  • Biamp DA28R, DA28R Distribution Amp / Router Operation Manual Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.com an affiliate of Rauland Borg Corp.

  • Biamp DA28R, 1 DA28R TABLE OF CONTENTS Front & Rear Panel Features Logic Input & Transformers Applications Specifications & Block Diagram Warranty pg. 2 pg. 3 pgs. 4 & 5 pg. 6 INTRODUCTION The DA28R is a 2-in by 8-out distribution amp/router. Each input channel accepts mic or line-level signals, and includes phantom power for condenser microphones. All outputs are electronically balanced & floating line-level, with 600 ohm drive capability. Logic inputs allow routing of each input to specific outputs via exter

  • Biamp DA28R, 2 FRONT & REAR PANEL FEATURES on DA28R 50/60 Hz ~ 27V 12 watts class 2 wiring logic inputs logic inputs output 8 output 7 output 6 output 5 output 4 output 3 output 2 output 1 CH 1 +10 trim pad +10 trim CH 1 phantom invert logic phantom invert logic CH 2 levellevellevellevellevellevellevellevel pad CH 2 DA28R BIAMP SYSTEMS Portland, Oregon an affiliate of Rauland-Borg Corp. INPUTSOUTPUTS Input Connectors (Channels 1 & 2): These plug-in barrier strips provide the balanced mic/line inputs for Channel 1 & Channel 2. Input isolation transformers (model IT-A) are available as a user installed option (see Transformers on pg.

  • 3 LOGIC INPUTS & TRANSFORMERS Logic Inputs: Logic Inputs 1~16 are on pins 1~16, and a common ground is on pins 17~25. Logic Inputs 1~8 affect routing of Channel 1 signal to Outputs 1~8, respectively. Logic Inputs 9~16 affect routing of Channel 2 signal to Outputs 1~8, respectively. Logic Inputs are triggered by being shorted to ground, usually by means of external swi

  • Biamp DA28R, 4 APPLICATIONS 50/60 Hz ~ 27V 12 watts class 2 wiring logic inputs logic inputs output 8 output 7 output 6 output 5 output 4 output 3 output 2 output 1 CH 1 +10 trim pad +10 trim CH 1 phantom invert logic phantom invert logic CH 2 levellevellevellevellevellevellevellevel pad CH 2 DA28R BIAMP SYSTEMS Portland, Oregon an affiliate of Rauland-Borg Corp. INPUTSOUTPUTS 2:50 1 COMPACT DIGITAL AUDIO EIGHT ZONES OF PAGE-OVER-MUSIC ROUTING CH 1 phantom invert logic phantom invert logic CH 2 DA28R zone paging switches to

  • 5 APPLICATIONS 50/60 Hz ~ 27V 12 watts class 2 wiring logic inputs logic inputs output 8 output 7 output 6 output 5 output 4 output 3 output 2 output 1 CH 1 +10 trim pad +10 trim CH 1 phantom invert logic phantom invert logic CH 2 levellevellevellevellevellevellevellevel pad CH 2 DA28R BIAMP SYSTEMS Portland, Oregon an affiliate of Rauland-Borg Corp. INPUTSOUTPUTS TWO INDEPEN

  • Biamp DA28R, 6 SPECIFICATIONS & BLOCK DIAGRAM Frequency Response (20Hz~20kHz): +0/-1dB Maximum Input: +24dBu THD+Noise (20Hz~20kHz): < 0.03% Maximum Output (balanced): +24dBu Noise Floor (20Hz~20kHz @ unity gain): < -75dBu Power Consumption: 10 Watts max. Maximum Gain (mic in to balanced out): 79dB Dimensions: Input Impedance (balanced): height 1.75 inches (44mm) mic input 4.3k ohms width 19 inches (483mm) line input 5.6k ohms depth 7.5 inches (190mm)

  • Biamp DA28R, WARRANTY BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the terms and conditions set forth below. 2. If you notify BIAMP during the warranty period that a BIAMP Systems product fails to comply with the warranty, BIAMP Systems will repair or replace, at BIAMP Systems' option, the non

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Caldura IM06 Operating instructions caldura/im06-938.pdf 28 Jul 2022 4
2 Buderus MCM10 Installation instructions manual buderus/mcm10-97R.pdf 10 Aug 2023 40
3 SodaStream Revolution Instruction manual sodastream/revolution-D9X.pdf 09 Dec 2022 24 7.92 Mb
4 Black & Decker SX4520 Manual  black-decker/sx4520-845.pdf 13 Feb 2024 2
5 Eiki LC-6000 Specifications eiki/lc-6000-WA6.pdf 19 Nov 2023 1 0.04 Mb
6 Healthrider H70e Elliptical Manual  healthrider/h70e-elliptical-276.pdf 21 Jul 2022 24 1.74 Mb

Similar Resources:

  • Makita

    3620

    (56 pages)
    1 GB Router INSTRUCTION MANUAL UA Фрезер ІНСТРУКЦІЯ З ЕКСПЛУАТАЦІЇ PL Frezarka górnowrzecionowa INSTRUKCJA OBSŁUGI RO Maşină de frezat verticală MANUAL DE INSTRUCŢIUNI DE Oberfräse BEDIENUNGSANLEITUNG HU Felsőmaró HASZNÁLATI KÉZIKÖNYV 3620 SK Horná fréza NÁVOD NA OBSLUHU CZ Horní frézka NÁVOD K OBSLUZE …
  • NETGEAR

    FVS328 - ProSafe VPN Firewall

    (2 pages)
    FVS328ProSafe VPN Firewall with Dial Back-up SurefireBusiness-ClassSecureThoroughlyProtectedEasy to UseFlexible &DurableDesktop PCs with FA311 network card installedDesktop PCs with FA311 network card installedServers100 Mbps10 MbpsFVS328 VPN Firewall FVS328 VPN FirewallCable/DSLmodemTelecommuterwith ProSafe VPNClient softwareTelecommuterwith ProSafe VPN …
  • Multitech

    MultiVOIP 400 MVP400

    (2 pages)
    1 of 24-Channel Voice/Fax Product UpdatePart Number: 820879005/28/99IntroductionThis product update provides the information necessary to perform a 4-channel voice/fax field upgrade to yourMultiVOIP. For example, a MultiVOIP MVP400 can be upgraded to an MVP800 by following the installationinstructions provided below. InstallationTo install the 4-Channel V …
  • Allied Telesis

    AT-AR415S

    (3 pages)
    Allied Telesis www.alliedtelesis.comDatasheet | Management SoftwareALLIEDVIEW™-EMSNetwork Device Management SoftwareAlliedView-EMS 3.11Network Device Management SoftwareEase of UseWith AlliedView-EMS, you can view details of allthe managed Allied Telesis products on yournetwork from a user-friendly, window-basedinterface. Display the physical view of a dev …
  • Cisco

    NCS 4000 Series

    (40 pages)
    Cisco Systems, Inc.www.cisco.comCisco has more than 200 offices worldwide. Addresses, phone numbers, and fax numbers are listed on the Cisco website at www.cisco.com/go/offices.Cisco Network Convergence System 4000 Series Unpacking, Moving, and Securing GuideMay 2015 …
  • Black Box

    WRT4000 SeriesWRT4001A

    (8 pages)
    BLACK BOX®Quick Start GuideSingle box solution for Internet/WAN access, VPN, firewall, Ethernet switching, and legacy protocol to IP internetworking.WRT4000 Series Cellular Wireless Routers Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0 …

Comments, Questions and Opinions: