Manualios.com

Eubank V SERIES Installation, Operation And Maintenance Manual

  • V SERIES Air Conditioner
  • maVfn0YdzHv3s
  • Installation, Operation And Maintenance Manual
  • PDF / Adobe Acrobat Reader
  • 16

Eubank V SERIES Manual Online:

4.75, 2204 votes
Eubank V SERIES User Manual
Eubank V SERIES User Guide
Eubank V SERIES Online Manual

Text of Eubank V SERIES User Guide:

  • Eubank V SERIES, Your equipment is covered by a LIMITED WARRANTY against defects in material and workmanship. This is a vertical, wallmount unit designed for many different applications in both residential and commercial settings. It is self- contained and arrives completely assembled, factory-charged and wired. The unit is 100% run-tested at the factory to ensure proper operation. Your unit is supplied with high-quality copper tubing and enhanced aluminum-finned coils for high heat transfer efficiency and long life. The unit cabinet is constructed of G-90 galvanized steel. All exterior surfaces are finished with a baked-on polyester coating. This will provide excellent corrosion pr

  • Eubank V SERIES, 3 TO CLEAN FRESH AIR INTAKE FILTER: A. Follow steps A and B at left “TO CHANGE SYSTEM FILTER”. B. Gently pull out the filter from the bottom. C. Wash the filter with water. D. Reinstall the filter, by sliding it into the retaining rail. E. Replace the access door and turn the power on to the unit. 2. Keep the outdoor coil clean. Wash it down with a garden hose if necessary. BE SURE THE UNIT DISCONNECT IS IN THE “OFF” POSITION AND THAT ALL ELECTRICAL POWER TO THE UNIT IS TURNED OFF BEFORE CLEANING THE SYSTEM. Remov

  • Eubank V SERIES, The installer MUST check available power to make certain it matches the unit nameplate rating and that constant voltage can be maintained to the unit. Unsatisfactory and unsafe performance could otherwise result. The local power company should be contacted about questions concerning power supply. These units are standard equipped from the factory with a unit disconnect. This is in the form of a circuit breaker (230V models) or a disconnect (460V models). If an optional electric heat kit is to be installed, follow the instructions included with the heater assembly. See Figure 1 for reference. The line voltage electrical servi

  • Eubank V SERIES, PART NUMBER DESCRIPTION V418B1 V424B1 V430B1 V430B3 V436B1 V436B3 V436B4 V448B1 V448B3 V448B4 V460B1 V460B3 V460B4 2 COMP-L18-001 H62J18BABCA 2 COMP-L24-001 H82J24BABCA 2 COMP-L30-001 H82J28BABCA 2 COMP-L36-001 H82J35BABCA 2 COMP-BZP16-001 ZP16K5EPFV130 X 2 COMP-BZP24-001 ZP24K5EPFV130 X 2 COMP-BZP28-001 ZP28K5EPFV130 X 2 COMP-BZP28-003 ZP28K5ETF5130 X 2 COMP-BZP34-001 ZP34K5EPFV130 X 2 COMP-BZP34-003 ZP34K5ETF5130 X 2 COMP-BZP34-004 ZP34K5ETFD130 X 2 COMP-BZP44-001 ZP44K5EPFV130 X 2 COMP-BZP44-003 ZP44K5ETF5130 X 2 COMP-BZP44-004 ZP44K5ETFD130 X 2 COMP-BZP

  • Eubank V SERIES, 8 28 2021-5010 TOP FRONT PANEL V18-24 X X 28 2022-5010 TOP FRONT PANEL V30-36 X X X X X 28 2023-5010 TOP FRONT PANEL V48-60 X X X X X X 29 2021-5011 MIDDLE FRONT PANEL (no fresh air) V18-24 X X 29 2021-5011E MIDDLE FRONT PANEL (economizer f/a) V18-24 X X 29 2021-5011F MIDDLE FRONT PANEL (barometric f/a) V18-24 X X 29 2022-5011 MIDDLE FRONT PANEL (no fresh air) V30-36 X X X X X 29 2022-5011E MIDDLE FRONT PANEL (economizer f/a) V30-36 X X X X X 29 2022-5011F MIDDLE FRONT PANEL (barometric f/a) V30-36 X X X X X 29 2023-5011 MIDDLE FRONT PANEL (no fresh air) V48-60 X X X X X X 29 2023-5011E MIDDLE FRONT PANEL (economizer f/a) V48-60 X X X X X X 29 2023-5011F MIDDLE FRO

  • 9 V Series Air Conditioners Electrical Data MODEL NO. & ELECTRIC HEATER kW [1] VOLT/PHASE NO. OF FIELD POWER CKTS. SINGLE-FIELD CIRCUIT DUAL-FIELD CIRCUIT MIN. CIRCUIT AMPACITY MAX. OVER CURRENT PROTECTION [2] FIELD POWER WIRE SIZE [3], [4], [5] GROUND WIRE SIZE MIN. CIRCUIT AMPACITY MAX. OVER CURRENT PROTECTION [2] FIELD POWER WIRE SIZE [3], [4] , [5] GRO

  • Eubank V SERIES, 1" K SERVICE DOOR FILTER ACCESS DOOR DISCONNECT OPENING J COMPRESSOR ACCESS DOOR FAN ACCESS PANEL A - FLANGE WIDTH B - UNIT WIDTH C L 30 1 /2" 1 7 /8" 7 3 /8" S I I SUPPLY AIR OPENING RETURN AIR OPENING T U V 5 /8" 2 1 /4" N M Q P R ALL MOUNTING HOLES Ø 3 /8" D E F G Y X W H J - FLANGE MOUNTING BRACKET 1 3 /8" 11 1 /4" 1 5 /8" 3 1 /2" 10 3 /4" 27 5 /8" 31 1 /2" FILTER GRILLE IS 1 /2" LARGER THAN “I” & “E” 11 1 /4" 11 1 /4" 11 1 /4" 11 1 /4" 11 1 /4" Z MODEL A B C D E F G H I J K L M N P Q R

  • Eubank V SERIES, 678629-V-B The information in this manual supersedes and replaces the previous instruction/operation manual 678629-V with regards to V Series wallmount products. Illustrations, part numbers and others cover the general appearance of the units at the time of publication and the manufacturer reserves the right to make changes in design and construction at any time without notice. For replacement parts contact: National Coil Company 1998 FM 2011 Longview, TX 75603 Phone: 903-643-2261 Fax: 903-643-2222

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Dell Latitude D630 XFR Quick reference manual dell/latitude-d630-xfr-V57.pdf 24 Jul 2023 23 0.99 Mb
2 Philips SPF4008/12 Quick start manual philips/spf4008-12-1K7.pdf 17 Jul 2022 12 3.04 Mb
3 Combi Rock N Roll Walker Instruction manual combi/rock-n-roll-walker-KTT.pdf 26 Jul 2023 8 1.42 Mb
4 Philips Beard Trimmer QT4020/10 Brochure & specs philips/beard-trimmer-qt4020-10-91H.pdf 17 Jan 2023 2 0.44 Mb
5 Archos PMA 400 Operation & user’s manual archos/pma-400-749.pdf 14 Sep 2022 192 21.75 Mb
6 Whirlpool LBR5133AG0 Use & care manual whirlpool/lbr5133ag0-831.pdf 26 Jun 2022 24 1.39 Mb

Similar Resources:

  • Haier

    HBU-18CF03

    (25 pages)
    Please read this operation manual before using the air conditioner.No.0010576826AIndoor Unit Operation & InstallationManualCASSETTE TYPE AIR CONDITIONERPlease keep this manual carefully and safely.HBU-18HF03HBU-18CF03 …
  • Samsung

    AM FN1DEH Series

    (40 pages)
    Air Conditionerinstallation manualimagine the possibilitiesThank you for purchasing this Samsung product.Cassette Type Series1 Way cassette : AMFN1DEH AMHN1DEH AMJN1DEH2 Way cassette : AMFN2DEH4 Way cassette : AMFN4DEH AMKN4FEHDB68-03565A-09ENDVM S CASSETTE_IM_03565A-09_EN.indd 1 201 …
  • Gibson

    GAH126R2T - GIBSON 12000BTU 230V 6.0A 9.0E3 SPD 4 WAY AIR DIRECTION

    (4 pages)
    FAH14EQ2T.eps FAH086R1T Parts.eps 63611091.eps Product No. GAH126R2T1 Series TTW/Builder Color white Volts 230/208 BTU-Cooling 12000/11700 Owner's Guide 66121669en Installation Instructions 66121627 Market North America Electrolux Major Appliances North & Latin America P.O. BOX 212378 AUGUSTA, GA 30917 Publication No. 599 …
  • KONVEKTA

    KL40T

    (16 pages)
    Konvekta AGKonvekta AGKonvekta AGKonvekta AG Am Nordbahnhof 5 34613 Schwalmstadt Germany  +49 ( 0 ) 66 91 / 76 – 0  +49 ( 0 ) 66 91 / 76 – 200  [email protected] www.konvekta.com Operating InstruOperating InstruOperating InstruOperating Instrucccctiontiontiontion for for for for KONVEKTA KONVEKTA KONVEKTA KONVEKTA Air Condition …
  • Daikin

    FTXL20G2V1B

    (35 pages)
    DAIKIN ROOM AIR CONDITIONEROPERATION MANUALEnglishDanskSvenskaNorskSuomiDeutschFrançaisPolskiNederlandsFTXL20G2V1BFTXL25G2V1BFTXL35G2V1BMODELS00_CV_3P232537-1.fm Page 1 Monday, June 30, 2008 1:17 PM …
  • Bryant

    Air Conditioning System

    (6 pages)
    Owner’s Information M anualAir Conditioning SystemNOTE TO EQUIPMENT OWNER:For your convenience, please record the model and serial numbers of your new equipment in the spaceprovided. This information, along w ith the installation data and dealer contact information will be helpfushould your system require maintenance or service.OUTDOOR UNIT (Air Conditione …

Comments, Questions and Opinions: