Text of Fujitsu Primergy CX400 S2 User Guide:

  • Fujitsu Primergy CX400 S2, 32 Operating Manual CX400 S2 Important information 4.5 Notes on installing the server enclosure in the rack V CAUTION! ● For safety reasons, at least two people are required to install the server enclosure in the rack because of its weight and size. (For the Japanese market, please refer to " 安全上のご注意 ".) ● Never lift the server enclosure into the rack using the handles. ● When connecting and disconnecting cables, observe the relevant instructions in the "Important Information" chapter of the operating manual for the corresponding rack. The operating manual is supplied with the corresponding rack. ● When installing the rack,

  • CX400 S2 Operating Manual 27 Important information ● Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth. ● Be careful not to damage the CD/DVD/BD surface. ● Ke

  • Fujitsu Primergy CX400 S2, 42 Operating Manual CX400 S2 Hardware installation 5.4.1 Securing the power cord Figure 5: Securing power cord Ê Loop the cable tie around the power cord and the handle of the power supply module (1). Ê Close the cable tie around the power cord (1) and pull tight (2) to secure the power cord.

  • 48 Operating Manual CX400 S2 Starting up and operation 6.1.2.2 CX400 S2 server enclosure with CX270 S2 server nodes Figure 9: PRIMERGY CX400 S2 server enclosure rear with CX270 S2 server nodes Pos. Component 1 Installation bay 1 for CX270 S2 server nodes 2 Installation bay 2 for CX270 S2 server nodes 3 Installation bay 1 for PSU 4 Installation bay 2 for PSU

  • CX400 S2 Operating Manual 43 Hardware installation 5.5 Notes on connecting/disconnecting cables V CAUTION! Always read the documentation supplied with the device you wish to connect. Never connect, or disconnect cables during a thunderstorm. Never pull on a cable when disconnecting it. Always take hold of the cable by the plug. Follow the sequence described

  • Fujitsu Primergy CX400 S2, CX400 S2 Operating Manual 37 Hardware installation 5.2 Installing/removing the server enclosure in/from the rack V CAUTION! ● Please observe the safety information and notes on rack mounting in chapter "Important information" on page 21 and section "Installing an additional server node to the server enclosure" on page 39. ● At least two people are needed to install / remove the server enclosure in the rack. (For the Japanese market, please refer to " 安 全上のご注意 ".) ● Do not extend more than one unit out of the rack

  • Fujitsu Primergy CX400 S2, CX400 S2 Operating Manual 33 Important information 4.6 Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Furt

  • Fujitsu Primergy CX400 S2, CX400 S2 Operating Manual 19 3 Installation steps, overview This chapter contains an overview of the steps necessary to install your server enclosure. Links take you to sections where you can find more detailed information about the respective steps: Ê First of all, carefully read the safety instructions in "Important information" on page 21. Ê Transport the server enclosure to the place where you want to set it up. Ê Unpack the system, check the contents of the package for visible transport damage and check whether the items delivered match the details on the delivery note (see section "Unpacking the server

  • Fujitsu Primergy CX400 S2, 16 Operating Manual CX400 S2 Functional overview Compliance with regulations and standards Product safety and ergonomics International IEC 60950-1 2ed; am1 Europe Safety EN 60950-1 2ed.; am1 EN 50371 EN 50392 Ergonomics ISO 9241-3 EN 2941-3 EK1-ITB2000:2013 USA / Canada CSA-C22.2 No. 60950-1-07 2ed. UL 60950-1 2ed. Taiwan CNS 14336 China GB 4943 Electromagnetic compatibility International CISPR 22 Europe EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3 ETSI 300386 USA / Canada 47CFR part 15 Class A / ICES-003 Taiwan CNS 13438 Class A China GB 9245 / GB 17625 Japan VCCI Class A / JEITA Korea KN 22 / KN

  • Fujitsu Primergy CX400 S2, 54 Operating Manual CX400 S2 Starting up and operation Switching the server node on Ê Press the On/Off button of the desired server node on the rear or on the front. Then the power-on indicator lights up green. – Starting up for the first time: For the Japanese market, please refer to " はじめにお読みください ". Ê Insert ServerView Suite DVD in the DVD drive. Ê Follow the on-screen instructions (for further details see Operating Manual of the installed server node). – System already installed: Ê The server node is switched on, performs a system test and boots the operating system. I In the case of configurations with a large memory size, the boot proc

  • Fujitsu Primergy CX400 S2, CX400 S2 Operating Manual 23 Important information V CAUTION! ● Ensure that the power sockets on the device and the properly grounded power outlets are freely accessible. ● The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the properly grounded power outlets. ● Always connect the server enclosure and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server e

  • Fujitsu Primergy CX400 S2, CX400 S2 Operating Manual 21 4 Important information In this chapter you will find essential information regarding safety when working on your server enclosure. 4.1 Safety instructions I The following safety instructions are also provided in the manual "Safety Notes and Regulations" or " 安全上のご注意 ". This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server enclosure in the intended environment, please con

  • Fujitsu Primergy CX400 S2, CX400 S2 Operating Manual 45 6 Starting up and operation V CAUTION! Please note the safety instructions in chapter "Important information" on page 21. 6.1 Overview of the server enclosure 6.1.1 Front overview Figure 6: Configuration with 24x 2.5" HDDs With CX250 S2 server nodes Pos. Component 1 Front panel module for server node 1 2 Front panel module for server node 2 3 Front panel module for server node 3 4 Front panel module for server node 4 5 24x 2.5-inch hard disk drives / trays

  • Fujitsu Primergy CX400 S2, CX400 S2 Operating Manual 9 Introduction 1.2 Documentation overview More information on your PRIMERGY CX400 S2 server node can be found in the following documents: – "Quick Start Hardware - PRIMERGY CX400 S2 Server Node" – "Quick Start Software - Quick Installation Guide" – "Safety Notes and Regulations" manual " 安全上のご注意 " for the Japanese market – "Warranty" manual " 保証書 " for the Japanese market – "Returning used devices" manual and "Service Desk" leaflet " サポート&サービス " for the Japanese market – "PRIMERGY CX400 S2 Server Node Upgrade and Maint

  • Fujitsu Primergy CX400 S2, 20 Operating Manual CX400 S2 Installation steps, overview Ê Configure the server enclosure and install the desired operating system and applications. The following options are available: – Remote installation with the ServerView Installation Manager: With the ServerView Suite DVD provided, you can configure the server enclosure and install the operating system in a convenient manner. Details on how to operate the ServerView Installation Manager, as well as some additional information, are included in the "ServerView Suite Installation Manager"

  • Fujitsu Primergy CX400 S2, CX400 S2 Operating Manual 35 5 Hardware installation V CAUTION! ● Follow the safety instructions in chapter "Important information" on page 21. ● Do not expose the server enclosure to extreme environmental conditions (see "Ambient conditions" on page 14). Protect the server enclosure from dust, humidity and heat. ● Make sure that the server enclosure is acclimatized for the time indicated in this table before putting it into operation. In the table "Acclimatization time", the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server enclosure was exposed prev

  • Fujitsu Primergy CX400 S2, 34 Operating Manual CX400 S2 Important information Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. Returns, recycling and disposal Please handle returns, recycling and disposal in accordance with local regulations. Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Cen

  • Fujitsu Primergy CX400 S2, Operating Manual CX400 S2 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused b

  • Fujitsu Primergy CX400 S2, Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to [email protected]. Certified documentation according to DIN EN ISO 9001:2008 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2008. cogni

  • Fujitsu Primergy CX400 S2, 56 Operating Manual CX400 S2 Starting up and operation 6.3 Cleaning the server enclosure V CAUTION! Switch the server enclosure off and disconnect the power plugs from the properly grounded power outlets. Do not clean any interior parts yourself; leave this job to a service technician. Do not use any cleaning agents that contain abrasives or may corrode plastic. Ensure that no liquid enters the system. Ensure that the ventilation areas of the server enclosure and the monitor are clear. Do not use any cl

  • Fujitsu Primergy CX400 S2, 26 Operating Manual CX400 S2 Important information Working with CDs/DVDs/BDs and optical drives When working with devices with optical drives, these instructions must be followed. V CAUTION! ● Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury. ● Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive. Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD an

  • CX400 S2 Operating Manual 11 2 Functional overview 2.1 Features This section provides information on the features and technical data of the PRIMERGY CX400 S2 server enclosure. For information on key characteristics and layout of the system board, see the "PRIMERGY CX400 S2 Server Enclosure Upgrade and Maintenance Manual". Server enclosure The PRIMERGY CX400 S2 server enclosur

Related Products and Documents (Enclosure):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Aprilaire 350 Owner's manual aprilaire/350-X62.pdf 03 Nov 2022 11 0.87 Mb
2 Philips DVP3050V Software upgrade instructions philips/dvp3050v-KIV.pdf 11 Nov 2023 2 0.03 Mb
3 Frigidaire PLEFMZ99ECG Service data sheet frigidaire/plefmz99ecg-68E.pdf 26 Mar 2023 2
4 Makita ML702 Instruction manual makita/ml702-L42.pdf 05 Mar 2023 12
5 StarTech.com STUTPEALR Manual  startech-com/stutpealr-168.pdf 05 Aug 2022 13
6 Novell GROUPWISE 7 - SECURITY POLICIES Installation instructions manual novell/groupwise-7-security-policies-253.pdf 19 Jul 2022 34

Similar Resources:

  • Gumdrop

    SlimTech

    (2 pages)
    INSTALLATION2 Pop on the side clips. Make sure the keyboard is flush against the front edge of the bottom case.3 Carefully press the rear corner clips to snap onto the keyboard.4Align the device screen under the top case’s side clips on both sides.5Slide the top case down, to secure the screen behind the side clips, until the device reaches the case’s to …
  • GE

    EntelliGuard GBKRKR

    (4 pages)
    1 Introduction Key Interlock Kit: The breaker key lock is an optional accessory, which will keep the breaker in trip free state while locked. Maximum 4 keys of Ronis/Profalux or Kirk type can be used. All EntelliGuard Devices can be equipped with one of the three locks, that when fitted as indicated allow the use of one to four key locks that lock the d …
  • Hoffman

    CONCEPT CDSC24268LG

    (20 pages)
    For Variable Depth Disconnect DevicesAnd For Flexible Cable Disconnect DevicesIn Hoffman Bulletin CWY (painted steel)Or Hoffman Bulletin CWSD (stainless steel)CONCEPT® Wall Mounted Disconnect Enclosures87568832Rev. B 113357 P/N 64323101 2005 Hoffman Enclosures Inc.®RSPSupply - 1-888-532-2706 - www.RSPSupply.comhttp://www.RSPSupply.com/p-16178-Hoffman- …
  • Siemens

    TH 180 AP

    (3 pages)
    Installation InstructionsDocument No. 129-102March 6, 2018Installation of TH 19X Thermostat inTH 180 AP and TH 182 AP AspiratorWall BoxItem Number 129-102+4, Rev. BA Page 1 of 3Product DescriptionThese instructions describe the recommendedmethod for replacing the thermostat in theTH 180 AP or TH 182 AP Aspirating Wall Boxwith a TH 19X Thermostat using the 19 …
  • AirLive

    WMU-6000FS

    (58 pages)
    Quick Setup Guide WMU-6000FS Portable Wireless AP Storage English ● ● ● Español ● ● ● Русский ● ● ● Português ● ● ● Deutsch ● ● ● Slovensky ● ● ● Česky ● ● ● 日本語 ● ● ● 43 29 36 15 22 1 8 50 …
  • Miranda

    densite series

    (45 pages)
    DENSITÉ series DCO-1741 / DCO-1781 2/4 AES Changeover Guide to Installation and Operation M879-9900-100 16 Sep 2008 Miranda Technologies Inc. 3499 Douglas-B.-Floreani St-Laurent, Québec, Canada H4S 1Y6 Tel. 514-333-1772 Fax. 514-333-9828 www.miranda.com © 2008 Miranda Technologies Inc …

Comments, Questions and Opinions: