Manualios.com

Ayre T27-M11 Service Manual

Ayre T27-M11 Manual Online:

3.45, 2079 votes
Ayre T27-M11 User Manual
Ayre T27-M11 User Guide
Ayre T27-M11 Online Manual

Text of Ayre T27-M11 User Guide:

  • Ayre T27-M11, www.ayre.com.au T-series Split System Air Conditioner SERVICE MANUAL • T27-M11 2.7kWSplitSystem • T33-M11 3.2kWSplitSystem • T50-M11 5.0kWSplitSystem • T70-M11 7.0kWSplitSystem

  • Ayre T27-M11, Contents 1. Important notice ...............................................................2 2. Technical specications ..................................................3 3. Operation details ...............................................................4 4. Wiring diagrams ..............................................................12 5. Explosion views – indoor unit ....................................14 6. Explosion views – outdoor unit .................................18 Service Manual • T-se

  • Important notice This service manual is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair the appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liabil

  • Ayre T27-M11, T27-M11 T33-M11 T50-M11 T70-M11 Model No. Technical specications Control type 0007000,5002,3056,2Wyticapac gnilooc detaR 0007000,5002,3056,2Wyticapac gnitaeh detaR 352.3303.3776.3466.3W/WTested AEER for cooling 0.21.25.25.2gnilooc rof rats ygrenE Tested ACOP for heating W/W 3.944 3.736 3.269 3.334 0.20.205.20.3gnitaeh rof rats ygrenE 8.12.18.08.0h/sretiLlavomer erutsioM 25842424)A(BdhgiH 05640483)A(Bd.deM 64348363)A(BdwoL 16068555)A(Bdlevel rewop dnuos roodtuO Electrical Data Power supply VegnaR egatloV 5.90.79.34.3AgnilooC 2.98.68.31.3AgnitaeH 0022065,1098067WgnilooC 0012005,1068007WgnitaeH 6

  • Ayre T27-M11, 4 Note: Each mode and relevant function will be further specified in following pages. SLEEP FAN TIMER SWING ON/OFF MODE MID SWING AUTO DRY FAN HEAT COOL FEEL SLEEP TIMER ON HIGH LOW TMIER OFF The remote controller transmits signals to the system. Remote controller 1 2 4 3 5 6 7 8 8 4 MODE button FAN SPEED control button UP button (TOO COOL button) DOWN button (TOO WARM button) ON/OFF button SLEEP button VANE control button TIMER button Used to select the type of operation mode: Feel, Cooling, Dry, Fan and Heating(Only for Heat Pump). Used to select the indoor

  • 5 Electronic controller: 1.Automatic mode 1) Initial RT determines the working mode and ST,the mode is determined effective only once unless A/C shut-down then re-started. If from other modes switches to autoamatic mode (including mode conversion after shutdown), it should be that the compress stop more than 3 min then temperature judgement and automatic mode are conducted (it can conduct

  • 6 When the temperature changes lead to changes in airflow speed, the switch can only be made orderly, and every grade of air flow speed runs 1 minute at least. 3, Dry mode running into this mode, the Air cond. firstly operates for 3 minutes according to cooling mode (set temperature is 16℃ or 18℃) , and then takes the detected backflow air temperature m

  • Ayre T27-M11, 7 Except the above signal processing during defrosting, no other signals will be dealt with, but only a loud buzz. During defrosting, electrical heating stops compulsively. Defrosting enter and exit pragram: Option 1:with jumper JC The condition of enter defrosting: run into defrosting once any of condition 1, 2, and 3 met. Condition 1:As shown in figure 3 Defination: The followings are all required to meet: a. IPT1 settles for IPT1=IPTmax-△IPT(8℃) b. t5≥50min(running time t5≥50min(the compressor runs cumulatively),t5 is r

  • Ayre T27-M11, 8 when the compressor runs for 45 min, if the indoor coil temperature is less than 40 ° C for 2 min, the machine runs into defrosting, and lasts for 3min, otherwise when the compressor runs for 120 min, the machine runs into defrosting automatically and last for 10 min. Option 3: No jumper JC, but with OPT outdoor sensor When heating, when the temperature of outdoor unit under heat-exchange is lower than E ° C (-4 ° C), and the compressor runs for 45 min, then the machine runs into defrosting and last for 10 min. Option 4. When heati

  • Ayre T27-M11, 9 g. IPT≤43°C; (3) The conditions of stopping auxiliary electric heating(any one of the following conditions met, the state stops) a. the compressor stops b. RT≥24°C; c. IPT≥48°C d. indoor fan stops。 e. running into sleeping function 5. Fan mode 1) Indoor fan motor control: indoor fan motor is running at setting speed (the speed is same as that of heating). 2) Vane motor control: running according to the setting. 3) The outdoor unit is not working under fan mode. 6. Sleeping mode 1) Under sleep mode, the indoor fan motor is running at a low-airflow speed,except that the power light and sleep light are on, timer

  • Ayre T27-M11, 10 protection in cooling, Overheating protection in heating and sensor fault protection and defrost operate are effective. 5) Under emergency operation, once effective signal from remote controller is received, then the machine exits form the emergency mode, and operate according to the setting from remote controller. 9. Auto-restart function 1) The PCB retains the setting parameters in case of power off. When the power supply is resumed, the machine, which has been started up the power-off memory function, is able to restore

  • Ayre T27-M11, 11 Figure 5 Anti-cold Wind 2) The following table shows the fault protections. When failures happens, the PCB alarms and buzzer rings three times. Failure code appears, and the PCB operates protection procedures. Failure code: For the machine has LED, the code displays on LED, for no LED machine, the code reflects by the running light. Failure Running Light Flash LED Display RT Sensor Failure Once / Period E1 IPT Sensor Failure Twice / Period E2 Indoor Fan Motor Failure 6 times / Period E6 When there is LED displaying failure code, the code is dis

  • Ayre T27-M11, 13 WIRING DIAGRAM MODEL: T70-M11 INDOOR UNIT: OUTDOOR UNIT Compressor White(Black) CM C R(M) S Blue Red Compressor Capacitor Fan Yellow YLW/GRN Optional Part Fan Motor FM Protector White Brown Contactor Power Supply Outdoor Unit Indoor Unit Red Blue Blue Blue Yellow Capacitor YLW/GRN YLW/GRN White Red Blue Blue Blue Brown Blue Red White Vane 1 2 3 N L O.P.T L N L N 3 2 1 Service Manual • T-series Split System Air Conditioner

  • Ayre T27-M11, No. Part No. Part Name Q’ty Remark 1 Installation Plate 1 2 Base 1 3 Cross Fan 1 4 Bearing Mount 1 5 Evaporator 1 6 Water Drainage Assembly 1 7 Vertical Vane Assembly 2 8 Face Frame 1 9 Screw Cover 2 10 Air Filter 2 11 Front Panel 1 12 Power Supply Cord 1 13 Vane 1 14 Drainage Hose 1 15 Display PCB Cover 1 16 Display PCB(Digital) 1 17 Display PCB Box 1 18 Cable Clamp 1 19 Main PCB(Digital) 1 20 Electrical Box 1 21 Vane Motor 1 22 Sensor Holder 1 23 Indoor Motor 1 24 Indoor Motor Cover 1 25 Transformer 1 26 Indoor Sensor Assembly 1 27 In And Out Pipe Fixer 1 28 Remote Controller 1 29 Remote Controller Supporter 1 30 Indoor C

  • Ayre T27-M11, Part List No. Part No. Part Name Q’ty Remark 1 Installation Plate 1 2 Base 1 3 Cross Fan 1 4 Bearing Mount 1 5 Evaporator 1 6 Water Drainage Assembly 1 Vertical Vane Assembly A 1 Vertical Vane Assembly B 1 8 Face Frame 1 9 Screw Cover 3 Left Air Filter 1 Right Air Filter 1 11 Front Panel 1 12 Display PCB Cover 1 13 Display PCB (digital) 1 14 Vane A 1 15 Vane B 1 16 Drainage Hose 1 17 Cable Clamp 1 18 Vane Motor 2 19 Sensor Holder 1 20 Main PCB(digital) 1 21 Indoor Motor Cover 1 22 Indoor Motor 1 23 Electrical Box 1 24 Transformer 1 25 Indoor Sens

  • Ayre T27-M11, 18 EXPLOSION VIEW Model: T27-M11, T33-M11, T50-M11 OUTDOOR UNIT: 10 11 12 8 9 7 6 5 17 13 14 16 15 19 18 20 21 23 22 24 4 3 2 25 26 27 1 Service Manual • T-series Split System Air Conditioner

  • Part List No. Part No. Part Name Q’ty Remark 1 Grille 1 Optional 2 Top Cover 1 3 Condenser 1 4 Outdoor Motor Supporter 1 5 Outdoor Motor 1 6 Propeller Fan 1 7 Left Grille Supporter 1 8 Front Plate 1 9 Fan Guard 1 10 Compressor And It Accessories 1 11 4-way Valve 1 12 4-way Valve Assembly 1 13 Base 1 14 Right Plate 1 15 Two-way Valve 1 16 Valve Supporter 1 17 Th

  • Ayre T27-M11, No. Part No. Part Name Q’ty Remark 1 Grille 1 Optional 2 Top Cover 1 3 Condenser 1 4 Outdoor Motor Supporter 1 5 Outdoor Motor 1 6 Propeller Fan 1 7 Left Grille Supporter 1 8 Front Plate 1 9 Fan Guad 1 10 Compressor And It Accessories 1 11 4-way Valve 1 12 4-way Valve Assembly 1 13 Base 1 14 Right Plate 1 15 Two-way Valve 1 16 Valve Supporter 1 17 Three-way Valve 1 18 Electrical Box Cover 1 19 Cable Clamp 1 20 Terminal 1 21 Fan Motor Capacitor 1 22 Compressor Capacitor 1 23 Capacitor Strip 1 24 Electrical Parts Box 1 25 AC Contactor 1 26 Capillary Assembly 1 27 Partition plate 1 28 Outdoor Senso

More Instructions:

DOWNLOAD

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Canon LASER CLASS 7000 Instruction manual canon/laser-class-7000-4LJ.pdf 02 Feb 2024 56 2.87 Mb
2 Grundig MCD 50 Service manual grundig/mcd-50-O6W.pdf 03 Dec 2023 16
3 Philips SPD6000FO Specifications philips/spd6000fo-2L1.pdf 23 Mar 2023 2 0.3 Mb
4 Morgana Documaster MK3 Operator's manual morgana/documaster-mk3-S66.pdf 12 Oct 2023 55
5 Anest Iwata WS-400 EVO Instruction manual anest-iwata/ws-400-evo-258.pdf 17 Sep 2023 24
6 Zte MF636 Operation & user’s manual zte/mf636-4D5.pdf 30 Jul 2022 14

Similar Resources:

  • Close Comfort

    COOL FOCUS

    (5 pages)
    SAFETYAvoid using this product in a wet environment. Avoid prolonged exposure to direct sunlight. Ensure that anyone using this product is aware of normal safety precautions for household electric appliances.PARTSUser GuideIntroductory Quick Start GuideCOOL FOCUS personal Air ConditionerEASY FOCUS personal Air ConditionerFocus Enhancer2 …
  • Nordyne

    NS6QD SERIES

    (20 pages)
    Please read this information thoroughly and become familiar with the capabilities and use of your appliance before attempting to operate or maintain this unit. Keep this literature where you have easy access to it in the future. If a problem occurs, check the instructions and follow recommendations given. If these suggestions don’t eliminate your problem, …
  • Samsung

    SCH U520 - Cell Phone - ALLTEL Wireless

    (196 pages)
    AC01.06_CB_u520_040907_F6SCH-u520 SeriesPORTABLE DUAL-MODEMOBILE PHONEUser GuidePlease read this manual before operating yourphone, and keep it for future reference. …
  • Technibel

    CA250X5TAA

    (58 pages)
    TECHNICAL & SERVICE MANUALSPLIT SYSTEM AIR CONDITIONERCA250X5TAA - GR250X5TAA CA250X5TAA - GR250X7TAA CA360X5TAA - GR360X7TAA CA480X5TAA - GR480X7TAA0.8180.112.1 05/01 …
  • Sanyo

    SAP-CMRV1426EH

    (148 pages)
    TECHNICAL & SERVICE MANUALOUTDOOR UNIT : SAP-CMRV1426EHSAP-CMRV1926EHSAP-CMRV1936EHSAP-CMRV2446EHSAP-CMRV3146EHSAP-CMRV1426EHSAP-CMRV3146EHSAP-CMRV1926EHSAP-CMRV1936EHSAP-CMRV2446EHDC INVERTER MULTI-SYSTEM AIR CONDITIONEROutdoor Model No.SAP-CMRV1426EH-FSAP-CMRV1926EH-FSAP-CMRV1936EH-FSAP-CMRV2446EH-FSAP-CMRV3146EH-FCapacity4.0kW5.6kW5.6kW6.8kW8.0kWProdu …
  • Panasonic

    CS-HZ25UKE

    (75 pages)
    © Panasonic Corporation 2018 Order No: PAPAMY1807098CE Indoor Unit Outdoor UnitCS-HZ25UKE CS-HZ35UKE CS-HZ25UKE-5 CU-HZ25UKECU-HZ35UKECU-HZ25UKE-5DestinationNorth Europe WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to …

Comments, Questions and Opinions: