iTrust UH11-0030L Operation & User’s Manual
|
iTrust UH11-0030L, Safety Guidelines . Prohibitions 1. As high voltage exists within UPS, no one but Avansys technician and Avansys-authorized technician should open the panel and the chassis cover. Otherwise, one may get electric shock and such situation is not covered under warranty. 2. When the UPS is purchased to supply the equipment listed below, please consult the distributor in advance on the UPS application, setting, management and maintenance, which need special consideration and design. Life support medical apparatus; Facilities such as lift which may en
iTrust UH11-0030L, Turn off the UPS and cut off the power input immediately, contact the distributor for help. UPS internal fault Abnormal noise or smell inside the UPS. 12 The UPS needs maintenance, please contact the distributor. UPS internal fault The buzzer beeps, the fault indicator shines, and the 1st, 4th fault locating indicator from the left or the inverter indicator flashes. 11 Restart the UPS after confirming that load short-circuit does not exist. UPS output short-circuit. The buzzer beeps, the fault indicator shines, and the 5th fault locating indicator from the left flashes.
iTrust UH11-0030L, 11. Please don’t open or damage the battery, as the electrolyte is harmful to skin and eye. If tainted with electrolyte, wash it off immediately with plenty of water and go to hospital for a check.
iTrust UH11-0030L, 2121208 Long backup time UPS (kg) 45454014 Standard UPS (kg) Weight 210 400 530 210 400 530 210 400 530 160 260 420 W H D (mm)Size <1500m, derating in accordance with GB/T3859.2 when it is higher than 1500m Elevation 5% 95%, non-condensing Relative humidity 40 ° C +70 ° C (without battery) 20 ° C +55 ° C (with battery) Storage temperature 0 ° C +40 ° C Operating temperature Environ mental condition UH11-0030LUH11-0020LUH11-0020LBUH11-0010L UH11-0030UH11-0020UH11-0020BUH11-0010 Model Appendix 3 Technical Specifications 49 E1-20010915-C-1.0
the UPS rated capacity, the socket capacity can be derated according to the load current. 4. As shown in Fig. 7(a) and Fig. 7(b), connect the UPS input power line to a wall socket or a distribution switchboard. Notice Don’t reversely connect the input neutral line and live line! III. Connect UPS output cable 1. Please note that the max capacity of each output socket is 1
IP21 Protection class IEC60664-1-IV, 6kV/3kA hybrid wave for 1.2/50 µ S+8/20 µ S Surge protection Conduction: EN50091-2, EN55022 Class B; Emission: EN50091-2, EN55022 Class A; Harmonic current: EN61000-3-2; Immunity: EN61000-4-2.3.4.6.8.11 Level III, EN61000-4-5 Level IV EMC CCEE GB4943-1995Safety LEDDisplay ≤ 45dB ≤ 40dB Audible noise (1m) ≤ 5msInver
iTrust UH11-0030L, heat source and direct sunlight, and better keep the air inlet/outlet free of dust. 4. The UPS is suitable for resistive-capacitive load (like computer), resistive load and micro-inductive load; it is not suitable for purely inductive load and purely capacitive load (like motor, air-conditioner and duplicator ; it can not assume half-wave rectifier load. 5. Install the UPS in environment free of dust, volatile gas, salt, and corrosive materials. 6. Don’t install it in open area. 7. To ensure the safety of the UPS and user equipment, please adopt correct power distribution: Input live line Input neutral line U P S Load L N E Doubl
iTrust UH11-0030L, A. Remove the substances blocking the vent, or widen the distance from the wall, restart the UPS after it cools down. B. Check whether the rear panel fan is blocked from running or damaged (the fan stops running). Internal overtemperature The buzzer beeps, the fault indicator shines, and the 3rd fault locating indicator from the left flashes. 9 A. Allow the battery to charge for more than 8 hours when the AC mains is normal, and then re-test the discharge time; B. The battery needs replacement, please contact the distributor. A. The battery is not
2. The loading process is the same as described in Section “Start Normal mode”. Notice In the event of overload during the loading process after starting Battery mode, immediately disconnect some loads till the overload alarm stops, otherwise, the system will stop output after a delay time. 3.2.3 Battery Management I. Battery connection test To ensure norma
iTrust UH11-0030L, 4 green lights and 1 yellow light shining indicates the UPS assumes more than 95% rated load 4 green lights shining indicates the UPS assumes 75%--95% rated load 3 green lights shining indicates the UPS assumes 55%--75% rated load 2 green lights shining indicates the UPS assumes 35%--55% rated load 1 green light shining indicates the UPS assumes 0--35% rated load When the battery is supplying load, these indicators indicate the battery backup capacity, as detailed in the following table: The yellow light shining means the battery is approaching discharge termination voltage, and t
iTrust UH11-0030L, wiring diagram User UPS Protective ground Ground bar 1. Fixation hole 2. Air breaker 3. Integrated lightning protection element 4. Ground copper bar C-class lightning protection ground Fig. 1 Connection of SPD24SZ SPD Notes: 1. It is recommended to use copper core cable with sectional area between 6 25mm² as the live line (L) and neutral line (N) of the SPD24SZ SPD, and copper core cable with sectional area 10mm² (minimally 6mm²) as the protective ground cable (PE line). For detailed installation, please refer to relevant specifications b
iTrust UH11-0030L, the UPS stops running. About 30 seconds later, the auxiliary supply shuts off, all panel indicators go off, and the fan stops running. 3.2.5 System Power-off 1. After turning off the inverter, pull off the system input plug, or place the switch of the wall socket or the distribution switchboard to OFF, all panel indicators go off, and the fan stops running (if there is a battery, a delay time of 30 seconds is needed before the fan stops). Up to now, the system is powered off. 2. If the UPS is connected to external battery, place the switch of the external battery t
iTrust UH11-0030L, please find out the reason, for instance: mains failure, battery test, operator intervention, etc. V. Function Inspection It is recommended to inspect the UPS functions once half year. 1. Press the OFF button, check whether the buzzer and LED indications are normal (see Section 3.1 Operation Mode). Please do this after confirming that the AC mains is normal and data backup has been done. 2. Press the ON/SILENCE button, check again whether the LED indications are normal and the UPS transfers to Normal mode. 3. When the inverter is in Normal mode (the inverter indicator shines), press and hold the ON/SILENCE button for 4 seconds
iTrust UH11-0030L, 50 Appendix 4 Optional Component -------------------------- 47 Appendix 3 Technical Specifications ----------------------- 43 Appendix 2 Grounding & Lightning Protection ---------------- 42 Dry Contact Communication Mode -------------------------- 41 RS-232 Communication Mode ----------------------------- 41 Appendix 1 Communication Port --------------------------- 39 Chapter 6 Service and Support ---------------------------- 36 Chapter 5 Troubleshooting --------------------------------
iTrust UH11-0030L, External battery socket /false panel INPUT Input switch Fan RS-232 Dry contact Output socket adaptor slot/false panel SNMP Mains input power line Fig. 4(b) Rear Panel of 2kVA/3kVA UPS 10 Chapter 1 Product Introduction E1-20010915-C-1.0
iTrust UH11-0030L, The system adopts high-frequency double conversion topology structure with high input power factor, wide input voltage range, and output immune from mains interference, hence the product is suitable for areas with unstable mains supply; It adopts advanced full digital control technology based on DSP to achieve high system reliability, features self-protection and fault diagnosis; It features excellent intelligent battery management, extending battery life; The panel operation interface adopts LED display, facilitating user to learn about the system operation state; Wi
iTrust UH11-0030L, INPUT BREAKER INPUT EXTERNAL BATT RS-232 DRY CONTACT INTELLGENT SLOT Exteranl battery cable O U T P U T U T U P T O Fig. 6(b) Connection of External Battery of 2kVA/3kVA UPS II. Connect UPS input cable 1. Prior to connection, make sure that the wall socket or distribution switchboard to be connected has been reliably grounded; 2. Make sure that the input mains voltage is within tolerances; 3. Make sure that the socket capacity is correct: 1kVA UPS adopts socket with capacity greater than 10A, 2kVA/3kVA UPS adopts socket with capacity great
Appendix 4 Optional Component Avansys iTrust series UPS provides the following optional components: C-class SPDSPD-24SSPD Max charge current 4A, for battery consisting of 10 12V cells in series. UH-BCH120/4Charger 10 100Ah cellsUF-B0030-100 10 65Ah cells UF-B0030-65 10 38Ah cellsUF-B0030-38 8 100Ah cellsUF-B0020B-100 8 65Ah cellsUF-B0020B-65 8 38Ah cellsUF-B0020B-38 8 24Ah cellsUF-B0020B-24
iTrust UH11-0030L, 1. Press and hold the ON/SILENCE button for about 1 second, after a beep and system self-test, the battery indicator and inverter indicator shine, as shown in Fig. 11(a) and Fig. 11(b), and the buzzer beeps every 3 seconds, indicating the UPS is operating in Battery mode. FAULT LINE BATTERY BYPASS INVERT BATTERY LOAD Fig. 11(a) LED Display of 1kVA UPS In Battery Mode OFF ON SILENCE FAULT LINE BATTERY BYPASS INVERT BATTERY LOAD Fig. 11(b) LED Display of 2kVA/3kVA UPS in Battery Mode Chapter 3 Operation 27 E1-20010915-C-1.0
iTrust UH11-0030L, OFF ON SILENCE FAULT LINE BATTERY BYPASS INVERT BATTERY LOAD Fig. 10(b) LED Display of 2kVA/3kVA UPS with Heavy Load 3. If all load indicators shine and the buzzer beeps every 0.5 second, it indicates that overload exists. In this case, some less critical loads should be disconnected. Usually it is recommended the UPS assume no more than 70% rated load so that the system operation won’t be affected by abrupt load fluctuation and the UPS lifetime can be extended. Notice If the system transfers from Normal mode to B
iTrust UH11-0030L, Publication Statement Thank you for using iTrust series UPS by Avansys Power Co., Ltd. UH11 series is the latest single-phase input single-phase output intelligent online UPS developed by Avansys incorporating years of experience in power supply development. As a world-leading standard UPS product, this series delivers excellent electrical performance, is fully compliant with safety regulations and EMC standards, features perfect intelligent monitoring and network management, and is well-shaped with beautiful appearance. Please read through this
iTrust UH11-0030L, Appendix 2 Grounding & Lightning Protection The grounding and lightning protection of low voltage power supply system is a systematic engineering, of which the grounding and lightning protection of UPS is only a part. According to relevant international, domestic and industry standards, lightning protection measures should be taken at the primary and secondary sides of the AC power transformer before the power line is introduced into the UPS machine room, and there are stringent requirements on the length and groundi
iTrust UH11-0030L, Functions: Ventilating fan for heat dissipation of UPS.Fan With the optocoupler dry contact port and monitoring software, the UPS can be monitored and controlled. Dry contact port With the standard RS-232 port and monitoring software (delivered with the UPS), the UPS can be monitored and controlled. RS-232 port Used to install SNMP (simple network management protocol) adaptor (optional component), through which the UPS can be directly connected into network to achieve UPS monitoring. SNMP adaptor slot For long backup time UPS, which has external battery, it is the input socket of the external battery; for standard UPS, which has internal battery, it is a false panel.
iTrust Adapt UPS Operation & user’s manual
Adapt |
CyberPower OL6000ERT3UD UPS Operation & user’s manual
OL6000ERT3UD |
Delta EH-10K UPS Operation & user’s manual
EH-10K |
Gamatronic Centric 50 kVA UPS Operation & user’s manual
Centric 50 kVA |
iTrust Adapt UPS Operation & user’s manual
Adapt |
Eaton RT 1250VA UPS Operation & user’s manual
RT 1250VA |
PowerWalker VI 450 LCD UPS Quick start manual
VI 450 LCD |
Staco Energy FLP-10-POPC-5-R-4Y-2Y UPS Operation & user’s manual
FLP-10-POPC-5-R-4Y-2Y |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Sandstorm | S1DTAM13 | Instruction manual | sandstorm/s1dtam13-PBY.pdf | 11 Feb 2024 | 36 | |
2 | Hitachi | KP-DE500 | Specification | hitachi/kp-de500-K22.pdf | 29 Sep 2023 | 2 | 0.28 Mb |
3 | Belson | ESI-12F | Use and care book | belson/esi-12f-WK2.pdf | 30 Nov 2023 | 2 | 0.02 Mb |
4 | IMPERIA & MONFERRINA S.p.A. | EC/NG | User and maintenance manual | imperia-monferrina-spa/ecng-U14.pdf | 26 Jul 2022 | 136 | |
5 | Polycom | AS-2000 | Configuration manual | polycom/as-2000-GZ6.pdf | 10 Sep 2023 | 6 | |
6 | Kenmore | 795.7108 | Use & care manual | kenmore/795-7108-611.pdf | 24 Nov 2022 | 36 |
APS
Back-UPS ES 725User’s Guide123Connect BatteryEquipmentPower On andInstall Software990-9219 Revision 1 7/02 Copyright © 2002 American Power Conversion Corp.All other trademarks are property of their respective owners.Surge ProtectionThese outlets provide full-time protection from surges even if the Back-UPS ES is switched OFF. Plug your printer, fax machi …
Back-UPS ES 725 BE725BB(2 pages) |
Tripp Lite
1Quick Start GuideAVRX550UA, AVRX750UA UPS Systems(Series Numbers: AG-0504, AG-0506)Not suitable for mobile applications.1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/supportCopyright © 2021 Tripp Lite. All rights reserved.This document explains the most important features of your UPS system. For additional information, download the Owner’ …
AVRX550UA(8 pages) |
Huawei
1Issue: 10Part Number: 31507659Date: 2020-03-23UPS5000-E-(650 kVA-800 kVA) Quick Guide (50 kVA Power Modules)1OverviewCopyright © Huawei Technologies Co., Ltd. 2020. All rights reserved.UPS5000-E-800K-SMUPS5000-E-800K-FMModel Weight Dimensions (H x W x D)UPS5000-E-800K-SM 1520 kg2000 mm x 2400 mm x 850 mmUPS5000-E-800K-FM 1600 kgA UPS in standard configurat …
UPS5000-E Series(15 pages) |
LSI
38176- 00BThank you for purchasing the LSI MegaRAID LiON (lithium ion) intelligent Battery Backup Unit 01 (LSIiBBU01). The LSIiBBU01 is designed for use on MegaRAID SAS RAID controllers. It protects the integrity of the cached data on a MegaRAID controller for up to 72 hours in the event of a complete AC power failure or a brief power outage.LSI provides a f …
MegaRAID iBBU01(2 pages) |
Tripp Lite
Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: G1000UBDigital UPS System - Battery backup and protection for computers, audio/video components and home theatersystems Highlights1000VA line-interactive UPS system with 8 NEMA 5-15R outletsLarge LCD status screen shows input voltage, batter …
G1000UB(4 pages) |
Phasak
ON-LINE 3P/3PPH 9283 PH 9284LEA AL MENOS ESTOSiga estrictamente todas las advertencias e instrucciones de estemanual.Antes de instalar esta unidad, lea todas las instruccionesatentamente.No utilice este SAI antes de leer atentamente toda la informaciónde seguridad y las instrucciones de uso.PELO MENOS LEIA ISTOSiga estritamente todas as advertências e inst …
ON-LINE 3P/3P(100 pages) |
Manhattan Enclosure 703253Manhattan Product User Guide: 703253 PDF Operation & user’s manual - B16V1A 703253, 4 |
T-Mobile Docking Station MyTouch SlideT-Mobile Docking Station MyTouch Slide Operation & user’s manual MyTouch Slide, 4 |
Cadillac Automobile CTSCTS (Automobile ePDF Guide, #KH2AKU) CTS, 78 |
Sharp Stereo System CD-BA1500HCD-BA1500H (Stereo System ePDF User Guide, #8JOU35) CD-BA1500H, 52 |
Lenovo Laptop T61Lenovo T61 Manual (Setup manual), @388V3H T61, 2 |
Nokia Cell Phone E60Cell Phone #J4VS72 E60, 25 |
KanexPro Media Converter SDI-MULTI2SDIPROUser Manual: KanexPro SDI-MULTI2SDIPRO (3YR4ES, Upd.25th Jan 2024) SDI-MULTI2SDIPRO, 18 |
Samsung Flat Panel TV 400DXn - SyncMaster - 40" LCD Flat Panel DisplaySamsung Flat Panel TV 400DXn - SyncMaster - 40" LCD Flat Panel Display Manual de usuario 400DXn - SyncMaster - 40" LCD Flat Panel Display, 182 |
Anritsu Measuring Instruments LMR Master S412EUser Guide: Anritsu LMR Master S412E (8BI3BQ, Upd.Sunday 31-12-2023) LMR Master S412E, 122 |
Casio Digital Camera QV-5000SXPDF Manual (@9WA8U8), Casio QV-5000SX Digital Camera (03rd Nov 2023) QV-5000SX, 19 |
Crafstman Lawn Mower 10t802Crafstman 10t802 Lawn Mower Operator's manual 10t802, 9 |
Craftsman Drill 315.101540Craftsman Product User Manual: 315.101540 PDF Operator's manual - 79RJKV 315.101540, 18 |