Manualios.com

Care Hawk CH1000 Installation & User Manual

Care Hawk CH1000 Manual Online:

3.2, 1748 votes
Care Hawk CH1000 User Manual
Care Hawk CH1000 User Guide
Care Hawk CH1000 Online Manual

Text of Care Hawk CH1000 User Guide:

  • Care Hawk CH1000, 8 120 watt Power Amplifier (AF125) An AF125 is the external 120 Watt program/paging amplifier used with the system. This unit can be wall mounted or rack mounted. Output is 25V rms. Telephone Communications Card (TC1) The TC1 is a card that allows for the interconnection of a DA1 console to the CH1000 system, as well as connection of an analog PBX C.O. port the CH1000 system. The TC1 is installed as a plug in module on to the MI100 interface card. One TC1 is required for every DA1, and up to eight can be used with a system. When using it for PBX connectivity, a phone on the PBX system can gain access to

  • Care Hawk CH1000, 24 GND DATA_A DATA_B +12 VDC IN PORT 1-16 CONNECTOR PINOUT +12 VDC IN STATUS INDICATOR MODEL: SS16 1 2 3 4 12 11 10 9 8 16 15 14 135 6 7 CH #1 AUDIO CH #1 AUDIO CH #2 AUDIO CH #2 AUDIO GND VIDEO+ VIDEO- +12 VDC IN CH #3 AUDIO CH #3 AUDIO CH #4 AUDIO CH #4 AUDIO CALL-IN GND AUDIO AUDIO CALL-IN VIDEO- VIDEO+ PWR GND +12VDC OUT 1 8 1 8 1 8 1 8 8 1 1 8 8 1 COM 1/4W 1/2W 1W 2W 4W 25V: 8 OHM SLATE BLUE BLUE/ WHITE BLUE BLUE SLATE Buzzer Sensor Input Enabled 6 N.C. 2 Disabled N.O. P1 on CS150 4 Figure 23 HS100 Wiring Figure 24 Co

  • Care Hawk CH1000, 30 The chart below describes the jumper settings for the ports. The jumpers are found on the MI100 interface board directly behind the I/O terminal strip. General Purpose Output Port Configuration TERMINAL STRIP PIN # JP13 JP14 JP15 JP16 JP17 OUTPUT FUNCTION A - - - - Open Collector #1 1 B - - COM: Dry Contact #1 - A - - - Open Collector #2 2 B - - N.C. Dry Contact #1 - - A - - Open Collector #3 3 B - - N.O. Dry Contact #1 - - - A - Open Collector #4 4 B B COM: Dr

  • Care Hawk CH1000, 25 HS120 Wiring Connection to this station from the SS16 is done via RJ-45 plug. Connections to the audio transformer are done by crimping onto the blue pig tail wires extending from the station. Privacy functionality is supported by connecting the center tap of the 25V audio transformer to the yellow pig tail wire extending from the station. When intercom is done to this station, the audio is fed directly to the speaker as long as the handset is on-hook. As soon as the handset is taken off hook, the audio is immediately transferred to the ear piece on the handset. The toggle sw

  • Care Hawk CH1000, 10 System Accessories System Accessory Feature Summary Station Model # Station Feature CS50 CS100 CS150 HS100 HS120 Single Gang Stainless Steel Wall Plate ? ? ? ? Dual Gang Stainless Steel Wall Plate ? Can Originate Call ? ? ? ? Silicon Call Button ? ? Silicon Privacy Button ? Visual Call Assurance ? Illuminated Privacy button ? Grounded Audio Xfmr Center tap Privacy ? ? Audible Call Assurance

  • Care Hawk CH1000, 15 CH1000 Cabinet Features Figure 14 below shows an internal picture of the CH1000 system. All field wiring enters the cabinet from the bottom via dual knockout holes (7/8” and 1 ¼”). A knockout has also been provided to bring AC power into the cabinet. The door is hinged on the left side as illustrated below, and equipped with a keyed lock to prevent un- authorized access to the system hardware. Since the cabinet contains a total of 6 knockout holes, there is plenty of cable entry space for bringing field wiring into the cabinet. When bringing field wiring into the cabinet, it is recommended that DA1/phone cabling enter in a different knockout

  • Care Hawk CH1000, ii Disclaimer This manual has been validated and reviewed to be accurate for the CH1000 Series Communications System at the time of this manual’s production. However, the information contained in this document is subject to change without notice. Support for various features listed herein, is subject to the software version(s) provided with the system. CareHawk Inc makes no warranty of any kind with regard to this manual, and assumes no liability for damages incurred directly or indirectly from errors, omissions or discrep

  • Care Hawk CH1000, 29 General Purpose I/O Connections The general purpose I/O connections are found inside the CH1000 cabinet (See Figure 16 for exact location). The figure below shows the pin outs of the double row terminal strip. There are 6 general purpose inputs, and 6 open collector outputs/2 dry contact outputs (dry output contact rating of 1 amp). See next page for further details. Configuration of these ports is done through CareHawk Decisions software. Input Terminal Strip (Lower terminal strip) 1 2 3 4 5 6 GND INPUT # 1 INPUT # 6 GROUND OR COMMON INPUT # 2 INPUT # 3 INPUT # 4 INPUT # 5 GENERAL PURPOSE INPUTS Figure 29 O

  • Care Hawk CH1000, 26 CR16 Installation The CR16 is intended to be installed within the SS16 chassis. When ordering an SS16, it is possible to have it shipped from the factory pre-installed, however if required, it can be installed on site as well. The steps required to install it are as follows: • Unplug all cabling entering the SS16 from the left side of the chassis (closest side in the photo below). If power is being provided locally, the power will also need to be removed. All device port cabling does NOT need to be removed. • Using a Ph

  • Care Hawk CH1000, 22 GND DATA_A DATA_B +12 VDC IN PORT 1-16 CONNECTOR PINOUT +12 VDC IN STATUS INDICATOR MODEL: SS16 1 2 3 4 12 11 10 9 8 16 15 14 135 6 7 CH #1 AUDIO CH #1 AUDIO CH #2 AUDIO CH #2 AUDIO GND VIDEO+ VIDEO- +12 VDC IN CH #3 AUDIO CH #3 AUDIO CH #4 AUDIO CH #4 AUDIO CALL-IN GND AUDIO AUDIO CALL-IN VIDEO- VIDEO+ PWR GND +12VDC OUT 1 8 1 8 1 8 1 8 8 1 1 8 8 1 VIDEO BALUN COM 1/4W 1/2W 1W 2W 4W 25V: 8 OHM CS100 Wiring Figure 21 Connection to this station from an SS16 port can be done through an RJ-45 terminated CAT-5 cable (straight through, not cross-over cable). Connections to the audio transformer may be wired directly into a terminal strip labeled TS

  • 31 Program Inputs The program inputs are located inside the CH1000 cabinet (See Figure 16 for exact location). Below is the pin outs for the removable terminal strip. The inputs are designed for 1V RMS with a 10KO input impedance. Program sources that produce signal levels in excess of this need to be attenuated prior to connecting to the CH1000 system. Program sources can be

  • Care Hawk CH1000, 27 No Connect No Connect No Connect TIP RING 16 VAC 16 VAC No Connect DA1 PORT 1 RJ-45 JACK (1) (2) (3) (4) (8) (7) (6) (5) RJ-45 JACK PIN # No Connect No Connect No Connect TIP RING No Connect DA1 PORT(s) 2-8 RJ-45 JACK (1) (2) (3) (4) (8) (7) (6) (5) RJ-45 JACK PIN # No Connect No Connect DA1 Wiring The DA1 ports are found in the lower left corner within the CH1000 Cabinet (See Figure 16 for exact location). Up to eight DA1’s can be connected to the CH1000, and each port requires a TC1 card to be installed in the appropriate slot position (see figure 16 for TC1 slot locations). The slot # corresponds directly with the physical DA1 port number as shown on the DA1 por

  • Care Hawk CH1000, 36 Phone Commands Dial Sequence Command Dial Sequence 00# Emergency Page All 001…# Emergency Page Inclusive Zones Where … is the list of zones ( Zones: 01?64 - Must be entered as 2 digits ) 002…# Emergency Page Exclusive Zones Where … is the list of zones ( Zones: 01?64 - Must be entered as 2 digits ) 01# Page All 011…# Page Inclusive Zones Where … is the list of zones ( Zones: 01?64 - Must be entered as 2 digits ) 012…# Page Exclusive Zones Where … is the list of zones ( Zones: 01?64 - Must be entered as 2 d

  • Care Hawk CH1000, 33 APPENDIX A NOTE: Numbers 1-4 in the above illustration indicate the twisted pairs in the CAT5 cable. Pin # Wire Color for 568A Wire color for 568B 1 Green/White Orange/White 2 Green Orange 3 Orange/White Green/White 4 Blue Blue 5 Blue/White Blue/White 6 Orange Green 7 Brown/White Brown/White 8 Brown Brown

  • 23 GND DATA_A DATA_B +12 VDC IN PORT 1-16 CONNECTOR PINOUT +12 VDC IN STATUS INDICATOR MODEL: SS16 1 2 3 4 12 11 10 9 8 16 15 14 135 6 7 CH #1 AUDIO CH #1 AUDIO CH #2 AUDIO CH #2 AUDIO GND VIDEO+ VIDEO- +12 VDC IN CH #3 AUDIO CH #3 AUDIO CH #4 AUDIO CH #4 AUDIO CALL-IN GND AUDIO AUDIO CALL-IN VIDEO- VIDEO+ PWR GND +12VDC OUT 1 8 1 8 1 8 1 8 8 1 1 8 8 1 VIDEO BALUN CO

  • Care Hawk CH1000, 28 The DA1 is provided with the adapter shown below in figure 28 (model # ADA1). This adapter provides the conversion from RJ45 to RJ11 for connection to the back of the DA1 console. This adapter also breaks out the power connection to supply the first DA1 7 . Figure 28 PBX Connections The PBX ports are identical to the DA1 ports (See Figure 16 for exact location). For each PBX port that is used, one less DA1 port is available. For example if two PBX ports are to be used, only six DA1 ports are available. A maximum of eight ports are available on the CH1000 system, w

  • Care Hawk CH1000, 32 AF125 Amplifier Connections The amplifier connections are made to terminal strips found on the top inside plate in the CH1000 cabinet. Connections are as follows. Both the input cable to the amplifier, and the output cable from the amplifier should make use of shielded cable. Inside CH1000 Cabinet AF125 120W EXTERNAL AUDIO AMPLIFIER BAL. 1. COM BAL. 2. COM 25V COM CT IA1 - + SHLD + - SHLD Figure 33 Master Clock Connections The CH1000 is capable of acting as a master clock. As such it can be set up to synchronize Sapling RS- 485 based slave clocks. The RS-485 port is located inside the CH1000 cabinet

  • 20 SS16 to End Devices The SS16 allows for connection of up to 16 devices. The devices can be any of the REDy Corp standard stations listed in table 1. They can also be direct connection of 25V audio transformer/speaker, or UTP camera (utilizing a video balun). Typical installations will connect these types of devices to one of the standard room stations prior to connecting to

More Instructions:

DOWNLOAD

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 AEG COMPETENCE B4101-4 User information aeg/competence-b4101-4-346.pdf 06 Nov 2023 56 1.17 Mb
2 Sony SNCVB600 Operation & user’s manual sony/sncvb600-W46.pdf 17 Mar 2024 39 1.22 Mb
3 AUDIOLINE DECT6800 Operating instructions manual audioline/dect6800-PX7.pdf 06 Nov 2023 144 1.12 Mb
4 Sony PCGA-UMS1 Primary Operation & user’s manual sony/pcga-ums1-primary-NGU.pdf 06 Oct 2022 136 1.63 Mb
5 Furuno 1930 Operator's manual furuno/1930-N6Q.pdf 27 Apr 2023 72 2.84 Mb
6 Axis M3011 Operation & user’s manual axis/m3011-42K.pdf 04 Dec 2023 46 4.38 Mb

Similar Resources:

  • Uplink

    2550

    (4 pages)
    Uplink Remote Installation Guide for Model 2530/2550 Rev. 1 Overview With today’s busy lifestyles, more and more consumers are demanding easy remote access to their security systems. Uplink Remote is a great way to offer your customers remote control of the security systems you install, as well as providing you with additional RMR. Uplink Remote suppo …
  • SPI

    Observer 200

    (2 pages)
    “Observer 200” Series Indoor Alarm 1. Observe National Electric Code, ANSI/NFPA 70, when installing this unit to prevent moisture buildup. SPI is not responsible for damage or injury resulting from improper installation procedure. 2. Turn off power. 3. On the back of the enclosure, there is a slotted keyho …
  • ADEMCO

    Security System VISTA-15

    (132 pages)
    K3892V1 4/009,67$9,67$&16HF XULW\6\VWHP,QVWDOODWLRQDQG6HWXS*XLGH •••••••••••••••••••*®www.PDF-Zoo.com …
  • Plumis

    Automist Smartscan Hydra

    (95 pages)
    Automist Smartscan Hydra® Design, Installation, Operation and Maintenance (DIOM) Manual Version 2.00.0 The Smartscan Hydra DIOM Manual is designed to provide stakeholders with essential information regarding specification, installation, maintenance, and commissioning of the Automist fire protection device. SMARTSCAN® …
  • NTI

    ENVIROMUX Series

    (8 pages)
    1 ENVIROMUX-DI16DO(R)16 Digital Input/Output Expander Installation Manual The ENVIROMUX-DI16DO(R)16 Digital Input/Output Expander enables the connection of up to 16 additional digital sensors and output devices using just one RJ45 Sensor port on an ENVIROMUX-2D, ENVIROMUX-5D, or ENVIROMUX-16D Server Environment Monit …
  • Abus

    SECVEST

    (61 pages)
    FUMK50000W/B FUMK50010W/B BOM: 12892814 Version 1.0 DE Secvest Funk-Öffnungsmelder Installations- und Bedienungsanleitung EN Secvest Wireless Magnetic Cont Installation instructions and user manual FR Secvest Détecteur d'Ouverture sans Fil Instructions d’installation et d’utilisation NL Secvest Draadloze Magneetcontact Installa …

Comments, Questions and Opinions: