  • 1144 02 Smoke Alarm
  • maH1raOWhfDgk
  • Installation And Operating Instructions Manual
  • PDF / Adobe Acrobat Reader
  • 16

Gira 1144 02 Manual Online:

3.05, 1337 votes
Gira 1144 02 User Manual
Gira 1144 02 User Guide
Gira 1144 02 Online Manual

Text of Gira 1144 02 User Guide:

  • Gira 1144 02, 2 Table of contents Product features..........................................................................................3 Functional principle.....................................................................................3 Safety instructions ......................................................................................4 Correct behaviour in case of fire..................................................................5 Mounting site..............................................................................................6 Unsuitable mounting sites...........................................................................9 Installation and commissioning ..............

  • 3 Product features • Battery-operated smoke detector with photoelectric scattered-light principle • Automatic self-test of the smoke development • Loud pulsing alarm sound approx. 85 dB(A) • Battery replacment display (1) • Soiling/Fault display (1) • Test button for function test (2) • Battery compartment check: If no battery is inserted in the smoke d

  • Gira 1144 02, 4 Safety instructions • Do not paint over the smoke detector. • Smoke detectors only recognise the smoke of a fire, not the flame itself. • Smoke detectors do not extinguish a fire. In case of an alarm search for the source of the fire and, if necessary call the fire brigade (also refer to "Correct behaviour in case of fire" on Page 5). • Do not use rechargeable batteries (accumulators) or power supply units as the voltage supply source. They can cause malfunctions or a premature failure of the device. • The smoke detector generates a very loud and shrill sound which can damage y

  • Gira 1144 02, 5 Correct behaviour in case of fire Giving an alarm Notify the fire brigade immediately. Remain calm and answer the questions you are asked clearly: Where is it burning? What is burning? How many persons are injured? Who is calling? Be ready to respond to any further questions of the fire brigade. Rescuing Rescue yourself and endangered persons from the danger area. In case of strong smoke formation keep close to the floor and press a moist cloth against your mouth and nose. Do not use any lifts. Close the doors and windows of burning rooms in order to prevent the fire and smoke from spreading. If it is not possible to flee out of the building, find a safe room,

  • Gira 1144 02, 6 Mounting site Example of a home Minimum protection, one smoke detector in the corridor or stairwell of each floor Optimum protection, one smoke detector in each bed- and living room Preferably install the smoke detectors before or in the bedrooms so that the occupants are woken by the smoke alarm during the night. Mount the smoke detector in the middle of the room under the ceiling to achieve optimum detection characteristics. If this is not possible, observe a minimum distance of 50 cm to the wall. A smoke detector can monitor a room with a maximum of 60 m² area

  • Gira 1144 02, 7 Example of a residential building Minimum protection, one smoke detector in the corridor or stairwell of each floor Optimum protection, one smoke detector in each bed- and living room or cellar room In buildings with several storeys mount at least one smoke detector in each storey corridor. i Recommendation Use several interconnected smoke detectors in larger houses in order to cover the entire living area.

  • Gira 1144 02, 8 Example for particular room geometries In L-shaped rooms or corridors the smoke detectors should be installed on the centred intersections of the two sections. In the case of large L-shaped rooms, each section is regarded as a separate room.

  • 9 Unsuitable mounting sites In order to avoid false alarms, do not mount the smoke detector: • In rooms in which strong water vapour, dust or smoke arise under normal conditions. • Near fireplaces and open fires. • Near ventilation shafts because the air stream may prevent the smoke from approaching the detector. • Near fluorescent and energy-saving

  • Gira 1144 02, 10 Installation and commissioning 1. Mount the base with the enclosed mounting material. 2. Connect the 9 V block battery to the battery connection and insert the battery into the battery compartment. 3. Insert the smoke detector into the base and latch it in by turning it slightly clockwise. 4. Carry out a function test (see Page 12). Legend 1 Dowel 2 Base 3 Screws 4 Battery (9 V) 5Smoke detector i Insert battery The smoke detector cannot be latched into the base without a battery. 1 2 3

  • 11 Battery check - Changing the battery The smoke detector is supplied with voltage by a 9 V block battery. The battery test automatically checks the supply voltage in regular intervals. If the battery voltage drops below a defined point, the smoke detector signals for 30 days that the battery has to be replaced. The smoke detector is completely functional during this period. Proceed as foll

  • Gira 1144 02, 12 Function test Carry out the function test once a month: 1. Press the test button for approx. 3-sec. If the signal sound is emitted, the smoke detector operated correctly. If no signal sound is emitted, replace the battery. 2. Carry out the function test again. If no signal sound is emitted again, the smoke detector is defective and has to be replaced with a new one. Operating and alarm signals Caution: Hearing damage possible The smoke detector generates a very loud and shrill sound which can damage your hearing. Therefore stay at

  • Gira 1144 02, 13 Maintenance and care In order to ensure the functional reliability of the smoke detector for a longer period, you should carry out maintenance once a month (or when a fault message occurs): 1. Remove the smoke detector from the base (turn counter-clockwise) and remove the dust. 2. Wipe the smoke detector with a moist cloth. 3. Insert the smoke detector back into the base and turn it clockwise until it latches in. 4. Check whether the automatic self-test is carried out (smoke detector flashes every 45 seconds. 5. Carry out a function test. i Insert battery The smoke detector cannot be latched into the base without an inserted battery. i Replaci

  • Gira 1144 02, 14 Technical data Nominal voltage: 9 VDC Battery: Block battery, IEC 6 LR 61, 9 V Battery durability: At least 1 year Battery failure signal: 45-sec. cycle, 30 days Optical indication: LED, red Acoustic alarm indication: Piezo primary detector: Intermittent Volume: Approx. 85 dB(A) at 3m Housing dimensions: 110 x 40 mm (Ø x H) Operating temperature: +4 °C to +40 °C Weight (without battery): Approx. 120 g VdS approval: Refer to identification label on smoke detector

  • Gira 1144 02, 15 Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault. Gira Giersiepen GmbH & Co. KG Service Center Dahlienstraße 12 D-42477 Radevormwald Germany The CE sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties.

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Philips DVP3020K/03 Operation & user’s manual philips/dvp3020k-03-8HL.pdf 20 Jul 2022 40 1.47 Mb
2 Billy Goat F601S Owner's manual billy-goat/f601s-437.pdf 20 Feb 2023 10 1.07 Mb
3 Tiger ED 9-009-03 Instruction manual tiger/ed-9-009-03-R6J.pdf 07 Aug 2023 12 6.41 Mb
4 Airvitamin EUG-A1000 Operational manual airvitamin/eug-a1000-U3T.pdf 28 Oct 2022 8
5 ACTi ACM-4200 Hardware user manual acti/acm-4200-491.pdf 09 Apr 2023 13 0.2 Mb
6 Blodgett RE Series Installation & operation manual blodgett/re-series-QVA.pdf 02 Dec 2023 58 0.63 Mb

Similar Resources:

  • Bosch

    FERION 4000 O

    (100 pages)
    Smoke AlarmFERION 4000 OUser Guidear da danskde deutschel ελληνικάen englishes españolfi suomifr françaisit italianonl dutchnn norskpt portuguesesv svensktr türkçe …
  • LST

    M210E

    (2 pages)
    © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVEDM210E_DBL_LST_EN_0804.PDF • PAGE 1ABuilding Safety. Building Security.Monitor ModuleM210EDescriptionThe addressable Monitor Module M210E serves for the line-monitored integration of …
  • First Alert

    SLED177

    (2 pages)
    1 2 3 4 5 6RECOMMENDED PLACEMENT FOR HEARING IMPAIRED STROBE LIGHTAccording to NFPA 72, at a minimum a strobe should be installed within 16 feet (4.9 meters) of the pillow. For wall mounting: The strobe should be between 80 to 96 inches (203 to 244 cm) above the floor. For ceiling mounting: Ideally the strobe should be located near the center of the room. Se …
  • Klaxon

    Nexus AC Sounder & Sounder-Beacon

    (2 pages)
    Low Voltage AC Sounder & Sounder-BeaconInstallation InstructionsKlaxon Signals Ltd, Oldham, OL4 1HW, UKPhone +44 161 287 5555 Fax +44 161 287 5511E-mail [email protected] 5 (July 2008) 18-186508Copyright © Klaxon Signals Ltdwww.klaxonsignals.comTone Tone Type Tone Description / Application Dip Switch 3rd Stage Peak Sound(S1/S2) Tone Level (dB …
  • Honeywell

    HI-SPEC

    (12 pages)
    HI-SPEC unit_HON.doc 07/2011 1 of 12 Installation Instructions Honeywell Air Sampling Smoke Detection System Honeywell HI-SPEC 1411114 3162571089121311 1 Operating-indicator light 2 Indicator light for fault 3 Indicator light for alert alarm-detector module I 4 Indicator light for action alarm-detector module I 5 Indicator light for fire …
  • Omega Engineering

    Four Zone Temperature OMA-VM520

    (12 pages)
    M4548-0607 omega.com e-mail: [email protected] latest product manuals:omegamanual.infoUser’s GuideMADE INShop online atManual and Installation Instructions Four Zone Temperature Monitor and Alarm Models: OMA-VM520 OMA-VM520-DCP …

Comments, Questions and Opinions: