  • BLUGUARD SmartBus P900-V16N, version 1.1 14 SmartBus P900 - V16 N NN N USER MANUAL 2. Please refer to User Programming section – Program Auto Disarm Timer. 1. Your system can be remotely DISARM from outside the house through any normal DTMF telephone or GSM hand phone. 2. This disarming mode will automatically turn off the security system when the user enters a correct Master Code through Telephone or hand phone. 3. Please refer to Telephone Control Diagram at page 6. [5] + [HA POINT NUMBERS] + [#] (Press and hold down fo

  • BLUGUARD SmartBus P900-V16N, version 1.1 21 SmartBus P900 - V16 N NN N USER MANUAL [0] + [1 or 2] + [#] (Press and hold down for 2 seconds) 1. This arming mode is ideal for long away occasion (holiday). 2. In this mode, the system will be AWAY armed. Home Automation points will be random ON/OFF every hour to simulate occupancy from 7pm to 1am. 3. Ensure that all zone indicators are distinguished; if not, check that all protected premises are closed. 4. Enter and hold down [0] key for 2 seconds. 5. Zone in

  • BLUGUARD SmartBus P900-V16N, version 1.1 4 SmartBus P900 - V16 N NN N USER MANUAL Intelligent Disarm [4-digit User Code] + [#] Intelligent Arming [4-digit User Code] + [#] Away Arm Hold down [1] for 2 seconds Day Arm Hold down [2] for 2 seconds Night Arm Hold down [3] for 2 seconds Force Arm Hold down [4] for 2 seconds Turn On/Off Home Automation Point Hold down [5] for 2 seconds + [HA point numbers 1 to 8] + [#] Bypass Security Zone Hold down [6] for 2 seconds + [zone numbers 1 to 16] + [#] View System Trouble Hold down [7] for 2 seconds View Alarm Memory Hold down [8] for 2 secon

  • BLUGUARD SmartBus P900-V16N, version 1.1 15 SmartBus P900 - V16 N NN N USER MANUAL 8. To bypass all zones at once, enter [0] key followed buy [#]. 9. Keypad audible indicator will sound 2 beeps to confirm the command and the system will be back to normal mode. 10. The relevant ZONE indicator will slow flash to indicate that the zone is bypassed now. 11. Zones cannot be bypassed once the system is armed. 12. All bypassed zones will be automatically un-bypassed each time the system is disarmed and must be reapplied before the next arming. [6] + [ZONE NUMBERS] + [#] (Press and hold down for 2

  • version 1.1 19 SmartBus P900 - V16 N NN N USER MANUAL 3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the code followed by [#] key to confirm your command. 4. Zone indicator [1] and [2] will flash. Enter the partition number that you wish to arm followed by [#] key. 5. The P1 indicator will il

  • BLUGUARD SmartBus P900-V16N, version 1.1 28 SmartBus P900 - V16 N NN N USER MANUAL 8. If the system fails to contact the preprogrammed personal telephone number 1, system will contact PERSONAL TELEPHONE NUMBER 2 as a back up. 9. To exit user programming mode, press [MODE] followed by [#] key. [30] + [#] 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [30] for personal telephone number 1 setting. 3. Enter the [#] key to erase previous personal telephone number 1 setting. 4. To exit user programming mode, press [MODE] followed by [#] key. [31] + [PERSONAL TELEPHONE NUMBER 2] + [#] 1. Ensure that the system is in USER PROGRAMMING mode.

  • BLUGUARD SmartBus P900-V16N, version 1.1 17 SmartBus P900 - V16 N NN N USER MANUAL 1. This key will activate the FIRE ALARM condition when it is held down for 2 seconds. 2. The FIRE ALARM condition can also be triggered by an installed smoke detector, which is set as fire zone. 3. The siren will sound and the FIRE REPORTING CODE will be transmitted to the central monitoring station. 4. To silence the siren, enter a 4-digit user code followed by [#] key. PANIC MODE [P] (Press and hold down for 2 seconds) 1. This key will activate the PANIC ALARM condition when it

  • BLUGUARD SmartBus P900-V16N, version 1.1 2 SmartBus P900 - V16 N NN N USER MANUAL Alarm Memory This is the history of the most recent violations that occurred the last time when an alarm was triggered. Arm To set the system into the ARMED mode. In this mode, a zone violation will activate an alarm condition. If the system is programmed accordingly, it will cause a reporting code to be sent to the central monitoring station. Bypass To deactivate zone. When the panel is ARMED, violation of a bypassed zone will be ignored. Chime A short beep sound from the keypad to i

  • BLUGUARD SmartBus P900-V16N, version 1.1 22 SmartBus P900 - V16 N NN N USER MANUAL 12. If programmed to do so, the keypad will be locked and non-responsive for a preprogrammed period for certain number of incorrect user codes, which are entered consecutively more than the keypad lock counter (Please refer to Installer Programming Section – Keypad Lock Counter). 13. If the ENTRY delay is too short, have your installer to change the ENTRY delay period. 14. If the MEMORY indicator is flashing upon entry, there has been an intrusi

  • BLUGUARD SmartBus P900-V16N, version 1.1 26 SmartBus P900 - V16 N NN N USER MANUAL 2. Enter [21] for auto disarm timer setting. 3. Enter the [#] key to erase previous AUTO DISARM TIMER setting. 4. To exit user programming mode, press [MODE] followed by [#] key. [22] + [AUTO ON TIMER 1] + [#] 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [22] for auto on timer 1 setting. 3. Enter the [AUTO ON TIMER 1] in 24-hour format, e.g. 8:00pm is 20:00. 4. Enter [#] key to confirm the time. 5. To exit user programming mode, press [MODE] followed by [#] key. [22] + [#] 1. Ensure that the syst

  • BLUGUARD SmartBus P900-V16N, version 1.1 27 SmartBus P900 - V16 N NN N USER MANUAL 3. Enter the [AUTO ON TIMER 2] in 24-hour format, e.g. 8:00pm is 20:00. 4. Enter [#] key to confirm the time. 5. To exit user programming mode, press [MODE] followed by [#] key. [24] + [#] 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [24] for auto on timer 2 setting. 3. Enter the [#] key to erase previous AUTO ON TIMER 2 setting. 4. To exit user programming mode, press [MODE] followed by [#] key. [25] + [AUTO OFF TIMER 2] + [#] 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [25] for aut

  • BLUGUARD SmartBus P900-V16N, version 1.1 25 SmartBus P900 - V16 N NN N USER MANUAL 2. Enter [19] for auto disarm timer setting. 3. Enter the [AUTO DISARM TIMER] in 24-hour format, e.g. 8:00pm is 20:00. 4. Enter [#] key to confirm the time. 5. To exit user programming mode, press [MODE] followed by [#] key. [19] + [#] 1. Ensure that the system is in USER PROGRAMMING mode. 2. Enter [19] for auto disarm timer setting. 3. Enter the [#] key to erase previous AUTO DISARM TIMER setting. 4. To exit user programming mode,

  • BLUGUARD SmartBus P900-V16N, version 1.1 31 SmartBus P900 - V16 N NN N USER MANUAL Telephone Number 2 : _____________________________________________ Dialing Attempt : _____________________________ times Home Automation Home Automation 1 Turn On Time ___ ___ : ___ ___ am / pm Home Automation 1 Turn Off Time ___ ___ : ___ ___ am / pm Home Automation 2 Turn On Time ___ ___ : ___ ___ am / pm Home Automation 2 Turn Off Time ___ ___ : ___ ___ am / pm Servicing Installer company : _____________________________________________ Contact person : _____________________________________________

  • version 1.1 8 SmartBus P900 - V16 N NN N USER MANUAL Enter User Programming Mode [ Ж ] + [MODE] + [4-digit Master Code] + [#] Exit User Programming Mode [MODE] + [#] Program New or Change Existing Master Code [01] + [New Master Code] + [Re-enter New Master Code] + [#] Program New or Change Existing User Code 2 [02] + [New User Code] + [Re-enter New User Co

  • version 1.1 23 SmartBus P900 - V16 N NN N USER MANUAL [MODE] + [#] 1. Once all setting is programmed, press [MODE] followed by [#] key to exit. 2. The POWER and SERVICE indicators will stop flashing. 3. The keypad will sound 2 beeps to confirm the exit command. [COMMAND ADDRESS] + [NEW CODE] + [RE-ENTER NEW CODE] + [#] 1. Ensure that t

  • BLUGUARD SmartBus P900-V16N, version 1.1 12 SmartBus P900 - V16 N NN N USER MANUAL 5. The P1 indicator will illuminate and the keypad audible indicator will sound on and off for the duration of the EXIT delay. Any bypassed zones will be shown by the flashing zone indicators. 6. Leave the premises only via the EXIT/ENTRY zone. 7. User will be given an ENTRY delay time to disarm the system when enter the protected premises via ENTRY/EXIT zone. 8. After disarming, Home Automation random

  • BLUGUARD SmartBus P900-V16N, version 1.1 1 SmartBus P900 - V16 N NN N USER MANUAL The BLUGUARD Control Panel is designed for simple operation yet provides the maximum protection for you. Please read this manual carefully and follow the instructions contained in this book. Fill in the system information page and store this manual in a safe place for future reference. Your security system consists of a main control panel, one or more keypads and home automation (HA) modules, various sensors and detectors. An enclosure will contain the control panel, which includes the system electronics and standby battery.

  • BLUGUARD SmartBus P900-V16N, version 1.1 7 SmartBus P900 - V16 N NN N USER MANUAL USER PROGRAMMING SUMMARY DIAGRAM ENTER USER PROGRAMMING MODE [ ] + [MODE] + [Master Code] + [#] Correct code or step – 2 beeps Wrong code or step – 1 long beep MASTER CODE Press [01] + [New Code] + [Re-enter New Code] + [#] PROGRAM C ODES USER CODE Press [02 - 14] + [New Code] + [Re-enter New Code] + [#] DOOR ACCESS CODE Press [15] + [New Code] + [Re-enter New Code] + [#] DURESS CODE Press [16] + [New Code] + [Re-enter New Code] + [#]

  • BLUGUARD SmartBus P900-V16N, version 1.1 29 SmartBus P900 - V16 N NN N USER MANUAL Users are advised to test the system as frequent as possible. System must be tested at least once every 3 months. If the system is not functioning accordingly, please contact your system installer for technical assistance. [MODE] + [1] + [#] 1. Walk Test allows on-site testing of each zone of the system. 2. During walk test mode, the P1, P2 and SERVICE indicators will slow flash. 3. Siren will trigger

  • BLUGUARD SmartBus P900-V16N, version 1.1 10 SmartBus P900 - V16 N NN N USER MANUAL [∗ ∗∗ ∗] + [USER CODE] + [#] (Leave via ENTRY/EXIT Zone) 1. Ensure that all zone indicators are distinguished; if not, check that all protected premises are closed. 2. Press the [∗ ∗∗ ∗] key to cancel any unintended entries. 3. Enter a valid 4-digit [USER CODE]. If you enter any mistakes, press [∗ ∗∗ ∗] key and re-enter the code followed by [#] key to confirm you command. 4. The P1 indicator will illuminate and the keypad audible indicator will sound

  • BLUGUARD SmartBus P900-V16N, version 1.1 11 SmartBus P900 - V16 N NN N USER MANUAL [3] (Press and hold down for 2 seconds) 1. This arming mode is ideal for NIGHT time arming with user still remains in the protected premises. 2. In this mode, the system will be armed instantly with certain preprogrammed, NIGHT STAY zones bypassed automatically. 3. Ensure that all zone indicators are distinguished; if not, check that all protected premises are closed. 4. DO NOT open the ENTRY/EXIT zone. 5. Enter and hold down [3] key for 2 seconds. 6. The P1 indicator will illuminate and the keypad audible indicator will sound 2 beeps to confirm

  • BLUGUARD SmartBus P900-V16N, version 1.1 6 SmartBus P900 - V16 N NN N USER MANUAL Remark: The system will automatically cut off telephone line if the user does not key in any number for more than 60 seconds or key in wrong master code more than 3 times. P900 - V16 N & GSM MODULE TELEPHONY CONTROL DIAGRAM Call In to System: # (Terminate Telephone Reporting Immediately) 2 Force Arm / Disarm system 1 System Voice Report on: - Alarm triggered zone - System Arm / Disarm

  • BLUGUARD SmartBus P900-V16N, version 1.1 9 SmartBus P900 - V16 N NN N USER MANUAL Program System Timer System Clock [17] + [Current Time in 24-hour Format] + [#] Program Security Timers Partition 1 Auto Arm Timer [18] + [Partition 1 Security Auto ARM Timer] + [#] Partition 1 Auto Disarm Timer [19] + [Partition 1 Security Auto DISARM Timer] + [#] Partition 2 Auto Arm Timer [20] + [Partition 2 Security Auto ARM Timer] + [#] Partition 2 Auto Disarm Timer [21] + [Partition 2 Security Auto DISARM Timer] + [#]

  • version 1.1 3 SmartBus P900 - V16 N NN N USER MANUAL UNDERSTAND YOUR KEYPAD INDICATORS ZONE INDICATORS (Red) Indicate the status of the zones ARMED INDICATOR (Red) The indicator is illuminated when the system is armed PO

  • BLUGUARD SmartBus P900-V16N, version 1.1 16 SmartBus P900 - V16 N NN N USER MANUAL ZONE 6 indicator Telephone Line/GSM Personal Reporting Fail ZONE 7 indicator Telephone Line Connection Fail Remark: Zone 1, 2, 3 and 4 indicators will only be extinguished after the troubles are restored. Zone 5, 6 and 7 indicators will be extinguished when they are viewed once. [8] (Press and hold down for 2 seconds) 1. The system alarm memory will store the most recent alarm condition. An alarm condition will cause the MEMORY indicator to slow flash. 2. The MEMORY indicator will extinguish once the user enters VIEW ALARM MEMORY

  • version 1.1 5 SmartBus P900 - V16 N NN N USER MANUAL PARTITION SYSTEM ENABLED Intelligent Disarm [4-digit User Code] + [#] + [Partition 1] or [Partition 2] Intelligent Arming [4-digit User Code] + [#] + [Partition 1] or [Partition 2] Away Arm Hold down [1] for 2 seconds + [Partition 1] or [Partition 2] Day Arm Hold down [2] for 2 seconds + [Partition 1

  • BLUGUARD SmartBus P900-V16N, version 1.1 20 SmartBus P900 - V16 N NN N USER MANUAL 1. This arming mode is ideal for DAY time arming with user still remains in the protected premises. 2. In this mode, system will be armed instantly with certain preprogrammed, DAY STAY zones bypassed automatically. 3. Ensure that all zone indicators are distinguished; if not, check that all protected premises are closed. 4. DO NOT open the ENTRY/EXIT zone. 5. Enter and hold down key [2] for 2 seconds. 6. Zo

  • BLUGUARD SmartBus P900-V16N, version 1.1 18 SmartBus P900 - V16 N NN N USER MANUAL Zones can be divided into two systems. Based on your requirements, the installer designates which zones belong to Partition 1 and Partition 2, both partitions (dual area), or are not given any partition assignment. A zone belonging to a 2 partitions is armed only when both Partition 1 and Partition 2 are armed. However, this sharing zone will be disarmed if either Partition 1 or Partition 2 is disarmed. The installer must progr

  • BLUGUARD SmartBus P900-V16N, version 1.1 13 SmartBus P900 - V16 N NN N USER MANUAL b. Keypad Disarming c. Remote Control Disarming d. Timer Auto Disarming e. Telephone Remote Disarm For information on how to DISARM Partition system, please refer to PARTITIONING THE SYSTEM at page 17. [USER CODE] + [#] 1. To disarm the system, enter a valid 4-digit [USER CODE] followed by [#] key before expiry of the entry delay time. 2. Enter the premises through a designated ENTRY/EXIT zone; entering via other zones will trigger an alarm instantly. 3. The ENTRY delay begins once the ENTRY zone is vi

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Rose electronics CrystalLink USB Fiber Installation and operation manual rose-electronics/crystallink-usb-fiber-Y98.pdf 04 Sep 2023 16 0.21 Mb
2 SEVERIN HS 7742 Dimensions severin/hs-7742-OT3.pdf 07 Aug 2022 1 0.63 Mb
3 Biostar M6TSM Datasheet biostar/m6tsm-6LL.pdf 02 Oct 2022 54 0.63 Mb
4 Omcan MX-CN-0020-G Instruction manual omcan/mx-cn-0020-g-964.pdf 03 Sep 2023 28
5 LG KS360 Brochure lg/ks360-IMD.pdf 27 Jan 2023 10
6 Carrier ROOMTOP 50AH024-096 Installation and service instructions manual carrier/roomtop-50ah024-096-2CO.pdf 06 Jun 2023 20 0.73 Mb

Similar Resources:

  • Edwards

    B-KH Series

    (2 pages)
    P-047550-1605 ISSUE 1© 1996CHESHIRE, CT 203-699-3000 FAX. 203-699-3075™Installation Instructions for B-KH SeriesRemote Phone Signalyour line should not exceed five. To be sure of the number ofdevices you can connect to your telephone line, contact yourlocal telephone company.If these devices damage the telephone network, the telephonecompany will notif …
  • V-Tec

    C5-AT25/D4

    (12 pages)
    EnglishVIDEO INTERCOM SYSTEMUSER MANUALMENUTALKMONITORMain MenuMonitor ...IntercomAlarm Function ...User SetupCloseAbout OK Select ItemC5-AT25/D4 Version 1.0 120313 …
  • Winnebago

    SunCruiser

    (141 pages)
    TABLE OF CONTENTS5 - DASH / AUTORev. 0715090608 June 2009 Part No. 132000-15-007Copyright 2006 Winnebago Industries, Inc. All rights reserved.INTRODUCTION 1About this Manual ............................................................................................................................ 1-1Safety Messages Used in this Manual ..................... …
  • Mopar

    Jeep Commander (XK)

    (12 pages)
    INSTALLATION INSTRUCTIONSProfessional Installation is RecommendedTechnical SupportFor Authorized Dealers - (800) 34-MOPARHours: 9:00 a.m. - 6:00 p.m. EST Monday thru Friday 10:00 a.m. - 2:00 p.m. EST Saturday1030930REV. A8/05K6859684Jeep Grand Cherokee (WK)Jeep Commander (XK)Security SystemNote: Both Factory RKE Keyfobs are required foroption programming …
  • SOMFY

    5013494

    (2 pages)
    EDACBCx3x21www.somfy.com5013494Somfy SAS dans un souci constant d’évolution et d’amélioration peut modifier le produit sans préavis. Photos non contractuelles.Somfy SAS in a constant concern of evolution and improvement may modify the product without prior notice. Non contractual pictures.©SOMFY. GMD030110 - SOMFY SAS, capital 20.000.000 Euros, RCS B …
  • Eaton

    Crouse-hinds series

    (20 pages)
    Explosionsgeschützte Deckeneinbau NotleuchtenSerie: eLLB 20018/18 NIB, eLLB 20418 NIB, eLLB 20036/36 NIB, eLLB 20436 NIBExplosion protected recessed ceiling emergency light fittingsSeries: eLLB 20018/18 NIB, eLLB 20418 NIB, eLLB 20036/36 NIB, eLLB 20436 NIBLuminaires de sécurité pour atmosphères explosives Série: eLLB 20018/18 NIB, eLLB 20418 NIB, …

Security System Instructions:

Comments, Questions and Opinions: