  • ETERNITY G16, 1. 2. 3. DO NOT HANG WASHING OR OTHER MATERIALS ADJACENT TO THE UNIT. DO NOT STORE INFLAMMABLE MATERIALS WITHIN 2 METERS OF THE UNIT. DO NOT TOUCH THE FLUE OUTLET OF THE UNIT DURING OR IMMEDIATELY AFTER OPERATION. IF ANY GAS SMELL COMES FROM THE UNIT, DO NOT USE NAKED FLAMES TO TEST FOR GAS LEAKS. TURN OFF THE GAS SUPPLY AND POWER AND CONTACT YOUR GAS SUPPLY COMPANY. 6. IF A POWER FAILURE OCCURS THE REMOTE CONTROLS WILL NOT FUNCTION AND THE CHOFU UNIT WILL NOT SUPPLY HOT WATER UNTIL POWER IS RESTORED. WHEN POWER IS RESTORED THE REMOTE CONTROLS WILL RESET AT 42°C AS A SAFE TEMPERATURE. PLEASE NOTE 4. 5. CARE OF THE ETERNITY UNIT 18

  • Close Prohibited No Fire POINTS NEEDED FOR YOUR SPECIAL ATTENTION ,L Danger NO INSTALLATION INDOORS (May cause oxygen deficiency accident or incomplete combustion.) The unit is outdoor installation type. Never install indoor or in the bathroom. It will be extremely dangerous since it will cause oxygen deficiency and incomplete combustion. Prohibited ,AWarning WATCH FOR GAS LEAK May cause fi

  • ETERNITY G16, 1.1 TECHNICAL DATA AND DIMENSIONS ETERNITY 16 / 20 / 26 Nominal hourly gas consumption MJ/h  MODEL 16 20 26 by proportional electronic gas control  MJ/h  125 160 200 Test point pressure  MODEL NG LP Water heating capacity raised 40°C  MODEL 16 20 26 ML/M 10 12.5 16.25 Working pressure  Max 1200kPa Gas injectors of the following size in mm  MODEL NG LPG MODEL NG LPG are fitted for the approved gas types  16/20 1.35 1.35 mm 26  1.34 1.0mm  1.65 1.65 mm  1.65 1.2 mm Input volta

  • ETERNITY G16, ORO. IN c-1 ,[71• H , a TERMINALS FOR REMOTE CONTROLS CABLE CLAMP -1aPj=f, I o CABLE ENTRY PORT REMOTE CONTROLS CABLE ANTI-FREEZE HEATER WIRING DIAGRAM OF PCB TURN OFF POWER SUPPLY TO HOT WATER UNIT AND REMOVE PLUG FROM POWER OUTLET BEFORE REMOVING FRONT COVER OF HOT WATER UNIT. WIRING FROM MAIN UNIT TO MAIN & SHOWER/SUB REMOTE CONTROLS MAIN CONTROL SHOWER CONTROL 240volt POWER SUPPLY SUB CONTROL (ENSUITE) 1 REMOTE CONTROLS WIRING DIAGRAM 10

  • ETERNITY G16, MOUNTING AND WIRING OF REMOTE CONTROLS 4.7 REMOTE CONTROLS OPEN THE CARTON BOX AND MAKE SURE TO CHECK FOLLOWING PARTS PROVIDED. • MAIN CONTROLS MODEL CMR-154 ,,,--- j------------- V 01" \--,_____ 2PCS 2PCS REMOTE CONTROLS WOOD SCREW CURL PLUG WIRING • SHOWER/SUB CONTROLS MODEL YST-84 / YST-84S '''' 1111'11 '11A -.•- c r 2PCS 04" 2PCS 41111° 2PCS REMOTE CONTROLS WOOD SCREW CURL PLUG CONNECTOR (C :1D --- 4 ‘-----__  _____,-, WIRING CABLE CLAMP MOUNTING REMOTE CONTROLS 13

  • ETERNITY G16, Warranty Terms Eternity Water Heaters are covered by Eternity for any cost of labour and parts in the event of a component failure due to any defects that may arise either from workmanship and or faulty material. The Warranty commences on the date of Installation: Domestic Appliance Eternity Product Heat Exchanger Parts 10 Years Labour 3 Years All Other Parts .  Parts 3 Years Labour 3 Years Commercial Application Eternity Product Heat Exchanger Parts 5 Years Labour 1 Year All Other Parts Parts 1 Year Labour 1 Year Definition of Domestic Use: 1. Units installed in any domestic dwelling. 2. Units installed in any gas boosted solar system in a domestic dwelling. 3.

  • ETERNITY G16, SHOWER / SUB REMOTE CONTROLS YST-84 /YST-84S 16 C ALM (.„ LA [ AM rf TI PM Li LI •nrit • LI 11 Pt 1 Ell In r--- , . . . TRANSFE1 11 nn ILM f: - -- °11 BATHROOM , ON/OFF YST-84 o.... O.:': Fa sa-ery erd pew usg Ice areto rend  te.e.e. Arremox 11.02.Mry cacd,,,:edetrk,i, PM,. *arr. xla 7 3-A 3 4 5 3-B 2 (ILLUSTRATION IS FOR YST-84) NOS. CONTROL 1  DIGITAL DISPLAY 2 TEMPERATURE CONTROL 3 TRANSFER SWITCH (GREEN) 3-A TRANSFER INDICATOR (GREEN) 3-B TRANSFER INDICATOR (GREEN "T" LAMP) 4  ON INDICATOR(GREEN) 5  ON/OFF SWITCH 6 COMBUSTION LAMP(RED) 7 ALARM LAMP(RED) FUNCTION INDICATES

  • ETERNITY G16, COLD WATER CONNECTION 1.9 COLD WATER SUPPLY TO WATER HEATER Refer to the Technical Sheet for the position of connections. Minimum of 13mm for model 16/20 and 18mm for model 26 copper tube should be connected to the appliance . The WATER INLET connection are 13mm BSP for model 16/20 and 18mm BSP for model 26 and requires a union to allow for removal of the water heater. Pipe sizing from the cold water supply should be sized according to local BY LAWS for water supply. ISOLATING GATE VALVE or BALL VALV

  • ETERNITY G16, Refer to Technical Sheets 4.0 The ETERNITY 16/20/26 comes complete, with one, two or three remote control panels, as optional extras. ONE REMOTE CONTROLS SYSTEM MODEL CMR-154 MAIN CONTROLS TWO OR THREE REMOTE MODEL CMR-154 MAIN CONTROLS CONTROLS SYSTEM MODEL YST-84 SHOWER CONTROLS MODEL YST-84S ENSUITE CONTROLS 4.1 These controls are to be fitted in the following locations: * MAIN CONTROLS-kitchen or laundry * SHOWER CONTROLS-main bathroom IMPORTANT DO NOT locate the remote controls where they may come into contact with water. DO NOT position the remote controls in the vicinity of chemicals. DO NOT position the remote controls over a cooker, grill oven or toaste

  • HOT WATER CONNECTION 2.0 Refer to Technical Sheet for the position of connection. The outlet connection is 13mm for model 16/20 and 18mm for model 26 male thread and requires an isolating union to allow for removal of the unit. 2.1 Install the hot water supply line to the unit in a minimum of 13mm for model 16/20 and 18mm for model 26 copper tube. for units set at 50°C this mus

  • ETERNITY G16, 1.4 HEATER DIMENSIONS:  DEPTH 165mm WIDTH 350mm HEIGHT 575mm 1.5 WARNING LABELS Located on the side of the cabinet. PLEASE READ THESE LABELS CAREFULLY. 1.6 INSTALLATION POSITION THIS HEATER IS APPROVED FOR OUTDOOR INSTALLATION ONLY-IT IS NOT SUITABLE FOR INDOOR USE. Refer AS5601 for clearance details for flue terminal. In addition,ensure that the appliance installation position permits easy access for maintenance and operation. For further infomation,please refer to the Gas Fitting Regulations. 1.7 POSITION FOR INSTALLATION The heater must be installed by using a fi

  • ETERNITY G16, Caution DANGER OF WET HANDS  INSERT POWER PLUG PROPERLY INTO (May cause electric shock.)  TERMINAL Do not touch power plug with wet hands. It is dangerous, because it can cause electric shock. Check the power plug for dust accumulation, then properly insert to the power point. DO NOT PULL POWER CORD (May generate heat and cause fire.) DO NOT USE POWER CORD BUNDLED (May generate heat and cause fire.) Do not turn off the power plug by pulling the cord. It may generate heat by wire breakage then cause fire.

  • III J / o0 igo IN MirMaCEMIVACIBil - 11E111 U I a 0 0 NOS. PARTS DESCRIPTION 1 FLUE OUTLET 2 GAS VALVE 3 CIRCUIT BOARD 4 BURNER CASE 5 HOT WATER OUTLET 6 COLD WATER INLET 7 GAS SUPPLY INLET 8 HEAT EXCHANGER NOS. PARTS DESCRIPTION 1 FLUE OUTLET 2 GAS VALVE 3 CIRCUIT BOARD 4 BURNER CASE 5 HOT WATER OUTLET 6 COLD WATER INLET 7 GAS SUPPLY INLET 8 HEAT EXCHANGER 9 WA

  • Warning NO DISASSEMBLY, REPAIR OR MODIFICATION (May cause fire, electric shock or other accidents.) 414 No Disassemble r  0 ,3 CJ Do not dissemble or modify the units. Never fail to ask professional assistance from the dealer you have bought your unit from for such a case as installation, removing, auxiliary installation work or connection to the solar units. CAUTION FOR

  • ETERNITY G16, FAULT MONITOR THE ETERNITY HOT WATER UNIT HAS A SELF DIAGNOSING FUNCTION FOR FAULTS. When the unit does not operate correctly, an error code is displayed on the MAIN and SHOWER remote controls TEMPERATURE DISPLAY INDICATOR. The cause of the fault can be determined after checking the fault numbers display on the remote control display. DISPLAY PROBLEM REMEDY 11 GAS BURNER FAILS TO IGNITE. CHECK GAS SUPPLY. 72 FALSE FLAME DETECTION. CALL SERVICE CENTRE. 12 LOSS OF COMBUSTION. CHECK GAS SUPPLY AND PRESSURE. 14 RESIDUAL FLAME SAFETY CALL SERVICE CENTRE. DEVICE. 32 THERMI

  • ETERNITY G16, ON `4 27n {I V II  A 1] ILTRAI7ER1 v ON 2ui A j ..w- ON/OFF USER INSTRUCTIONS PLEASE HAND THIS HANDBOOK TO THE USER AFTER INSTALLATION. INTRODUCTION: You have selected the ETERNITY electronic gas hot water unit. The following instructions will assist you to obtain the best performance from your ETERNITY unit. OPERATION: Up to three remote controls are able to be installed with your ETERNITY unit for complete controls of your hot water. Please note units without remote control will be set at 60°C or in the case of commercial units 75°C. OPERATION OF MAIN REMOTE CONTROLS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS APPLIANCE. 1. TURN ON THE ON/OFF S

  • ETERNITY G16, Eternity Continuous Flow 1. All Eternity water heaters must be installed by a Licensed installer. 2. Only Authorised personnel must Install, Commission or Service Eternity water heaters. 3. All Eternity water heaters must be installed in accordance with Manufacturer's Installation Instructions and in Accordance with local regulations, municipal building codes and current AS/NZS3000, AS/NZS3500, AS 3498 and AS5601. 4. If the Eternity water heater has not been installed in accordance with Manufacturer's Installation Instructions or installed as to be easily accessable for servicing, a service c

  • ETERNITY G16, INDEX INSTALLATION INSTRUCTIONS PAGE NO. Introduction 1 Dimensions Connections 2 Exploded Diagram 3 Technical Data 4-5 Gas Connection 6 Cold Water Connection 7 Hot Water Connection 8 Electrical Requirements 8 Remote Controls 9 Remote Controls Wiring Diagram 10 Main Remote Control 11 Shower Remote Control 12 Mounting Remote Controls 13-14 User Instructions 15-17 Care of THE ETERNITY Hot Water Unit 18 Hints for Using THE ETERNITY Unit 19-23 Fault Monitor 24 Warranty Conditions 25

  • ETERNITY G16, OPERATION OF SHOWER / SUB REMOTE CONTROLS The SHOWER/SUB CONTROLS overrides the operation of the main control. Leave the operation switch on the MAIN CONTROL switched ON. YST-84/84S SHOWER/SUB CONTROLS 1. Press the ON/OFF button after opening the cover on the CONTROLS. See diagram 1 below. 2. Press the TRANSFER BUTTON and the TRANSFER light will illuminate and the TEMPERATURE DISPLAY will have 42°C displayed. Please refer to page 12 of this handbook. See diagram 2 below. 3. Using the UP/DOWN BUTTONS select the temperature required. See diagram 3 below. 4.When you have finished using the hot water supply press the TRANSFER BUTTON to return the controls back to the MAIN CONTROL.

  • ETERNITY G16, ° 11_4_11 ON/Ofj ON v A J 'TRANSFER Check Caution CONFIRM IGNITION, COMBUSTION AND EXTINCTION Please always check ignition, combustion and extinction of the unit by the operation lamp of the main or shower/sub remote controls. DO NOT PUT WATER ON THE  DO NOT INSTALL NEAR ELECTRIC REMOTE CONTROLS  APPLIANCES (May cause failure.) Check Do not put water on the remote controls.  When installed near to TV or radio, it may cause It will cause failure.  picture disturbance or sound disturbance. Install away from those appliances. Instant overflow voltage caused by lightn ng can Make sure to se

  • ETERNITY G16, MAIN REMOTE CONTROL CMR-154 16 f ON (I) \ ( AL M AM  17 1' 1 • 17 17 t PMCILI•ULD rr j 4 - 1 Fi-1 U6FF i( 1 . :.:.. ... : o .....°: t.  .  .1 KITCHEN CMR- 154 ? TIME SET   I dlArrEtrnott mtealuttatettretcoarigit.*: hat. artdb.mst y t, onvittnet.tere,pkatekter 0.16 , 1111,t7 frvadcorfrratewta ts-o_ to el° 1 a 7 4 5 8 3 2 9 NOS. CONTROL FUNCTION 1 DIGITAL DISPLAY INDICATES TEMPERATURE & TIME ERROR CODE WHEN SAFETY DEVICE ON 2 TEMPERATURE CONTROL ADJUSTS TEMPERATURE BETWEEN 37°C TO 75°C 3 TRANSFER INDICATOR INDICATES THIS CONTROL HAS PRIORITY (GREEN) (CAN ADJUST TEMPERATURE

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Cisco 8851 Administration manual cisco/8851-R1H.pdf 27 Nov 2023 310
2 Denon AVR-3808CI Owner's manual denon/avr-3808ci-19L.pdf 08 Mar 2023 22 2.99 Mb
3 LG L177WSB Service manual lg/l177wsb-73N.pdf 06 Feb 2024 30
4 SPI Infrared Thermal Infrared Camera Operation & user’s manual spi-infrared/thermal-infrared-camera-YGF.pdf 15 Jan 2023 41 0.88 Mb
5 TEFAL FONDUE Manual  tefal/fondue-GAP.pdf 19 Sep 2023 8 0.19 Mb
6 Canon PowerShot SX110 IS Operation & user’s manual canon/powershot-sx110-is-4V6.pdf 02 Aug 2022 388 39.13 Mb

Similar Resources:

  • Trianco

    Greenflame 13kW

    (16 pages)
    Greenflame Wood Pellet Boiler 13-18kW 1 Greenflame Slim Wood Pellet Boiler 13-18kW Installation, Operation and Servicing Instructions Please read these instructions carefully before installing and operating this appliance TO BE RETAINED BY HOUSEHOLDER …
  • Sime

    ECOMFORT PLUS 25 HE

    (48 pages)
    ECOMFORT PLUS HE -EVInstallation and servicing instructionsUKENSURE THAT THESE INSTRUCTIONS ARE LEFTFOR THE USER AFTER COMPLETION OF THEBENCHMARK SECTIONPlease read the Important Notice withinthis guide regarding your boiler warranty199838 …
  • Bosch

    WORCESTER GREENSTAR DANESMOOR WALL MOUNTED...

    (20 pages)
    GREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25WALL MOUNTED OIL FIRED CONDENSING BOILERFOR FULLY PUMPED OPEN VENT OR SEALED CENTRAL HEATING SYSTEMS AND DOMESTIC HOT WATER CYLINDERSUSER INSTRUCTIONS &CUSTOMER CARE GUIDETHIS BOILER IS USED WITH KEROSENE (28 SECOND OIL) ONLY …
  • Alpha

    Evoke 28

    (64 pages)
    Installation and ServicingInstructionsEvoke 28 and 33Wall Mounted, Fan Assisted, Room Sealed,Gas Fired, High Efficiency Condensing Combination BoilerNepicar House, London Road,Wrotham Heath, Sevenoaks,Kent TN15 7RSFor Technical help or for Service call ...ALPHA HELPLINE Tel: 0344 871 8764website: www.alpha-innovation.co.ukSet for use with Natural GasLeave …
  • Baxi

    UBPU 25

    (12 pages)
    UBPU 25-500 UBPU PLUS 50-100-300 it MANUALE DI INSTALLAZIONE E MANUTENZIONE en INSTRUCTION FOR INSTALLATION AND MAINTENANCE de ANWEISUNGEN FÜR MONTAGE UND INSTANDSETZUNG fr MANUEL D'INSTALLATION ET D'ENTRETIEN …
  • Slant/Fin

    VICTORY VSPH SERIES

    (16 pages)
    CONTENTS PAGE Ratings and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .2Installation Requirements:Boiler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2–3Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..3Vent Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . …

Comments, Questions and Opinions: