  • DeDietrich AGC 15, 3.3 Control panel 3.3.1. Description of the keys A Temperature setting key (heating, DHW, swimming pool) B Operating mode selection key C DHW override key D Key to access the parameters reserved for the installer E Keys on which the function varies as and when selections are made F Rotary setting button: 4 Turn the rotary button to scroll through the menus or modify a value 4 Press the rotary button to access the menu selected or confirm a value modification A000866-A bar STD t 0 2 4 6 8 10 12 14 16 18 22 2420 p b AUTO x c r j M g m A B C D E F ( ' 3. Description MCA 15 - MCA 25 MCA 25/28 MI 11 23/08/2011 - 300024159-001-B

  • DeDietrich AGC 15, 2 Safety instructions and recommendations 2.1 Safety instructions DANGER If you smell gas: 1. Do not use a naked flame, do not smoke, do not operate electrical contacts or switches ( doorbell, light, motor, lift, etc..). 2. Shut off the gas supply. 3. Open the windows. 4. Evacuate the premises. 5. Call your fitter. DANGER If you smell flue gases: 1. Switch the appliance off. 2. Open the windows. 3. Evacuate the premises. 4. Call your fitter. WARNING Depending on the settings of the appliance: 4 The temperature of the flue gas conduits may exceed 60°C. 4 The temperature of the radiators may reach 85°C. 4 The temperature of the domestic hot water may reach 65°C.

  • DeDietrich AGC 15, User level - #MEASURES menu Parameter Description Unit OUTSIDE TEMP. Outside temperature °C ROOMTEMP. A (1) Room temperature of circuit A °C ROOMTEMP. B (1) Room temperature of circuit B °C ROOMTEMP. C (1) Room temperature of circuit C °C BOILER TEMP. Water temperature in the boiler °C PRESSURE Water pressure in the installation bar WATER TEMP. (1) Water temperature in the DHW tank °C INST DWH TEMP. (1) Instant hot water temperature °C STOR.TANK.TEMP (1) Water temperature in the storage tank °C DCW TEMPERATURE Domestic cold water temperature °C SWIMMING P.T.B (1) Water temperature of t

  • 4.3 Changing the settings 4.3.1. Setting the set point temperatures To set the various heating, DHW and swimming pool temperatures, proceed as follows: 1. Press the C key. 2. To select the desired parameter, turn the rotary button. 3. To modify the parameter, press the rotary button. To go back to the previous display, press the key j . 4. To modify the parameter, turn the rotary b

  • DeDietrich AGC 15, DE DIETRICH THERMIQUE S.A.S. www.dedietrich-thermique.fr FR Direction des Ventes France 57, rue de la Gare F- 67580 MERTZWILLER +33 (0)3 88 80 27 00 +33 (0)3 88 80 27 99 DE DIETRICH REMEHA GmbH www.dedietrich-remeha.de VAN MARCKE www.vanmarcke.be WALTER MEIER (Klima Schweiz) AG www.waltermeier.com DE BE CH NEUBERG S.A. www.dedietrich-heating.com LU DE DIETRICH RU Rheiner Strasse 151 D- 48282 EMSDETTEN +49 (0)25 72 / 23-5 +49 (0)25 72 / 23-102 [email protected] Weggevoerdenlaan 5 B-

  • DeDietrich AGC 15, n Operating modes p Summer mode: The heating is off. Domestic hot water continues to be produced b WINTER mode: Heating and domestic hot water working AUTO Operation in automatic mode according to the timer programme x Comfort mode: The symbol is displayed when a DAY override (comfort) is activated 4 Flashing symbol: Temporary override 4 Steady symbol: Permanent override m Reduced mode: The symbol is displayed when a NIGHT override (reduced) is activated 4 Flashing symbol: Temporary override 4 Steady symbol: Perman

  • Code Faults Cause of the fault Description Checking / solution L16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present when there should not be a flame Ignition transformer defective Gas valve defective The burner remains very hot: CO 2 too high 4 Contact the professional who takes care of maintenance of the appliance L17 VALVE FAIL PCU Problem on the gas valve Bad con

  • DeDietrich AGC 15, 4.3.2. Selecting the operating mode To select an operating mode, proceed as follows: 1. Press the MODE key. 2. To select the desired parameter, turn the rotary button. 3. To modify the parameter, press the rotary button. To go back to the previous display, press the key j . 4. To modify the parameter, turn the rotary button. 5. To confirm, press the rotary button. To cancel, press key h . Menu MODE Parameter Adjustment range Description Factory setting AUTOMATIQUE The comfort ranges are determined by the timer programme. DAY 7/7, xx:xx Comfort mode is forced until the time indicated or all the tim

  • DeDietrich AGC 15, 8 Energy savings 8.1 Energy-saving advice 4 Keep the room in which the boiler is installed well ventilated. 4 Do not block ventilation outlets. 4 Do not cover the radiators. Do not hang curtains in front of the radiators. 4 Install reflective panels behind the radiators to prevent heat losses. 4 Insulate the pipes in rooms that are not heated (cellars and lofts). 4 Close the radiators in rooms not in use. 4 Do not run hot (or cold) water pointlessly. 4 Install a water-saving shower head to save up to 40 % energy. 4 Take showers rather than baths. A bath consumes twice as much water and energy. 8.2 Recommendations The remote control is available in the following versions: 4 Wire 4 Radio

  • DeDietrich AGC 15, 4. Connect an evacuation hose to the plug located at the lowest level. Place the end of the hose in a discharge sump or in a place where the water discharged from the valve can not do any damage. 5. Open the filling/draw-off valve on the heating system. Vent the heating installation. WARNING The water may still be hot. 6. When no more water comes out of the drainage plug, close the drainage valve. T000858-A MCA 15 - MCA 25 MCA 25/28 MI 5. Checking and maintenance 23/08/2011 - 300024159-001-B 30

  • DeDietrich AGC 15, Code Faults Cause of the fault Description Checking / solution D27 PCU COM. FAIL SCU Communication failure between the SCU and PCU PCBs 4 Contact the professional who takes care of maintenance of the appliance D29 IOBL.3WV B DEF SCU Communication failure between the SCU PCB and the V3V module The V3V module is switched off The V3V module and the SCU PCB are not connected to the same live terminal The V3V module has been removed 4 Contact the professional who takes care of maintenance of the appliance D30 IOBL.3WV C DEF SCU Communication failure between the SCU PCB and the V3V module The V3V module is switched off The V3V module and the SCU PCB are not connected

  • DeDietrich AGC 15, 8. Wait until water comes out of the bleed valve and then close the bleed connection. CAUTION The water may still be hot. 9. Switch on the boiler. A vent cycle of a duration of around 3 minutes is carried out automatically. 10.After venting, check whether the pressure in the installation is still sufficient. If the water pressure is lower than 0,8 bar, more water should be added. If necessary, top up the water level in the heating system (recommended hydraulic pressure between 1,5 and 2,0 bar). ¼ See chapter: "Filling the system", page 26 11.Set t

  • DeDietrich AGC 15, User level - Menu #TIME PROGRAM Day Comfort periods / Filling enabled: P1 _______________ P2 _______________ P3 _______________ P4 _______________ TIME PROG.AUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday 4.4 Installation shutdown CAUTION Do not switch off the boiler. If the central heating system is not used for a long period, we recommend activating the HOLIDAYS mode. 4.5 Frost protection When the heating water temperature in the boiler falls by too much, the integrated protection system in the boiler starts up. This protection functions as follows: 4 If the water tempe

  • DeDietrich AGC 15, 3 Description 3.1 Operating principle 3.1.1. Gas/air setting The casing fitted to the boiler is also used as an air box. Air is sucked in by the fan and gas injected into the venturi by the fan intake. The fan rotation speed is set according to the settings parameters, the thermal energy requirement and the temperatures measured by the temperature sensors. The gas and air are mixed in the venturi. The gas/air ratio ensures that the quantities of gas and air are adjusted to each other. This provides optimum combustion on the entire output range. The gas/air mixture is fed into the burner on top of the exchanger. 3.1.2. Combustion The burner heats the heating water circulating in

  • DeDietrich AGC 15, 6. Open the disconnector valves. 7. Close the disconnector valves when the manometer indicates a pressure of 2 bar. When water is added, air gets into the heating system. Degas the installation. After the air has been vented, the water pressure can drop below the required level. Check the water pressure in the heating system. If the water pressure is lower than 0,8 bar, more water should be added. 8. After filling the installation, switch the boiler on. Filling and bleeding the installation 2 times a year should be suffic

  • DeDietrich AGC 15, 4 Operating the boiler 4.1 Commissioning the boiler 1. Check the water pressure in the installation shown on the control panel display. If the water pressure is lower than 0,8 bar, more water should be added. If necessary, top up the water level in the heating system (recommended hydraulic pressure between 1,5 and 2,0 bar). ¼ See chapter: "Filling the system", page 26 2. Open the gas valve on the boiler. 3. Turn on the boiler using the on/off switch. 4. The first time the boiler is powered up, the #LANGUAGE menu is displayed. Select the desired language by turning the

  • DeDietrich AGC 15, 1.3 General 1.3.1. Manufacturer's liability Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore delivered with [ marking and all relevant documentation. In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice. Our liability as the manufacturer may not be invoked in the following cases: 4 Failure to abide by the instructions on using the appliance. 4 Faulty or insufficient maintenance of the appliance. 4 Failure to abide by the

  • DeDietrich AGC 15, 1 Introduction 1.1 Symbols used In these instructions, various danger levels are employed to draw the user's attention to particular information. In so doing, we wish to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance. DANGER Risk of a dangerous situation causing serious physical injury. WARNING Risk of a dangerous situation causing slight physical injury. CAUTION Risk of material damage. Signals important information. ¼ Signals a referral to other instructions

  • DeDietrich AGC 15, Code Messages Description Checking / solution B08 BL.RL OPEN The RL inlet on the PCU PCB terminal block is open Parameter error 4 Contact the professional who takes care of maintenance of the appliance Bad connection 4 Contact the professional who takes care of maintenance of the appliance B09 BL.INV. L/N 4 Contact the professional who takes care of maintenance of the appliance B10 B11 BL.BL INPUT OPEN The BL inlet on the PCU PCB terminal block is open The contact connected to the BL inlet is open 4 Con

  • DeDietrich AGC 15, Code Faults Cause of the fault Description Checking / solution L09 STB BACK PCU Return temperature too high Bad connection Sensor fault 4 Contact the professional who takes care of maintenance of the appliance No water circulation 4 Vent the air in the heating system 4 Check the circulation (direction, pump, valves) 4 Check the water pressure L10 DEP-RET<MIN PCU Difference between the flow and return temperatures insufficient Bad connection Sensor fault 4 Contact the professional who takes care of maintenance of the applianc

  • 2.2 Recommendations WARNING Only qualified professionals are authorised to work on the appliance and the installation. 4 Regularly check the water pressure in the installation (minimum pressure 0,8 bar, recommended pressure between 1,5 and 2 bar). 4 Keep the appliance accessible at all times. 4 Never remove or cover labels and rating plates affixed to the appliance. Labels and rating plates must

  • DeDietrich AGC 15, 8. To define the timer ranges for the comfort mode and reduced mode: Turn the rotary button to the left until 0:00 is displayed. The first segment of the graphic bar for the timer programme flashes. 9. b : Comfort mode selection Press key b / v until the symbol b is displayed. To select a comfort time range, turn the rotary button to the right. v : Reduced mode selection Press key b / v until the symbol v is displayed. To select a reduced time range, turn the rotary button to the r

  • 3.3.2. Description of the display n Key functions > Access to the various menus ( Used to scroll through the menus ' Used to scroll through the parameters ? The symbol is displayed when help is available f Used to display the curve of the parameter selected STD Reset of the time programmes b Selection of comfort mode or selection of the days to be programmed v

  • DeDietrich AGC 15, 5. Wait around 10 minutes until the radiators are cold. 6. Bleed the radiators. Start with the lower floors. 7. Open the bleed connection using the bleed key provided whilst keeping a rag pressed against the connection. T000185-A T000854-A 3 1 4 5 2 T000217-A MCA 15 - MCA 25 MCA 25/28 MI 5. Checking and maintenance 23/08/2011 - 300024159-001-B 28

  • DeDietrich AGC 15, 4.3.3. Forcing domestic hot water production To force domestic hot water production, proceed as follows: 1. Press the r key. 2. To select the desired parameter, turn the rotary button. 3. To modify the parameter, press the rotary button. To go back to the previous display, press the key j . 4. To modify the parameter, turn the rotary button. 5. To confirm, press the rotary button. To cancel, press key h . Menu r Parameter Description Factory setting AUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme. COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (7/7). Present tim

  • 5 Checking and maintenance 5.1 General instructions The boiler does not require a lot of maintenance. Nevertheless, we recommend having the boiler inspected and serviced at regular intervals. 4 Maintenance and cleaning of the boiler must be carried out at least once a year by a qualified technician. 4 Have the flues swept at least once a year or more, depending on the regulations in force in yo

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 MTD 478 Series Professional shop manual mtd/478-series-OG4.pdf 16 Feb 2023 92
2 Sharp DV-S1S(Y) Operation manual sharp/dv-s1s-y-9RP.pdf 13 Jan 2023 22 3.79 Mb
3 American Water Heater 701022 Owner's manual american-water-heater/701022-51U.pdf 31 Jul 2023 2 0.46 Mb
4 Motorola H800 - Headset - Over-the-ear Quick start motorola/h800-headset-over-the-ear-683.pdf 07 Mar 2023 2
5 Barnes & Noble NOOK Tablet Operation & user’s manual barnes-noble/nook-tablet-FKR.pdf 21 Oct 2022 6
6 Samsung ML-1650 Service manual samsung/ml-1650-21H.pdf 23 May 2023 4

Similar Resources:

  • Buderus

    Logano G515

    (68 pages)
    Read carefully prior to installation and maintenance.Installation and Service InstructionsLow-temperature oil/gas boilerLogano G5156 720 642 624-00.1OBoilers for oil/gas-fired power burners6 720 647 208 (2014/09) US/CAWARNING: If installation, adjustment, modification, operation or maintenance of the heating system is carried out by an unqualified person, th …
  • Smith

    28HE Series

    (24 pages)
    SERIES 28HEGAS OR OIL STEAM BOILERINSTALLATION & OPERATING INSTRUCTIONSDESIGNED AND TESTED ACCORDING TO A.S.M.E. BOILER AND PRESSURE VESSEL CODE, SECTION IV FOR A MAXIMUM ALLOWABLE WORKING PRESSURE OF: 15 PSI STEAM.WARNING: If the information in this manual is not followed exactly, a fi re or explosion may result causing property damage, personal injury …
  • Potterton

    Statesman 45/50

    (56 pages)
    About the BoilerThis is a Floor Standing, Horizontally Fired, Automatic Pressure Jet Oil Boiler.The boiler can be flued conventionaly or with a kit as a balanced flue.This boiler is for use with Kerosine or Gas Oil and for use in GB & IE.About SafetyInstallation must be in accordance with the Installation & Service Instructions and the rules inforce. …
  • Baxi

    Megaflo System 15 HE A

    (56 pages)
    © Baxi Heating UK Ltd 2007Baxi System HE RangeGas Fired Wall Mounted Condensing BoilerThese instructions include the Benchmark Commissioning Checklistand should be left with the user for safe keeping.Installation & Servicing Instructions …
  • Westinghouse

    WBCETNG750

    (74 pages)
    High Mass Condensing Commercial BoilersInstallationStart-UpMaintenancePartsWarrantyWBCETNG750 / WBCETNG1000 Models**“HL” Denotes Installed High and Low Gas Pressure SwitchesThis manual must only be used by a qualied installer / service technician. Read all instructions in this manual before installing. Perform steps in the given order. Failure to do s …
  • Kiturami

    WORLD PLUS-13D

    (42 pages)
    Gas fired wall hung combination coilers ┃┃┃┃┃Technical information and Installation Servicing Instructions ModelWORLD PLUS - 13D (15.1 kW)WORLD PLUS - 16D (18.6 kW)WORLD PLUS - 20D (23.2 kW)WORLD PLUS - 25D (29.1 kW)WORLD PLUS - 30D (34.9 kW) WORLD PLUS Gas boiler……………..1페이지 …

Comments, Questions and Opinions: