Gentex 700 SERIES Installation Instructions Manual
|
Gentex 700 SERIES, 700 SERIES INTRODUCTION 700 SERIES The 713 Series smoke alarm is a photoelectric type smoke alarm for use as an evacuation device in residential applications, while the 710 and 720 Series are for use as an alert and relocate device. Each device has a solid state piezo signal to warn and alert the household to the presence of threatening smoke. The 710CS and 710CSX Series has a solid state piezo as well as a visual signal to warn and alert the hearing impaired to the presence of threatening smoke. Your photoelectric smoke alarm is designed to detect the smoke that results from an actual fire. Consequently, it is uncommon for household smoke
Gentex 700 SERIES, Keep electrical appliances and cords in good working order and do not overload electrical circuits. Keep stoves, fireplaces, chimneys, and barbecue grills grease-free and make sure they are properly installed away from combustible materials. Keep portable heaters and open flames such as candles away from combustible materials. Do not allow rubbish to accumulate. Do not leave small children home alone. c. Develop a family escape plan and practice it with your entire family, especially small children. Draw and post a floor plan of your home and find two ways to exit from each room. There should be one way to get out
Gentex 700 SERIES, NFPA 72, 2010 Edition, Chapter 29, Section 29.5.1 Required Detection, states the following: 29.5.1.1 Where required by applicable laws, codes or standards for a specific type of occupancy, approved single and multiple-station smoke alarms shall be installed as follows: 1) In all sleeping rooms and guest rooms 2) Outside of each separate dwelling unit sleeping area, within 6.4m (21ft) of any door to a sleeping room, the distance measured along a path of travel 3) On every level of a dwelling unit, including basements 4) On every level of a residential board and car
Gentex 700 SERIES, The placement of the smoke alarm is critical if maximum speed of fire detection is desired. Thus, a logical location for a smoke alarm is the center of the ceiling. At this location, the device is closest to all areas of the room. WHERE SMOKE ALARMS SHOULD BE INSTALLED IN MOBILE HOMES In mobile homes built after about 1978 that were designed and insulated to be energy-efficient, smoke alarms should be installed as described in the section above. In older mobile homes that have little or no insulation compared t
WIRING TWO OR MORE SMOKE ALARMS Tandem Installation NOTICE: ALL SMOKE ALARMS IN A TANDEM INSTALLATION MUST BE CONTROLLED BY THE SAME FUSE OR CIRCUIT BREAKER. OTHERWISE TANDEM UNITS WILL NOT OPERATE. LIMITATIONS: A maximum of 12 smoke alarms ("710/713" or "720") may be connected together. Do not exceed 125 feet between each smoke alarm. Do
Gentex 700 SERIES, 6. Allow smoke alarm to soak for approximately 10 minutes (longer if extremely dirty). Then agitate for 5 or 10 seconds to flush out any remaining dirt left inside unit’s housing. 7. Remove smoke alarm from wash water and transfer directly to one of the first rinse buckets containing clear water. Again, allow smoke alarm to become completely submerged, agitate once more for 5 or 10 seconds to remove soap residue. 8. Finally, transfer smoke alarm to your second and final rinse bucket, repeating method found in Step 7, then remove smoke alarm to a clean dry ar
DOWNLOAD |
BRK electronic Smoke and Carbon Monoxide Alarm SC01N Smoke Alarm Operation & user’s manual
Smoke and Carbon Monoxide Alarm SC01N |
Gentex 700 SERIES Smoke Alarm Installation instructions - owner's information
700 SERIES |
Siemens FDOOT241-9 Smoke Alarm Technical manual
FDOOT241-9 |
Gentex 9000 SERIES Smoke Alarm Installation instructions manual
9000 SERIES |
Firex CC Smoke Alarm Owner's manual
CC |
Eagle Home Products Eagle Series Smoke Alarm Instruction manual
Eagle Series |
System Sensor 2100AT Smoke Alarm Installation and maintenance instructions
2100AT |
Gentex 710LS Smoke Alarm Installation instructions
710LS |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Mopar | 82208859 | Installation instructions manual | mopar/82208859-AS8.pdf | 16 Nov 2023 | 34 | |
2 | Black & Decker | LST400 | Instruction manual | black-decker/lst400-5F9.pdf | 06 Feb 2024 | 36 | |
3 | Atlantis Land | NetFly Omni A02-ANT0501 | Specification sheet | atlantis-land/netfly-omni-a02-ant0501-74H.pdf | 02 Mar 2024 | 2 | 0.14 Mb |
4 | JAI | TS-2076EN Series | Operation & user’s manual | jai/ts-2076en-series-T7A.pdf | 06 Sep 2022 | 64 | |
5 | Philips | 150B6CS | Specifications | philips/150b6cs-1C5.pdf | 04 Aug 2023 | 3 | 0.54 Mb |
6 | Samsung | Galaxy S7 | Operation & user’s manual | samsung/galaxy-s7-498.pdf | 14 Jan 2023 | 233 |
Kidde
Why Wireless?wireless systemAC Powered Smoke AlarmMakes it easy to expand the coverage of a current interconnected system.Wireless AC Powered Smoke AlarmThe Kidde Wireless AC Powered Smoke Alarm makes iteasy to expand the coverage of a current interconnectedsystem. Simply replace one interconnected smoke alarmwith the Kidde Wireless AC powered alarm. Kidde W …
Smoke Alarm(2 pages) |
Optex
SX-360Z, SX-360ZV360° CEILING MOUNT PASSIVE INFRARED DETECTORINSTALLATION INSTRUCTIONS-1--4-360° CEILING MOUNT PASSIVE INFRARED DETECTORSX-360Z, SX-360ZVINSTALLATION HINTS1DETECTION AREA2SPECIFICATIONS12FEATURESCeiling mount 360° PIR detectorZoom area adjustment : ø18 m (ø60 ft.) at 2.4 –5.0 m (8 –16 ft.)High density detection area with 276 zonesSel …
SX-360Z(2 pages) |
Simplex
Features Releasing control using the Simplex® 4100ES (or 4100U) Fire Alarm Control Panel to provide**: Coverage for multiple areas of Automatic Extinguishing Release and/or Deluge and Preaction Sprinkler System Release including audible escalation of events Control of compatible Listed/Approved 24 VDC automatic control actuators, one per circuit …
4100ES(8 pages) |
Silent Call Communications
1ETLus ListedPatents Pending. All Rights Reserved.Photoelectronic Smoke Detector with Built-in Wireless TransmitterModel # SD4-SSINSTALLATION ANDOPERATION MANUAL
…
SD4-SS(28 pages) |
LST
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVEDBC016-1_DBL_LST_EN_0804.PDF • PAGE 1ABuilding Safety. Building Security. F ire Detection Control PanelBC016-1• For application in small and mid-sized systems• Addressable …
BC016-1(3 pages) |
Firehawk
FHH10WREAD AND RETAIN THIS USER MANUAL5. TESTING THE SYSTEMTest the full system using the test button of the alarms and or Deaf Alerts if fitted.1. Undo the alarm from the pattress without disconnecting the wires and permanently attach it to the chosen location. See sec 4 para 2 above.2. Fit all alarms to their own Radio Pattresses by lining up as shown …
FHH10W(2 pages) |
Fellowes Binding Machine Galaxy e 500Galaxy e 500 Operation & user’s manual - A185ZJ Galaxy e 500, 4 |
Whirlpool Dryer 3405792Whirlpool Dryer 3405792 Use and care manual 3405792, 56 |
NTI Media Converter SVCV-DVI-FOSCNTI SVCV-DVI-FOSC User Manual (Operation & user’s manual), @8RF27E SVCV-DVI-FOSC, 9 |
Rii Keyboard K03BTUser Guide: Rii K03BT (59341D, Upd.27.01.2024) K03BT, 14 |
Toshiba TV 32WL48PService manual for Toshiba 32WL48P TV 32WL48P, 101 |
AOR Radio ARD300AOR ARD300 Radio Operation & user’s manual ARD300, 28 |
Directed Electronics Crossover 202User Guide: Directed Electronics 202 (7J2138, Upd.18/12/2023) 202, 5 |
Hitachi Power Tool CJ 110M#AP2O7B: CJ 110M Power Tool Handling instructions manual CJ 110M, 12 |
Frigidaire Refrigerator FRTX18N5BW2#VSFR14 FRTX18N5BW2: Frigidaire Refrigerator Owner Documentation FRTX18N5BW2, 2 |
Asus Motherboard P5B-MX - Motherboard - Micro ATXAsus Product Manual: P5B-MX - Motherboard - Micro ATX PDF Operation & user’s manual - 15G5U4 P5B-MX - Motherboard - Micro ATX, 94 |
Sky+HD Set-top boxes DRX895WSky+HD DRX895W Guide (Doc Type: Set-top boxes Operation & user’s manual) DRX895W, 130 |
Digital View DVR NW-STA-5016Digital View NW-STA-5016 User Manual (Operation & user’s manual), @176C5J NW-STA-5016, 56 |