  • REGULAR MAINTENANCE IS ESSENTIAL FOR MAXIMUM EFFICIENCY To ensure that your Breezair Evaporative Air Conditioner remains in first class working condition for many years, it should be thoroughly serviced twice a year. A service should be performed at the end of the summer season and prior to the commencement of the next summer season, by an authorised Breezair Se

  • Breezair 400 - 1500 Series, Pre-Season Maintenance Remove the cooling pad frames. Turn off the Isolating switch. Replace drain outlet removed at the end of the season maintenance, or close the drain shut off valve if fitted. Turn on the water supply. Check the float valve assembly for correct operation and setting of water level. Switch on the Isolating switch. Refit the pad frames. Run air conditioner for a period of time, check pads for a uniform saturation of water. Check the bleed off rate and set using the table on page 6 as a guide. Replacing the Filter Pads If, during your Pre-Season or End of Season maintenance you determine that

  • Breezair 400 - 1500 Series, TROUBLESHOOTING PROBLEM PROBABLE CAUSE SUGGESTED REMEDY Inadequate Cooling Insufficient air discharge openings. Make sure adequate openings Inadequate exhaust for area being are provided to exhaust the cooled, causing high humidity and incoming cool air, open windows, discomfort. doors etc. Undersized air conditioner. Replace with larger model. Clogged or dirty cooling pads. Clean or replace pads. Ducts blocked or collapsed Repair Ducts Dry pads or lack of water while Check water distribution system the air conditioner is operating. for obstructions. Check pump is operating.

  • Breezair 400 - 1500 Series, PROBLEM PROBABLE CAUSE SUGGESTED REMEDY Pump runs but does not Insufficient water in tank causing Adjust float level to increase water circulate water or pads pump to suck air. depth. lack water. Pump strainer clogged or dirty. Clean strainer. Blocked water supply tubing. Clean the tubing. Blocked water distributor at top Clean out the water trough. of pad frames. Continuous overflow of Incorrect float valve adjustment. Adjust float valve. water Inlet valve not sealing Replace valve Noisy air conditioner. Fan rubbing on housing. Reposition fan. Fan out of balance due to dirt, Clean fan, adjust blades if bent blade, etc. possible: Replace fan. Air conditioner deliver

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 BenQ MW821ST Operation & user’s manual benq/mw821st-L88.pdf 16 Dec 2022 60 5.34 Mb
2 Hotpoint BHWD 149 User manual manual hotpoint/bhwd-149-132.pdf 20 Jun 2023 20 0.41 Mb
3 Amana A9RXNMFW User instructions amana/a9rxnmfw-54O.pdf 16 Sep 2022 24 0.59 Mb
4 Altinex MULTI-TASKER MT110-101 Operation & user’s manual altinex/multi-tasker-mt110-101-N82.pdf 09 Jul 2023 26 0.77 Mb
5 Pass Laboratories X150 Owner's manual pass-laboratories/x150-YEH.pdf 26 May 2023 13 0.07 Mb
6 Lincoln Electric BULLDOG SVM208-A Service manual lincoln-electric/bulldog-svm208-a-97W.pdf 23 Aug 2022 101

Similar Resources:

  • Frigidaire

    FAA087S7AF

    (3 pages)
    |nstallation instructionsREAD BEFORE iNSTALLiNG UNiTMS II Window MountingYour air conditioner is designed to install in standarddouble hung windows with opening widths of 23 to 36inches (584 mm to 914 mm) (FIG. 1)Lower sash must open sufficiently to allow a clear verticalopening of 14 inches (356 mm). Side louvers and therear of the AC must have clear air sp …
  • Fujitsu

    ASTG18LF

    (20 pages)
    KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCEFUJITSU GENERAL LIMITEDOPERATING MANUALIndoor UnitASTG18LFASTG24LFASTG30LFASTG34LFAIR CONDITIONERWall Mounted TypeHEAT & COOL MODEL(REVERSE CYCLE)R410AREFRIGERANTThis Air Conditioner contains and operates with refrigerant R410A.THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICEDBY QUALIFIED PERSONNEL.Refer to Co …
  • Samsung

    AS09F Series

    (16 pages)
    '&$#20LHEPPULAEN KJ@EPEKJANĠ KKH*/45"--"5*0/."/6"-"4'74FSJFT"4'74FSJFT"4+74FSJFT"4+74FSJFT"4874FSJFT"4874FSJFT SH18BW6 IM_E_23998 2006.2.17 11:39 AM Page 17 …
  • LG

    LMNC182BHA0

    (45 pages)
    P/NO : 3828A20567Rwww.lg.comINSTALLATION MANUALAIR CONDITIONER • Please read this installation manual completely before installing the product.• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.• Please retain this installation manual for future reference after reading it thoroughly.T …
  • Fujitsu

    AUY36FUAS

    (26 pages)
    CONTENTSSPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3REFRIGERANT SYSTEM DIAGRAM . . . . . . . . . . . . . 5CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . 6ERROR CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . .8IN …
  • Fujitsu

    ASU30RLE

    (14 pages)
    En-1AIR CONDITIONERINDOOR UNIT (Wall Mounted Type)INSTALLATION MANUALContents1. SAFETY PRECAUTIONS .................................................................. 12. ABOUT THIS PRODUCT................................................................... 23. GENERAL SPECIFICATIONS ........................................................... 24. SELECTING …

Air Conditioner Instructions:

Comments, Questions and Opinions: