  • Configuration 38 1. FA-300 CONFIG (Command-Menu) The following is a detailed description of the FA-300 configuration menu. Command Menu/FA-300 Config-->Features 1. Features 2. Inp Zone 3. I3 Zone 4. Opt. Zone -FA-300 Config- 5. Correlation 6. Inp Zone Label 7. Opt Zone Label 8. Default Config 1 Man. Sig. Sil. 2 Fire Drill 16 Active EOL - Feature Config - 3 Opt. Ckt.

  • Mircom FA-300 Series, Mechanical Installation 10 Figure 2A: FA-300-6DDR/6DR Box dimensions, mounting and trim ring 17" 22.5" Adhere trim ring to wall surface around the FA-300 backbox. PLACE FA-300TRB TRIM RING OVER BACKBOX 14.5" 4 . 5 " 11" 20.0" 1.5" 5.425" 14.5" 3.5" 1" 3.5" is the maximum depth for semi-flush mounting using the flush trim ring 1" is the minimum depth above the wall required for semi-flush mounting using the flush trim ring 4 Mounting Holes for Surface Mounting

  • FA-300 Series LCD Version Installation and Operation Manual 13 DIP Switch and Jumper Selections for Main Board and Adder Modules Main Fire Alarm Board Figure 5: Main Fire Alarm Board DIP switch and jumper settings for FA-301 LCD Panels S-+NC NOCNC NOCNC NOCNC NOC +-+- COM(+) CO M (-) TRLTRB RTRT RTRT RES CO RES CO LINE1LINE2 JW3 JW2 JW1 -+-+-+-+-+-+-+-+-+-+-+-+-+

  • Mircom FA-300 Series, Configuration 52 9. Dialer Config (Command-Menu) The following illustration shows the dialer configuration menu. Each item in this menu is described below in detail. Command Menu-->Dialer Config Account Info Note: Refer to How to Use the Keypad to Program the FA-300 on page 39 for detailed instructions on making menu selections. Command Menu/Dialer Config/Account Info 1.Account# 1 Identification 123456->Default Use this function to set the Account ID for the monitoring station to which the dialer reports events. The maximum # of digits allowed is six

  • Mircom FA-300 Series, FA-300 Series LCD Version Installation and Operation Manual 65 Appendix A: Compatible Receivers The dialers that are built into select models of the FA-300 Series Fire Alarm Control Panels are compatible with the following Digital Alarm Communicator Receivers (DACR): DACR Receiver Model Protocols SurGard MLR2 Multi-Line Receiver (ULC, ULI approved) SIA-DCS and Ademco Contact ID SurGard SLR Single-Line Receiver (ULC, ULI approved) SIA-DCS and Ademco Contact ID Osborne-Hoffman Quickalert! II Receiver (ULI approved)

  • Mircom FA-300 Series, FA-300 Series LCD Version Installation and Operation Manual 23 Relay Adder Module Wiring Wire relays on the relay adder modules RM-312 and RM-306 as shown in Figures 17 and 18. Figure 19: Relay per zone (RM-312) Terminal connection Figure 20: Relay per zone (RM-306) Terminal connection C C NO/NC NO/NC C NO/NC ALL RELAY CONTACTS 28V DC, 1 AMP RESISTIVE LOAD RM-312 12 RELAY ADDER MODULE NORMALLY OPEN OR NORMALLY CLOSED CONNECTION IS SELECTED BY JUMPER ON RELAY BOARD. NOTE: ALL RELAY CIRCUITS ARE POWER LIMITED AND MUST USE TYPE FPL, FPLR or FPLP POWER LIMITED CABL

  • Mircom FA-300 Series, FA-300 Series LCD Version Installation and Operation Manual 59 11. Bypass Det Ckt (Command-Menu) 12. Bypass NAC Ckt (Command-Menu) 13. Aux. Disconnect (Command-Menu) Note: Refer to How to Use the Keypad to Program the FA-300 on page 39 for detailed instructions on making menu selections. Initiating zones may be bypassed individually. This bypass command will allow you to scroll through all initiating zones 1 to a maximum of 12 depending on the size of the panel. Press Enter to bypass the zone or scroll up or down to un-bypassed (normal connected circuit). Press Enter to un-bypass the zone or scroll up or down to bypass (off no

  • Mircom FA-300 Series, FA-300 Series LCD Version Installation and Operation Manual i Contents Industry Canada and FCC Notice ........................................................................................... 1 Introduction .............................................................................................................................. 2 Overall Features ................................................................................................................... 2 Conventions ............................................................................................................................. 3 Circuits..............

  • Mircom FA-300 Series, FA-300 Series LCD Version Installation and Operation Manual 45 Command Menu-->FA-300 Config Opt Zone Label Use the keys in described below for entering a message. These letter keys are alternate functions of the numbered keys are physically located in the same position as described below. Command Menu-->FA-300 Config Default Configuration Note: Refer to How to Use the Keypad to Program the FA-300 on page 39 for detailed instructions on making menu selections. Command Menu/FA-300 Config/Opt. Zone Label 1.Indicating zone label 4. [NAC-1 ]->Default [NAC-4 ]->Default KEYPAD TRANSLATION AS MARKED ON THE KEYS Sequence refers to the number of times the key

  • Mircom FA-300 Series, Mechanical Installation 12 Figure 4: Installation of Adder Modules for FA-300 LCD Panels BATTERY BATTERY CLASS-A converter board for detection circuits ICAC-306 (6 circuits ) CLASS-A converter board for indicating circuits OCAC-302 (2 circuits ) Reverse polarity and city tie module PR-300. Mounted on hex spacer with two screws provided Relay Module RM-306 Mount relay module on the left side using two screws provided . LCD configuration tool - CFG-300 plugged into the socket shown. Transformer Fuse and AC wirung terminal MAIN FIRE PANEL BOARD S-+NC N OCNC NOCNC NOCNC NOC COM(+ ) COM(-) TRLTRB RTRT RT R T RES CO RES C O LINE1LI

  • Mircom FA-300 Series, Configuration 36 Configuration There are three methods of configuring the FA-300 LCD Series Fire Alarm Panels: Direct configuration using the main LCD display and the menu buttons. Using a PC or Lap Top Computer with a UIMA converter module. Using a PC or laptop computer with remote connection (must use fire alarm with built-in UDACT). The following information for configuring an FA-300 LCD Series Fire Alarm Panel is based on using the front panel main LCD display for configuration. To access configuration mode press the Menu button on the front panel display. The LCD will display the Main Menu. The function of different buttons on the front panel display is sh

  • Mircom FA-300 Series, System Components 4 System Components Main Fire Control Panel Model Description FA-301-12DDR Twelve-Zone Fire Alarm Control Panel with LCD display and dialer (red door, black box). 12 Class B (Style B) Initiating circuits, and four Power Limited Class B (Style Y) Indicating circuits (up to 1.70 amperes each, 5 amperes total). Two six zone ICAC-306 Input Class A Converter adder modules may be used for Class A (Style D) wiring of Initiating circuits. One OCAC-304 Output Class A Converter adder module may be used for Class A (Style Z) wiring of the Indicating circuits. The FA- 301-12DDR contains Common Alarm,

  • Mircom FA-300 Series, FA-300 Series LCD Version Installation and Operation Manual 21 Figure 16: Indicating circuit – Class A or Style Z wiring Four Wire Smoke Detector Wiring Figure 17: Four-wire smoke detector wiring BELL STROBE HORN + - STYLE Y WIRING STYLE Y WIRING INDICATING CIRCUIT #1 INDICATING CIRCUIT #2 INDICATING CIRCUIT 1 INDICATING CIRCUIT 2 2 MORE INDICATING CIRCUITS NOT SHOWN OCAC-304 CLASS A CONVERTER MODULE FIRE ALARM MAIN BOARD BLK RED BLK RED - SIG1 OU T+- SIG2 OUT+ - SIG1 RET+- SIG2 RET+ + - SIG 1SIG 2 POWER DETECTION ++ ++ -- -- 1 4 2 3 5 6 TO I

  • Appendix C: Specifications 68 Appendix C: Specifications FA-300 Fire Alarm Control Panel (LCD) RM-312/306 Relay adder module Digital Signal Processor (DSP) based design. Fully configurable using front panel LCD display with Password Access. Electrical Ratings AC line voltage 120 VAC 60 Hz 3 amps\ 240 VAC 50 Hz 1.5A (primary) Power Supply Rating 6 amps maximum (secondary) Battery Type: 24VDC Gel

  • Warranty & Warning Information 70 Warranty & Warning Information Warning Please Read Carefully Note to End Users: This equipment is subject to terms and conditions of sale as follows: Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of th

  • Mircom FA-300 Series, Configuration 50 7. Walk Test (Command-Menu) Walk-Test allows an installer to verify the initiating circuit wiring in a system. When walk test is selected, the following screen confirms the operation: Press the “ENTER” key to activate the walk test and the “CANCEL” key to cancel the walk test. The next screen will allow zones to be selected for walk test. Use the “UP” and “DOWN” keys to scroll through the zones and use the “LEFT” or ‘RIGHT” keys to select a zone. Press the “ENTER�

  • Mircom FA-300 Series, Configuration 46 2. Config Info (Command-Menu) Note: Refer to How to Use the Keypad to Program the FA-300 on page 39 for detailed instructions on making menu selections. Press down arrow key to see more information. Configuration type will show how the panel was configured. “Factory default” means the panel has not been configured, it is as it came from the factory. “Front Panel” means it was configured at the panel. “Serial Port” means the configuration was done from a computer through the serial port. “Modem” means the con

  • Mircom FA-300 Series, FA-300 Series LCD Version Installation and Operation Manual 3 Conventions Circuits Refers to an actual electrical interface for Initiating (Detection) and Indicating (Signal) or Relays Zone Is a logical concept for a Fire Alarm Protected Area, and will consist of at least one Circuit. Often the terms Zone and Circuit are used interchangeably, but in this Manual the term Circuit is used. Events There are events associated with every initiating, indicating and common circuit of the fire panel displayed via the LCD. W

  • Mircom FA-300 Series, Configuration 64 If there is an open detected on the city tie output, the following trouble message is displayed: Note: The trouble code and info is for trained service personnel only. "INFO" Key City Tie trouble Active 1/ 1 Trouble Type EVENT 01 of 01 Trb:0x03 Info:0x0001 00:07 SAT 2000-01-01 DATE TIME Trouble code Trouble Info

  • FA-300 Series LCD Version Installation and Operation Manual 11 Installing the Adder Modules FA-300 Series Fire Alarm panels come pre-assembled with all components and boards except for Adder Modules. Module installation locations are shown below. Refer to Figure 4 for Jumper or DIP Switch settings and see Wiring Tables and Information section for wiring information. Figure 3: Installation of

  • Mircom FA-300 Series, Field wiring 20 Figure 14: Initiating circuit– Class A or Style D wiring Indicating Circuit Wiring The FA-300 Series Fire Alarm supports Class B (Style Y) and Class A (Style Z) wiring for its indicating circuits. Each circuit is supervised by a 3.9K End-of-Line resistor. Each indicating circuit provides up to 1.7 A, 5 A maximum total if no auxiliaries are used. Figure 15: Indicating circuit – Class B or Style Y wiring Note: When using ICAC Class A Converter Adder Modules, always use Active End-of-Line resistors on all initiating circuits including those that are not converted to Class A. Note: An Active End-of-Line resistor CANNOT be used with an

  • Mircom FA-300 Series, FA-300 Series LCD Version Installation and Operation Manual 53 Command Menu/Dialer Config/Account Info 2.Account#1 Telephone Number [ 101 ]->Default Use this function to set the telephone number of the monitoring station. The maximum # of digits allowed is 19 including “,” and numerals. The “,” will be treated as 1 sec delay. To enter “,” press the INFO button. Press # to move the cursor to the right or press * to move it to the left. An example of a typical telephone # is 9,,12345678. Com

  • Mircom FA-300 Series, FA-300 Series LCD Version Installation and Operation Manual 49 6. Clear Event Log (Command-Menu) Note: Refer to How to Use the Keypad to Program the FA-300 on page 39 for detailed instructions on making menu selections. Select the type of log to clear. Press the “ENTER” key. The system will then confirm before clearing logs. Press the “ENTER” key to confirm or the “CANCEL” key to cancel the operation. Use this function to clear alarm logs, general logs, or both. -Select Log- 1 Alarm Log 2 General Log 3 All Logs Clear all the

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Toshiba CF19H32 Owner's manual toshiba/cf19h32-B52.pdf 17 Jun 2022 31 3.6 Mb
2 RCA 2101-2 Operation & user’s manual rca/2101-2-2K3.pdf 27 Feb 2024 33 1.04 Mb
3 Matsui DVDR100 Operation & user’s manual matsui/dvdr100-LCR.pdf 03 Jan 2023 60
4 Evenflo ExerSaucer Triple Fun User manual manual evenflo/exersaucer-triple-fun-87N.pdf 04 Mar 2023 11
5 MINOURA M20-D Instruction manual minoura/m20-d-52S.pdf 02 Jul 2023 7
6 Sharp R-222R Operation manual sharp/r-222r-M6G.pdf 21 Jan 2024 17 1.79 Mb

Similar Resources:

  • Ei Electronics

    Ei 170

    (3 pages)
    Instruction LeafletEI 170/171 Strobe and Vibration Smoke Alarm System, for the deaf and hard of hearing.IntroductionThis leaflet describes the installation of the EI 170 and EI171 Systems.Important: Read all instructions before installing. This leaf-let must be left with the end user after installation.N.B. If the system is not being used for some time the C …
  • Firex

    G-6

    (8 pages)
    SMOKE ALARM FEATURES•Model PG40 and GC smoke alarms can be interconnected withas many as 11 other specific model smoke alarms (Model G-6,as many as 5).•Model GC features False Alarm Control™ that temporarilysilences nuisance alarms.•Multi-purpose LED indicates that the smoke alarm is receivingAC power, working under normal operation, or in alarm.•L …
  • Cavius

    LUMI-PLUGIN LP120

    (4 pages)
    Important information • The luminaire and heat alarm must be installed in accordance with local wiring regulations if in doubt seek advice from a qualied electrician. • Before installing or completing maintenance work on the luminaire and heat alarm make sure the mains power is switched off. • The luminaire and heat alarm is designed for indoor u …
  • Electro Detectors

    EDA-M100

    (16 pages)
    Radio Fire Alarm System – User Manual Page:1V301_user Feb 2009Electro-Detectors Radio Fire AlarmUser ManualEDA-M100/150/300EDA-M200/350For panels fitted with V3.00 or E3.00 and later firmwareV3.01 …
  • Fire-Lite Alarms

    BG-12LPS

    (2 pages)
    BG-12LPS Manual Pull StationPatented, U.S. Patent No. Des. 428,351; 6,380,846; 6,632,108Document 51479 I56-2268-003DescriptionThe BG-12LPS pull station is a non-coded, dual-action manual pull station with a key-lock reset feature. It provides Fire•Lite control panels with two (2) normally open (N/O) alarm initiating input signals. “Pre-signal” input i …
  • BRK electronic

    Hearing Impaired Strobe Lights SL177

    (5 pages)
    1IMPORTANT! PLEASE READ CAREFULLY AND SAVE.This user’s manual contains important information about your StrobeLight’s operation. If you are installing this Strobe Light for use by others,you must leave this manual—or a copy of it—with the end user.M08-0188-000 J1 05/07 Printed in MexicoBEFORE YOU INSTALL THIS STROBE LIGHTIMPORTANT!Read “Recomme …

Smoke Alarm Instructions:

Comments, Questions and Opinions: