Manualios.com

Electronics Line iconnect Installation Manual

Electronics Line iconnect Manual Online:

3, 1842 votes
Electronics Line iconnect User Manual
Electronics Line iconnect User Guide
Electronics Line iconnect Online Manual

Text of Electronics Line iconnect User Guide:

  • Electronics Line iconnect, Appendix B: Transmitter Installation iConnect Installation Manual 105 Actions to take when Alarm Sounding In case of harmful levels of gas being detected, your detector will go into a continuous full alarm. Try to take the following necessary actions immediately or evacuate the building: • Widely open doors and windows • Disconnect electrical appliances • Avoid open fire • Repair the gas leak by a professional gas repairer Actions to take after the Problem Is Corrected Once the problem about the gas presence in the premises has been corrected, the alarm of the detector should be off. After waiting for 10 minutes, push the Test butt

  • Electronics Line iconnect, Appendix B: Transmitter Installation iConnect Installation Manual 102 Registration Procedure The EL-4727 keypad must identify itself to the system receiver. This is done by registering the keypad to the iConnect Control System as follows: 1. Release the mounting bracket. 2. Open the battery compartment and insert the batteries. Pay attention to the correct polarity. 3. Set the system to registration mode • Go to the main menu and select [9]>[1]>[3] (Programming > Devices > Keypads) • Select a keypad (1-4) 4. Press the key

  • Electronics Line iconnect, Electronics Line 3000 Ltd. Limited Warranty EL and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product. Sellers' obligation and liability under this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any pro

  • Electronics Line iconnect, Appendix C: Web User Application iConnect Installation Manual 124 Options Available from Main Page Arm/Disarm Figure C- 4: Arm/Disarm Page You can arm and disarm the system using the Arm/Disarm drop-down box (upper-right part of the page) or using the buttons in the System Operation Area. The Web Application allows you to arm and disarm your system via the Web Application using any of the available arming methods. It is important to note that when you arm using the Web application, the system is armed with the programmed delay. 1. On the Status Bar below on the page you can see the current status of the system (in our example it is Disarmed and Sys

  • Electronics Line iconnect, iv 13. System Initialization ................................................................................................................... 73 13.1. Initialization ................................................................................................................................... 73 13.2. Default Program Restore ................................................................................................................. 73 13.3. Clear User Codes ............................................................................................................................ 73 13.4. Clear Wireless Transmitters .................................

  • Electronics Line iconnect, Appendix B: Transmitter Installation iConnect Installation Manual 112 Installation Procedure After the siren has been registered mount the unit as follows: 1. Place the back cover in position against the wall and mark the upper and lower mounting holes. 2. Install wall anchors in the appropriate positions. 3. Attach the back cover to the wall using supplied screws. Mounting Bracket Tamper Protection Screw Figure B- 54: Attaching the mounting bracket 4. Mount the siren to the mounting bracket by turning the siren clockwise. 5. Secure the captive locking screw. Testing the Siren Once the siren has been registered test the unit according to

  • Electronics Line iconnect, 9 System Options iConnect Installation Manual 53 9.17. Standard Type By choosing one of the existing security standards you can change the Control System behavior accordingly. To set the standard type: 1. From the Programming menu, select System Options, Standard Type [9417]. 2. Select Regular, EN-50131 or Skafor. 9.17.1. EN-50131 Standard Type Settings the Standard type to EN-50131 changes some of the Control System settings as described below. Arm Prevention for EN-50131 The s

  • Electronics Line iconnect, 2 System Installation iConnect Installation Manual 10 2.2.5. Step 4 – Testing the Chosen Mounting Location Once all of the transmitters are registered, it is recommended that you test the chosen mounting locations before permanently mounting the Control System and wireless devices. You can test the transmitter signal strength using the Test features. To test transmitter signal strength: 1. Press ' √ʹ. 2. Enter your Installer code. 3. Enter [7042] (Service, Transmitters, TX Test) to initiate TX T

  • Electronics Line iconnect, 10 Communications iConnect Installation Manual 55 10. Communications This section explains how to determine the way the Control System communicates via the GPRS, GSM, Ethernet and PSTN modules to the Central Station and to the user. 10.1. System Reporting The Control System supports six report accounts for central station and user reporting. Each account has its own telephone number and communications options. The first account is always primary, every other account (that is not a voice report) may be chosen as primary or backup. Each primary account may have one, several, or no backup accounts at all. The order of c

  • Electronics Line iconnect, Appendix B: Transmitter Installation iConnect Installation Manual 97 Red Indicator When the red LED indicator flashes once in 30 seconds, it indicates the detector is under normal operation. When the red LED flashes very frequently and an audible alarm sounds simultaneously, it indicates that the detector senses smoke. The red LED behaves according to one of the following set modes: Mode 1: The red LED indicator will not reset automatically at the end of an alarm event.

  • 4 Advanced System Operation iConnect Installation Manual 22 Code 29: Telecontrol Code The Telecontrol code is designed to enable the user to perform a number of tasks via their telephone using DTMF commands. Using this code, the user can call their system to arm and disarm, turn on and off Home automation units, activate and deactivate the P

  • Electronics Line iconnect, Appendix B: Transmitter Installation iConnect Installation Manual 113 Outdoor Siren and Strobe (EL-4726T) The EL-4726T is a 2-Way Wireless Outdoor Siren Strobe for use with the iConnect Control System. In the event of an alarm the control system activates the siren and strobe. The Wireless Siren is sounded until the end of the control-system- programmed siren cutoff. After the siren cutoff has expired, the strobe continues to flash until the system is disarmed. Location of Siren Strobe Consider the following before mounting the siren strobe: • Choose a suitable m

  • 9 System Options iConnect Installation Manual 54 9.18. Battery Type The battery type must be defined according to the battery supplied with the system (for example, if the battery sticker reads 1500 mAh, choose 1.5 Ah, if 3000 mAh, choose 3.0 Ah). To program the battery type: 1. From the Programming menu, select System Options, Battery Type [9418]. 2. Select the battery typ

  • Appendix C: Web User Application iConnect Installation Manual 129 History The History page enables you to view the system’s event log. The events are arranged in a table that offers the advantage of allowing you to view a large number of events at once. In addition to viewing the event log, you may also save the log to a file (HTML, PDF or RTF) or p

  • Electronics Line iconnect, Appendix B: Transmitter Installation iConnect Installation Manual 99 Registration Procedure The keyfob must identify itself to the iConnect Control System as follows: 1. Set the system to registration mode. • Go to the main menu and select [9]>[1]>[2] (Programming > Devices > Keyfobs) • Select a Keyfob (1-19) and press '√ʹ. 2. Press one of the buttons on the Keyfob, making sure that the Keyfob’s green LED lights up when the button is pressed. A flashing red LED indicates a communication problem between the Keyfob an

  • Electronics Line iconnect, 5 Telecontrol and Two-Way Audio iConnect Installation Manual 30 During the TWA session, you can adjust the speaker volume using the arrow buttons. o Press "3" to fully arm the system. o Press "4XX" to turn HA unit #XX ON. o Press "430" to activate PGM output (Unit 30/31) o Press "5XX" to turn HA unit #XX OFF. o Press "530" to deactivate PGM output (Unit 30/31) o Press "6" to disarm the system. o Press "9" to cancel the siren. The Arm/Disarm, Home Automation, PGM on/off, and Siren canceling can al

  • Electronics Line iconnect, Appendix B: Transmitter Installation iConnect Installation Manual 92 Table B- 2: LED Sensitivity Level (EL-4607) LED Sensitivity Level Red Under-sensitive indication Green Normal sensitivity (recommended) Orange Over-sensitive indication 2. If required, adjust the Sensitivity parameter. 3. Repeat the sensitivity test until you achieve the required sensitivity level. 4. After you have adjusted the Sensitivity parameter, repeat the test once more. 5. Close the front cover of the detector. Deleting a Vibration Detector To delete a vibration detector from the system: 1. Set the system to Delete mode.

  • Electronics Line iconnect, 3 Basic System Operation iConnect Installation Manual 17 3.6.3. Full Arming Full arming is designed for when the occupant vacates the premises. To fully arm the system using the front panel keypad or Wireless LCD Keypad: 1. Check if the system is ready to arm. 2. Press the Full arming key on the keypad. 3. If One-Key Arming is disabled, enter your user code. 3.6.4. Part Arming Part arming is designed for when the occupant intends to remain inside one part of the premises and secure another part. To partially ar

  • Electronics Line iconnect, 3 Basic System Operation iConnect Installation Manual 15 Table 3-5: System Status Item Description ZONES IN ALARM Zones have been violated. TAMPER ALARM The system has been tampered with. 56 TO EXIT The exit delay is counting down (56 seconds remaining). 11 TO DISARM The entry delay is counting down (11 seconds remaining). SYSTEM NOT READY The system is not ready to arm, check that all doors and windows are closed. KEYPAD LOCKED Five unsuccessful attempts were made to enter a user code; the keypad is locked for 30 minutes. SYSTEM TROUBLE A trouble condition has been detected, press  for further details. 3.5. Aud

  • Electronics Line iconnect, 1 Introduction iConnect Installation Manual 6 1. Power-line terminal connections to Main Board (1 - Neutral; 2 - Live) 2. Fuse 3. LED Indicator 4. Flash programming connector 5. Interface connector to Main Board 1. External PLI connector 2. LED indicator 3. Flash programming connector 4. Interface connector to Main Board Figure 1-5: Home Automation Module (Internal PLI Module) Figure 1-6: Home Automation Module (External PLI Module) For external X10 PLI, we recommend to use

  • 5 Telecontrol and Two-Way Audio iConnect Installation Manual 32 5.2.4. TWA Follow-Me The TWA Follow-Me feature is designed to establish a Two-Way Audio connection with the user in the event of an alarm. For this feature to function, the account’s protocol must be defined as TWA Follow-Me. The sequence for a Two-Way Audio Follow-Me call is as follows: 1. An alarm occu

  • Electronics Line iconnect, Appendix C: Web User Application iConnect Installation Manual 127 Change Appearance On The Main Page menu, click Settings then Change Appearance to change the color scheme of your account. Figure C- 10: Change Appearance Page Alerts The Alerts page allows you to enter the details of contacts you wish to be informed when events occur in your system. For example, you can enter your own email address and/or cellular phone number so that you will receive email or SMS notific

  • Electronics Line iconnect, 10 Communications iConnect Installation Manual 66 System Trouble [#5] o Battery Low o Transmitter Low Battery o AC Loss o Media Loss o Device Trouble o Communication Trouble o Transmitter Out of Synch. o Control System Transmitter Out of Synch. o Supervision Loss o Zone Trouble o FM Jamming To enable/disable the vocal message for an event group: 1. From the Programming menu, select Communications, VM Event Opt. [956]. 2. Select an event group. 3. Select Enabled or Disable

Related Products and Documents (Toy):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Coolzone CZ55583 Installation and operating instructions manual coolzone/cz55583-7F4.pdf 06 Mar 2024 16
2 Electrolux 730533 Brochure & specs electrolux/730533-4V8.pdf 20 Nov 2023 2 0.13 Mb
3 Denso 4D56 Service manual denso/4d56-96W.pdf 18 Jul 2023 52
4 Craftsman 917.388512 Owner's manual craftsman/917-388512-GWH.pdf 01 Aug 2022 40
5 Genius LOOK 312P Manual  genius/look-312p-4CJ.pdf 04 Aug 2022 20 0.91 Mb
6 Asus TV Box Operation & user’s manual asus/tv-box-OH5.pdf 20 Sep 2022 23 0.6 Mb

Similar Resources:

  • REVELL

    KIT 1368

    (2 pages)
    KIT 1368 85136810200F-16 FIGHTING FALCONRevell Inc Elk Grove Village, IL. Copyright © 2011. All rights reserved.READ THIS BEFORE YOU BEGIN* Clear a space to work on.* Study the assembly drawings before you begin.* Each plastic part is identified by a part number.* This kit may be snapped together but parts may be cemented if you prefer.* Trim to remo …
  • skyangel

    DHC

    (15 pages)
    Assembly and Operating Manual DHC Specification: *Length: 26-2/5"(670mm) *Wing Span: 39-2/5"(1000MM) *Flying Weight: 21-9/10 oz .(620g) …
  • Skippy Buddy

    Panter 55cm

    (3 pages)
    Instruction manual / Handleiding / Mode d’emploi / Anleitung Skippy Buddy Panter 55cmArt.no. 2001354 Van der Meulen, Lorentzstraat 23, 8606 JP Sneek NL Instructies:Lees eerst de gebruiksaanwijzing en volg deze op. Bewaar deze om later te kunnen raadplegen.Houd de skippybal op kamertemperatuur voor het pompen. Pomp de bal op tot de gewenste groot-te: max. 5 …
  • Air Hogs

    Havoc Heli

    (4 pages)
    Step 1:Take the tail between fingers.Step 2:Twist tail anti clockwise for about 30°.Step 3:Release.Step 1:Take the tail between fingers.Step 2:Twist tail clockwise for about 30°.Step 3:Release. ii) If the helicopter takes too much backward speed by itselfDo not touch the running propeller!Do not play above someone’s head!Adult supervision is required!CH …
  • myToys

    11389822

    (5 pages)
    LauflernwagenActivity WalkerDE: Bitte lesen Sie vor Gebrauch sorgfältig die Bedienungsanleitung.EN: Please read the instruction manual carefully before use.AufbauanleitungAssembly Instructions …
  • Eduard

    MiG-25RBT

    (6 pages)
    detail set for 1/72 ICM kit • sada detailů pro stavebnici 1/72 ICM1/673 649REMOVEODSTRANITOPTIONVOLBAREPLACENAHRADITBENDOHNOUTGRINDOBROUSITSYMETRICAL ASSEMBLYSYMETRICKÁ MONTÁŽDRILL HOLEVRTAT OTVORAPPLY EXPRESS MASK AND PAINT BEFORE GLUINGPOUŽÍT EXPRESS MASK NABARVIT PRED SLEPENÍMCOLORED ETCHED PARTSLEPTANÉ BAREVNÉ DÍLYETCHED PARTSLEPTANÉ NEBAREV …

Comments, Questions and Opinions: