands a. CRNx - Call request - dial a phone number (x) entered on DTE keyboard. b. CRSy - Call request - dial a phone number stored in specified memory address (y). y=0-9. c. PRNy;x - Program number - store a phone number (x) in specified memory address (y). y=0-9 d. RLN - Request list of all stored numbers. e. CIC - Connect incoming call. Auto answer enable. f. DIC - Disregard incoming call. Auto answer d

  • Data Connect V.3600UI, CHAPTER 3 : FRONT PANEL AND MENU TREE 3.5.2 DIAL MENU Item Name Command Description Dial a Number \#0...#9 ATDSn Dial out a preset telephone number #n(n=0..9). This function can interact with the auto redial function or dial line auto establishment function. Edit a Number \#0...#9 AT&Zn = xx Edit telephone number #n (n=0..9) for up to 20 digits each group.If the "@" is included inside the number and auto-redial is ON, then it will redial next number after no answer until the number without "@". If it is still unsuccessful then retirn to the first num

  • APPENDIX 1: S-REGISTER TABLE 10 - reserved 11 - reserved 13 - reserved 14 - reserved 15 - V32_4800 16 - V32b_7200 TCM 17 - V32_9600 TCM 18 - V32_9600 QAM 19 - V32b_12000T 20 - V32b_14400T 26 - V34_19200 27 - V34_24000 28 - V34_28800 29 - reserved

  • Data Connect V.3600UI, APPENDIX 1: S-REGISTER TABLE S22 01110110 binary Bit Mapped Options bit 1,0 - speak volume 00 - low *01 - medium 10 - high 11 - reserved bit 3,2 - speak control 00 - off *01 - speaker on until carrier detected 10 - always on 11 - off when dial bit 6,5,4 - result code and call progress 000 - ATX0 CONNECT without speed message, blind dial, no busy tone(Basic Code) 001 - reserved 010 - reserved 011 - reser

  • Data Connect V.3600UI, CHAPTER 3 : FRONT PANEL AND MENU TREE CHAPTER3 FRONT PANEL AND MENU TREE 3.1 The Front Panel Description 3.2 The Rear Panel Description 3.3 Operating the Network Series Modem 3.4 The Menu Tree 3.5 Detailed Description of the Menu Tree 15

  • Data Connect V.3600UI, CHAPTER 3 : FRONT PANEL AND MENU TREE 3.5.7 COMMAND MENU Item Name Command Description Command Mode ATS19=n Intelligent function command set selection. AT command (bit1.0) /Hayes compatible "AT" command set with async format. V.25bis command /ITU-T V.25bis command set with async, Bisync and HDLC\SDLC formats. Dumb mode /Dumb mode, don't accept any command. This mode is set for all leased line and most of the sync dial line to prevent modem from interference made by the da

  • Data Connect V.3600UI, CHAPTER 4: GENERAL INFORMATION AND FEATURES 4.10 Auto Dial Back-Up When you apply the modem to leased lines, no matter what protocol you are using, in case that the lines don't function well, you may allow modem dial a stored number via a dial line to rebuild the connection. This line is called "back-up line." While using the back-up line, the modem periodically checks the recovery of leased lines to find the opportunity to go back to leased lines in order to save the charge of dial line.

  • Data Connect V.3600UI, CHAPTER 3 : FRONT PANEL AND MENU TREE 3.5.3 PROTOCOL MENU Item Name Command Description Protocol Type AT\Nn Select error correction and data compression function for async mode only. *This setting is ineffective in sync mode. It will automatically become direct mode regardless of setting made once the link established. Normal AT\N0 /with DTE speed conversion only.Note that the flow control function must be active. Direct AT\N1 /disable error correction, data compression, and DTE speed conve

  • Data Connect V.3600UI, CHAPTER 3 : FRONT PANEL AND MENU TREE 3.5.8 LINE SETUP MENU Item Name Command Description Line Type AT&Ln Select line type and also set dial back-up function. Dial Line AT&L0 /Dial line. 2W Leased AT&L1 /2 wire leased line. 4W Leased AT&L2 /4 wire leased line. Leased to Dial ATS31=n Auto dial back-up control while leased line is out of service. Manual (bit0) \Manual control (default) Auto /Auto dial back-up. Backup Tel. Select backup telephone number #n (n=0~9) No dial backup /Disable backup function (default) #0 nnnn .. to #9 nnnn /Enable backup function and make a choi

  • Data Connect V.3600UI, CHAPTER 4: GENERAL INFORMATION AND FEATURES 4.7 Configuration Profile Set-Up The Network Series Modem have various operating modes. To save your energy, it provides 10 sets of factory default settings as well as 10 sets of user setup profile which store data even the power is off. Users may choose the most similar factory default setting; make some modifications with front panel or by AT commands from terminal then save the modified setting to a user profile. From then on, once the modem is turned on, it will use this user profile as default. You may find the “Load”

  • Data Connect V.3600UI, APPENDIX 1: S-REGISTER TABLE S42 00000010 binary Bit Mapped Options bit 0 reserved bit 1 0 - receive power drop control off *1 - receive power drop control on bit 2 *0 - enable V.34 asymmetrical rate 1 - disable V.34 asymmetrical rate bit 3 *0 - disable dial to dial 1 - enable dial to dial bit 7,6,5,4 0000-1010 - Pre-Emphasis Filter Suggestions Number 0-A *1011-1111 - Ignore Pre-Emphasis Filter S43 00000000 binary Fast Connect Control bit 3,2,1,0 - Answer tone length (100ms time base.) 0ms-1500ms bit 4 - Fast connect on/*off (1/*0) bit 7,6,5 - reserved S44 Reserved

  • Data Connect V.3600UI, Contents CHAPTER 1: MODEM INTRODUCTION....................................2 1.1 Description ..........................................................................................................2 1.2 Technical Specifications .....................................................................................3 1.3 Ordering Information .........................................................................................7 CHAPTER 2: INSTALLATION ..................................................................................10 2.1 Description ............

  • APPENDIX 1: S-REGISTER TABLE 10 - reserved 11 - reserved bit 3,2 - reserved bit 7-4 - Login check 0000..1001 - #0..#9 1010 - ALL 1011 By NMS *1100.. 1111 Disable security check S25 00 100ms DTR Debounce Time bit 3,2,1,0 - DTR drop detection time bit 7,6,5,4 - DTR rising detection time S26 0

  • Data Connect V.3600UI, CHAPTER 3 : FRONT PANEL AND MENU TREE H. LINE SETUP MENU Line Type Dial \2W Leased Line\4W Leased Line Leased To Dial Manual\Auto Backup Tel No Dial Backup\#0nnnn\#1nnnn \…\#9nnnn Backup Speed V34 Adaptive\V34+ 336\V34+ 312\V34 288 \V34 264\V34 240\V34 216\V34 192 \V34 168\V34 144\V34 120\V34 96 \V34 72\V34 48\V34 24\V32b Adaptive \V32b 144\V32b 120\V32 96Q\V32 96T \V32b 72\V32 48\V26b 2400\V26b 1200 \V23 1200\V22b 2400\V22 1200 \BELL 212A\BELL 103\V21 300 Dial To Leased Manul\Auto Dial To Leased Timer Forver\0~255 Minutes Dial to Dail Off\On I. PROFILE MENU Load

  • CHAPTER 3 : FRONT PANEL AND MENU TREE 3.5 Detailed Description of the Menu Tree 3.5.1 STATUS MENU Item Name Command Description TX LEVEL = -XX dBm AT%S Transmitted signal level. This value is equal to the " TX level" of config modem. Normally, for the 2w leased line and the dial line, the recommended value is between -10 and -13dBm. It can be

  • Data Connect V.3600UI, CHAPTER 3 : FRONT PANEL AND MENU TREE ORG/ANS Mode Answer Mode\Originate Mode Auto Retrain On\Off Tx Clock Internal\External\Loopback Retrain Threshold High \Medium \Low ASI Overspeed +1%…-2.5% \ +2.3%…-2.5% Make/Break US (39%)\UK (33.3%) Force Off Hook Force a off hook activity using "Enter" key OH by DTR On\Off Pump Edit □□□ : □□□□ FB\FF Ctrl Off\On LL Tx Level 0 dBm...-31 dBm DL Tx Level 0 dBm...-15 dBm Remote Access On\Off Dynamic Range -12..-44dBm\ -2..-35dBm F. CONFIG DTE MENU DTE Speed 115200 b

  • Data Connect V.3600UI, CHAPTER 3 : FRONT PANEL AND MENU TREE B. Menu Select Exp 1 : Exp 2 : L MENU Select STATUS L MENU Select TEST Description: 1) In top menu, press "ENTER" key to enter this menu. 2) Select "LOCAL"or "REMOTE" first if connected and remote access function enabled. 3) The character "L" on the upper left corner stands for local. 4) You may use " " and " " keys to select menu. 5) Press "ENTER " key to enter the "MENU". 6) Press "EXIT" key to quit from this menu. 7) Note that status menu is not available before connection. C. Menu Screen

  • CHAPTER 2: INSTALLATION 2) If you are unsure whether the electrical service in your building is properly grounded, have it examined by your municipal electrical inspector. 3) Install a surge protector between the modem and AC power outlet. Any additional computer equipment you have connected to the modem (directly or through another device), such as a terminal or printer, sho

  • Data Connect V.3600UI, CHAPTER 3 : FRONT PANEL AND MENU TREE password. Time required for sending password is about 2 seconds; Control code ‘+’ can be applied in #0..#9. CallBack No. (Call back telephone number). Assign one of the stored phone number #0..#9 as the Call Back Number. Control codes such as ‘+’, ‘<’, ‘>’ should not appear in phone number. #0..#9 CallBack Timer The period ANS modem will delay before start Call Back procedure (from Idle to Dial). When this option is se

  • Data Connect V.3600UI, CHAPTER 5 : INSTRUCTION SETS Cmd Function Description AT%Bn modem speed 0 : V.34_Adaptive 1 : V21_300 / FAX 300 2 : B103_300 3 : V22_1200 4 : B212_1200 5 : V22_2400 7 : V23_1200 8 : V26b_1200 9 : V26b_2400 10 : V27_2400 11 : V27_4800 13 : V29_7200 14 : V29_9600 15 : V32_4800 16 : V32b_7200 17 : V32_9600T 18 : V32_9600Q 19 : V32b_12000 20 : V32b_14000 26 : V34_19200 27 : V34_24000 28 : V34_28800 29 : V32t_16800 30 : V32t_19200 31 : V34_4800 32 : V34_7200 33 : V34_9600 34 : V34_14400 35 : V34_16800 36 : V34_21600 37 : V34_2640

  • APPENDIX 3: LCD MENU QUICK REFERENCE APPENDIX 3: LCD MENU QUICK REFERENCE ↓ = "ENTER” KEY ↑ = "EXIT” KEY → =“>” KEY ← =“<” KEY Card Selection = "CARD#” KEY Go to the top layer of menu tree = "HOME” KEY NMC - 16 V5.xx-11 ID=001 01Select Menu Modem Control 01 Secect Menu 3333333333333333 V34 Adapt Direct D ANS Standb

  • CHAPTER 3 : FRONT PANEL AND MENU TREE MANU RETRAIN ATO2 Force Modem redo adapting. RX BAUD = XXXX AT%S Indication of the signaling rate of received signal. For examples: RX Baud=3429 means the switching speed or number of transitions is 3429, however, one baud can be made to represent more than one bit per second. (This value is only available w

  • Data Connect V.3600UI, CHAPTER 5 : INSTRUCTION SETS Table 5-3 Result Codes (cont.) Short Long form 24 CONNECT 24000 25 CONNECT 26400 26 CONNECT 28800 27 CONNECT 32000 28 CONNECT 38400 29 CONNECT 57600 30 CONNECT 76800 31 CONNECT 115200 32 CONNECT 31200 33 CONNECT 33600 55

  • Data Connect V.3600UI, CHAPTER 1: MODEM INTRODUCTION Table 1-1A : Modem operating mode (4 wires/2wires L-L or D-L) Operating Mode MOD. Carrier Symbol rate Constellation points V.34+ 33600 V.34+ 31200 V.34 28800 V.34 26400 V.34 24000 V.34 21600 V.34 19200 V.34 16800 V.34 14400 V.34 12000 V.34 9600 V.34 7200 V.34 4800 V.34 2400 SM SM SM SM SM SM SM SM SM SM SM SM SM SM (Table 1-1c) (Table 1-1c) 4 to 1024 Depends on the combination of data rate, symbol rate and constellation expansion chosen. V.32bis 14400 T TCM 1800 2400 128 V.32bis

  • Data Connect V.3600UI, CHAPTER 5 : INSTRUCTION SETS 5.2 Dial Modifiers Table 5-2 Dial Modifiers for AT and V25bis command CODE Function Description 'T' or 't' enable tone dial 'P' or 'p' enable pulse dial '0' to '9'' A' to 'D' 'a' to 'd' '*', '#' dial digit ',' pause '!' flash hook 'W' or 'w' or ':' wait for dial tone ';' return to idle after dial '@'

Related Products and Documents (Modem):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LG 42PX3DBV Service manual lg/42px3dbv-X16.pdf 12 May 2023 28
2 THOMSON ANT 515 Operation & user’s manual thomson/ant-515-559.pdf 26 Jul 2022 16 0.51 Mb
3 Furuno 1731 MARK 3 Operator's manual furuno/1731-mark-3-33X.pdf 31 Jan 2024 83 3.74 Mb
4 KitchenAid KUIC15NLT Datasheet kitchenaid/kuic15nlt-8AD.pdf 24 Oct 2023 1
5 Harbor Freight Tools 66630 Set up and operating instructions manual harbor-freight-tools/66630-Q9M.pdf 17 Aug 2023 22 1.4 Mb
6 Briggs & Stratton 28N700 Operating & maintenance instructions briggs-stratton/28n700-7KG.pdf 14 Feb 2024 20

Similar Resources:

  • NETGEAR

    AC1750

    (5 pages)
    Performance & Use• AC1750 WiFi—450+1300 Mbps†• Cable modem download speeds up to 680 Mbps‡—16 times faster than DOCSIS® 2.0• Eliminate monthly rental fees• Works with cable Internet providers like Cablevision, Charter, Cox, Time Warner Cable®, XFINITY® & moreAC1750 WiFi Cable Modem Router Data SheetC6300PAGE 1 OF 5Over …
  • Zte

    MF633PLUS

    (45 pages)
    Check your system requirements 1. Check you have a spare USB port (USB 1.0 or 2.0) 2. You need to be running Windows 2000 / XP / Vista for a PC or OS X 10.5 and above for a Mac 3. The recommended system requirements are: CPU 1GHz Pentium or above Hard Disk 20GB or above RAM 512M or above Display 800 x 600 minimum 4. You need to have Administrator rig …
  • SMC Networks

    SMC EZ Connect SMC70032AE

    (58 pages)
    User GuideSMC70032AEEZ Connect™ADSL Ethernet Modem• Supports both G.DMT and G.lite• Interoperable with most major DSLAMs• Always-on digital connection• Bridging and routing functions• Management: SNMP, MIB II, Telnet, GUI …
  • Silex technology

    SX-10WAG

    (4 pages)
    Oct 5,2007 1. Hardware specifications/Compliance・・・・・・・・・・・・・・・・・・・・2 2.System Requirements・・・・・・・・・・・・・・・・・・・・・・・・・・・4 3.Setup ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・4 SX-10WAG Users Man …
  • Tait

    T2000-A75

    (38 pages)
    T2000-A75 ModemOperation Manual© Tait Electronics LimitedCorporate HQ: PO Box 1645, Christchurch, New Zealand.Tel: +64 3 358 3399Fax: +64 3 358 0340Web: www.taitworld.com/November 2001M2256-000-00-051 …
  • Black Box

    Speedster 288

    (45 pages)
    CUSTOMERSUPPORTINFORMATIONOrder toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOXFREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018Web site: www.blackbox.com • E-mail: [email protected] 1996MD361C-PCSpe …

Comments, Questions and Opinions: