Manualios.com

Tadiran Telecom TGI-07H Instruction Manual

Tadiran Telecom TGI-07H Manual Online:

3.25, 2340 votes
Tadiran Telecom TGI-07H User Manual
Tadiran Telecom TGI-07H User Guide
Tadiran Telecom TGI-07H Online Manual

Text of Tadiran Telecom TGI-07H User Guide:

  • Tadiran Telecom TGI-07H, Compact Size Microprocessor Controlled Operation Simple One-touch Wireless Remote Control 12-Hour ON or OFF Timer 1-Hour OFF Timer Night Setback Automatic and 3-step Fan Speed This model is smaller than its predecessors and yet offers the same capabilities. The interior compartment of the remote control unit contains several features to facilitate automatic operation, clearly displayed for easy use. The remote control unit has several features to facilitate automatic operation. This timer can be set to automatically turn the unit on or off at any time within a 12-hour period. This timer can be set to automatically turn off the unit afte

  • Contents 1 Page Alert symbol Caution statements Composition of the air conditioner Operation guide Care and cleaning Tips for energy saving Troubleshooting Schematic diagram Pardon not to inform you if the contents of the manual changes. 1 2 3 8 16 18 18 19 WARNING CAUTION Alert Symbols The symbol refers to a hazard or an unsafe practice which can result in severe personal injury or death. The sy

  • Tadiran Telecom TGI-07H, Caution Statements WARNING WARNING WARNING CAUTION 2 1.Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button. 2.Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed. 3.Do not let the children play with the air conditioner. 4.Do not cool or heat the room too much if babies or invailds are present. 3.Never use store gasoline or other flammable vapor or liquid near the air conditioner - it is very dangerous. 4.The air conditioner has no ventilator for intaking fresh air from outdoors. You must open

  • Tadiran Telecom TGI-07H, Air intake grille INDOOR UNIT Air outlet Remote control unit Drain hose Refrigerant tubes OUTDOOR UNIT Air outlet Composition of the Air Conditioner 3 1.Diagram of Structure This air conditioner consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote control unit. NOTE Air Intake Air Outlet Remote Control Unit Refrigerant Tubes Outdoor(Condensing)Unit Drain Hose Air from the room is drawn into this section and passes through air filters which remove dust. Conditioned air is blown out of the air

  • Tadiran Telecom TGI-07H, INDOOR UNIT OPERATING lamp TIMER lamp POWER lamp POWER TIMER OPERATING HIGH POWER lamp REMOTE CONTROL receiver ON/OFF button 4 2.Introduction of the Indoor ControI Unit IMPORTANT: Avoid using radio equipment such as mobile phone near (within 1m) the indoor unit. Some radio equipment may cause maIfunction of the unit. If the troubIe happens, dis- connect power and restart the air conditioner after a few minutes. REMOTE CONTROL receiver ON/OFF button POWER lamp OPERATING lamp TIMER lamp HIPOWER lamp This section picks up infrared signals from the remote control u

  • Tadiran Telecom TGI-07H, 1 A TEMP SET C 1HOUR A HOUR ON OFF Displayed when one-hour OFF timer is enable Displayed when setting timer Symbols 3.Introduction of Display (1) Operation mode AUTO COOL HEAT MILD DRY FAN (2) Fan speed Automatic operation HIGH MEDIUM LOW (4) Timer 12-hour ON Timer 12-hour OFF Timer 1-hour OFF Timer (5) NIGHT SETBACK (6) Confirmation of transmission (7) Flap angle indication (8) Sweep indication (9) Indoor unit sensor ON OFF A A (3) Set temperature 16-30 When set to 28 Current temperature indication C 5 Displayed when se

  • Tadiran Telecom TGI-07H, 1HR TEMP FAN SPEED H.P. ON/OFF FLAP MODE ON OFF SLEEP SET CANCEL ACL A/C SENSOR SENSOR A/C SENSOR button Transmitter Battery compartment (pull off the cover to expose the batteries.) (Cover closed) TEMP.setting button ON/OFF button ACL button 4.Introduction of the Remote control Unit NOTE The illustration above pictures the remote control unit after the cover has been lowered and removed. When you press the buttons on the remote control unit,the mark appears in the display to transmit the setting changes to the receiver in the air conditioner. A temperature sensor inside the remote control unit senses the room temperature. Information on the operating conditions is displayed while the r

  • :The air conditioner starts at the set time. The air conditioner stops at the set time. or :The air conditioner makes the room warm. :The air conditioner reduces the humidity in the room. direction to one of the six possible positions manually, or to select the The airflow direction can be set manually.(six positions) :The flap moves up and down automatically.

  • Tadiran Telecom TGI-07H, Operation Guide B ACL button 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. or when the remote control unit cannot be used to change the air conditioner s settings. Use two fresh leak-proof type-AAA alkaline batteries. In replacing batteri s, follow the instructions as mentioned in

  • Tadiran Telecom TGI-07H, Operation with the Remote Control Unit(continued) STEP 4 STEP 1 NOTE Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is in the ON position. If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the settings as desired. STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 Press the MODE selector button and select the desired mode. For heating operation For dehumidifying operation For cooling

  • Tadiran Telecom TGI-07H, Adjusting the Fan Speed A A A. Automatic Simply set the FAN SPEED selector to the position. A microcomputer in the air conditioner automatically controls the fan speed when the mode is selected. When the air conditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is detected by the microcomputer which then automatically switches the fan speed to the most suitable level. RT T+3 T+3 RT T+1 RT T+1 Cooling mode: When difference between room temperatureand set temperature is FAN SPEED High Medium Low RT T+5 T+5 RT T+3 Rt T+3 Mild drying mode: When difference between room temperature and set temperature is FAN SPEED High

  • Tadiran Telecom TGI-07H, Adjusting the Airflow Direction The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. 2. Vertical 1. Horizontal ! CAUTION When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way to the right or left, condensation may begin to form around the air vent and drip down. The vertical airflow can be adjusted by moving the flap with the remote control unit Do not move the flap with your hands.Confirm that the remote

  • Night Setback / Simultaneous Use Energy Saving Night Setback Mode Night Setback Mode is used for saving energy. Press the SLEEP button in operation. The mark appears in the display. To release the night setback function, press the SLEEPbutton again. NOTE A.In Cooling and DRY Mode: This function loses in automation or airflow mode. When the night setback mode is selected, the air cond

  • Tadiran Telecom TGI-07H, Using the 12-Hour ON and OFF Timer STEP 2 STEP 3 STEP 1 1.TIMER ON mode (Example) After the length of time set for TIMER ON elapses, the unit begins operating. Setting Procedures: The display depicted at left indicates that the air conditioner will begin operating in three hours. Press the MODE button and set the desired operation mode and press the ON/OFF operation button. STEP 2 Press the timer ON button to set the time at which you want operation to begin. The time can be set for one to twelve h

  • Tadiran Telecom TGI-07H, Using the 1-Hour OFF Timer 14 This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. Setting procedure: Cancellation procedure: If, while the 1-Hour T imer function is operating, the 1 HR.TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops. If the 1 HR.TIMER button is pressed while the TIMER OFF function operates,the OFF Timer is cancelled and the unit will stop

  • Tadiran Telecom TGI-07H, 15 Special Remarks Heating ( ) Operation Heating performance Defrosting POWER lamp Because this air conditioner heats a room by drawing on the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner, use another heating appliance in conjunction with it. When the outdoor temperature is low , frost or ice may from in the heat exchanger coil, reducing heating performance. When this happens, a microcomputer defrosting system will operate. At the same time the fan on the indoor unit stops ( or runs at very low speed in some cases). Heating oper

  • Tadiran Telecom TGI-07H, Operation without the Remote Control Unit INDOOR UNIT Care and Cleaning NOTE If you have lost the remote control unit or it has trouble, follow the steps below. 1.When the air conditioner is not running If you want to turn on the air conditioner, pressing the ON/OFF button once. 2.When the air conditioner is running If you want to turn off the air conditioner, pressing the ON/OFF button once. Pressing buttons cannot last too long time, or the air conditioner may operate abnormally. ! WARNING 1.For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. 2.Do not pour water on the indoor unit to clean

  • Tadiran Telecom TGI-07H, Care and Cleaning (continued) Anti-Mold Filter How to remove the anti-mold filter The anti-mode filter behind the air intake grille should be checked and cleaned at least once every three weeks. 1.Grasp both ends of the air intake grille and pull it out and up. 2.Push the anti-mold filter up slightly, and then pull it down. Air intake grille Anti-mold filter Air intake grille Anti-mold filter Anti-Mold Filter Cleaning How to replace the anti-mold filter Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, wash the filter in lukewarm, soapy water, rinse it in clean water, and dry it

  • Tadiran Telecom TGI-07H, Tips for Energy Saving Do not Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged. Let sunlight directly into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer time to cool the room. Do Always try to keep the air filter clean. (Refer to Care and Cleaning A clogged filter will impair the performance of the unit. To prevent conditioned air from escaping, keep windows, do

  • Schematic Diagram 2. Refrigerant Flow Diagram TGI -12H AC,230V/50Hz 1220W/1260W 3300W/3550W 8m/80 15m 450m /h R22/1.30kg 3 1. Main specifications of the product Type Power source Power consumption of input (cooling/heating) P ower (cooling/heating) Air flow (high) Refrigeration dose/consumption Maximum remote control range/ angle range Maximum length of the connect tube 19 TGI-

  • Tadiran Telecom TGI-07H, 1 2 3 4 5 S R C TO INDOOR TERMINAL COMP FAN MOTOR RV YLW/GRN BLK RED RED BLK WHT BLU BLU WHT GRY CAPA YLW/GRN YLW/GRN BRN CAPA PNK 4 WAY VALUE ASSY 4. Electric Wiring Diagram Outdoor FAN MOTOR 1 2 3 4 5 1 2 3 4 5 123 12 12 12 12 1~8 1~8 135 135 123 1 2 1 2 1 2 1 2 ROOM COIL SU COM CM FM VA FLAP FM PULSE IN SW PRY SEC 0 1 2 3 4 5 TRANSFORMER SENSOR SENSOR PLUG EVAPORATOR TERMINAL TO OUTDOOR UNIT FLAP MOTOR CONTROL BOARD SWITCH ASSY YLW/GRN YLW/GRN BRN BRN BRN BRN BLU BLU RED BLK BLK WHT WHT BRN BLK YLW RED ORG YLW PNK BLU WHT BLK WHT BLK RED RED CAPACITOR Intdoor 20

  • Tadiran Telecom TGI-07H, PACKING LIST NO. NAME AMOUNT PACKING LOCATION 1. 3. 4. 5. 6. 7. 8. 9. 10. 11. 13. OUTDOOR UNIT DRAINAGE ELBOW * AIR FRESH FILTER INDOOR UNIT INSTRUCTION MANUAL INSTALLATION MANUAL REMOTE CONTROL UNIT BATTERY NAIL SPECIAL BOLT SPECIAL COVER 1 1 1 1 1 1 1 2 6 6 1 OUTDOOR OUTDOOR OUTDOOR INDOOR INDOOR INDOOR INDOOR INDOOR INDOOR INDOOR INDOOR THE SYMBOL "*" STANDS FOR THE PART TO BE PICKED AND MADE PURCHASE.

More Instructions:

DOWNLOAD

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Gateway AD-520 Operation & user’s manual gateway/ad-520-938.pdf 24 Nov 2023 92 4.34 Mb
2 Insignia NS50D40SNA14 Manual  insignia/ns50d40sna14-KB8.pdf 02 Feb 2023 8
3 Kenwood DDX7015 - Excelon - DVD Player Installation manual kenwood/ddx7015-excelon-dvd-player-365.pdf 29 Nov 2023 5
4 Haier JW-W40D Operation & user’s manual haier/jw-w40d-3MC.pdf 30 Dec 2023 20 6.05 Mb
5 Ford Tire Warranty manual ford/tire-K25.pdf 24 Aug 2022 75 1.08 Mb
6 Sony CDX-L550V Operating instructions manual sony/cdx-l550v-5B6.pdf 02 Dec 2023 122 2.3 Mb

Similar Resources:

  • Gulfstream

    A-CLASS Series

    (16 pages)
    DESIGN AND INSTALLATION MANUALFOR THE ROOF TERMINAL FLUE KITFOR PITCHED AND FLAT ROOFSROOF TERMINAL FLUE KIT G.C. NO .................THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS -In your own interest and that of safety, it is law that all gas appliances are installed by competent persons and in accordance with the above regulations.TMbenchmarkThe code …
  • Electrolux

    EXP09

    (132 pages)
    ...........................................................................................................BGɄɅɂɆȺɌɂɄCS./,0$7,=$ý1Ë=$ěË=(1ËEN$,5&21',7,21(5HU/e*.21',&,21È/ÏPL KLIMATYZATORROA3ARAT'(&LIMATIZAR(SKKLIMATIZÈ&IAɊɔɄɈȼɈȾɋɌȼɈɇȺɉɈɌɊȿȻɂɌȿɅə1È9O'K3O8äITË86(RMA1 …
  • Daikin

    Altherma 3 H MT ECH2O

    (24 pages)
    Operation manualDaikin Altherma 3 H MT ECH₂OEnglishOperation manualDaikin Altherma 3 H MT ECH₂OETSH12P30EFETSH12P50EFETSHB12P30EFETSHB12P50EFETSX12P30EFETSX12P50EFETSXB12P30EFETSXB12P50EF …
  • Trane

    IntelliPak Signature Series

    (80 pages)
    ProgrammingGuidePKG-SVP01B-ENIntelliPak®Commercial Self-ContainedSignature Series, 20-80 TonModular Series, 20-35 TonModels“AO” and later Design SequenceSCWG -020, -025, -030, -035SIWG -020, -025, -030, -035SCRG -020, -025, -032SIRG -020, -025, -032SCWF -020, -022, -025, -029, -032, -035, -038, -042, -046, -052, -058, -065, -072, -080SIWF -020, -022, -0 …
  • Hitachi

    RAS-S24CPX

    (22 pages)
    Instruction manual Page 1~22To obtain the best performance and ensure years oftrouble free use, please read this instruction manualcompletely.تﺎﻤﻴﻠﻌﺘﻟا ﺐﻴﺘﻛ٢٢-١ ص ﻮـﻃ ةﺪﳌ زﺎﻬﳉا لﺎﻤﻌﺘﺳا ﻦﻜﳝ ﻲﻜﻟعﻼﻃﻹا ﺐﺠﻳ ﺐﻄﻋ نوﺪﺑ ﺔﻠﻳ.اﺪﻴﺟ ﺐﻴﺘﻜﻟا …
  • Panasonic

    S-36PU2E5B

    (20 pages)
    Operating Instructions Air ConditionerENGLISH 2 ~ 9Before operating the unit, read these operating instructions thoroughly and keep them for future reference.FRANÇAIS 10 ~ 17Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.ESPAÑOL 18 ~ 25Antes de operar la unidad, lea atenta …

Comments, Questions and Opinions: