  • Allen-Bradley 1784-KT/B, Communication Interface Module Installation Data Cat. No. 1784-KT/B The 1784-KT/B Communication Interface Module allows personal computers, workstations or terminals to communicate with Allen-Bradley processors and controllers, either through direct connections or over Data Highway Plus networks. For information about using the 1784-KT/B with a specific device, see the device’s user documentation. ATTENTION: The following provides information for Allen-Bradley Industrial Computer and Communication Group (ICCG) products that have been verified to meet the Electromagnetic Interference (EMI) requirements of the F

  • Communication Interface Module Cat. No. 1784KT/B Installation Data 12 Connecting Y our 1784KT to a PLC5 (Data Highway Plus) To connect the 1784-KT to a PLC-5, follow the steps below: 1. Plug the 62-pin connector end of the 1784-CP cable into the 1784-KT and secure with captive screws. 1784 - KT Board Peer Communication Interface Connector 1784 - CP C

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 21 Specifications Module Location • The 1784KT/B can be installed in any slot that supports ISA 8bit cards Module Output Connector • 62 Pin Dshell Outputs • PLC2 Serial Interface • PLC3 Serial Interface • Data Highway Plus Module Compatibility • AllenBradley 1771 Information Processor (1771DSX2) (requires KT Expander Module 1771DXKT) • AllenBradley 1784T35 Industrial T erminal • AllenBradley 1784T50 Industrial T erminal • AllenBradley 6121 • AllenBradley 6122 •

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 5 The 1784-KT utilizes CMOS technology, which is highly sensitive to Electro Static Discharge (ESD). ESD may be present whenever you are handling the 1784-KT. Handling the 1784-KT without any ESD protection can cause internal circuit damage that may not be apparent during installation or initial use. A grounding wrist strap has been shipped with the 1784-KT to be worn during the installation procedure. Instructions for use of the strap are found on the bac

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 8 Table C Recommended interrupt settings Equipment: Preferred Interrupt: 1784T35 IRQ5 1784T50 IRQ5 T53 Industrial Programming Terminal no interrupt T60 Industrial Workstations T70 Industrial Workstations 8. Set the memory location address, by pushing the switches in at either the top or bottom, to reflect the selected address of the memory location. Interrupt Jumper (shown in no interrupt" position) Address Switch (shown at D400:0000 setting) Up = 0 switch pressed in at top Down = 1 switch pressed in at bott

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 18 IBM PC XT System Memory Allocation W orksheet Memory Address IBM PC XT Assignments Your System 0000:0000 3F00:0FFF 128256K Read/Write Memory on System Board 4000:0000 9F00:0FFF 384K Read/Write Memory Expansion in I/O Channel A000:0000 A400:0000 A800:0000 AC00:0000 B000:0000 Monochrome B400:0000 B800:0000 Color/Graphics BC00:0000 C000:0000 C400:0000 C800:0000 Fixed Disk Control CC00:0000 D000:0000 D400:0000 D800:0000 E000:0000 E400:0000 E800:0000 E

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 13 The 1784-AGT Test Plug is available for diagnostic testing of the 1784-KT. Its internal wiring is shown below. 1 2 4 8 3 6 5 23 24 43 26 47 28 A1 TXD A1 TXD RET A1 IN0 A2 TXD A2 OUT0 A3 TXD+ A2 TXD RET 7 48 27 A2 OUT0 RET A1 RXD A1 RXD RET A1 OUT0 A2 RXD A2 RXD RET A2 IN0 A2 IN0 RET A3 RXD+ 9 10 12 16 11 14 13 15 29 30 31 34 36 58 59 35 17 18 20 33 19 22 21 32 38 37 40 39 56 50 49 55 41 42 45 44 52 51 57 62 61 25 46 54 60 53 A3 RXD- A3 IN0+ A3 IN0- A4 RXD+ A4 RXD- RET A3 TXD- A3 OUT0+ A3 OUT0- Chassis Gnd A4 TXD RET A4 T

  • Communication Interface Module Cat. No. 1784KT/B Installation Data 11 Connecting Y our 1784KT to a PLC3 To connect the 1784-KT to a PLC-3, follow the steps below: 1. Plug the 62-pin connector end of the 1784-CP3 cable into the 1784-KT and secure with captive screws. 1784 - KT Board Peripheral Channel 0" 1784 - CP3 Cable 16687b 2. Connect the opposite end of the 1784-CP3 c

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 2 We will refer to the 1784-KT/B Communication Interface Module as simply the 1784-KT throughout this document. This document contains the following sections: Introducing the 1784-KT Communication Interface Module Important User Information Features of the 1784-KT Compatibility How the 1784-KT Operates Handling the 1784-KT Module 1784-KT Configuration Information Installing the 1784-KT into a Computer Connecting Your 1784-KT Ordering Information The Loopback Test Plug System Memory and Interrupts Specifications Because of the variety of uses for products described in this publication, those responsibl

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 7 Table B Selecting a memory location Memory Address (Hex) PCB Board Switch Settings Switch Settings 2 M L S S B B A14 (switch 1) A15 (switch 2) A16 (switch 3) A17 (switch 4) A18 (switch 5) A19 (switch 6) LM SS BB A000:0000 up up up down up down 000101 A400:0000 down up up down up down 100101 A800:0000 up down up down up down 010101 AC00:0000 down down up down up down 110101 B000:0000 up up down down up down 001101 B400:0000 down up down down up down 101101 B800:0000 up down down down up down 011101 C000:0000 up up up up down down 000011 C400:0000 down up up up down down 100011 C80

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 4 Operation of the 1784-KT has been verified with the following: Company: Model: AllenBradley • 1771 Information Processor (1771DSX2) (requires KT Expander Module 1771DXKT) • 1784T35 Industrial Terminal • 1784T50 Industrial Terminal • AllenBradley 6121 • AllenBradley 6122 • T53 Industrial Programming Terminal 6160T53 • T60 Industrial Workstation 6160PCD2, PCN2, PCD4, PCN4 • T70 Industrial Workstation 6170 series IBM  • IBM PCXT/AT Compaq  • Compaq Portable 286 • Compaq Portable II • Compaq Portable III • Com

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 17 Timer Output Keyboard (Output Buffer Full) Interrupt from CTLR 2 Serial Port 2 Serial Port 1 Parallel Port 2 Diskette Controller Parallel Port 1 Realtime Clock Interrupt Reserved Reserved Reserved Reserved Coprocessor Fixed Disk Controller IRQ 0 IRQ 1 IRQ 2 IRQ 3 IRQ 4 IRQ 5 IRQ 6 IRQ 7 IRQ 8 IRQ 9 IRQ 10 IRQ 11 IRQ 12 IRQ 13 IRQ 14 IRQ 15 C T L R 2 Shaded Interrupts are supported by the 1784KT Interrupts IBM PC AT A

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 22 The following are registered trademarks of AllenBradley Company , Inc.: PLC, PLC2, PLC2/15, PLC3. The following are trademarks of AllenBradley Company , Inc.: Data Highway Plus, PLC5, ControlView , Interchange Compaq is a registered trademark of Compaq Computer Corporation. Dell is a registered trademark Dell Computer Corporation. HewlettPackard is a registered trademark of HewlettPackard Company . HP 9000 is a trademark of HewlettPackard Company

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 16 IBM PC A T System I/O Allocation W orksheet I/O Address IBM PC AT Assignments Y our System 0000FF System Board I/O 100 110 120 130 140 150 160 170 180 190 1A0 1B0 1C0 1D0 1E0 1F0 Fixed Disk Control 200 Game I/O 210 220 230 240 250 260 270 278 - 27F: Parallel Printer Port 1 280 290 2A02B0 2C0 2D0 2E0 2F0 2F8 - 2FF: Serial Port 1 300 310 320 330 340 350 360 370

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 15 IBM PC A T System Memory Allocation W orksheet System Memory IBM PC AT Assignments Y our System 0000:0000 07000:FFFF 512K Read/Write Memory on System Board 8000:0000 09000:FFFF 128K Read/Write Memory Expansion in I/O Channel  A000:0000 A400:0000 A800:0000 E.G.A. AC00:0000 B000:0000 B400:0000 Color/Graphics B800:0000 BC00:0000 C000:0000 C400:0000 C800:0000 CC00:0000 D000:0000 D400:0000 D800:0000

  • Communication Interface Module Cat. No. 1784KT/B Installation Data 3 ATTENTION: With any complex communication system you need to identify potential application-related communication problems and make provisions in the system design to prevent hazardous or undesired consequences if a problem occurs. These problems include, but are not necessarily limited to, t

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 14 Information is passed between the computer system and the 1784-KT through 2 Kbytes of memory located in the interface module. This 2 Kbyte memory is memory mapped into an open memory location in your computer system. The definition of “open” is a location that has not been configured for another optional interface card or system. The 1784-KT address decoding allocates a 16 Kbyte memory location. So, when selecting an open memory location, make sure there

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 20 Hardware Interrupt Allocation W orksheet IBM PC XT Interrupts IBM PC XT Assignments Y our System Shaded Interrupts are supported by the 1784KT IRQ 7 IRQ 0 IRQ 1 IRQ 2 IRQ 3 IRQ 4 IRQ 5 IRQ 6 Timer Keyboard COM2 COM1 Hard Disk Floppy Disk Printer

  • Allen-Bradley 1784-KT/B, Communication Interface Module Cat. No. 1784KT/B Installation Data 10 ATTENTION: To avoid personal injury, always disconnect the ac power before making the cable connection. Connecting Y our 1784KT to a PLC2 To connect the 1784-KT to a PLC-2, follow the steps below: 1. Plug the 62-pin connector end of the 1784-CP2 cable into the 1784-KT and secure with captive screws. 1784 - KT Board Program Panel" 1784 - CP2 Cable 16687a 2. Connect the opposite end of the 1784-CP2 cable into the PROGRAM PANEL connector on the PLC-2. 3. Reinstall the ac power

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 X10 WS13A Set up and operating instructions x10/ws13a-L6Q.pdf 21 Feb 2023 1 0.02 Mb
2 Fanimation FP8032SB Owner's manual fanimation/fp8032sb-46F.pdf 19 Feb 2024 16 3.52 Mb
3 Verizon Lucid User giude verizon/lucid-14B.pdf 20 Oct 2023 233 2.9 Mb
4 HP 20 MODULAR SMART ARRAY Operation & user’s manual hp/20-modular-smart-array-1PL.pdf 16 Mar 2023 45
5 Avanti BCA5102SS Instruction manual avanti/bca5102ss-BRW.pdf 01 Jun 2023 19 0.19 Mb
6 Directed Electronics 2 Owner's manual directed-electronics/2-16N.pdf 26 Dec 2023 52 5.61 Mb

Similar Resources:

  • ADTRAN

    Total Access 1100F

    (2 pages)
    Product Features Sealed GR-487 compliant unit Dual Optical GigE Networkfeeds  Networks with Total Access1124 or 1148 DSLAM for fiberdeployment 7 Gbps switching capacity Easily configurable for bothelectrical and optical expan-sion interfaces Priority Queuing (802.1p)  Integrated Security Support Replication of Multicast T …
  • Moxa Technologies

    EM-1240-LX

    (64 pages)
    EM-1240-LX User’s Manual www.moxa.com/product First Edition, November 2006 Moxa Systems Co., Ltd. Tel: +886-2-8919-1711 Fax: +886-2-8919-1722 Web: www.moxa.com Moxa Technical Support Worldwide: [email protected] The Americas [email protected]
  • YASKAWA

    SI-EN3

    (8 pages)
    SI-EN3 and SI-EN3/V EtherNet/IP Option Product Demonstration Unit Technical Manual Document: TM.AFD.08 12/28/2010 Rev: 10-12 …
  • Oakley

    MOTM-820

    (18 pages)
    Oakley Sound SystemsOakley Modular SeriesOMS-820 issue 2The MOTM-820 Companion ModuleUser’s GuideV2.01Tony Allgood B.EngOakley Sound SystemsCARLISLECA4 9QRUnited Kingdom1 …
  • Net to Net Technologies

    UIM-1000T

    (4 pages)
    UIM-1000T Gigabit Ethernet Uplink Interface Module 1.0 INSTALLATION 1.1 Unpack and Inspect the Equipment The following components should be included: If there is visible damage, do not attempt to install the UIM-1000T; contact Customer Support at 1-877-638-2638 (001-603-427-0600 for international customers) or [email protected]. 1.2 Inst …
  • Panasonic

    MA3X153A

    (3 pages)
    Switching Diodes1Publication date: February 2005 SKF00036DEDMA3X153 (MA153), MA3X153A (MA153A)Silicon epitaxial planar typeFor switching circuits■ Features• Small terminal capacitance Ct• Two diodes are connected in series in the package■ Absolute Maximum Ratings Ta = 25°CUnit: mmParameter Symbol Rating UnitReverse voltageMA3X153VR40VMA3X153A80Max …

Comments, Questions and Opinions: