  • International Refrigeration Products MZG409HP16230EA, System Configuration Options Quad Zone MZG434HP16230CA, 34MH46ZOGX (2 to 4 indoor units) Note: 1. Do not mismatch or connect to an outdoor unit other than the designed matched system. 2. This system must be used with a minimum of two indoor units (evaporators). 2 INDOOR UNITS 3 INDOOR UNITS 4 INDOOR UNITS 9K + 9K 9K + 9K + 9K 9K + 9K + 9K + 9K 9K + 12k 9K + 9K + 12K 9K + 9K + 9K + 12K 12K + 12K 9K + 12K + 12K 9K + 18K 9K + 9K + 18K 12K + 18K 9K + 12k + 18K 12K + 12K + 18K Dual Zone MZG424HP16230CA, 24MH46ZOGX (2 indoor units) Note: 1.Do not mismatch or connect to an outdoor unit other than the designed matched system. 2.

  • International Refrigeration Products MZG409HP16230EA, 950-0153 - 31 - June 17, 2010 WARRANTY INTERNATIONAL REFRIGERATION PRODUCTS warrants the accompanying split air conditioner or heat pump system to be free of defects in material and workmanship for the applications specified in the operation manual and installation manual for a period of one (1) year on parts and five (5) years on compressor, valid from the date of original retail purchase in the United States or Canada. Labo

  • International Refrigeration Products MZG409HP16230EA, Line set length Locate the Indoor and Outdoor units as close together as possible. Line set height cannot exceed specifications. Installation Notes: 1. The maximum total line set length must not exceed 229 feet for all units using the 34K condenser (Quad). The maximum total line set length for the 24K condenser (Dual) is 65.6 feet. 2. Quad Zone models MZG434HP16230CA, 34MH46ZOGX are designed to have two to four indoor units. Dual Zone models MZG424HP16230CA, 24MH46ZOGX are designed to run with

  • International Refrigeration Products MZG409HP16230EA, 7. Hang the Indoor Units Once lines are straight, carefully slide the ends of line set out through the wall sleeve. Hook the indoor unit onto the top clips of the wall plate. Carefully lower the bottom portion of the indoor unit towards the wall, snapping it into the clips at the bottom of the unit. See Figure 4. If using the left rear exit run lines from outside to indoor unit. Form line set to mate to indoor unit stubs and connect prior to mounting to indoor unit. If necessary run lines along inside wall and carefully r

  • International Refrigeration Products MZG409HP16230EA, HIGH EFFICIENCY SERIES MINI-SPLIT QUAD AND DUAL ZONES INSTALLATION MANUAL FOR THERMAL ZONE MODELS MZG409HP16230EA Evaporator MZG412HP16230EA Evaporator MZG418HP16230EA Evaporator MZG434HP16230CA Condenser MZG424HP16230CA Condenser FOR SEA BREEZE MODELS 9MH46ZIGX Evaporator 12MH46ZIGX Evaporator 18MH46ZIGX Evaporator 34MH46ZOGX Condenser 24MH46ZOGX Condenser 950-0153 June 17, 2010

  • International Refrigeration Products MZG409HP16230EA, 950-0153 - 4 - June 17, 2010 PARTS INCLUDED WITH UNIT Indoor unit Outdoor Unit  Wall Bracket  Drain Fitting  Remote Control  Installation Manual  Batteries for Remote Control (2 AAA)  Remote Control Holder • Adapter - Dual Zone requires 1/2"F to 3/8”M (9510198) with 9K indoor unit. Quad Zone requires 3/8”F to 1/2"M (9510197) with 18K and/or 12K indoor unit(s). • Drain Tubing 24 ft. �

  • International Refrigeration Products MZG409HP16230EA, 950-0153 - 21 - June 17, 2010 Ductless Mini-Split Systems (Quad Zone) Outdoor Unit [TZ] 241-0034-C MZG434HP16230CA Model Number [SB] 241-1034-C 34MH46ZOGX Rated Voltage & Frequency and Phase 208-230 / 1PH Circuit Breaker Size (A) 40 Total Current (RLA) cooling 20.5 / 20.9 A Total Current (RLA) heating

  • International Refrigeration Products MZG409HP16230EA, Typical Electrical Wiring for Quad Unit (Dual Zone connection will not use units “C” and “D” connections.) Figure 15 950-0153 - 14 - June 17, 2010

  • International Refrigeration Products MZG409HP16230EA, TABLE OF CONTENTS Installation Steps 3 Notes to Installer 3 Parts Included with Indoor Unit 4 Installer Supplied Parts 4 Condensate Pump 4 Decorative Channel 5 Wall Brackets 5 Installation Considerations 5 General Information 5 System Configuration Options 6 Select Locations for Indoor Unit 6 Select Locations for Outdoor Unit 6 Line Set Length 7 Indoor Unit (Evaporator) installation 7 Outdoor Unit (Condenser) installation 10 Connecting Line Set 11 Electrical Connection – Notes 13 Connect the Cable to the Outdoor Unit – Notes 13 Typical Electrical Wiring Connections 14 Connect the Cable to the Indoor Un

  • 950-0153 - 13 - June 17, 2010 ELECTRICAL CONNECTION WARNING! Improper wiring between the inside units and the outside unit can cause serious damage to the system, and the risk of personal inju

  • International Refrigeration Products MZG409HP16230EA, Dual Zone 950-0153 - 26 - June 17, 2010 D101 Definition D102 Definition D103 Definition 1 Blink Compressor runs 1 Blink A unit communication malfunction (cannot receive correct data within 3 mins.) 1 Blink B unit communication malfunction (cannot receive correct data within 3 mins.) 2 Blinks Unit stop for compressor high pressure protection 2 Blinks A unit indoor sensor malfunction 2 Blinks B unit indoor sensor malfunction 3 Blinks

  • International Refrigeration Products MZG409HP16230EA, High Efficiency Indoor Unit Thermal Zone Models 241-0009-E MZG409HP16230EA 241-0012-E MZG412HP16230EA 241-0018-E MZG418HP16230EA Sea Breeze Models 241-1009-E 9MH46ZIGX 241-1012-E 12MH46ZIGX 241-1018-E 18MH46ZIGX Rated Voltage & Frequency 208-230 / 1PH 208-230 / 1PH 208-230 / 1PH Total Input Current (A) 0.17 0.17 0.278 Cooling BTU 9000 12000 18000 Heating BTU 10000 13500 19500 Performance & Electrical Dehumidifying Volume (pt/hr) 1.7 2.5 5.3 Output (W) 10 10 20 Fan Motor RLA (A) 0.17

  • International Refrigeration Products MZG409HP16230EA, 950-0153 - 19 - June 17, 2010 START UP TESTING Preparation 1. Double check that all wiring has been properly connected. 2. Check that tubing has been properly connected and ensure the suction and liquid side service valves are fully open. 3. Review remote control functions in the Operators manual. Operational Test Note: The cooling test may be performed if the outdoor temperature is between 41 ºF to 118 ºF. The heating test may

  • 950-0153 - 20 - June 17, 2010 Ductless Mini-Split Systems (Dual Zone) Outdoor Unit [TZ] 241-0024-C MZG424HP16230CA Model Number [SB] 241-1024-C 24MH46ZOGX Rated Voltage & Frequency a

  • International Refrigeration Products MZG409HP16230EA, Quad Zone D101 / red Malfunction D102 / yel Malfunction D103 / grn Malfunction 1 Blink Compressor runs 1 Blink Frequency drop for exhaust protection 1 Blink Frequency limit for exhaust protection 2 Blinks Unit stop for compressor high pressure protection 2 Blinks Frequency drop for cooling overload 2 Blinks Frequency limit for cooling overload 3 Blinks Unit stop for air exhaust protection 3 Blinks Frequency drop for over current protection 3 Blinks Frequency limit for over current protection 4 Blinks Unit stopped for communication malfucntio

  • International Refrigeration Products MZG409HP16230EA, Dual Zone PC Board Layout AP2-PFC Module AP3-Drive Board AP1-Main Board 950-0153 - 29 - June 17, 2010

  • International Refrigeration Products MZG409HP16230EA, Torque wrenc h Spanner Flare nut Joint Connection pipe Tightening Torque Table: Tightening Torque Table 1/4" 11-15 ft. lbs 3/8" 23-26 ft. lbs 1/2" 37-41 ft. lbs Figure 9 Vinyl tape Connection pipe (heatinsulation) Indoor unit pipin Bind the s together so that there is no gap pipe . Overlap the insulation Figure 11 Figure 12 Suction Line Liquid Line Condensation Drain Control cable Figure 13 Figure 10 5. Verify that the proper line set is being connected to the intended port of the outdoor unit. Connect the line sets to their approp

  • CONNECTING LINE SET CAUTION! IMPROPER CONNECTION OF THE LINE SETS WILL RESULT IN IMPROPER OPERATION OF THE SYSTEM. MARK EACH LINE SET AND WIRING FOR IDENTIFICATION. ENSURE THAT THE WIRING AND THE LINE SETS ARE ROUTED TO THE PROPER INDOOR ZONE. The Dual Zone uses a 1/2"F to 3/8”M adaptor for the 9K unit. The Quad Zone uses a 3/8”F to 1/2"M adaptor for 18K

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 JVC LT32A200 - 32" LCD TV Operation & user’s manual jvc/lt32a200-32-lcd-tv-245.pdf 13 Aug 2023 40
2 GE Deluxe 45117 Operation & user’s manual jasco/deluxe-45117-52M.pdf 17 Dec 2023 33
3 Crestron RACK2 Operation manual crestron/rack2-Y6H.pdf 09 Oct 2022 52 1.78 Mb
4 Omnimount Gemini 1 Instruction manual omnimount/gemini-1-R9U.pdf 18 Oct 2022 20
5 F-SECURE PSB Getting started manual f-secure/psb-OQ3.pdf 08 Jul 2023 18 0.38 Mb
6 Ubisys IEEE 802.15.4 usb stic with wireshark firmware Reference manual ubisys/ieee-802-15-4-usb-stic-with-wireshark-firmware-Y98.pdf 15 Aug 2023 30

Similar Resources:

  • LG

    Single "A"

    (92 pages)
    Single "A" Air ConditionerSVC MANUAL(General)MODEL : Single "A"-Inverter TypeCAUTIONBefore Servicing the unit, read the safety precautions in General SVC manual.Only for authorized service personnel.Internal Use Onlyhttp://biz.lgservice.com …
  • Daikin

    Altherma 3 R F

    (44 pages)
    https://daikintechnicaldatahub.euInstallation manualDaikin Altherma 3 R FEnglishInstallation manualDaikin Altherma 3 R FEBVZ16S18DJ6VEBVZ16S23DJ6VEBVZ16S18DJ9WEBVZ16S23DJ9W …
  • ZALMAN

    ZM-GWB2

    (7 pages)
    Model : ZM-GWB2VGA Water BlockPlease visit our website and watch the ZM-GWB2 installation video for easy installation.※ Please read this manual throughly before installation. ※ The specifications of this product and its components may change without prior notice toimprove performance.http://www.zalman.co.kr http://www.zalmanusa.comUser’’s ManualU …
  • LG

    UU21WH

    (35 pages)
    ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCHLGAir ConditionerINSTALLATION MANUALLGType: High COP Inverterwebsite http://www.lgservice.comIMPORTANT• Please read this installation manual completely before installing the product.• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.• Please reta …
  • Daikin

    CTXA15A2V1BW

    (16 pages)
    Installation manualDaikin room air conditionerEnglishInstallation manualDaikin room air conditionerCTXA15A2V1BWFTXA20A2V1BWFTXA25A2V1BWFTXA35A2V1BWFTXA42A2V1BWFTXA50A2V1BWCTXA15A2V1BSFTXA20A2V1BSFTXA25A2V1BSFTXA35A2V1BSFTXA42A2V1BSFTXA50A2V1BSCTXA15A2V1BTFTXA20A2V1BTFTXA25A2V1BTFTXA35A2V1BTFTXA42A2V1BTFTXA50A2V1BT …
  • Mitsubishi Heavy Industries

    SRK20ZS-W

    (38 pages)
    RLF012A106SRK20ZS-WSRK25ZS-WSRK35ZS-WSRK50ZS-WSRK20ZS-WBSRK25ZS-WBSRK35ZS-WBSRK50ZS-WBSRK20ZS-WTSRK25ZS-WTSRK35ZS-WTSRK50ZS-WTMITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD.16-5 Konan 2-chome, Minato-ku, Tokyo, 108-8215, Japanhttp://www.mhi-mth.co.jp/en/MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONING EUROPE, LTD.5 The Square, Stockley Park, Uxbridge, Middlese …

Comments, Questions and Opinions: