Atek Blazer Vista 1000 Operation & User’s Manual
|
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS –This manual contains important instructions for model Blazer Vista 1000/1400/2000 VA that should be followed during installation and maintenance of the UPS and batteries. Safety – CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the
Atek Blazer Vista 1000, Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries : 1) Remove watches, rings, or other metal objects from the hand. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on the top of batteries.
Atek Blazer Vista 1000, System Description Front Panel— 1. LCD Back-Light 2. Power “ON/OFF” Switch Back Panel— 1. Communication Port(optional) 2. Cooling Fan 3. AC Output 4. Modem/Phone Line Surge Protection 5. Circuit Breaker 6. AC Input
Atek Blazer Vista 1000, Installation and Operation Installing the UPS is as easy as following the steps shown. Be aware of the Power Switch must be kept in the “ON” position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. 2. Placement Install the UPS unit in any protected environment that provides
Atek Blazer Vista 1000, 4. Computer Connection Connect one computer-related device into each of the power receptacles supplied on the back of the UPS (maximum of three devices). 5. Modem/Phone line Connection Plug incoming internet line into the “In” socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the “Out” socket at the back of the UPS. Plug the other end to the modem input socket as shown.
Atek Blazer Vista 1000, 6. Serial Cable Connection To allow for unattended system shutdown for your operating system, connect the serial cable as per diagram below. 7. Turn On/Off To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again (When Switch ON The LED lighting.). 8. LCD Display Specification The LED will always turns on when UPS works, including in off charging mode and fault mode. When LCD start to work, it will display
Atek Blazer Vista 1000, 1).When in normal mode, it will display as below. 2).When in AVR mode, it will display as below. And the mark will flicker every 1second. 3).When in battery mode, it will display as below. And the mark will flicker every 1second. Note: If I/P-V<40V input voltage will display “000” 4).When in off charging mode, it will display as below. Note: the output voltage always is displayed as “000” in off charging mode. 5).When in fault mode, it will display as below. “FAULT” character and the reason of fault only.
Atek Blazer Vista 1000, 6).Load level definition: Load LEVEL Load bar Indication 0%~25% 25%~50% 50%~75% 75%~100% 7).Battery capacity definition: Battery LEVEL Battery bar Indication Battery voltage Battery voltage Battery voltage Battery voltage 8).When over load, the mark will flicker every 1second. 9).When battery low, the mark will flicker every 1second.
Atek Blazer Vista 1000, Software Installation -- WinPower -- WinPower is brand new UPS monitoring software, which provides user-friendly interface to monitor and control your UPS. This unique software provides safely auto shutdown for multi-computer systems while power failure. With this software, users can monitor and control any UPS on the same LAN no matter how far from the UPS Installation procedure: 1. Go to the website: http://www.ups-software-download.com/winpower.htm 2. Choose the operation system you need and follow the instruction described on the website to
Atek Blazer Vista 1000, Trouble Shooting Use the table below to solve minor UPS installation or operation problems. If any abnormal situations occur that are not listed above, please call service people immediately. Symptom Possible Cause Remedy No LED display on the front panel. 1. Missing battery. 1. Charge battery up to 10 hours. 2. Battery defect. 2. Replace with the same type of battery. 3. When the Input cord isn’t electrified and Power switch is not pressed. 3. Press the power switch again or electrify the Input cord Alarm buzzer beeps continuously when AC supply is normal. Overload o
Specification MODEL 1 00 0 1400 2000 CAPACITY VA/W 1000VA/600W 1400VA/840W 2000VA/1200W INPUT Voltage 220, 230, 240VAC Voltage Range 162-290VAC 166-290VAC OUTPUT Voltage 220, 230, 240VAC Voltage Regulation (Battery Mode) 10% ±5% At load <50% Frequency 50Hz or 60Hz Frequency Regulation (Battery Mode) +/-1
CyberPower BM100 UPS Quick start manual
BM100 |
Tuncmatik Digitech Eco 1500 VA UPS Operation & user’s manual
Digitech Eco 1500 VA |
Tripp Lite Tripp Lite Rack PDUs UPS Introduction manual
Tripp Lite Rack PDUs |
Tripp Lite BCPERS300 UPS Owner's manual
BCPERS300 |
Xtreme 500VA UPS Manual
500VA |
Alpha Technologies CFR 1500 UPS Operator's manual
CFR 1500 |
Tripp Lite OMNIVSINT800 UPS Owner's manual
OMNIVSINT800 |
Atek Blazer Vista 400 VA UPS Operation & user’s manual
Blazer Vista 400 VA |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Beko | B-680TDA735 | Operating instructions manual | beko/b-680tda735-31X.pdf | 07 Jan 2023 | 11 | 0.28 Mb |
2 | Kenmore | 625.385560 | Owner's manual | kenmore/625-385560-D57.pdf | 09 Jan 2024 | 28 | |
3 | Ducati | 500 SL Desmo "Pantah" | Workshop manual | ducati/500-sl-desmo-pantah-H19.pdf | 12 Jul 2022 | 148 | |
4 | Coby | DVD-218 | Operation & user’s manual | coby/dvd-218-4O1.pdf | 24 Feb 2024 | 22 | 1.98 Mb |
5 | Benchmark | h1 | Manual | benchmark/h1-389.pdf | 29 Mar 2023 | 4 | |
6 | Pittsburgh Modular | MIDI 3 | Manual | pittsburgh-modular/midi-3-U1L.pdf | 05 Nov 2022 | 6 |
Ablerex
1 USER’S MANUAL GR1200 This manual contains important safety instructions. Please follow all instructions during installation. Read this manual thoroughly before unpacking, installing or operating. Caution: Risk of Electric Shock • The UPS contains batteries. The output outlets may be electrically live even when the UPS is disconnected from th …
GR1200(2 pages) |
HP
EH880-90945 Printed on at least 50% total recycled fiber with at least 10% post-consumer paper© 2007 Hewlett-Packard Development Company, L.P.Printed in the EUwww.hp.comHP StorageWorks D2D Backup System1 About your HP StorageWorks D2D Backup SystemThe HP StorageWorks D2D Backup System is a disk-based storage appliance that emulates up to six tape dev …
D2D(2 pages) |
CyberPower
EC350G / EC550G / EC750G EC650LCD / EC850LCD User’s Manual K01-0000277-00 Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at www.cpsww.com/registration. Registration certifies your product's warranty, confirms your ownership in the event of a product loss or theft and entitles you to …
EC750G(2 pages) |
Advice
DINU850 U P S Off Line 850VA � …
DINU850(11 pages) |
Velleman
UPS400N & UPS600N VELLEMAN 1UPS400N & UPS600N – UNINTERRUPTABLE POWER SUPPLY 1. Introduction The UPS400N and the UPS600N have a wide input voltage range and are equipped with a cold-start function to allow startup in case …
UPS400N(4 pages) |
Rittal
Rittal PMC12 UPS-User Manual 7857.433 7857.434 SINGLE PHASE TRUE ONLINE DOUBLE CONVERSION UPS SYSTEM 4,5 - 6kVA FRIEDHELM LOH GROUP R i t t a l GmbH & Co. KG Auf dem Stützelberg D – 3 5 7 4 5 H e r b o r n Deutschland Germany Email: [email protected] http://www.rittal.com Service -Tel. : (+49) - (0)2772 / 505 - 0 S …
RIMATRIX5 PMC12(31 pages) |
Apple Laptop Macintosh PowerBook 1400Macintosh PowerBook 1400 Operation & user’s manual - 2SWD98 Macintosh PowerBook 1400, 214 |
Shiro Modem UM3100#5Q3U33: UM3100 Modem Easy start manual UM3100, 16 |
kehan Kitchen Appliances C90kehan Product User Guide: C90 PDF Operation & user’s manual - JBWE3R C90, 2 |
Draper Laser Level LLK3Draper LLK3 User Guide (Instructions manual), @1P8GSP LLK3, 8 |
Field Controls Other 960524Other #CH6ZF6 960524, 1 |
Amana Dryer NGD4500VQAmana Product User Manual: NGD4500VQ PDF Installation instructions manual - 4N7SPF NGD4500VQ, 20 |
SPE Amplifier EXPERT 2K-FASPE EXPERT 2K-FA Amplifier Operation & user’s manual EXPERT 2K-FA, 57 |
Philips Monitor 150P3C150P3C Specifications - 259QE7 150P3C, 2 |
Hatco Other GRCSL-24Hatco GRCSL-24 Other Replacement parts list GRCSL-24, 4 |
Red Hat Other APPLICATION STACK 1.1 RELEASEUser Guide: Red Hat APPLICATION STACK 1.1 RELEASE (HT1I8C, Upd.Monday 02-10-2023) APPLICATION STACK 1.1 RELEASE, 30 |
AIC Server SB405-PVServer #7C3REC SB405-PV, 39 |
Kemppi Respiratory Product FA Flow ControlFA Flow Control (Respiratory Product ePDF Guide, #6NE9JP) FA Flow Control, 8 |