  • 288713405 28 5.4 Transfer to Maintenance By Pass Mode 40 to 200kVA This procedure should be followed when turning from normal operation to maintenance bypass. This procedure can be used for supplying temporary mains voltage to the system during the maintenance of the UPS or in case of failure. 1. Press on the DOWN button when there is “COMMAND MENU” message on t

  • inform Pyramid Plus, 288713405 22 4.4 MAIN Menu The main menu items are given at the following table you can move on main menu items by using DOWN key. Main Menu item Function STATUS MENU The status message which shows the UPS status MEASURES MENU → Enter "go to Meausures submenu" ALARMS → Enter "go to Alarms submenu" INFORMATION MENU → Enter "go to İnformation submenu" PASSWORD MENU → Enter "go to password submenu" SETTINGS MENU → Enter "go to Settings submenu&

  • inform Pyramid Plus, 288713405 45 Modem Connection TELESERVICE UPS can be controlled through a normal telephone line by means of a remote operator connected through a PC with modem device, who performs a phone call to the UPS connected number. So the operator can see all parameters and control the UPS (if permitted from SETTINGS MENU). 7.3.1 Hardware Configuration All needs for modem connection is as follows : • PC with modem • WINDOWS 98 • Available UPS control software • DUMP mode

  • inform Pyramid Plus, 288713405 11 1) Verify that the UPS’s switches are totally at “0” position. 2) Connect the AC input supply cables coming from the input mains distribution panel to the B terminals as in Fig. 3-2-c,d,e. ATTENTION!!! PLEASE BE SURE OF CORRECT PHASE SEQUENCE. If there is a phase sequence fault, A21/A39 “ROTATE PHASE” message appears on the front panel and the UPS can’t work. THE CORRESPONDING AC INPUTS OF BOTH UPS’s (U3-V3-W3) MUST BE EXACTLY OF THE SAME PHASE. 3) Connect the UPS output cables from the output terminals to the load distribution panel. ATTENTION!!! For proper load sharing during parallel operation the cables between the AC distribu

  • 288713405 16 4 4 . . F F R R O O N N T T P P A A N N E E L L 4.1 Introduction The front panel of UPS, consisting of a 2 lines alphanumeric display, 6 status lamps, plus 4 function keys, allows the complete monitoring of the UPS status. The mimic flow diagram helps to comprehend the operating status of the UPS. By using the function keys oper

  • inform Pyramid Plus, 288713405 15 3.4.4 Communication (UPS-Server) Dry relay alarm contacts or RS232 communication port can be used for communication with UPS. Users can get information about any possible alarm like “Battery Low” “Line Failure” “Load On By-pass”. The relay interface AS400 and Windows NT is an special edition for the systems. You should use ITF3 and RS330 board for the communication with the PC. For this connections there must be a dedicated serial port. ATTENTION!!! The communication cab

  • inform Pyramid Plus, 288713405 12 ATTENTION!!! Remove the battery fuses before making the connection of the battery circuit breaker during the battery installation. (Turn off into “0” (OFF) position) 5) Connect the copper earth bus, which is under the safety earth and the cables power connection. Note: The earth and the neutral connections must be done according to national rules. If the REMOTE STOP option is going to be used, you should connect the remote stop button (normally open), to the pins 4 and 5 of the remote stop connector (CN3) on t

  • inform Pyramid Plus, 288713405 5 3 3 . . I I N N S S T T A A L L L L A A T T I I O O N N Non-compliance with the installation guidelines contained in the present manual could adversely effect the working and/or reliability of the UPS. 3.1 Introduction WARNING!!! • Do not apply electrical power to the UPS equipment before the arrival of authorized service personnel. • Installation and maintenance has to be done by authorized service person only. 3.2 Unpacking The UPS is packed and enclosed in a structural cardboard carton to protect it from damage

  • inform Pyramid Plus, 288713405 2 1 1 . . S S A A F F E E T T Y Y Thank you for choosing Inform UPS Systems. This document provides all the instructions necessary for the instllation and the operation of the PYRAMID-PLUS Uninterruptible Power Supply. For the staff and the equipment safety, it is necessary for the users to fully read and understand this manual before working on this equipment. DESCRIPTION OF THE SYMBOLS ON THE UPS: DANGER DANGEROUS VOLTAGES (red-yellow) READ THE OPERATING INSTRUCTIONS (black-yellow) GROUNDING TERMINAL BLOCK (black-si

  • inform Pyramid Plus, 288713405 42 6.5 UPS Switch on Procedure in Parallel Mode: With all the switches and fuses (S1,S2, S3, S4 and S5) in “OFF” “0” position and with S6 in “NORMAL” position. Turn on the parallel connected UPS’s, UPS1 and UPS2 separately as follows: 1. Make sure that two UPS’s are properly connected for parallel operation in accordance with the diagrams given in “INSTALLATION PROCEDURES” section. 2. Turn on the S1 switch (inverter input) into “1” position. By turning on S1 you will see the following messages on the LCD panel, a. “RECTIFIER START” b. “INVERTER START” c. “STATUS NORMAL” After these messages the

  • inform Pyramid Plus, 288713405 37 Figure 6-3-a POWER CONNECTIONS OF TWO UPS’s FOR PARALLEL OPERATION (40-60-80 kVA) U V W N LOAD AC INPUT 3 PHASE+Neutral BATTERY GROUP (-) (+) (To be supplied by the customer) Neutral BATTERY GROUP (-) (+)

  • inform Pyramid Plus, 288713405 C C O O N N T T E E N N T T S S 1. SAFETY………………. ......................................................................................................... 2 2. HANDLING………………...................................................................................................... 4 3. INSTALLATION .................................................................................................................. 5 3.1 Introduction………………...................................................................................................... 5 3.2 Unpacking…………… ……….......................................

  • inform Pyramid Plus, 288713405 47 8 8 . . E E N N D D U U S S E E R R G G U U I I D D E E WARNING! There are no customer serviceable components inside. DO NOT open the cover or attempt to service the unit. High voltage may remain when the unit is shut down. Unauthorized service will finish warranty and could cause serious damage. 8.1 Maintenance The following operations are suggested to maximize the unit lifetime. The will help to ensure trouble -free operation for several years: 1. Vacuum the dust from the ventilation intake on the front panel. 2. Wipe the cover with a dump cloth. 3. Check the batteries charge with the manua

  • inform Pyramid Plus, 288713405 24 4.9 COMMAND Menu Items You can give immediate commands to UPS by using this menu. Submenu items Function 1 SOUND : ON/OFF Use for turn on/off beep alert sound. If you press ENTER key the option will change ,one press ON ,one press OFF. If the OFF option is used, sound alert is turn off but if a new different alarm is valid UPS changes de option to ON state. 2 ENTER B.TEST>432 If you press enter for 3 seconds battery test starts for 15 seconds. If battery test failes A6 B

  • inform Pyramid Plus, 288713405 48 9 9 . . L L I I M M I I T T E E D D W W A A R R R R A A N N T T Y Y Certificate of Warranty The warranty conditions are stipulated in the sales contract, if not the following points shall apply. The manufacturer exclusively guarantees his own products against any defect in construction or operation arising from faulty design, materials or workmanship according to the conditions set down below. The manufacturer, at his discretion, is entitled to adapt his product in order to comply with the warranty or re

  • inform Pyramid Plus, 288713405 4 2 2 . . H H A A N N D D L L I I N N G G NOTE: THE UPS CABINETS MUST ALWAYS BE HANDLED VERTICALLY DURING TRANSPORT. Do take care to the UPS balancing during handlings. Handling : You can either use a pallet truck or a lift truck for side handling, provided that the removable side- panel is unscrewed. PYRAMID-PLUS Battery cabinet UPS cabinet It is possible to use slings provided they are at least 1.5 m long. Suitable lifting eyes with nuts can be supplied on request. Remove the top pan

  • inform Pyramid Plus, 288713405 18 ALARM DESCRIPTION A18 BATT.CAPA.LOW If the battery charge is low this message indicates that charge period is not completed. If mains failure occurs during this message battery operating time is not valid. UPS will beep once every 15 sec. A19 BATT FAULT Battery test aborted. And batteries are not normal UPS gives beep sound whitin 15 sec You can clear this message by pressing 3 seconds to ENTER key Possible Causes: 1) Rectifier fault 2) Battery cells damaged 3) PURE battery connection A20 BOOST CHARGE Boost ch

  • inform Pyramid Plus, 288713405 41 Figure 6-4-e Switch and Fuse Positions and Signal cable connections for parallel operation (100-120-160-200 kVA) ANALOG DIGITAL

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HP BK356AA Specifications hp/bk356aa-VGL.pdf 19 Jul 2022 2 0.64 Mb
2 Haier HR-123 Operation & user’s manual haier/hr-123-8AR.pdf 13 Jan 2024 12 2.28 Mb
3 Raymarine Remote display Quick start manual raymarine/remote-display-KPX.pdf 22 Mar 2024 10
4 Black & Decker BL500 Series Use and care book black-decker/bl500-series-9V8.pdf 11 Apr 2023 4 0.51 Mb
5 Haier HWM100-99VGS Operation & user’s manual haier/hwm100-99vgs-XIS.pdf 12 Oct 2022 20 0.89 Mb
6 La Crosse Technology 513-1211 Manual  la-crosse-technology/513-1211-JK6.pdf 26 Jun 2023 2

Similar Resources:

  • Victron energy

    Pylontech US2000

    (11 pages)
    2020-11-11 06:58 1/11 Victron & Pylontech UP2500, US2000, US3000, Phantom-S & Force-L1Victron Energy - https://www.victronenergy.com/live/Victron & Pylontech US2000, US3000 andPhantom-SThe combination of Victron products with Pylontech lithium batteries has been tested and certified bythe Victron and Pylontech R&D departments.General informa …
  • Omron

    BN50T

    (110 pages)
    Uninterruptible Power Supply BN50T/BN75T/BN100T/ BN150T/BN220T/BN300T Instruction Manual BN50T/BN75T BN100T/BN150T BN220T/BN300T  This manual provides important safety-related information. Thoroughly read and understand this manual before installing and using the product.  Keep this manual in a convenient location so that you can refer to it whene …
  • Dynamode

    850VA

    (2 pages)
    DYNAMODE 850VA UPSQuick Start Guide (rev 2.0)IntroductionThe Dynamode 850 UPS is a low cost solution for electronic device protection for both Computers and other electronic sensitive devices such as Networking Devices, Multimedia and Broadcast equipment. Please take time to read the following so you can get acquainted with this device Charging the UPS for t …
  • Eaton

    RT 1250VA

    (35 pages)
    Foreword Manual instruction Thanks for purchasing our UPS, it is safe and reliable, so few maintenance is required. Read this manual carefully and completely. It includes instructions of safety installation and operation. They will help your UPS obtain the longest life and service. This manual accounts the internal working principle an …
  • socomec

    Masterys BC

    (52 pages)
    MASTERYS BC100-120 kVAInstallations- und bedienungsanleitung DEInstallation and operating manual EN Manual de instalación y uso ES Paigaldus- ja kasutusjuhend ET Asennus- ja käyttöohje FI Manuel d’installation et d’utilisation FR Manuale di installazione e uso IT Installatie– en bedieningshandleiding NLDokumentacja Techniczno-Ruchowa PLManual de ins …
  • ALLTRONIC

    SEMIS T33

    (263 pages)
    WIR SORGEN FÜR UNTERBRECHUNGSFREIEN BETRIEBSEMIS T33Online UPSManuale d’installazione ed usoInstallation and use manualInstallations und BedienungsanleitungManuel d’installation et d’utilisationManual de instalacìon y uso160 - 200 kVA …

Comments, Questions and Opinions: