  • Samsung MIM-D00, E-30 Using the DMS through the Web (Continued) Function Details  Tracking is the most initial stage that a DMS recognizes the DVM indoor/outdoor units. When performing a Tracking, some information may be lost; thus, use with care. User can order the Retry of a Tracking and mange the name of devices on the Tracking information screen. (Information may be lost if ‘Tracking’ is executed. Consult the installer if possible wen executing ‘Tracking.’) Tracking     1 When pressing the ‘Tracking’ by mode button from  , the installation inform

  • Samsung MIM-D00, E-23 Using the DMS through the Web (Continued)    Select one of the three modes in the indoor unit operation (‘Switch to Fan Mode,’ ‘Set Heating Temperature to 16,’ and ‘Power OFF’)    The ‘Circulation Period’ can be set between 3 minutes and 10 minutes.    The ‘Total Number of Groups’ can be set between 2 groups to 8 groups.    Set the groups for each indoor unit. (Set the group to ‘0’ to exclude the indoor unit from circulation control.)   Click on the ‘Save’ button to complete the setup. Function Explanation  The DMS users can inquire current progress of peak power control on the Web.

  • E-22 Using the DMS through the Web (Continued) Setting the Circulation Control    Select the ‘Circulation Control’ as shown in the screen above.    Click on the ‘Edit’ button to set the priorities of each indoor unit as shown in the screen below.        MIM-Doo_IB_E_25059.indd 22 2006-03-21 ソタネト 7:34:53

  • Samsung MIM-D00, E-6 Main Function (Continued) Item Content Remark Schedule Period Starting and ending date of a schedule Exception Day Setup Set an exception day within a schedule period to ignore the schedule control Indoor unit to be applied Select indoor units to receive schedule control Event Set indoor unit operation modes - Indoor unit On time - Indoor unit Off time - Set temperature - Control mode: Heat, Cool, Dry, Fan, and Auto - Allow/Disable the use of remote controllers Both the On time and the Off

  • E-26 Using the DMS through the Web (Continued) Function Explanation  Users can inquire operation breakdowns and power usage by indoor units that is saved in the DMS. Inquire Power Distribution Result Inquiring the result      Total Indoor units (by period) 1 Select ‘Total Indoor units (by period)’ in  to check the power consumption and the rate by period f

  • E-8 Main Function (Continued)  In order to use the peak power control function in the DMS, relevant devices as shown above must be installed. (Consult the installers.) Rs 485 Demand Controller Centralized Controller Max 256 Indoors (DVM Series) Peak I/M Power Cable Centralized Controller 1) Overview  The peak power control function is used to min

  • Samsung MIM-D00, E-11 Main Function (Continued)  By sharing the peak power control information with other DMS’, several buildings can be controlled using the peak power control.  This setting consists of one master DMS and several slave DMS’ and the information of the master DMS must be set on all slave DMS’. The default DMS setting is set to master. Demand Controller Peak I/M Power board Master DMS Communication, point of contact Building A Building B Building C Slave DMS Slave DMS Slave DMS Sharing of Peak Level  Master DMS transmits the received Peak Level periodically to the connected slave DMS’ and the slave DMS performs de

  • Samsung MIM-D00, E-14 Using the DMS through the Web (Continued) Function Details  On this screen users can monitor the operation status of all indoor units and control each indoor unit. Only one selected indoor unit can be controlled. Monitoring and Control Monitoring and Control 1 The status of all indoor units can be viewed from the ‘Monitor all indoor units.’ The color of the squares represents the following meaning and the name of each indoor unit is displayed inside of squares. Gray Blue Green Red MIM-Doo_IB_E_25059.indd 14 2006-03-21 ソタネト 7:34:51

  • Samsung MIM-D00, E-28 Using the DMS through the Web (Continued) Function Explanation  The DMS users can set and view information related to the DMS system installation and operation. (The installer must complete the system environment setup when installing the DMS.) Setting and Viewing the System Environment System environment setup MIM-Doo_IB_E_25059.indd 28 2006-03-21 ソタネト 7:34:55

  • Samsung MIM-D00, E-17 Using the DMS through the Web (Continued) View Error History Function Details  Users can set, edit, and delete schedules for controlling the DVM system. Set, Run and View Schedule Using the Schedule Function   The Schedule List screen shows all current schedule information saved in the DMS. 1 On the schedule screen, a schedule can be created, edited, viewed, and deleted. 2 Press the ‘New Schedule’ button in  to create a new schedule. (Refer to Adding a Schedule) 3 Press the ‘Edit’ button in  after selecting a schedule in  to edit a set schedule. (Refer to Adding

  • Samsung MIM-D00, E-29 Using the DMS through the Web (Continued) Setting and Viewing the System Environment 1 DMS Network Information Change the set information by inquiring the existing set network information from the DMS network information and clicking the Edit button. If this information is changed, the DMS is restarted automatically. 2 Master DMS Information Master/Slave is a setting for sharing of time and peak power control information when several DMS are connected to the one system. With assigning basic DMS to the Master and remains to the Slaves, users can share Da

  • Samsung MIM-D00, E-9 Main Function (Continued) 2) Operation Mode  Peak power control runs in one of the 3 modes: ‘No Control’, ‘Priority Control Mode’, and ‘Circulation Control Mode.’  No Control: If the peak power control mode is set to ‘No Control’, peak power control will not run. The default DMS setting is set to ‘No Control’ mode.  Priority Control Mode: In Priority Control Mode, priorities are set for each indoor unit and the indoor units are controlled according to the priorities set when the peak level is received.  The operation is as follow: Input Peak Level Peak Power Control Applied Group Level 0 Peak power

  • Samsung MIM-D00, E-3 Contents General Description  INTRODUCTION OF DMS ............................................................................. 4  ADVANTAGES OF DMS SYSTEM ................................................................ 4 Main Function  INTERFACE WITH UPPER LEVEL CONTROLLER ........................................... 5  SAVE ERROR HISTORY .................................................................................. 5  SET AND RUN SCHEDULE ...................................................................

  • Samsung MIM-D00, E-13 Using the DMS through the Web Login Function Details  Login allows only authorized users to access the web page.  There is no limit on the number of users that can access the DMS at the same time, however, less than 5 users are recommended for access speed reasons. 1 Type in the ID and the password and click on the LOGIN button. 2 If the ID and the password are valid, the monitoring and control page will be displayed. 3 If the ID and the password are not matched, the LOGIN page is displayed again. 4 If the

  • Samsung MIM-D00, E-16 Using the DMS through the Web (Continued) Function Details  The DMS users can view and delete error history of the DVM system. The DMS saves up to 256 errors. View Error History 1 All error history can be checked from the ‘View Error History’ page. 2 The error history can be viewed according to date. Select the date in the list box and press the “search” button to view the error history according to the selected period. 3 The error history includes the device name, address, time when error occurred, time when error was fixed, error code,

  • E-5 Main Function Device Type Indoor Unit Indoor unit communication error Indoor unit sensor related error Other errors Outdoor Unit Outdoor unit communication error Pipe inspection error Outdoor unit sensor related error Outdoor unit related other errors Solution Products such as the Centralized Controller Solution device related communication error  Device name, address

  • Samsung MIM-D00, E-32 Terms  DMS The abbreviation of Data Management Server.  UPPER CONTROLLER It means SNET Series, a local controller of the DVM system. S-Net i and SNET III are linked to a DMS.  CENTRALIZED CONTROLLER A device that controls 16 groups of the DVM air conditioner. A central control device of a DVM system which is located between a DMS and an outdoor unit transmitter.  TRANSMITTER A data transmitter of a DVM system which is located between a central controller and an outdoor unit.  SIM The Abbreviation of Signal input Module. A device that transmits power usage of an outdoor unit by being inputted it from a power meter to a DMS.  PEAK TR

  • Samsung MIM-D00, E-19 Using the DMS through the Web (Continued) 5 When pressing the ‘Add Event’ button from the  , a new event is added. When pressing the ‘Delete Event’ button from the  after selecting a check box from the  , the selected event is deleted 6 When pressing the ‘OK’ button from the  after setting all schedule information, the schedule information is saved to the DMS. 7 When pressing the ‘Cancel’ button from the  , turn back to the schedule list screen. Editing an Existing Schedule  On the Edit

  • Samsung MIM-D00, E-2 Safety Precautions Do not attempt to install or repair this DMS by yourself.  This DMS contains no user-serviceable parts. Always consult authorized service personnel for repairs. When moving, consult authorized service personnel for disconnection and installation of the DMS. Ensure that the wall is strong enough to support the weight of the DMS. Must install the DMS with rated power supply. In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker, and consult authorized s

  • Samsung MIM-D00, E-31 Using the DMS through the Web (Continued)    Function Explanation  You can manage users to access the Web. By using this menu, you can add, edit, and delete users though the Web. User Management 1 When accessing this page, you can see the current registered user list. 2 You can add users by writing an ID, password, and explanation to the  and clicking the ‘Add’ button from the  . (There are no limits on the number of users registered.) 3 When pressing the ‘Edit’ button from the  after selecting a checkbox which you want to edit from t

  • Samsung MIM-D00, E-24 Using the DMS through the Web (Continued) Function Explanation  Users can set, inquire, and edit the information of power distribution section.  Refer to pg. 4 for more information on the Power Distribution Function. Setting and Viewing the Power Distribution Function Viewing the Error History 1 If clicking the Edit button from the  , area  is activated and users can set the desired section. Select one of possible settings which are 1 section, 2 sections, and 3 sections. 2 As shown in the above picture, one section, only Section A, is existed. It is from 00:00 to

  • Samsung MIM-D00, E-27 Using the DMS through the Web (Continued) Inquire Power Distribution Result       Individual Indoor unit (by period) 1 Select ‘Individual indoor units (by date)’ in  to check the power consumption and the running rate by date for individual indoor unit. 2 Select the indoor unit to check in  . (If the DMS is set to group mode and one group has more than two indoor units, each individual indoor unit will be checked.) 3 Select ‘watt-hour’ or ‘Running’ in  . (Power consumption or running time per date of the selected indoor unit) 4 Select the time period to check in  . 5 Press ‘Search’ in  to dispaly th

Related Products and Documents (Server):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 iBeam TE-DVR-15 Operation & user’s manual ibeam/te-dvr-15-3Y2.pdf 04 Nov 2022 8
2 Halsey Taylor 4420BF1LDBFR Owner's manual halsey-taylor/4420bf1ldbfr-3EC.pdf 22 Oct 2022 8
3 JVC KW-AVX848 Instruction manual jvc/kw-avx848-252.pdf 29 Aug 2023 215
4 Fortinet FortiController FortiController-5208 System manual fortinet/forticontroller-forticontroller-5208-936.pdf 02 Jan 2024 28 0.89 Mb
5 Black & Decker BDCD8 Original instructions manual black-decker/bdcd8-67P.pdf 12 Oct 2022 88
6 DFI G586SPB AIO Operation & user’s manual dfi/g586spb-aio-99C.pdf 05 Mar 2024 65

Similar Resources:

  • Dell

    Force10 C150

    (57 pages)
    Authors Network Enabled Solutions Team Jason Pearce, Manjesh Siddamurthy Networking Enterprise Technologist Kevin Horton Deploying the Dell Force10 MXL into a Cisco Nexus Network Environment A guide with basic examples for deploying the Dell Force10 MXL modular switch into the access layer of a Cisco Nexus network …
  • Sun Microsystems

    Netra T4 AC100

    (186 pages)
    Sun Microsystems, Inc.901 San Antonio RoadPalo Alto, CA 94303-4900 U.S.A.650-960-1300Send comments about this document to: [email protected]™T4 AC100/DC100Installation and User’s GuidePart No. 806-7334-11August 2001, Revision A …
  • Christie

    IMB-S2

    (7 pages)
    Replace the Christie IMB-S2 Instruction Sheet 1020-101329-02 Rev. 1 (06-2015)Replace the Christie IMB-S2 Instruction SheetThis document provides instructions for removing and replacing the Christie IMB-S2 in Solaria One and Solaria One+ projectors.Safety PrecautionsPrerequisites• Christie IMB-S2 replacement kit (P/N:003-103110-XX or 004-103110-XX) that inc …
  • HP

    LC2000r - NetServer - 128 MB RAM

    (4 pages)
    Scalable servers for business-critical applicationsHP NetServer LS SeriesProduct HighlightsThese high-end servers deliverthe high levels of manageability,availability, and performancerequired by business-critical environments.Designed to meet the demandingneeds of upsizers and LAN expanders, the HP NetServer LSoffers up to four-way symmetricmultiprocessing ( …
  • ClearCube

    I9422 Zero Client

    (2 pages)
    I9422 Zero Client Quick Start GuideClearCube Technology 8834 Capital of Texas Hwy N Austin, Texas 78759 voice 512 652 3500 www.clearcube.comI9422 Zero Client OverviewClearCube® I9422 Zero Clients connect to supported ClearCube PC blades containing V5x20 Dual Host cards to provide the following features:• Support for up to two independently–c …
  • NEC

    Express5800/320Fd FT

    (11 pages)
    Platinum/320 NECCare TM ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ …

Comments, Questions and Opinions: