Manualios.com

Delta Amplon RT Series 5-10kVA Operation & User’s Manual

  • Amplon RT Series 5-10kVA UPS
  • maKUNz4kNCcy6
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 36

Delta Amplon RT Series 5-10kVA Manual Online:

3.7, 1038 votes
Delta Amplon RT Series 5-10kVA User Manual
Delta Amplon RT Series 5-10kVA User Guide
Delta Amplon RT Series 5-10kVA Online Manual

Text of Delta Amplon RT Series 5-10kVA User Guide:

  • Delta Amplon RT Series 5-10kVA, User Manual iii Table of Contents Chapter 1: Important Safety Instructions ------------------------------------------------- 1 Placement Warnings ----------------------------------------------------------------------------------------- 1 Connection Warnings ---------------------------------------------------------------------------------------- 1 Usage Warnings ---------------------------------------------------------------------------------------------- 1 Glossary of Symbols ----------------------------------------------------------------------------------------- 2 Standard Compliance ------------------------------------

  • Delta Amplon RT Series 5-10kVA, 8 User Manual Rack Mounting  Use the included bracket ears and screws to mount the UPS in a rack by following the procedures below. 1. Attach the included bracket ears to the lateral mounting holes of the UPS. See Figure 3-a. 2. Follow steps 1 to 4 to install the UPS in Delta’s rail kit (optional). See Figure 3-b. Step: Adjust the length of the rail according to the rack. Step: Tighten the nuts. Step: Fix the rail on the rack. Step: Insert the UPS in the rack and tighten the screws. 3. If you want to use a non-Delta rail kit, please only follow Step. NOTE: If you need the optional rail kit, please contact your local dealer. Towe

  • Delta Amplon RT Series 5-10kVA, User Manual 15 Firmware Version Look-up  Check the UPS fi rmware version from the LCD. V00: UPS Firmware Version CV00: Compatible Version Code.  When two units are in parallel, each detects whether the compatible version code of the other is the same. If not, the UPS won’t turn on and the alarm message below appears.  If the message above appears, please contact your local dealer to upgrade the fi rmware.  LCD Dispaly Messages: LCD Message Meaning ONLINE MODE Indicates the UPS is in online mode. STANDBY MODE Indicates the UPS is in standby mode

  • Delta Amplon RT Series 5-10kVA, ii User Manual Save This Manual Save This Manual This manual contains important instructions and warnings that you should follow during the installation, operation, storage and maintenance of this on-line UPS. Failure to heed these instructions and warnings will void the warranty. Copyright© by Delta Electronics Inc. All rights reserved. The content in this manual belongs to Delta Electronics Inc., hereafter referred to as Delta. No part of this manual can be quoted or reproduced in any form or by an

  • Delta Amplon RT Series 5-10kVA, User Manual 13  UPS Start-up with Battery: Press the ‘ON’ button for 3~5 seconds to start up the UPS. 1. When you press the ‘ON’ button, the LCD will show the message below. 2. After the ‘ON’ button is pressed for 3~5 seconds, the system will beep. Release the button and the UPS will start up. The UPS performs self-diagnosis and the LCD automatically shows the following messages in order. As there is no input signal available, the UPS will select the default frequency as the output frequency (the default value is 50Hz).  Auto displays

  • Delta Amplon RT Series 5-10kVA, User Manual 1 Placement Warnings  Install the UPS in a well ventilated area, away from excess moisture, heat, dust, fl ammable gas or explosives.  Leave adequate space (at least 15cm) around all sides of the UPS for proper ventilation.  Do not mount the UPS with its front or rear panel facing down at any angle. Connection Warnings  The UPS must be well grounded due to a possible risk of current leakage.  The installation of upstream and downstream protective

  • 2 User Manual and eyes and may be toxic.  Do not dispose of the battery or batteries in a fi re. The batteries may explode.  All maintenance services must be performed by qualifi ed service personnel. Forbid open ing or removing the cover of the UPS to avoid high voltage electric shock.  You must contact qualifi ed service personnel if either of the fo

  • 14 User Manual UPS Turn-off In online mode, press the ‘OFF’ button for 3 seconds to shut down the inverter (the system will beep) and the UPS will transfer to bypass mode. At this moment, the bypass LED illuminates (yellow) and the LCD shows ‘BYPASS MODE’. In backup mode, press the ‘OFF” button for 3 seconds to shut down the inverter (the syst

  • Delta Amplon RT Series 5-10kVA, 28 User Manual Chapter 9: Specifications Specifications *1: The power factor can be modifi ed into 0.8 to let the UPS rating change from 5 k VA/ 4.5 k W, 6 k VA/ 5.4 k W and 10 k VA/ 9 k W into 5.5kVA/ 4.4kW, 7kVA/ 5.6kW and 11kVA/ 8.8kW respectively. *2: At room temperature, at a distance of 1 meter in front of the UPS and when the load is 70% of the rating load. NOTE:  Refer to the rating label for the safety rating.  All specifi cations are subject to change without p

  • Delta Amplon RT Series 5-10kVA, User Manual 11 2. Cable selection: Rating Temperature 5kVA 6kVA 10kVA 60°C 6mm 2 8mm 2 13mm 2 or #6AWG (Cu) 75°C 6mm 2 8mm 2 13mm 2 or #6AWG (Cu) (In accordance with National Electrical Code (NEC), please install the suit- able conduit and bushing.) 3. When connecting the input/ output power cord, please observe the following rules. 1) Turn off the UPS and cut off not only the AC source but also the battery source before connection. 2) Calculate the power consumption of the load to ensure that an overload condition will not occur. 3)

  • Delta Amplon RT Series 5-10kVA, 22 User Manual (Figure 5-f) Rack Style (Figure 5-g) Tower Style Communication Interface NOTE: If you need UPS parallel service, please contact your local dealer or customer service. Tower Stand Battery Cable Parallel Cable External Battery Pack Input Power Cord Output Power Cord External Battery Pack Battery Cable Parallel Cable Input Power Cord Output Power Cord

  • Delta Amplon RT Series 5-10kVA, User Manual 27 Chapter 8: Troubleshooting When you see the following problems appear on the LCD, please follow the solutions shown below. Problem Possible Cause Solution +DC BUS HIGH +DC BUS LOW - DC BUS HIGH - DC BUS LOW BUS OVP FAIL Output has capacitive load or inductive load. Decrease the load. 1. Phase difference in parallel system. 2. UPS has an internal fault. Contact the dealer. OUTPUT SHORT Output has short circuit issue. Check whether output has short circuit or not. If yes, contact the dealer. OVER TEMPERATURE The UPS temperature is too

  • User Manual 21  Battery/ Battery Pack Connection Warnings: 1. Only use the same type of batteries from the same supplier. Never use old, new and different Ah batteries at the same time. 2. The number of batteries must meet UPS requirements. 3. Do not connect the batteries in reverse. 4. Use the voltage meter to measure whether the total voltage, after b

  • Delta Amplon RT Series 5-10kVA, 4 User Manual Features  True on-line design UPS protects your sensitive electronic equipment from power interruption.  Wide AC input voltage range (100Vac~300Vac) reduces frequent transfer from AC mode to DC mode to save battery consumption and prolong battery life.  Smart battery charger design performs auto-charging and reduces the charging time.  Automatic input frequency detection enables operation at 50Hz or 60Hz.  The input power factor correction and the high frequency pulse-width-modulated inverter give the UPS excellent performance characteristics in this compact design.  Battery-Start switch powers on the UPS to

  • Delta Amplon RT Series 5-10kVA, 26 User Manual UPS  UPS Cleaning: Regularly clean the UPS, especially the slits and openings, to ensure that the air freely flows into the UPS to avoid overheating. If necessary, use an air-gun to clean the slits and openings to prevent any object from blocking or covering these areas.  UPS Regular Inspection: Regularly check the UPS every half year and inspect: 1. Whether the UPS, LED, or alarm function has any abnormality. 2. Whether the UPS works in bypass mode (normally, the UPS will work in on-line mode). If yes, check if any error, overload, internal fault, etc. occurs. 3. Whether battery voltage

  • Delta Amplon RT Series 5-10kVA, User Manual 23 Chapter 6: Optional Accessories No. Item Part No. 1. Manual Bypass Box (for single UPS) 3915100706-S35 2. Manual Bypass Box (for parallel UPS) 3915100707-S35 3. Charger Box CHG252C2D1000-N 4. Dust Filter 5/6kVA; 3915100835-S00 10kVA; 3915100840-S00 5. Rail Kit 33129619201 6. External Battery Pack (with batteries) 5/6kVA; GES161B105700 10kVA; GES201B109700 7. Empty Battery Pack (without batteries) 5/6kVA; GES161B105700-N 10kVA; GES201B109700-N 8. EnviroProbe EMS1000000 9. SNMP/WEB Card 39151001

  • User Manual 9 Installation (Figure 3-c) Assemble the Tower Stands (Figure 3-d) Rotate the UPS Control Panel (Figure 3-e) Place the UPS Upright (Figure 3-f) Place the UPS inside the Tower Stands 1 2 4 3

  • Delta Amplon RT Series 5-10kVA, 10 User Manual Connection  UPS Connection Warnings: 1. When connecting the UPS to the mains and the load, it is highly recommended that you in- stall the protective devices. The protective devices must use approved components that meet safety certifi cations. Please refer to the table and diagram below. 2. Prior to providing any power to the UPS, the UPS must be suitably grounded. 3. The power supply to the UPS must be single-phase in accordance with its nameplate.  Input/ Output Connection: 1. Please see the fi gures

  • Delta Amplon RT Series 5-10kVA, User Manual 25 4) Insert the Mini SNMP/ Mini Relay I/O/ Mini USB/ Mini ModBus card into the slot and tighten the screws. (Picture 4) 5) Insert the other end of the fl at cable into CNG3. (Picture 5) 6) Replace the top cover and tighten the screws. ( Picture 6/ 6-1/ 6-2)  Mini TVSS Card Installation: 1. For 5kVA/ 6kVA UPS: 1) Remove the SMART SLOT cover from the rear panel. (Picture 1) 2) Insert the Mini TVSS card into the slot and tighten the screws. (Picture 2/ 2-1) 2. For 10kVA UPS: 1) Remove the SMART SLOT cover from the rear panel. (Picture 1) 2) Insert the Mini TVSS card into the slot and tigh

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 JVC HR-A230E Instructions manual jvc/hr-a230e-NY5.pdf 26 Sep 2022 33
2 MSI WindPad 110W 32GB Operation & user’s manual msi/windpad-110w-32gb-D41.pdf 11 Jan 2024 57
3 JVC HR-5910U Instructions manual jvc/hr-5910u-164.pdf 15 Mar 2023 68
4 SlipStream 30 cc Super Chipmunk Assembly manual slipstream/30-cc-super-chipmunk-121.pdf 29 Mar 2023 24
5 Aroma ARC-920S Instruction manual & cooking manual aroma/arc-920s-OM6.pdf 10 Oct 2022 22 0.28 Mb
6 Zenoah BCZ2400S Owner's/operator's manual zenoah/bcz2400s-MTB.pdf 10 May 2023 36 1.38 Mb

Similar Resources:

  • Emerson

    Liebert PSA 1000VA

    (2 pages)
    Liebert® PSA™Quick-Start Guide - 1000VA/1500VA, 230VIMPORTANT SAFETY INSTRUCTIONS• Do not connect equipment that may overload the UPS or demand half-wave rectification, such as a laser printer.• Connect the UPS only to an earthed / grounded socket that meets electrical safety guidelines.• Locate the UPS near a wall socket. Do not use an extension co …
  • Tripp Lite

    OMNIX350HG

    (5 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: OMNIX350HGOmniSmart 350VA Medical Grade Tower Line-Interactive 230V UPS with Serial port Highlights350VA line interactive tower UPSProfessional features include USB port, IEC320 plug & outlets, built-inisolation transformerInput: IEC320 …
  • HP

    D2D

    (28 pages)
    HP D2D NASIntegration with Symantec™ Backup Exec™2010AbstractThis guide provides step by step instructions on how to configure and optimize Symantec Backup Exec 2010 in order to backup to HP D2D Backup Systems using a CIFS backup target.HP Part Number: EH985-90932Published: February 2011Edition: 1 …
  • Sy-G

    SA1P1LVW

    (31 pages)
    USER MANUAL Online UPS Challenger Series Stand Alone (SA) Rack Mount (RM) Low Voltage & High Voltage Models: SA1P1LVW/SA1P1HVW SA1P2LVW/SA1P2HVW SA1P3LVW/SA1P3HVW Capacity: 1 KVA - 2 KVA - 3 KVA REVISION DESCRIPTION Date Rev. 1.0 Formal Release 2015/11/25 …
  • Powerex

    VI 1000 LED

    (7 pages)
    Uninterruptible Power Supply (UPS) Powerex VI 1000/1500/2000 LED Line Interactive Series Quick Start Guide Thank you for purchasing Powerex UPS. To ensure the correct use of the UPS, please read this manual thoroughly before operate it and save this manual properly. …
  • Eaton

    EX 1000

    (120 pages)
    www.eaton.comInstallation and User ManualManuel d’installation et d’utilisationManual de instalación y de usuarioManual de instalação e do usuárioEnglishFrançaisEspañolPortugueseEX700 – 1000 – 1500 1000 RT2U – 1500 RT2U EXB 1000/1500 EXB 1000/1500 RT2UPulsar Series …

Comments, Questions and Opinions: