Manualios.com

Adeunis RF ARF45 Operation & User’s Manual

Adeunis RF ARF45 Manual Online:

3.8, 978 votes
Adeunis RF ARF45 User Manual
Adeunis RF ARF45 User Guide
Adeunis RF ARF45 Online Manual

Text of Adeunis RF ARF45 User Guide:

  • Adeunis RF ARF45, No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject to change without notice. All trademarks mentioned in this guide are the property of their respective owner. ADEUNIS RF 283, rue Louis Néel 38920 Crolles France Phone +33 (0)4 76 92 07 77 Fax +33 (0)4 76 08 97 46 Ref. 09-08-V0-smn

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 1 Table of contents About this document ........................................................................2 Declaration of conformity ................................................................3 Overview ..........................................................................................4 Power supply ....................................................................................5 Serial link wiring ....................

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 3 Declaration of conformity Manufacturer’s name: ADEUNIS R.F. Manufacturer’s address Parc Technologique PRE ROUX IV 283 rue Louis NEEL 38920 CROLLES - FRANCE declares that the product if used and installed according to the user guide available on our web site www.adeunis-rf.com Product Name: ARF45 Product Number(s): ARF7532A Product options: Complies with the RTTE Directive 99/5/EC: EMC: conformity is proven by compliance to the harmonized standard EN 301 489 Safety: conformity to the standard EN 60950-1/2001 Radio: conformity is

  • A RF45 User Guide Ref. 09-08-V0-smn p 4 Overview THIS DOCUMENT APPLIES TO WIFI MODEM WITH FIRMWARE V 6.6.0.4 PLEASE CONTACT US FOR THE APPROPRIATE USER GUIDE IF YOU HAVE A DIFFERENT FIRMWARE VERSION. The modem converts data from a serial link into TCP frames transported through the Wifi radio standard to an access point. Data can also be received from the access point and

  • A RF45 User Guide Ref. 09-08-V0-smn p 5 The operating parameters of these modems (serial link, WIFI and LAN management…) can be modified through a terminal software using a PC serial port or a LAN telnet port. Power supply To perform wiring of these products, the bottom part of the housing (part with stuffing box) has to be opened by unscrewing the two stainless steel screws

  • A RF45 User Guide Ref. 09-08-V0-smn p 6 Serial link wiring The WIFI modem serial interface wiring is a two-step connection process: First connect the modem to a PC to set up the modem configuration, Then connect the modem to the final equipment for data transmission. Connection during serial configuration phase For the initial configuration phase, the WIFI modem has to be connect

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 7 + DC Supply PWR WLAN ACT - CTS + RTS RX TX 5 7 2 3 8 SUB-D 9 PC (DTE) Modem (DCE) Functionnality ARF 45 WIFI modem allows data transfer from a serial link over a WIFI network to an access point. The WIFI modem can be seen as a R232/WIFI gateway. Set-up Mode The modem set-up mode can be entered using a terminal software. This is the only way to configure the modem. Accessing modem set-up by serial port The modem setup can be reached

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 8 If the xxx are correct the MAC address menu is displayed. AFTER POWER-UP, NO CHARACTERS MUST BE TRANSMITTED ON THE SERIAL LINK DURING A MINIMUM DELAY OF 5 SECONDS TO ENSURE PROPER BOOT OPERATION OF THE MODEM. See chapter SETUP for the description of the configuration menus. Accessing modem set-up by telnet port The telnet set-up mode can only be entered if a minimal LAN configuration has been previously introduced by serial port setup to meet the characteristics of the LAN and WIFI access point from where the modem is accessed. This minimal configuration includes the WLAN name, the encryption mode and the associated key f

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 9 connection time out is not reached. Once internal timeout reached (the internal timeout of the modem is fixed to 5 minutes), the connection is released from the modem side and the modem is ready to receive a new incoming set-up connection. Transmission Mode The data transmission is performed through the wireless LAN using TCP-IP protocol. The modem is ready to send or receive data when it leaves its set- up phase. AFTER POWER-UP, NO CHARACTERS MUST BE TRANSMITTED

  • A RF45 User Guide Ref. 09-08-V0-smn p 10 Set-up After entering the setup mode either by telnet mode or by RS232 link, the following message appears on the terminal. MAC Address menu MAC address 00204A895D35 Software version V6.6.0.4 (090203) Press Enter for Setup Mode At this stage, press Enter within 5 seconds to enter the setup menu. The configurati

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 11 When finished, save the new configurations with 9 (Save and exit). The modem automatically reboots. WE RECOMMEND THAT YOU DO NOT ACCESS THE 2 (CHANNEL 2), 3 (EMAIL), 5 (EXPERT) AND 6 (SECURITY) MENUS BECAUSE SOME OPTIONS ARE NOT AVAILABLE FOR THIS MODEM. Server menu The following sections describe the configurable parameters within the server configuration menu. • Network mode Select the network mode. Only option 1 : wireless only is available. Network Mode (0=Wired Only 1=Wireless Only 2

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 12 The default value is N (No), indicating the gateway address has not been set. To set the gateway address, type Y. At the prompt, enter the gateway address. Set Gateway IP Address (N) ? Y Gateway IP addr (000) .(000) .(000) .(000) • Set the netmask The net mask defines the number of bits taken from the IP address that are assigned for the host part. The net mask is entered under IP address format (decimal values). Netmask: Number of Bits for Host Part (0=default) (8) The unit prompts for the number of host bits to be entered, then calculates the netmas

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 13 • Change telnet configuration password Setting the telnet configuration password prevents unauthorized access to the setup menu via a telnet connection to port 9999. Type Y and enter the password. The password must have 4 characters. Change telnet config password (N) ? Y Enter new Password: • DHCP name There are three methods for assigning DHCP names to the modem. Default DHCP name : if the DHCP name is not changed and the IP is 0.0.0.0, then the DHCP name defaults to Cxxxxxxxx where xxxxxxxx are the 8 last bytes of the MAC address of the modem coded in ASCII format. Custom DHCP name : create your own DHCP

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 14 The current value is displayed in brackets. This value does not apply for the setup mode which can only be entered at 9600 bps. Baudrate (9600) ? • I/F (interface) mode The interface (I/F) mode is a bit-coded byte entered in hexadecimal notation. The current value is displayed in brackets. In the example below 4C means : 8 bits, no parity, 1 stop. I/F Mode (4C) ? The following table displays available options : I/F mode option 7 6 5 4 3 2 1 0 RS232 0 0

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 15 • Port number The port number setting is used in TCP connection. It is the channel for connection initiated by a remote client. Packets sent to the modem with this port number are received on this channel. The port number setting is used as source port number for outgoing packets. The current value is displayed in brackets. Port No (10001) ? The following TCP ports are reserved and must not be used: 1-1024, 9999, 14000-14009, 30704 and 307

  • A RF45 User Guide Ref. 09-08-V0-smn p 16 Show IP address after RING Disable or enable the WiPort's ability to show the IP address after RING in Modem Mode. The default is Y (Yes) (shows the IP address). Show IP addr after 'RING' (Y) ? • Autoincrement source port Y (Yes) auto increment the source port. The WiPort increments the port number used wi

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 17 • Flush mode Do not change the value 00 for flush mode. FlushMode (00) ? • DisConnTime (inactivity Timeout) Use this parameter to set an inactivity timeout. The modem drops the connection if there is no activity on the serial line before the set time expires. Enter time in the format mm:ss, where mm is the number of minutes and ss is the number of seconds. DisConnTime (00:00) ? To disable the inactivity timeout, enter 00:00. Send char 1/2 Do not change the value 00 for Send char 1 and Send char 2 SendChar 1 (00) ? SendChar 2 (00) ? WLAN menu Topology Select infrastructure (ESS) mode or adh

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 18 The WLAN name is the name of the WIFI network in which the modem resides. The current value is displayed in brackets. Network name (SSID) (ARF_WIFI) ? Adhoc Network channel When adhoc is selected in the topology parameter and the modem cannot find the specified network, the modem switches to Adhoc mode using the channel value specified. Channel (11) ? Security The modem features WEP and WPA to secure all wireless communication. WPA

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 19 The Encryption prompt requests the length of the encryption key and the security strength. WEP64 uses a 40 bits/5 bytes (option 0). WEP128 uses a 104bits/13 bytes key (option 1). Select (Y) yes at the display current key prompt to show the currently configured key/passphrase. Change key permits modifying the currently configured key by selecting (Y) Yes. The key type requests whether the new key is in hexadecimal or passphrase format. Enter key prompts for

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 20 Set the group encryption type to 1 (WEP), 2 (WPA) or 3 (WPA2). The group encryption for all wireless devices communicating with the same access point must be equal to receive broadcast and multicast messages. If any of these devices are WEP only (no support for WPA) set the group encryption to WEP for all devices. Select (Y) yes at the display current key prompt to show the currently configured key/passphrase. Change key permits modifying the currently configured key by selecting (Y) Yes.

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 21 Enter Key: It is strongly recommended to use a passphrase of 20 chars or more! Encryption: 0=CCMP, 1=CCMP+TKIP, 2=CCMP+WEP, 3=TKIP, 4=TKIP+WEP (4) ? Select (Y) Yes at the Display current key prompt to show the currently configured key/passphrase Change key permits modifying the currently configured key by selecting (Y) Yes. The Key type requests whether the new key is in hexadecimal or passphrase format. Enter key prompts for the passphrase. The maximum length is 63 characters. Lantronix recommends using a passphrase of 20 characters or more for maximum security. Set the Encryption type

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 22 If the above TX Data rate is set to fixed, the selected data rate is the modem fixed transmission rate. If the above TX Data rate is set to auto, the selected data rate is the WiPort’s maximum data rate. Lower data rates allow for larger distances. It may also be required when communicating with older devices. TX Data rate 0=1, 1=2, 2=5.5, 3=11 4=18, 5=24, 6=36, 7=54 Mbps (7) ? Enable power management This allows the software to turn off the radio when expecting not to receive or transmit soon. This features reduces the power consumption of the modem. Enabling power manage

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 23 Default menu This “default” item of the menu resets some parts of “channel 1” configuration, “channel 2” configuration, “email” settings, “expert” and “security” settings to the factory default settings. The settings for IP address, gateway IP address, netmask, network mode, topology and wireless security settings remain unchanged. The specific settings modified by the “default” option are listed below. Server configuration All parameters Not changed Channel 1 configuration Baudrate 9600 I/F mode 4C (1 stop bit, no parity, 8 bi

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 24 AFTER APPLYING THIS COMMAND, THE RECOMMENDED CONFIGURATION MUST BE MANUALLY RE-ENTERED. SEE CHAPTER RECOMMENDED CONFIGURATION. “Exit without save” menu Exit the configuration mode without saving any changes and reboot. “Save and exit” menu Exit the configuration mode save all changes and reboot. All values are stored in non volatile memory. Recommanded configuration We recommend that after the default menu has been entered or for the first configuration that you

  • Adeunis RF ARF45, A RF45 User Guide Ref. 09-08-V0-smn p 25 Specifications RF Frequency range : 2.412 – 2.484 GHz Radiated RF power : + 15 dBm Sensitivity : - 82 dBm Range : 200 m in free field Standards compliance : EN 300-328 WIFI Network standard : 802.11b; 802.11g Modulation : DSSS Security : WEP 64, WEP 128, WPA-PSK, WPA2-PSK Radio data rate : Up to 54 Mbps Supported LAN Protocols : TCP-IP, DHCP, BOOTP, ICMP, ARP, UDP, SMTP, TFTP, ICMP, SNMP, Auto IP Modem interface Serial data rate : From 300 bps to 921.6 Kbps Serial ports : TxD, RxD. Flow control : RTS, CTS Set-up and configuration : Through set-up me

Related Products and Documents (Modem):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 JVC CA-MXKB1 Instructions manual jvc/ca-mxkb1-6K2.pdf 06 Nov 2023 30
2 Omron MY4H Datasheet omron/my4h-B6X.pdf 10 Nov 2023 4
3 First Texas Products Titanium Camo Owner's manual first-texas-products/titanium-camo-PT6.pdf 14 Sep 2023 10 0.78 Mb
4 T+A TW600 Operation & user’s manual t-a/tw600-QB5.pdf 22 Jun 2022 24
5 Enerco HS125KT Operating instructions and owner's manual enerco/hs125kt-687.pdf 21 Oct 2023 16 0.46 Mb
6 Arctic Cat 2015 400 Service manual arctic-cat/2015-400-2LX.pdf 14 Sep 2022 119

Similar Resources:

  • Black Box

    MDR220A

    (10 pages)
    MDR220A Wireless V.90 ModemUser’s ManualVersion 1.01000 Park Drive – Lawrence, PA 15055-1018 – (724)746-5500Web site: www.blackbox.com E-mail: [email protected] Toll Free in the US: Call 877-877-BBOX ( Outside the US call 724-746-5500) …
  • Comtech EF Data

    SDM-309B

    (240 pages)
    Comtech EF Data is an ISO 9001 Registered CompanySDM-309BSDM-309BSDM-309BSDM-309BSatellite ModemSatellite ModemSatellite ModemSatellite ModemInstallation and Operation ManualInstallation and Operation ManualInstallation and Operation ManualInstallation and Operation ManualPart Number MN/SDM309B.IOMEdition 2February 29, 1992 …
  • Redline Communications

    RedMAX SU-IIR

    (60 pages)
    70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 1 of 60 m RedMAXTM Wireless Access Subscriber Modem User Manual …
  • Patton electronics

    1193RC

    (11 pages)
    USERMANUALMODEL 1193RCG.703/G.704 to Single-modeFiber Rack Mount Modem CardPart# 07M1193RC-ADoc# 017141UARevised 05/04/01SALES OFFICE(301)975-1000TECHNICAL SUPPORT(301)975-1007http://www.patton.comAn ISO-9001CertifiedCompany …
  • SAGEMCOM

    5356

    (6 pages)
    1 GETTING CONNECTED Installation instructions for your NBN Modem Sagemcom 5356 This guide is designed to help you get started with your new modem. It relates to services being delivered over NBN FTTN connections. Please make sure you keep it in a safe place, as you may find you need to refer to it again at a later date. …
  • Radio Shack

    26-1145

    (35 pages)
    TRS-80RS-232-CInterfaceCatalogNumber26-1145—"\Radio/hackTRS-80MICROCOMPUTERSYSTEM^ JINTRODUCTION and Discussion of Digital SignalsINSTALLING and CheckoutTHEORYOFOPERATIONTERMinal Program andListingDECWRITERApplication ProgramRequired Equipment:TRS-80,Level IIwith16K RAMExpansion Interface withRS-232-C InstalledCUSTOMMANUFACTUREDINTHE USA FORRADIO SHAC …

Comments, Questions and Opinions: