Manualios.com

iTrust Adapt Operation & User’s Manual

iTrust Adapt Manual Online:

3.75, 1344 votes
iTrust Adapt User Manual
iTrust Adapt User Guide
iTrust Adapt Online Manual

Text of iTrust Adapt User Guide:

  • Chapter 5 Maintenance And Troubleshooting 25 iTrust Adapt 6kVA UPS User Manual It is recommended to check the UPS functions once every half year. Backup the load data, before conducting the UPS functions check. Procedures are as follows: 1. Press the OFF key to check if the buzzer beeps, indicators are on and the LCD display is normal. 2. Press the ON/SILENCE

  • iTrust Adapt, 22 Chapter 4 Operation Instructions iTrust Adapt 6kVA UPS User Manual Turning off UPS from Battery mode When the UPS is operating in Battery mode, press and hold the OFF key for one second. At this point, the UPS turns off, the UPS ceases output, the load is powered off, the UPS is not powered off completely and the BATTERY indicator flashes, as shown in Figure 4-7. If you wish to power off the UPS completely, you need to press and hold the OFF key for ten seconds. L O A D F A U L T O F F O N / S I L E N C E U T I L I T Y B A T T E R Y B Y P A S S I N V E R T E R B A T T E R Y

  • iTrust Adapt, Appendix 4 POD 35 iTrust Adapt 6kVA UPS User Manual Appendix 4 POD UPS parallel output power distribution unit (POD for short) includes single-phase input single-phase output 1 +1 POD, single-phase input single-phase output 3 + 1 POD and 3-phase input single-phase output 3 + 1 POD. This chapter introduces the appearances and ports of the three PODs. 1. Single-Phase Input Single-Phase Output 1 + 1 POD The appearance of the single-phase input single-phase output 1 + 1 POD is show in Figure 13. Plastic panel Figure 13

  • iTrust Adapt, 20 Chapter 4 Operation Instructions iTrust Adapt 6kVA UPS User Manual L O A D F A U L T O F F O N / S I L E N C E U T I L I T Y B A T T E R Y B Y P A S S I N V E R T E R B A T T E R Y Figure 4-2 Indicator displaying during UPS turning on Pressing the OFF key for 1s to confirm the UPS is in the bypass mode, the interface is shown in Figure 4-3. L O A D F A U L T O F F O N / S I L E N C E U T I L I T Y B A T T E R Y B Y P A S S I N V E R T E R B A T T E R Y Figure 4-3 Bypass mode It is recommended that load be less than

  • Chapter 4 Operation Instructions 23 iTrust Adapt 6kVA UPS User Manual 4.7.3 Transferring UPS From Inner Overheating Protection To Bypass Mode Keep proper ambient temperature and favorable ventilation for the UPS. Otherwise, the UPS internal temperature will rise. At this point, the UPS will switch to Bypass, the FAULT indicator will turn on, indicator 3 will blink (see

  • iTrust Adapt, Chapter 2 Installation 9 iTrust Adapt 6kVA UPS User Manual 2.4 Connecting Cables UPS is applicable to the TN and TT power distribution system. UPS cables include input and output cables (prepared by yourself) and battery cables (delivered with battery module). Input cables and output cables should be at least 10AWG or 6mm2 copper wires. Tube cable lugs must be added to all cables to ensure reliable connection. 2.4.1 I/O Terminal Block The UPS provides an I/O terminal block

  • iTrust Adapt, 4 Chapter 1 Product Description iTrust Adapt 6kVA UPS User Manual 1.5.3 Battery Mode Upon mains failure, rectifier overload or mains voltage outside the specifications, the rectifier and internal charger will become inoperative, and the battery will power the load through the inverter. When the UPS is in Battery mode, the BATTERY indicator and INVERTER indicator are on, and the buzzer beeps every 3.3 seconds, notifying the user that the battery is powering the load.  Note 1. In Battery mode, whe

  • iTrust Adapt, 4.2 UPS Power-On ................................................................................................................................. 19 4.3 Turning On UPS................................................................................................................................ 19 4.4 Battery Self-Test ............................................................................................................................... 20 4.4.1 Battery Power-On Self-Test................................................................................................... 20 4.4.2 Battery

  • iTrust Adapt, 12 Chapter 2 Installation iTrust Adapt 6kVA UPS User Manual 1. Remove the protective cover of the SNMP card, as shown in Figure 2-11 (a). Take care of the protective cover for future use. 2. Insert the SNMP card to the SNMP card slot and fasten it with screws, as shown in Figure 2-11 (b). 3. Connect the UPS to computer network port with network cables (prepared by users). 4. For the setting and use of the SNMP card, refer to UPS Web/SNMP Agent Card User Manual. SNMP card solt Protective cover SNMP card (a) (b) Figure 2-11

  • 28 Appendix 1 Battery Module iTrust Adapt 6kVA UPS User Manual Replacing battery fuse If the battery internal fuse is damaged, loosen the protective cover on the rear panel of the battery module and replace the damaged fuse with a new one, then tighten the fixing screws of the protective cover to prevent electric shock risk during the UPS operation, as shown in

  • iTrust Adapt, Chapter 2 Installation 7 iTrust Adapt 6kVA UPS User Manual 2.3.1 Tower Installation  Note Various installation configurations are available: single UPS, single UPS with single- or multiple-battery. Their installation methods are all the same. Installation method: 1. Take out support bases from the accessories, and snap them up in the direction shown in Figure 2-1, and then put the support bases down on the installation surface flatwise. Figure 2-1 Installing support base (top view) 2. If ba

  • iTrust Adapt, 18 Chapter 3 Operation And Display Panel iTrust Adapt 6kVA UPS User Manual 3.2.1 UPS State Indicators UPS state indicators (see Figure 3-1) indicate the UPS operation and fault state, as described in Table 3-2. Table 3-2 LED indicator description Indicator No. Definition Color Description 6 FAULT indicator Red On in the event of fault, and off otherwise 7 UTILITY indicator Green On when the mains is normal, off during mains failure, and flashes when mains voltage

  • iTrust Adapt, 8 Chapter 2 Installation iTrust Adapt 6kVA UPS User Manual 2.3.2 Rack Installation  Note 1. Various installation configurations are available: single UPS, single UPS with single or multiple-battery. Their installation methods are all the same. 2. Because battery modules are too heavy, two or more installation personnel are required to install them at the same time. Please install them from bottom to top. Rack installation: fix the UPS and battery module onto the rack through bra

  • iTrust Adapt, 32 Appendix 3 LCD Operation And Display Panel iTrust Adapt 6kVA UPS User Manual Main menu Level-1 menu Level-2 menu Level-3 menu Level-4 menu Abnormal input Abnormal bypass Battery discharge end Battery fault Output overload Output short Charger failure Over-temperature for radiator Fan fault auxiliary supply failure Input neutral line in disconnected Parallel line fault Current sharing fault Parallel address conflict Alarm message Module communication fault UPS1# UPS2# UPS3# UPS4# System information Return The c

  • iTrust Adapt, iTrust Adapt 6kVA UPS User Manual Version V1.0 Revision date BOM Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Copyright © 2009 by Emerson Network Power Co., Ltd. All rights reserved. The contents in this document are subject to change without notice.

  • iTrust Adapt, Chapter 2 Installation 13 iTrust Adapt 6kVA UPS User Manual The installation methods of the POD and battery module are the same as that of the UPS. For details, refer to 2.3.2 Rack Installation. The installation diagram of the single-phase input single-phase output 1 + 1 parallel system excluding battery module is shown in Figure 2-13. B A T T E R Y 电 池 关 机 / o f f O N / S i l e n c e 开 机 / 消 音 L O A D 负 载 B A T T E R Y 电 池 U T I L I T Y 市 电 F A U L T 故 障 旁 路 B Y P A S S 逆 变 I N V E R T E R B A T T E R Y L O A D I N V E R T E R 旁 路 B A T T E R Y U T I L I T Y F A U L T 故 �

  • iTrust Adapt, Chapter 2 Installation 15 iTrust Adapt 6kVA UPS User Manual 2.5.3 Connecting Parallel Cables The UPS provides parallel ports on the rear panel, as shown in Figure 1-2. Parallel cables are accessories of the POD. Follow Figure 2-188 to connect parallel cables. UPS1 UPS2 UPS3 UPS4 Parallel port 1 Parallel port 2 Parallel port 1 Parallel port 2 Parallel port 1 Parallel port 2 Parallel port 1 Parallel port 2 Parallel cable Parallel cable Parallel cableParallel cable Parallel cable Figure 2-18 N + 1 parallel cable connection diagram 2.5.4 Connecting POD Cab

  • iTrust Adapt, Appendix 2 Communication Function 29 iTrust Adapt 6kVA UPS User Manual Appendix 2 Communication Function The UPS provides not only SNMP card but also dry contact, MODBUS card and other communication components. This chapter only introduces SNMP card. For the installation and use of the other communication components, refer to information delivered with each communication components. The SNMP card realizes remote monitoring. For details, setting and use of the SNMP card, refer to UPS Web/SNMP Agent Card User Manual. The SNMP card ports and USB ports cannot be used at the same time. The layout of pins for the SNMP card ports is shown in Figure 4. 1

  • 38 Chapter 5 Setting 6kVA/4.2kW Capability iTrust Adapt 6kVA UPS User Manual Appendix 5 Optional Part List The optional part list is given in Table 10. Table 10 Optional part list Optional part Type Remark U16-07C1 Standard configuration U20-24C2 User needs to select a battery cabinet with two layers U20-38C3 User needs to select a battery

  • iTrust Adapt, 30 Appendix 3 LCD Operation And Display Panel iTrust Adapt 6kVA UPS User Manual Appendix 3 LCD Operation And Display Panel LCD operation and display panel is an optional. The installation and debugging had been finished before delivered. You cannot install and maintain it by yourself. 1. Brief Introduction The LCD operation and display panel provides a LCD, indicators and control keys, as shown in Figure 5, which are used to display and control the following information: operation parameters, alarm information and function setup. LCD OFF key ENTER key CIRCLE key ON/S

  • iTrust Adapt, Contents Chapter 1 Product Description .......................................................................................................................... 1 1.1 Features.............................................................................................................................................. 1 1.2 Model Configuration............................................................................................................................ 1 1.3 Appearance And Components.................................................................................

  • iTrust Adapt, Chapter 1 Product Description 1 iTrust Adapt 6kVA UPS User Manual Chapter 1 Product Description iTrust Adapt 6kVA UPS (UPS for short) is an intelligent online UPS system with sine wave output developed by Emerson Network Power Co., Ltd. The UPS provides reliable and high quality AC power to your sophisticated equipment. The UPS adopts modular design, and rack/tower installation can be used depending on your requirements. It is applicable to supplying AC power to small scale computer center, network, communication system, automatic control system and

  • Chapter 2 Installation 11 iTrust Adapt 6kVA UPS User Manual The battery cable connection of standard UPS is shown in Figure 2-10. UPS Battery module Battery port Battery port (2pcs) Figure 2-10 Battery cable connection of standard UPS  Note 1. It is prohibited to reverse the positive pole and negative pole of the battery. 2. Different UPS cannot use the same ba

  • iTrust Adapt, Appendix 3 LCD Operation And Display Panel 33 iTrust Adapt 6kVA UPS User Manual The contents displayed in level-2 menu are shown in Figure 9 if the UPSs are parallel. The displayed contents are the same except the UPS address. The definitions of the control keys in this interface are listed in Table 6. UPS1 INPUT BATTERY BYPASS OUTPUT RETURN UPS1 SYSTEM SETTING RESUME SETTING LCD SETTING RETURN UPS1 OUT SHORT! Running interface Setting interface Alarm message i

  • iTrust Adapt, Chapter 3 Operation And Display Panel 17 iTrust Adapt 6kVA UPS User Manual Chapter 3 Operation And Display Panel This chapter introduces the control keys and indicators of the operation and display panel. The operation and display panel is located on the front panel of the UPS (see Figure 1-1), which provides two control keys and ten indicators, as shown in Figure 3-1. B A T T E R Y L O A D F A U L T U T I L I T Y I N V E R T E R B Y P A S S B A T T E R Y O F F O N / S I L E N C E 7 8 10 9 2 1 6 OFF key ON/SILENCE key 3 4 5 Figure 3-1 Operation and display panel 3.1 Control Keys The operation and display panel provides two control keys

  • iTrust Adapt, Chapter 1 Product Description 5 iTrust Adapt 6kVA UPS User Manual 1.6 Specifications The UPS specifications are listed in Table 1-2. Table 1-2 UPS specifications Standard UPS Extended UPS Product model UHA1R-0050 UHA1R-0050L Rated voltage Single-phase: 220Vac, 3-phase: 380Vac Voltage range 176Vac ~ 276Vac, at full load 120Vac ~ 160Vac, linear derating 120Vac, at half load Frequency 50Hz ± 5Hz Input Power factor Single-phase: ≥ 0.99, 3-phase: ≥ 0.95 Rated power 6kVA/4.2kW Voltage 220Vac ± 3% Frequency In Normal mode: synchr

  • iTrust Adapt, 14 Chapter 2 Installation iTrust Adapt 6kVA UPS User Manual 保险 FUSE F32AH 400Vdc CAUTION: For Continued Protect i on Against Risk of Fire. Replace Only With The Same Type and Rating o f Fuse. 保险 FUSE F32AH 400Vdc CAUTION: For Continued Protect i on Against Risk of Fire. Replace Only With The Same Type and Rating o f Fuse. 保险 FUSE F32AH 400Vdc CAUTION: For Continued Protect i on Against Risk of Fire. Replace Only With The Same Type and Rating o f Fuse. 保险 FUSE F32AH 400Vdc CAUTION: For Con

  • iTrust Adapt, 2 Chapter 1 Product Description iTrust Adapt 6kVA UPS User Manual 1.3 Appearance And Components 1.3.1 Appearance The UPS appearance is shown in Figure 1-1. Operation and display panel Ventilation holes B A T T E R Y L O A D F A U L T U T I L I T Y I N V E R T E R B Y P A S S B A T T E R Y O F F O N / S I L E N C E Figure 1-1 UPS appearance  Note Non-professionals are prohibited from opening the chassis cover. Failure to observe this could result in electric shock. 1.3.2 Components Operation and display panel The UPS provides a

  • iTrust Adapt, 26 Chapter 5 Maintenance And Troubleshooting iTrust Adapt 6kVA UPS User Manual No. Fault Possible cause Action to take 12 The buzzer beeps for a long time, the FAULT indicator illuminates, and the LCD displays RECTIFIER FAIL, INVERTER FAIL, AUX SUPPLY FAIL, or OUTPUT FAIL UPS internal fault The UPS needs repair. Seek technical assistance from the local service center of Emerson. 13 Abnormal noise or smell in UPS UPS internal fault Turn off the UPS and cut off the power input immediately. Seek technical assistance from the local s

More Instructions:

DOWNLOAD

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Toyota SIENNA 2009 Quick reference manual toyota/sienna-2009-489.pdf 20 Jan 2024 438
2 Plantronics SAVI GO WG100/B Operation & user’s manual plantronics/savi-go-wg100-b-N22.pdf 07 Nov 2022 17
3 Compaq Concerto Maintenance and service manual compaq/concerto-9W1.pdf 19 Jun 2023 153
4 Lindy 51082 Operation & user’s manual lindy/51082-A45.pdf 07 Mar 2024 3
5 Canon PIXMA MX726 series Getting started canon/pixma-mx726-series-9E7.pdf 28 Feb 2023 4
6 Audemat-Aztec FMB10 Operation & user’s manual audemat-aztec/fmb10-235.pdf 13 Jan 2023 53

Similar Resources:

  • socomec

    NETYS PL

    (16 pages)
    NETYS PL600-800 VA安装及操作手册 CNInstallations- und bedienungsanleitung DEManual de instalación y uso ES Manuel d’installation et d’utilisation FR Installation and operating manual GB Manuale di installazione e uso IT Installatie– en bedieningshandleiding NLDokumentacja Techniczno-Ruchowa PLManual de instalação e funcionamento PTManual de i …
  • Siel

    SAFEPOWER EVO-HF 200

    (52 pages)
    IV386 Rev.000 SIEL S.p.A. Data di emissione: 2015-10-02 Pag. 55 di 263 + FR INTRODUCTION Thank you for choosing our product. Our company is highly specialised in the development and production of uninterruptible power supplies (UPS). The UPS device described in this manual is a high quality product that h …
  • Marathon Power

    Tri-Athlon ATWS-10003-02

    (48 pages)
    Tri-Athlon 3-Phase Uninterruptible Power System User Manual for Models: ATWS-10003-02 ATWS-15003-02 ATWS-20003-02 ATWN-10003-02 ATWN-15003-02 ATWN-20003-02 …
  • HP

    D2D

    (2 pages)
    © 2010 Hewlett-Packard Development Company, L.P.Printed in the EUwww.hp.comEH985-909011 About your HP StoreOnce Backup SystemThe HP StoreOnce Backup System is a disk-based storage appliance for backing up host network servers or PCs to target devices on the appliance. These devices are configured as either NAS or Virtual Tape Library targets for backup a …
  • Njoy

    Soter 600

    (32 pages)
    Soter 600User ManualPWUP-LI060SR-AZ01BBefore using this product, carefully read all product documentation and retain it for future reference.Bedienungsanleitung Korisničko uputstvoРъководство на потребителяHasználati utasításУпатство за употребаManuali I PërdorimitManual de utilizare …
  • Tripp Lite

    SU80KX

    (5 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SU80KXSmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS Highlights80,000 VA (80kVA) 3-phase tower UPSN+1 redundant modular architecture helps assure 100% availability1+1 parallel capability allows for …

Comments, Questions and Opinions: