Manualios.com

Brocade Communications Systems LS-STK Installation Manual

Brocade Communications Systems LS-STK Manual Online:

3.8, 2383 votes
Brocade Communications Systems LS-STK User Manual
Brocade Communications Systems LS-STK User Guide
Brocade Communications Systems LS-STK Online Manual

Text of Brocade Communications Systems LS-STK User Guide:

  • Brocade Communications Systems LS-STK, 34 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 Upgrading hardware DRAFT: BROCADE CONFIDENTIAL FIGURE 31 Replacing the memory DIMM 11. Install the CX4 module in the slot in the rear panel, if necessary. 12. Replace the cover as follows: • Hold the cover on each side at the center and align the front of the cover with the end of the serial interface on the front panel, so that the cover extends slightly past the front panel of the device. • Slide the cov

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 23 53-1002187-01 Installing a redundant power supply 2 DRAFT: BROCADE CONFIDENTIAL 5. To connect additional RPS devices, first disconnect the original RPS device from the AC power supply, then follow steps 1, 2, 4 and 5. DANGER Once the RPS device is disconnected from the AC power supply, the RPS device will no longer provide redundant power until after the additional RPS devices are installed, the AC power is reconnected, and the RPS device completes the self-test procedure. 6. Check the LEDs on the RPS device to ensure proper op

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 3 53-1002187-01 Hardware features 1 DRAFT: BROCADE CONFIDENTIAL • Optional 10 Gbps uplink modules (not available for FastIron LS 648-STK models) For information about the type of fiber optic modules supported, see “Fiber optic modules” on page 7. FastIron LS and LS-STK 10/100/1000BASE-T ports FLS and FLS-STK devicees contain 24 or 48 ports that operate at 10 Mbps or 100 Mbps, half or full duplex, or at 1000 Mbps, full duplex. Because all ports on these devicees support automatic MDI/MDI-X operation, you can use straight-through cables for all network connections to PCs or servers, or to other devicees o

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 49 53-1002187-01 DRAFT: BROCADE CONFIDENTIAL Chapter 5 Maintaining the FLS and FLS-STK Hardware Managing FastIron LS temperature settings DANGER The procedures in this manual are for qualified service personnel. This section describes how to display temperature settings on FastIron LS devices, and how to change the temperature warning and shutdown levels. NOTE Maintenance functions for FLS-STK devices that are part of an IronStack are done through the console connection on the Active Controller for the stack. You c

  • Brocade Communications Systems LS-STK, 12 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 Installation precautions 2 DRAFT: BROCADE CONFIDENTIAL Lifting precautions DANGER Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over. DANGER Mount the devices in the lowest possible slots in a rack or cabinet. Place the heaviest device at the bottom and progressively place lighter devices above. Power precautions CAUTION Use a separate branch circuit for each AC power cab

  • Brocade Communications Systems LS-STK, 4 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 Hardware features 1 DRAFT: BROCADE CONFIDENTIAL 10 Gbps Ethernet module slots for standalone devices FLS 624 and FLS 648 standalone devices include two slots on the rear panel for single-port 10GBASE uplink modules with XFP transceivers, and a single port CX4 module. The 10GBASE transceivers operate at 10 Gbps full duplex with support for asymmetric flow control (that is, the port honors incoming pause frames, but does not originate pause frames). 10 Gbps Ethernet module slots for stacking devices FLS 624-STK and FLS 648-STK dev

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 43 53-1002187-01 Configuring IP addresses 4 DRAFT: BROCADE CONFIDENTIAL FIGURE 32 UTP crossover cable FIGURE 33 Straight-through cable Connecting to workstations, servers, or routers Straight-through UTP cabling is required for direct UTP attachment to workstations, servers, or routers using network interface cards (NICs). Fiber cabling is required for direct attachment to Gbps NICs or devicees and routers through fiber ports. See “Connecting a network device to a fiber port” on page 44. Automat

  • 58 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 Diagnosing device indicators 6 DRAFT: BROCADE CONFIDENTIAL In-band access You can access the management agent in the device from anywhere within the attached network using Telnet, a Web browser, or other network management software. However, you must first configure the device with a valid IP

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 39 53-1002187-01 Configuring IP addresses 4 DRAFT: BROCADE CONFIDENTIAL Configuring IP addresses You must configure at least one IP address using the serial connection to the CLI before you can manage the system using the other management interfaces. For devices in an IronStack, you will need to configure a common IP address for the entire stack. For information about how to do this, see the FastIron Configuration Guide. Brocade devices support both classical IP network masks (Class A, B, and C subnet masks, and so on) and Classless

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 5 53-1002187-01 Hardware features 1 DRAFT: BROCADE CONFIDENTIAL FIGURE 7 CX4 transceiver cable FIGURE 8 CX4 slide-in transceiver Port, system, and module status LEDs FastIron LS and LS-STK devices include key system and port indicators to simplify installation and network troubleshooting. These LEDs, located on the front panel for easy viewing, are shown in Figure 9 and described in the following tables. FIGURE 9 Port status LEDs 1 Port status LED TABLE 2 Port status LEDs LED Status Status Link/ Activity or Speed On or Flashing Amber Port has a valid link at 10 o

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 71 53-1002187-01 DRAFT: BROCADE CONFIDENTIAL Appendix A Regulatory Statements USA (FCC CFR 47 Part 15 Warning) This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructi

  • Brocade Communications Systems LS-STK, 72 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 Japan power cord A DRAFT: BROCADE CONFIDENTIAL English translation of above statement This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Japan power cord English translation of above statement ATTENTION: Never use the power cord packed with your equipment for other products. Kor

  • Brocade Communications Systems LS-STK, 20 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 Installing a redundant power supply 2 DRAFT: BROCADE CONFIDENTIAL • The site should: • Be at the center of all the devices you want to link and near a power outlet. • Maintain temperatures within 0 to 50 °C (32 to 121 °F) and humidity levels within 5% to 95%, non-condensing • Provide adequate space (approximately two inches) on all sides for proper air flow • Be accessible for installing, cabling, and maintaining the devices • Allow the status LEDs to be clearly visible • Allow twisted-pair cable to always be routed away from power lines, fluorescent lighting fixtures and other sources

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 75 53-1002187-01 DRAFT: BROCADE CONFIDENTIAL Appendix B Caution and Danger Notices The caution and danger notices that appear in this manual are listed below in English, German, French, and Spanish. Caution A caution calls your attention to a possible hazard that can damage equipment. “Vorsicht” weist auf die Gefahr einer möglichen Beschädigung des Gerätes in. Une mise en garde attire votre attention sur un risque possible d'endommagement de l'équipement. Ci-dessous, vous trouverez les mises en

  • Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 11 53-1002187-01 Installation precautions 2 DRAFT: BROCADE CONFIDENTIAL Installation precautions Follow these precautions when installing a Brocade device. General precautions DANGER All fiber optic interfaces use Class 1 lasers. CAUTION Do not install the device in an environment where the operating ambient temperatu

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 55 53-1002187-01 Cabling a fiber optic module 5 DRAFT: BROCADE CONFIDENTIAL 4. Pull the bail latch on the module forward and away from the module. This unlocks the module from the front panel. NOTE The bail latch may be attached to either the top or the bottom of the mini-GBIC. 5. Grasping the bail latch, pull the fiber optic module out of the port. 6. Store the fiber optic module in a safe, static-free place or in an anti-static bag. 7. Install a new fiber optic module in the port.

  • Brocade Communications Systems LS-STK, 6 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 Hardware features 1 DRAFT: BROCADE CONFIDENTIAL FIGURE 10 System status LEDs 1System status LED TABLE 3 System status LEDs LED Condition Status Power Green Internal power is operating normally. Amber Internal power supply failure. Off Power off or failure. Diag Green System self-diagnostic test successfully completed. Amber System self-diagnostic test has detected a fault. RPS Green Redundant power supply is providing power. Amber Primary power supply is active, RPS is on

  • 24 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 Installing a redundant power supply 2 DRAFT: BROCADE CONFIDENTIAL Ports pin-out (RPS2-EIF) TABLE 9 Port pin-outs - RPS2-EIF Pin Name Description 1, 7, 8, 14 GND Ground connection 2, 9 N.C. No current 3, 4, 5, 6 12 V 12 volts current 10 RPS Present Indicates that an RPS device is atta

  • viii Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 DRAFT: BROCADE CONFIDENTIAL . Command syntax conventions Command syntax in this manual follows these conventions: Notes, cautions, and danger notices The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE

  • Brocade Communications Systems LS-STK, 60 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 53-1002187-01 FastIron LS and LS-STK specifications 7 DRAFT: BROCADE CONFIDENTIAL Operating environment Table 18 lists the operating environment specifications for FastIron LS and LS-STK devices. Storage environment Table 19 lists the storage environment specifications for FastIron LS and LS-STK devices. Mean Time Before Failure Table 20 provides the initial MTBF result for the FastIron LS (including the power supply). AC power supply compatibility matrix Table 21 lists the FastIron Products and AC re

  • Brocade Communications Systems LS-STK, Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide 73 53-1002187-01 Regulatory compliance A DRAFT: BROCADE CONFIDENTIAL Regulatory compliance Table 31 lists the Electromagnetic Compatibility (EMC), Immunity standards, and safety agency approvals for the FastIron family of devicees. . TABLE 31 Regulatory Compliance and Safety Approvals Certifications Emissions: • ICES-003, Electromagnetic Emission • FCC Part 15 Class A • EN 55022/CISPR 22 Class A • VCCI Class A • EN 61000-3-2, Power Line Harmonics • EN 61000-3-3, Voltage Fluctuation & Flicker • EN 61000-6-3, Electromagnetic Compatibility, Generic Standard • AS or NZS CIS

Related Products and Documents (Modem):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Coby CA-745 Instruction manual coby/ca-745-QE5.pdf 24 Sep 2023 1 0.77 Mb
2 Listen Technologies LA-107 Operation & user’s manual listen-technologies/la-107-5OB.pdf 31 Jul 2023 16
3 GoPro Hero 3 Black edition Quick start manual gopro/hero-3-black-edition-117.pdf 03 Apr 2023 14 0.53 Mb
4 ZuumMedia HE2IR-TX Operation & user’s manual zuummedia/he2ir-tx-2Q2.pdf 20 Dec 2023 12
5 Kettler Mondeo Brochure kettler/mondeo-GG7.pdf 14 Nov 2022 1
6 Rime Lite SWING II Operation & user’s manual rime-lite/swing-ii-7AN.pdf 16 Nov 2022 7

Similar Resources:

  • Arris

    Touchstone WBM650

    (29 pages)
    Safety Getting Started Installation Usage Troubleshooting Glossary Touchstone® WBM650 Wideband ModemUser’s Guide Get ready to experience the Internet’s express lane! Whether you are checking outstreaming media, downloading new software, or checking your email, the Touch-stone® WBM650 Wideband Modem brings it all to you faster and more reliably. Theh …
  • Zte

    MF636

    (14 pages)
    1 USB Modem Introduction 1.1 Introduction Thank you for choosing the ZTE MF636 USB modem. Please read this manual carefully and keep it for future reference. The pictures, symbols and contents in this manual are for reference only. They are correct at the time of publication but might not be completely identical with your modem. We operate a policy of contin …
  • Black Box

    ME758C-RJ11

    (9 pages)
    Power-TD-RD-RTS-CD-ERRORMulti-FunctionLDCardME758C-RJ11MAIN MODULE1 2 3 4 5 6 7 8ONMAIN MODULE(FRONT CARD)ME758C-RJ11JB4 1 2 3INTERFACE MODULE(REAR CARD)Line: RJ-11INTERFACEMODULE(REAR CARD)Analog511511ETEST -Remote1 2 3 4 5 6 7 8ON1 2 3 4 5 6 7 8This switch is onthe bottom side ofcardONJB3 1 2 3JB2 1 2 3DB25FEMALECONNECT …
  • TP-Link

    TD-W8960N

    (24 pages)
    1 Please use only wired network connections to configure the Router. Power down all of your network devices, including your computer(s) and the Modem Router. If you currently use a modem, disconnect it now - the Modem Router will replace your current modem. Connect your computer to the LAN port on the Modem Routerwith an Ethernet cable. Connect the …
  • Elcon

    Elconnect next EAD 100w

    (36 pages)
    next EAD 100w Ethernet Access Device Kurzbedienungsanleitung Short Operating Instructions © ELCON Systemtechnik GmbH 2013 Art.-Nr. 102686-2 …
  • Sprint

    OVATION U727

    (1 pages)
    Sprint Mobile Broadband USB Modem by Novatel Wireless Ovation™ U727 WINDOWS Quick Start Sheet Detailed instructions on installation, activation, and basic information on using the device are in the comprehensive Quick Start Guide booklet that was included in the product packaging and is also available online at www.sprint.com/downloads. 1. Setup an acco …

Comments, Questions and Opinions: