Manualios.com

Bull 1GB Intel Ethernet Switch Module Installation And User Manual

  • 1GB Intel Ethernet Switch Module Network Router
  • ma8gW4EOBzNG6
  • Installation And User Manual
  • PDF / Adobe Acrobat Reader
  • 308

Bull 1GB Intel Ethernet Switch Module Manual Online:

3.3, 2980 votes
Bull 1GB Intel Ethernet Switch Module User Manual
Bull 1GB Intel Ethernet Switch Module User Guide
Bull 1GB Intel Ethernet Switch Module Online Manual

Text of Bull 1GB Intel Ethernet Switch Module User Guide:

  • Bull 1GB Intel Ethernet Switch Module, Run-time Switching Software Default Settings 237 Port Mode Disable config spanningtree port mode System Auto log-out 10 min Configuration update Disable Default gateway 0.0.0.0 IP address 10.90.90.9x, where x depends on the number of the bay into which you have installed the switch module. Subnet mask Class A Network - 255.0.0.0, Class B Network - 255.255.0.0, Class C Network - 255.255.255.0 Configuration System Contact Blank config syscontact System Location Blank config syslocation System Name Blank config sysname Forwarding Database Forwarding Database aging time 30

  • Bull 1GB Intel Ethernet Switch Module, 118 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide CST Path Cost Path Cost to the CST Regional Root. Click the Apply button to send the updated screen to the switch and cause the changes to take effect on the switch. If you want the switch to retain the new values across a power cycle you must perform a save. Click the Force button to force the port to send out 802.1w BPDUs. Click the Refresh button to update the screen with the most recent data. Statistics This panel displays BPDU statistics for the selected port. Port Select the port for which information is to be displayed. STP BPD

  • Bull 1GB Intel Ethernet Switch Module, 108 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide Link Trap Enables or Disables link trap notifications for the specified LAG. Administrative Mode This field Enables or Disables the specified LAG(s). Link Status Indicates whether the Link is Up or Down. STP Mode Sets the STP mode for the specified LAG(s). Port Identifies a physical port. To add the port to the LAG select Include from the Participation column. There can be a maximum of 8 member ports in a LAG. Participation For each port specify whether it is to

  • iv NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide General Safety Follow these rules to ensure general safety: • Observe good housekeeping in the area of the machines during and after maintenance. • When lifting any heavy object: 1. Ensure you can stand safely without slipping. 2. Distribute the weight of the object equally between you

  • Bull 1GB Intel Ethernet Switch Module, 196 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide config protocol vlan add Use this command to attach a <vlan> to the protocol-based VLAN identified by <groupid>. A group may only be associated with one VLAN at a time, however the VLAN association can be changed. Format config protocol vlan add <groupid> <vlan> config protocol vlan remove Use this command to remove the <vlan> from the protocol-based VLAN group identified by the <groupid>. Format config protocol v

  • Bull 1GB Intel Ethernet Switch Module, 276 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide In this example, the VLAN definitions are extended to bridges A and B. This gives only a single blocked port per VLAN and enables the removal of all redundant links by removing bridge A or B from the network. A B C D Blocked Blocked VLAN 1 VLAN 1 VLAN 1 VLAN 1 VLAN 1 VLAN 1 VLAN 2 VLAN 2 VLAN 2 VLAN 2 VLAN 2 VLAN 2 Trunk

  • Bull 1GB Intel Ethernet Switch Module, 274 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide problem, if sufficient time is available. Connectivity will be restored immediately after disabling a data loop. Avoiding network problems To help your network operate more efficiently, you can avoid or minimize network problems, as described in this section. • Know where the root is located. Although the STP can elect a root bridge, a well-designed network has an identifiable root for each VLAN. Careful setup of the STP parameters results in the selection of this best bridge as the root for each VLAN. Redundant links can th

  • Web-Based Network Management 55 method, the third method will not be tried. Note that this parameter will not appear when you first create a new login list. Method 3 Use the pull-down menu to select the method, if any, that should appear third in the selected authentication login list. Note that this parameter will not appear when you first create a new login list. Click the Apply butt

  • Bull 1GB Intel Ethernet Switch Module, NovaScale Blade safety and regulatory information ix ≥18 kg (37 lbs) ≥32 kg (70.5 lbs) ≥55 kg (121.2 lbs) CAUTION: Use safe practices when lifting. CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. CAUTION: Do not place any object weighing more than 82 kg (180 lbs.) on top of rack-mounted device

  • Bull 1GB Intel Ethernet Switch Module, 200 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide Hello Time The hello time in use for this port. Edge Port The configured value indicating if this port is an edge port. Edge Port Status The derived value of the edge port status. True if operating as an edge port; false otherwise. Point To Point MAC Status Derived value indicating if this port is part of a point to point link. CST Regional Root The regional root identifier in use for this port. CST Path Cost The configured path cost for this port. show spanningtree cst port summary Use this command to display the status of one, some or all ports within the CST. The parameter <port/li

  • Bull 1GB Intel Ethernet Switch Module, 172 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide Format config loginsession close <sessionid/all> show loginsession Use this command to display currently active Telnet and serial port connections to the switch. Format show loginsession ID Login Session ID User Name The account name used to login via the serial port or Telnet. Connection From The IP address of the Telnet client machine or EIA-232 for the serial port connection. Idle Time Time this session has been idle. Session Time Total time this session has been connected. System description config prompt Use this command to change the prompt that is displaye

  • 176 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide Transmit Discards Total Transmit Packet Discarded The sum of single collision frames discarded, multiple collision frames discarded, and excessive collision frames discarded. Single Collision Frames The number of successfully transmitted packets which encountered exactly one collis

  • Bull 1GB Intel Ethernet Switch Module, 52 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide User accounts Use this panel to reconfigure an existing user account or to create a new one. This panel is only available for the user with Read/Write privileges, herein referred to as admin. User Use this pull-down menu to select one of the existing accounts, or select Create to add a new one, provided the maximum of five Read-only accounts has not been reached. User Name The name the user will use to login using the serial port, Telnet or Web. It can be up to eight alphanumeric characters an

  • Technical publications ordering form To order additional publications, please fill in a copy of this form and send it via mail to: BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDEX 01 FRANCE Phone: +33 (0) 2 41 73 72 66 FAX: +33 (0) 2 41 73 70 66 E-Mail: [email protected] CEDOC Reference # Designation Qty _ _ _ _ _ _ _ _ _ [ _ _ ] _ _ _ _ _ _ _ _ _ [ _ _ ]

  • Bull 1GB Intel Ethernet Switch Module, 104 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide GMRP Mode Choose the GMRP administrative mode for the switch by selecting Enable or Disable from the pull-down menu. The factory default is Disable. Click the Apply button to update the switch with the values you enter. If you want the switch to retain the new values across a power cycle you must perform a save. Port configuration Use this panel to specify GARP detail for one or all ports. Note: It can take up to 10 seconds for GARP configuration changes to take effect. Port Select the port you want to configure from

  • Bull 1GB Intel Ethernet Switch Module, Web-Based Network Management 47 Inventory information This panel displays inventory information for the switch. System Description The product name of this switch. Machine Type The machine type of this switch. Machine Model The model within the machine type. Serial Number The unique box serial number for this switch. FRU Number The field-replaceable unit number. Part Number The manufacturing part number. Maintenance Level The identification of the hardware change level. Manufacturer The code that identifies the manufacturer, displayed as two two-digit hexadecimal numbers. Base MAC Address The

  • 78 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide Packets Received: Octets Received The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets). This object can be used as a reasonable estimate of Ethernet utilization. If greater pre

  • Bull 1GB Intel Ethernet Switch Module, 120 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide Port access control The Port Access Control menu provides access to configuration, status and summary screens: • Configuration • Port configuration • Port status •Port summary • Statistics •Login • Port access privileges • Port access summary Configuration Use this panel to enable or disable authentication support on the switch. In disabled mode, the IEEE 802.1X configuration is retained and can be changed, but it is not ac

  • Bull 1GB Intel Ethernet Switch Module, Run-time Switching Software Default Settings 235 Switching VLAN Switching Accept frame all config vlan port acceptframe Broadcast Storm disable config vlan bcaststorm Default port VID 1 config vlan port pvid Ingress filter Disable config vlan port ingressfilter Multicast Storm disable config vlan mcaststorm Name VLAN1 = Default config vlan name Port priority 0 config vlan port priority GARP GARP administration disable config garp gmrp adminmode GARP interface disable config garp gmrp interfacemode GARP join timer 20 centiseconds config garp

  • Bull 1GB Intel Ethernet Switch Module, NovaScale Blade safety and regulatory information v Electrical Safety CAUTION: Electrical current from power, telephone, and communication cables can be hazardous. To avoid personal injury or equipment damage, disconnect the server system power cords, telecommunication systems, networks, and modems before you open the server covers, unless instructed otherwise in the installation and configuration procedures. ✏ Important: Observe the following rules when working on electrical equipment. • Use only approved tools and test equipment. Some ha

  • Bull 1GB Intel Ethernet Switch Module, 2 NovaScale Blade 1 GB Intel® Ethernet Switch Module: Installation and User’s Guide Verify that the shipping carton contains a NovaScale Blade 1 GB Intel® Ethernet Switch Module. If the switch module is missing or damaged, contact your local reseller for replacement. Otherwise, return the switch module to its static-protective package. / NOTE The illustrations in this document may differ slightly from your hardware. Related publications This Installation and User’s Guide contains setup and installation instructions for your NovaScale Blade 1GB Intel® Ethernet Switch Module. This publication also provides general information about your switch module, including getting

  • Bull 1GB Intel Ethernet Switch Module, Web-Based Network Management 49 System Description The product name of this switch. System Name The name used to identify this switch. The range for name is from 1 to 31 alphanumeric characters. System Location The physical location of this switch. May be up to 31 alphanumeric characters. The factory default is blank. System Contact The person or organization responsible for this switch. May be up to 31 alphanumeric characters. The factory default is blank. IP Address The IP address of the interface. The factory default value is 0.0.0.0. System Obje

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Weider 2990 I Manual  weider/2990-i-J1V.pdf 31 Aug 2023 32 4 Mb
2 Lasko Wind Tower 2519 Operating manual lasko/wind-tower-2519-K3C.pdf 11 Feb 2024 2
3 Zanussi EM612 Use and care instructions manual zanussi/em612-LQ6.pdf 15 Aug 2022 20 1.82 Mb
4 Woodstock SHOP FOX W1747 Owner's manual woodstock/shop-fox-w1747-93G.pdf 10 Jan 2024 56 8.95 Mb
5 Panasonic AWE560 - COLOR VIDEO CAMERA Operating instructions manual panasonic/awe560-color-video-camera-O3F.pdf 12 Feb 2023 63 0.59 Mb
6 Runco PlasmaWall XP-OPAL50 DHD Specification runco/plasmawall-xp-opal50-dhd-YR7.pdf 31 Dec 2022 1 0.13 Mb

Similar Resources:

  • Zhone

    6211-I3-xxx

    (2 pages)
    ADSL2+ Single Port Modem6211-I3-xxx✓ Auto-connect feature willautomatically detect thefirst usable PVC andautomatically detectPPPoE, PPPoA, and BridgeProtocol(with DHCP Serveravailable)✓ Configurable as either aBridge or Router✓ Filter traffic based onDestination or Source IPAddress and MACAddresses✓ Traffic Class Rules basedon Protocol, Source IP,So …
  • Viessmann

    VITOTRONIC 300 GW2

    (146 pages)
    1VITOTRONIC 300Installation andService InstructionsVitotronic 300, Model GW2Outdoor-reset logic digital boiler andheating c ircuit control unitCertified as a component partof Viessmann boilers onlyRead and save these instructionsfor future reference.IMPORTANTfor use by heating contractor5285 941 - 01 06/2015Please file in Service Binder …
  • ZyXEL Communications

    P-650R

    (2 pages)
    BenefitsNetwork Reporting Analyzer vantage report 2.2łEase of use and deploymentłFriendly web-based user interface łComprehensive graphical reportsłOne-click on-demand report availablełReal time and historical reports availablełReport aggregation from one to multiple ZyWALL devicesłConcurrent sessions supportAvaila …
  • Black Box

    LW6005A

    (134 pages)
    1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746© Copyright 2004. Black Box Corporation. All rights reserved. …
  • Netac

    T610

    (39 pages)
    Netac AirTrack T610 Wireless Broadband Router User's Manual Netac Technology Co., Ltd. http://www.netac.com …
  • RuggedCom

    RUGGEDSWITCH RS900G

    (17 pages)
    RuggedCom Inc. I 30 Whitmore Road, Woodbridge, Ontario, Canada L4L 7Z4 Tel: (905) 856-5288 I Fax: (905) 856-1995 I Toll Free: (888) 264-0006 RuggedSwitchRuggedSwitchRuggedSwitchRuggedSwitch RS900G RS900G RS900G RS900G 10-Port Managed Ethernet Switch wit …

Comments, Questions and Opinions: